ClimateMaster NC Series Installation Instructions Manual
|
ClimateMaster NC Series, INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR SERIES NB, NC, ND, NE, NF, & NG 97B0042N05 Rev.: 04 April, 2014 Installation Instructions For Energy Recovery Wheel (Fixed) For Stand Alone Over/Under Mechanical Room Application Energy recovery COMPONENT certifi ed to the ARI Air-to- Air Energy Recovery Ventilation Equipment Certifi cation Program in accordance with ARI Standard 1060-2000. Actual performance in packaged equipment may vary. ETL Certifi ed per UL 1995 and CSA 22.2 Inspection Upon receipt of shipment
ClimateMaster NC Series, THE SMART SOLUTION FOR ENERGY EFFICIENCY N (ERV) Series Rev.: 04 April, 2014 3 climatemaster.com Installation 1. Attach duct work to duct fl anges on ERV. 2. Remove ERV control access panel to connect fi eld wiring. 3. Route class II low voltage wire (3 conductor) from thermostat or energy management through small bushing in end panel of ERV. See wiring diagram. a. Thermostat (dependent) - connect in parallel at rooftop unit with “G”, “C” and “W”. Then connect matching color at terminal 1, 2, and 3 respectively on ERV circuit
ClimateMaster NC Series, CLIMATEMASTER WATER-SOURCE HEAT PUMPS N (ERV) Series Rev.: 04 April, 2014 4 ClimateMaster Water-Source Heat Pumps times that of the sensible heat load and in the winter it is a signifi cant part of a humidifi cation heat load. During both the summer and winter, the ERW transfers moisture entirely in the vapor phase. This eliminates wet surfaces that retain dust and promote fungal growth as well as the need for a condensate pan and drain to carry water. Because it is constantly rotating when in the air stream, the ERV is always being cleaned by air, fi rst in one direction then the other. Because it is a
ClimateMaster NC Series, THE SMART SOLUTION FOR ENERGY EFFICIENCY N (ERV) Series Rev.: 04 April, 2014 5 climatemaster.com load conditions. 1. Disconnect main power to unit before making adjustment to economizer and/or ERV unit. 2. Replace ERV control access cover. 3. Set thermostat to normal operating position. 4. Restore power to unit. Maintenance 1. All motors use pre-lubricated sealed bearings; no further lubrication is necessary. 2. Make visual inspection of motors, belts and wheel rotating bearings during routine maintenance. 3. Eight pie-shaped segments, are seated on stop
ClimateMaster NC Series, CLIMATEMASTER WATER-SOURCE HEAT PUMPS N (ERV) Series Rev.: 04 April, 2014 6 ClimateMaster Water-Source Heat Pumps EXHAUST AIR FRESH AIR RETURN AIR TREATED AIR Features and Notes: 1. Stand alone design allows higher levels of outdoor air to be introduced into the conditioned space. 2. Static test ports provided to verify intake and exhaust CFM. 3. Balancing damper(s) is fi eld provided when connected to ductwork. System may not operate properly without balancing damper. 4. See blower performance charts for airfl ow at
THE SMART SOLUTION FOR ENERGY EFFICIENCY N (ERV) Series Rev.: 04 April, 2014 7 climatemaster.com Notes: 1. Remove jumper to install field optional low ambient switch. 2. Se lec tive volt age ter mi nals for proper unit volt age. 3. Optional low ambient switch. 4. Optional motorized intake damper. 5. Op tional Stop, Start and Jog Con trol. 6. For energy man age ment systems connect
ClimateMaster NC Series, CLIMATEMASTER WATER-SOURCE HEAT PUMPS N (ERV) Series Rev.: 04 April, 2014 8 ClimateMaster Water-Source Heat Pumps Notes: 1. Remove jumper to install field optional low ambient switch. 2. Step-down transformer assembly for 460/575 volt only units. 3. Move wire for dif fer ent volt age in put. 4. Optional low ambient switch. 5. Optional motorized intake damper. 6. For energy man age ment systems connect +24v to green and common 24v to black. NB-GERV 208/230-3-60 460-3-60 575-3-60 ERV UNIT SCHEMATIC DIAGRAM (FIELD INSTALLED) Wire
ClimateMaster NC Series, THE SMART SOLUTION FOR ENERGY EFFICIENCY N (ERV) Series Rev.: 04 April, 2014 9 climatemaster.com NB-C ERV UNIT WIRING DIAGRAM Notes: 1. Remove jumper to install field optional low ambient switch. 2. Selective voltage terminals for proper unit voltage. 3. Optional low ambient switch. 4. Optional motorized intake damper. 5. Optional Stop, Start and Jog Control. 6. For energy management systems connect +24v to “G” and common 24v to “C”. 208- 230V (1 PH) Desiccant Wheel for Roof top Unit
CLIMATEMASTER WATER-SOURCE HEAT PUMPS N (ERV) Series Rev.: 04 April, 2014 10 ClimateMaster Water-Source Heat Pumps NB-G ERV UNIT WIRING DIAGRAM 208- 230/460/575V (3 PH) Desiccant Wheel for Roof top Unit Notes: 1. Remove jumper to install field optional low ambient switch. 2. Step-down transformer assembly for 460/575 volt units. 3. Selective voltage terminals for proper unit volt age
ClimateMaster NC Series, THE SMART SOLUTION FOR ENERGY EFFICIENCY N (ERV) Series Rev.: 04 April, 2014 11 climatemaster.com Mist Eliminator Filter in Intake Hood (1.5HP) External Static Pressure (in water) 0 0.25 0.5 0.75 1 1.25 1.5 CFM 300 N/A N/A 980 1065 1320 1400 1520 500 N/A 905 1050 1215 1360 1495 1595 700 865 1035 1210 1330 1440 1535 1620 900 1030 1205 1325 1435 1530 1615 1725 1100 1200 1320 1430 1525 1605 1720 1800 Barometric Hood, 2" Pleated Filters (1.5HP) External Static Pressure (in water) 0 0.25 0.5 0.75 1 1.25 1.5 CFM 300 N/A 815 1030 1185 1305 1450 1535 500 N/A 950 1075 1220 1375 1490 1610 700 810 1070 1195 1295 1445 1510 1645 900 995 1125 1290 1405 1500 1600 1690 1100 1
ClimateMaster NC Series, CLIMATEMASTER WATER-SOURCE HEAT PUMPS N (ERV) Series Rev.: 04 April, 2014 12 ClimateMaster Water-Source Heat Pumps Mist Eliminator Filter in Intake Hood (3HP) External Static Pressure (in water) 0 0.25 0.5 0.75 1 1.25 1.5 CFM 1200 N/A 900 1045 1135 1255 1395 1410 1600 880 1035 1130 1245 1385 1405 1450 2000 1045 1145 1235 1325 1400 1440 1555 2400 1 135 1300 1375 1435 1505 1550 1590 2800 1295 1365 1435 1515 1580 1625 1695 Barometric Hood, 2" Pleated Filters (3HP) External Static Pressure (in water) 0 0.25 0.5 0.75 1 1.25 1.5 CFM 1200 N/A 955 1075 1185 1285 1355 1495 1600 945 1055 1175 1265 1335 1445 1635 2000 1045 1170 1330 1395 1440 1570 1695 2400 1210 1325 1435
ClimateMaster NC Series, THE SMART SOLUTION FOR ENERGY EFFICIENCY N (ERV) Series Rev.: 04 April, 2014 13 climatemaster.com Mist Eliminator Filter in Intake Hood (5HP) External Static Pressure (in water) 0 0.25 0.5 0.75 1 1.25 1.5 CFM 3000 840 990 1065 1135 1215 1265 1335 3400 875 1060 1130 1205 1255 1320 1385 3800 1015 1120 1200 1245 1315 1365 1450 4200 1080 1195 1240 1350 1395 1445 1510 4600 1 120 1200 1315 1380 1460 1515 1560 Barometric Hood, 2" Pleated Filters (5HP) External Static Pressure (in water) 0 0.25 0.5 0.75 1 1.25 1.5 CFM 3000 850 995 1065 1135 1220 1270 1335 3400 925 1060 1130 1225 1265 1330 1375 3800 1020 1120 1220 1285 1325 1370 1430 4200 1 100 1215
ClimateMaster NC Series, CLIMATEMASTER WATER-SOURCE HEAT PUMPS N (ERV) Series Rev.: 04 April, 2014 14 ClimateMaster Water-Source Heat Pumps CLIMATE MASTER, INC. LIMITED EXPRESS WARRANTY/ LIMITATION OF REMEDIES AND LIABILITY It is expressly understood that unless a statement is specifi cally identifi ed as a warranty, statements made by Climate Master, Inc., a Delaware corporation, (“CM”) or its representatives, relating to CM’s products, whether oral, written or contained in any sales literature, catalog or any other agreement, are not express warranties and do not form a part of the basis of the bargain, but are merely CM’s opinion or commendation of C
ClimateMaster NC Series, CLIMATEMASTER WATER-SOURCE HEAT PUMPS N (ERV) Series Rev.: 04 April, 2014 16 ClimateMaster Water-Source Heat Pumps Revision History *97B0042N05* 97B0042N05 ClimateMaster works continually to improve its products. As a result, the design and specifi cations of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000 for specifi c information on the current design and specifi cations. Statements and other information contained herein ar
Haier HPND14XCT Air Conditioner Installation and user manual
HPND14XCT |
Fisher FSK-124HF Air Conditioner Technical service manual
FSK-124HF |
Haier HSU-12HT03 Air Conditioner Operation manual
HSU-12HT03 |
Carrier 51CM Air Conditioner Start-up and service instructions
51CM |
Royal Sovereign RDH-M050 Air Conditioner Specifications
RDH-M050 |
Airrex HSC-14 Air Conditioner Operation & user’s manual
HSC-14 |
Sanyo 18KLS72 Air Conditioner Instruction manual
18KLS72 |
Bard WA302 Air Conditioner Installation instructions manual
WA302 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Apple | iMac G5 | Replacement instructions manual | apple/imac-g5-884.pdf | 12 Aug 2022 | 13 | 2.17 Mb |
2 | jbc | DI | Quick start manual | jbc/di-A13.pdf | 14 Nov 2023 | 4 | |
3 | Xaircraft | X650 PRO | Instruction manual | xaircraft/x650-pro-FS3.pdf | 25 Feb 2024 | 13 | |
4 | Olympus | Stylus 1040 | Basic manual | olympus/stylus-1040-JH2.pdf | 11 Jun 2023 | 124 | |
5 | APW Wyott | WS-2 | Installation and operating instructions manual | apw-wyott/ws-2-OHV.pdf | 15 Sep 2022 | 12 | 0.27 Mb |
6 | protech | IBIS120 | Instruction manual | protech/ibis120-1CU.pdf | 04 Aug 2022 | 20 |
Technibel
Pub. OI-854641897250002005Save These Instructions!Conserver ce mode d’emploiBewahren Sie bitte dieseBedienungsanleitung auf.Conservate queste istruzioniGuarde estas instruçõesΦυλάξτε τις οδηγίες αυτέςGuarde estas instruccionesSystem Controller for Split System AirConditionerContrôleur de système pour climatiseur d’air àdeux bl …
K70DO43ZAA(58 pages) |
Lennox
Split Air ConditionerThank you for selecting LENNOX air conditioners.Please read this manual carefully before operation and keep it for further reference.OWNER'S MANUALLENNOX AIR CONDITIONERS MODEL:LM012CI-100P432-1LM012CO-100P432-1
…
LM012CI-100P432-1(40 pages) |
Carrier
40GJ*CCassette Ductless Split System Sizes 12 to 24 Owner' s Manual NOTE TO EQUIPMENT OWNER: Please read this Owner’s Information Manual carefully before installing and using this appliance and keep this manual for future reference. For your convenience, please record the model and serial numbers of your new equ …
40GJ(24 pages) |
LG
Cassette-Type Air ConditionerSVC MANUAL(Exploded View)MODEL : ATNH243PLAE[LCN246HV]CAUTIONBefore Servicing the unit, read the safety precautions in General SVC manual.Only for authorized service personnel.Internal Use Onlyhttp://biz.lgservice.com
…
ATNH243PLAE(7 pages) |
Carrier
OWNER’S MANUALAIR CONDITIONER (SPLIT TYPE)For general public useIndoor unit42GCVBE010, 013, 018-70342GCVBE010, 013, 018-303P42TEVGB010, 013, 018-703Outdoor unit38GCVBE010, 013, 018-70338GCVBE010, 013, 018-303P38TEVGB010, 013, 018-7031110255146R32ENGLISHESPAÑOLENGLISHภาษาไทย1110255146_EN.indd 11110255146_EN.indd 1 12/13/2560 BE 14:3212/ …
42GCVBE010-703(8 pages) |
Daikin
Service Manual SM-Inverter_(i) Air Conditioners Service Manual Split Inverter SM-12-012
…
SM-12-012(54 pages) |
Arctic Cat Offroad Vehicle 400 TRV400 TRV Service manual - UZ7J2F 400 TRV, 274 |
NEC Telephone 2000 PBXNEC Telephone Operation & user’s manual (File: nec-2000-pbx-operation-user-s-manual-4, Thursday 25-01-2024) 2000 PBX, 4 |
Clarity Telephone RC100RC100 Operating instructions manual - JP7D55 RC100, 42 |
Samsung Monitor DM65DMonitor PDF Quick setup manual DM65D, 2 |
Craftsman Lawn Mower 917.388124Craftsman Lawn Mower Owner's manual (File: craftsman-917-388124-lawn-mower-44, Sun 10.2023) 917.388124, 44 |
Biostar Other P4M800-M7A - BIOS SETUP#25U995: P4M800-M7A - BIOS SETUP Other Manual P4M800-M7A - BIOS SETUP, 36 |
Philips Cassette Player Video Cassette RecorderCassette Player #82O5N2 Video Cassette Recorder, 15 |
Koch Guitar Electronics Musical Instrument Amplifier SupernovaSupernova Operating instructions manual - P96EX6 Supernova, 12 |
Axiohm Printer A794-D100A794-D100 Owner's manual - BQ174J A794-D100, 140 |
fischertechnik Toy ROBO TXROBO TX (Toy ePDF User Guide, #767EZV) ROBO TX, 16 |
Zte Modem MF193AZte MF193A Modem Quick start manual MF193A, 14 |
Antec Enclosure NSK 6580Antec Product Guide: NSK 6580 PDF Operation & user’s manual - 17QP22 NSK 6580, 9 |