Manualios.com

Dovre 525CB Installation Instructions And Operating Manual

  • 525CB Cooktop
  • maSarNY.40dJU
  • Installation Instructions And Operating Manual
  • PDF / Adobe Acrobat Reader
  • 21

Dovre 525CB Manual Online:

3.9, 820 votes
Dovre 525CB User Manual
Dovre 525CB User Guide
Dovre 525CB Online Manual

Text of Dovre 525CB User Guide:

  • Dovre 525CB, INSTALLATIEVOORSCHRIFTEN EN GEBRUIKSAANWIJZING HOUTKACHEL INSTALLATION INSTRUCTIONS AND OPERATING MANUAL WOOD STOVE INSTALLATION ET MODE D’EMPLOI POELE A BOIS EINBAUANLEITUNG UND GEBRAUCHSANWEISUNG HOLZ-FEUERSTÄTTE INSTRUCCIONES DE INSTALACIÓN Y USO ESTUFA DE LEÑA 525CB 03.27696.100 - 02-2013

  • Dovre 525CB, Table of contents Introduction 3 Declaration of conformity 3 Safety 4 Installation requirements 4 General 4 Chimney (flue) 4 Ventilation of the area 5 Floors and walls 5 Product description 6 Installation 6 General preparation 6 Preparing the outside air connection 8 Installing and connecting 8 Use 9 First use 9 Fuel 9 Lighting 9 Burning wood 10 Controlling combustion air 11 Extinguishing the fire 11 Removing ashes 11 Fog and mist 12 Solving problems 12 Maintenance 12 Chimney 12 Cleaning and other regular maintenance activities 12 Spare parts 525CB 13 Appendix 1: Tech

  • Dovre 525CB, Introduction Dear user, In buying this DOVRE heating appliance, you have chosen a high quality product. This product is part of a new generation of energy-efficient and environmentally-friendly heating appliances. These appliances make optimum use of convection heat as well as thermal radiation (radiant heat). Your DOVRE appliance has been manufactured with state-of-the-art production equipment. In the unlikely event of a malfunction, you can always rely on DOVRE for support and service. The appliance should not be modified; please always use original parts. The appliance is intended for u

  • Dovre 525CB, Safety Please note: All safety regulations must be complied with strictly. Please read carefully the instructions supplied with the appliance for installation, use and maintenance, before using the appliance. The appliance must be installed in accordance with the laws and requirements of your country. All local regulations and the regulations relating to national and European standards must be observed when installing the appliance. The appliance should preferably be installed by an authorized installer. Installers will be a

  • Dovre 525CB, A draught/vacuum of 15-20Pa during normal operation is ideal. Starting from the flue spigot, the flue must run as vertically as possible. Changes in direction and horizontal pieces disrupt the outward flow of combustion gases and may cause soot deposits. To prevent combustion gases from cooling down too much, which reduces the draught, ensure that the interior diameter is not too big. The flue or chimney should ideally have the same diameter as the connection collar. For the nominal diameter: see the appendix "Technical data". If the smoke channel is well insulated, the diameter may be slightly bigger (up to 2x the section of the conne

  • Dovre 525CB, between the connecting tube and combustible material. The rule of thumb for a single-walled tube is a distance of 3x the diameter. If a lining shell is fitted around the tube, a distance of 1x the diameter is permissible. Carpets and rugs must be at least 80cm away from the fire. Use a fireproof floor plate to protect a flammable floor from any ash which may fall in front of the stove. The protective plate must comply with national standards. For the dimensions of the fireproof protective plate: see the appendix "

  • 09-20008-002 2. Remove the fire-resistant inner plates; see the following figure. a. Remove the fire basket(6). b. Raise the baffle plate(5) at the front, pull the baffle plate 2 cm forwards and allow the baffle plate to drop down at the back c. Remove the inner plates on the left and right sides(4). d. Remove the inner plates on the back(3). Cast iron inner plates

  • 09-20008-006 3 4 5 6 7 9 2 1 2 8 10 Connect to top Upon provision, the connection is fitted at the back, therefore you need not install a cover on the back. Because of the distance to the (combustible) wall, the protection plate may not be removed in the back shield. 1. Apply supplied fibre glass sealing tape (3) measuring 10x3mm to the contact sur

  • 2. Connect the appliance airtight to the flue (chimney). 3. In the case of connection to outside air: connect the outside air supply to the connector fitted to the appliance. 4. Re-position all removed parts in the correct places in the stove. Never light a fire in the appliance without the fireproof inner plates. The appliance is now ready for use. Use First use When you use the stove for t

  • Dovre 525CB, 4. Close the door of the appliance and open the primary air inlet and the secondary air inlet of the appliance; see the following figure. 5. Allow the fire develop into a good blaze until there is glowing bed of charcoal. You can then add fuel and adjust the appliance, see the chapter "Stoking with wood". 09-20008-008 1 2 Open Closed Burning wood After you have followed the instructions for lighting : 1. Slowly open the stove door. 2. Spread the charcoal evenly across the bottom of the stove base. 3. Stack a few logs on the charcoal. Open stacking If the logs are stacked op

  • Dovre 525CB, Controlling combustion air The appliance has various features for air control; see following figure. 09-20008-010 1 2 3 The primary air slide controls the air flow under the grille (1). The secondary air slide controls the air flow in front of the glass (air-wash) (2). The back wall has permanent vents (3) below the baffle plate that allow for post-combustion. Advice Never burn wood with an open door. Regularly burn wood with intense roaring fires. If you frequently have low intensity fires, tar and creosote may be deposited in the chimney . Tar and creosote are highly combustible substances. Thicker layers of these substances may catch fire if the temperature in the chimney increase

  • 09-20008-009 13 2 1. Open the stove door. 2. Use the scraper (2) to open the ash removal port (1) by opening the bottom of the fire compartment. 3. Scrape the excess ash through the de-ashing cover into the ash pan (3) below it. 4. Close the ash removal port. 5. Using the glove supplied, remove the ash pan and empty it. 6. Replace the ash pan and close the stove door. F

  • Dovre 525CB, longer be able to dissipate the heat to the surroundings and this may cause the plate to warp or crack. Never use the stove without the fire-resistant inner plates. Cleaning glass Dirt clings less easily to well-cleaned glass. Proceed as follows: 1. Remove dust and loose soot with a dry cloth. 2. Clean the glass with stove glass cleaner: a. Apply stove glass cleaner to a kitchen sponge, rub down the entire glass surface and give the cleaning agent time to react. b. Remove the dirt with a moist cloth or kitchen tissue. 3. Clean the glass again with a normal glass cleaning prod

  • Dovre 525CB, Appendix 1: Technical data Model 525CB Nominal output 8 kW Flue connection (diameter) 150 mm Weight +/- 120 kg Recommended fuel Wood Fuel property, max. length 40 cm Mass flow of flue gases 5.4 g/s Flue gas temperature measured in the measurement section 297°C Temperature measured downstream from the flue spigot 353 °C Minimum draught 12 Pa CO emission (13%O 2 ) 0,09 % NOx emission (13%O 2 ) 107 mg/Nm³ CnHm emission (13%O 2 ) 68 mg/Nm³ Particulate emission 21 mg/Nm³ Particulate emission in accordance with NS3058- NS3059 3.44 gr/kg Efficiency 80 % 14 Subject to change because o

  • Dovre 525CB, Appendix 3: Distance from combustible material 525CB - Minimal distance in millimeters                            1 2 09-20008-015 * Protective (insulated) connection pipe Combustible

  • Dovre 525CB, 525CB - Dimensions of fireproof protective plate A B B 09-20002-004 Minimal dimensions of fireproof protective plate A (mm) B (mm) Din 18891 500 300 Germany 500 300 Finland 400 100 Norway 300 100 Subject to change because of technical improvements 17

  • Dovre 525CB, Appendix 4: Diagnostic diagram Problem Wood will not stay lit Gives off insufficient heat Smoke emissions into the room when adding wood Fire in stove is too intense, is hard to adjust Deposit on the glass Possible cause Possible solution Insufficient draught A cold flue usually fails to create sufficient draught. Follow the instructions for lighting in the "Use" chapter; open a window. Wood too damp Use wood with no more than 20% moisture. Logs too large Use small piecesof kindling. Use s

  • Dovre 525CB, Subject to change because of technical improvements 19 Index A Adding fuel 11 Adding wood smoke emissions into the room 18 Air control 11 Air inlets 10 Air leak 13 Air supply for fire 11 Ash pan open 12 Ash removal port 12 Ashes remove 11 B Bearing capacity of floor 5 Burning wood 10 add fuel 11 adding logs 10 appliance is hard to adjust 18 fire is too intense 18 insufficient heat 12, 18 C Carpet 5 Cast iron fire resistant 7 inner plates 7 Cast iron inner plates 7 Chimney connection to 9 height 5 sweep 12 Chinks in appliance 13 Clean glass 13 Cleaning appliance 12 Combustible material distance from 16 Connection measurements 15 Connecti

  • Dovre 525CB, Flue gas mass flow 14 temperature 14 Fog, do not burn wood 12 Fuel adding 11 adding wood 10 necessary amount 12 suitable 9 unsuitable 9 wood 9 G Glass clean 13 deposit 18 H Heat, insufficient 12 Heat,insufficient 18 Hood on the flue 5 I Inner plates cast iron 7 Inner plates, fire-resistant remove 7 Installation measurements 15 K Kindled fire 9 Kindling 18 L Lighting 9 Lubricant 13 Lubricate 13 M Maintenance chimney 12 clean glass 13 cleaning the appliance 12 fire-resistant inner plates 12 lubrication 13 sealing 13 Measurements 15 Mist, do not burn wood 12 N Nominal output 12, 14 O Open ash pan 12 ash removal port 12 do

  • Dovre 525CB, Subject to change because of technical improvements 21 T Tar 11 Temperature 14 U Unsuitable fuel 9 V Ventilation 5 connect supply of outside air 8 rule of thumb 5 Ventilation louvre 5 Vermiculite inner plates 7 W Walls fire safety 5 Warning chimney fire 4, 9, 11 combustible materials 4 fireproof inner plates 9 glass broken or cracked 4, 13 hot surface 4 regulations 4 stove window cleaner 13 terms and conditions for insurance 4 ventilation 4-5 Weather conditions, do not burn wood 12 Weight 14 Wood 9 damp 9 does not keep burning 18 drying 9 right sort 9 storing 9

Related Products and Documents (Cooktop):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Muratec F-160 Operating instructions manual muratec/f-160-CC1.pdf 31 Jul 2023 130
2 TRENDnet TEW-421PC Quick installation manual trendnet/tew-421pc-485.pdf 26 Mar 2023 13 3.33 Mb
3 Tripp Lite NB1150BKTAB Specifications tripp-lite/nb1150bktab-8RV.pdf 01 Sep 2022 2 0.12 Mb
4 ATEN CE-300 Operation & user’s manual aten/ce-300-44U.pdf 07 Apr 2023 33 0.64 Mb
5 Garmin GPSMAP 421 Declaration of conformity garmin/gpsmap-421-5Y7.pdf 05 Aug 2023 1 0.04 Mb
6 Windsor ADMIRAL PLUS ADPJ Operating instructions manual windsor/admiral-plus-adpj-1Q9.pdf 01 Feb 2024 26 1.15 Mb

Similar Resources:

  • New Buck Corporation

    74

    (37 pages)
    FIREPLACE INSERT & FREESTANDINGMODEL 74NON-CATALYTIC UNITFEATURESPREPARATIONS INSTALLATIONOPERATION MAINTENANCE SAFETYBuck StoveSAFETY NOTICEIF THIS HEATER IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAYRESULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION INSTRUCTIONS.CONTACT THE AUTHORITY HAVING JURISDICTION (SUCH AS MUNICIPALBUILDING DEPARTMENT, …
  • GE

    PHP960SM

    (2 pages)
    For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.220578†Note: Check local codes for required breaker sizeImportant: Requires a 5" free area between the bottom of the cooktop to any combustible material, i.e., shelving. Free area not required when i …
  • Electrolux

    EW36IC60I - 36 in. Induction Cooktop

    (4 pages)
    More Energy Efficient Cooking with induction is 70% moreefficient than gas and 20% more efficientthan electric.More ResponsiveCooking with induction is more responsive than gas or electric—you can instantlyadjust the heat to a delicate simmer or bringit to a quick boil.7/11" Dual ElementPowerful and versatile element accom-modates smaller cookware at …
  • KitchenAid

    KGRT600H

    (1 pages)
    IMPORTANT:Rear vent must be installedon all slide-in models forproper ventilation.30" Freestanding and Slide-In Gas Range®PRODUCT MODEL NUMBERS OVERALL DIMENSIONSCABINET OPENING DIMENSIONSSLIDE-IN RANGE COUNTERTOP PREPARATIONKGRT600HKGRT607HKGST300HKGST307HBecause Whirlpool Corporation policy includes a continuous commitment to improveour products, we …
  • KitchenAid

    KECC508RPS00

    (3 pages)
    COOKTOP PARTS1For Models: KECC508RPB00, KECC508RPW00, KECC508RPS00, KECC508RPT00(Black) (White) (S.Steel) (Biscuit)3−05 Litho in U.S.A. (cre)Part No. 818629330" ELECTRICBUILT−INCERAN COOKTOP …
  • Samsung

    FTQ353IWUB

    (72 pages)
    FREE STANDING RANGERefer to the service manual in the GSPN(see rear cover) for the more information.1. Precaution2. ProductSpecication3. Disassembly and Reassembly4. Troubleshooting5. Exploded Views and Part List6. PCB Diagrams7. Schematic Diagrams8. Wiring DiagramBASIC: FTQ353IWUXMODEL: FTQ353IWUBMODEL CODE: FTQ353IWUB/XAA …

Comments, Questions and Opinions: