Ariston Genus 27 Plus Installation Instructions Manual

Ariston Genus 27 Plus Manual Online:

4.75, 590 votes
Ariston Genus 27 Plus User Manual
Ariston Genus 27 Plus User Guide
Ariston Genus 27 Plus Online Manual

Text of Ariston Genus 27 Plus User Guide:

  • 2 TABLE OF CONTENTS 1. GENERAL INFORMATION 1.1 General Instructions 1.2 Overall View 2. INSTALLATION 2.1 Delivery 2.2 Reference Standards 2.3 Siting the Appliance 2.4 Overall Dimensions 2.5 Clearances 2.6 Mounting the Appliance 2.7 Electrical Connection 2.8 Gas Connection 2.9 Water Connections 2.10 Flue Connection 2.11 Room Thermostat Connection 2.12 Electrical/System Diagrams 2.13 Water Circ

  • Ariston Genus 27 Plus, 3 This manual is an integral and essential part of the product. It should be kept with the appliance so that it can be consulted by the user and our authorised personnel. Please carefully read the instructions and notices about the unit contained in this manual, as they provide important information regarding the safe installation, use and maintenance of the product. For operating instructions please consult the separate User’s Manual. Read the instructions and recommendations in these Installation Instructions careful- ly to ensure proper installation, use and maintenance of the appliance. Keep this manual in

  • Ariston Genus 27 Plus, 4 Legend: 1. Air Pressure Switch 2. Fan 3. Main Heat Exchanger 4. Combustion Chamber 5. Ignition Electrodes and Detection Electrodes 6. Burner 7. Automatic air release valve 8. Gas Valve 9. Spark Generator 10. Circulation Pump 11. Motorised Valve with by-pass 12. Main Circuit Flow Switch 13. Safety Valve (3 bar) 14. Low pressure switch 15. Expansion relief valve (6 bar) 16. C.H. expansion Vessel 17. D.H.W. expansion Vessel 18. Drain point 19. C.H.W. Probe 20. Overheat Thermostat 21. D.H.W. Storage with insulation shell Fig. 1.1 1.2 O

  • 5 2. INSTALLATION 2.2 Reference Standards 2.1 Delivery The technical information and instructions provided herein below are intended for the installer / Servicing Technician so that the unit may be installed and serviced correct- ly and safely. There will be two items: 1 - The fully assembled boiler 2 - A separately boxed connection kit WATER REGULATIONS In GB it is necess

  • Ariston Genus 27 Plus, 6 and in the Republic of Ireland in accordance with the following Codes of Practice: WARNING!! The addition of anything that may interfere with the normal operation of the appliance without express written permission of the manufacturer or his agent could invalidate the warranty. In GB this could also infringe the GAS SAFETY(Installation and Use) REGULATIONS. In the Republic of Ireland the installation and initial start up of the appliance must be carried out by a Competent Person in accordance with the current edition of I.S.813 “Domestic Gas Installations”, the current Building

  • Ariston Genus 27 Plus, 7 Fasten the boiler in place using the template and anchors supplied with the unit. It is highly recommended that a spirit level be used to position the boiler so that it is perfectly level. For additional information, please consult the instructions contained in the connection kit and the flue kit. 2.6 Mounting the Appliance 2.7 Electrical Connection Fig. 2.3 Legend: A = Central Heating Return (3/4”) B = Central Heating Flow (3/4”) C = Gas Inlet (3/4”) D = Domestic Hot Water Outlet (1/2”) E = Secondary return (1/2”) F = Domestic Cold Water Inlet (1/2”) 2.4 Overall Dimensions In order to allow for access to the interior of the boiler for maintenance purposes, the boiler

  • Ariston Genus 27 Plus, 8 Central Heating Detailed recommendations are given in BS 6798:1987 and BS 5449-1:1990, the fol- lowing notes are given for general guidance. Pipe Work: Copper tubing to BS EN 1057:1996 is recommended for water pipes. Jointing should be either with capillary soldered or compression fittings. Where possible pipes should have a gradient to ensure air is carried naturally to air release points and water flows naturally to drain taps. The appliance has a built-in automatic air release valve, however it should be ensured as far as possible that the appliance heat exchanger is not a natura col- lecting point for air. Except where providing useful heat, pipes should be insulated to prevent heat lo

  • Ariston Genus 27 Plus, 9 Discharge pipework 1) The tundish must be installed directly below the discharge outlet connection of the boiler. The tundish must also be in a position visible to the occupants, and positioned away from any electrical devices. The discharge pipe from the tundish should termi- nate in a safe place where there is no risk to persons in the vicinity of the discharge and to be of metal. 2) Discharge pipes from the temperature & pressure relief are expansion relief valve are joined together within the

  • Ariston Genus 27 Plus, 10 Air Release Points: These must be fitted at all high points where air naturally collects and must be sited to facilitate complete filling of the system. The appliance has an integral sealed expansion vessel to accommodate the increase of water value when the system is heated. It can accept up to 7 l (1.5 gal) of expansion water. If the heating circuit has an unusually high water content, calculate the total expansion and add an additional sealed expansion vessel with adequate capacity. Mains Water Feed - Central Heati

  • Ariston Genus 27 Plus, 11 100 Flue System The provision for satisfactory flue termination must be made as described in BS 5440-1. The appliance must be installed so that the flue terminal is exposed to outdoor air. The terminal must not discharge into another room or space such as an outhouse or lean-to. It is important that the position of the terminal allows a free passage of air across it at all times. The terminal should be located with due regard for the damage or dis- colouration that might occur on buildings in the vicinit

  • Ariston Genus 27 Plus, 12 In Fig. 2.11 below, several different types of flue systems are shown. For additional information regarding the flue accessories, please consult the Flue Pipe Accessories manual. Fig. 2.11 In calculating the lengths of the pipes, the maximum length must also take into con- sideration the values for the exhaust/air intake end terminals, as well as 90° elbows for coaxial systems. The C52 types must comply with the following requirements: 1. The discharge/intake vent pipes must have the same diameter of ø 80 mm. 2. If an elbow is inserted into the discharge/ventilation system, the calculation of the overal

  • Ariston Genus 27 Plus, 13 2.11 Room Thermostat Connection 1 In order to perform this procedure, remove the boiler casing as indicated in section 3.2. Then proceed as follows: 1 Rotate down the control panel. 2 Open the cover “A” on the left hand side of the compartment. 3 Insert the wire for the connection of the room thermostat into the cable clamp “B”, as indicated in photo 3. 4 Remove the grommet “C” shown in the photo 4, make a hole in it and pass the room thermostat wire through. 5 Remove the link located in the term

  • Ariston Genus 27 Plus, 2.12 Electrical Diagram T D.H.W. Heating + D.H.W. Flue Test operating modes Heating AT BT Legend: AT = High Voltage P.C.B. BT = Low Voltage P.C.B. A = Remote Connector Kit B = Flame Failure L.E.D. C = Insufficient Water Pressure L.E.D. D = Water Temperature Indicator L.E.D.s E = Overheat Thermostat Warning L.E.D. F = System Reset Button G = Selector Knob for Operating Mode H = Domestic Hot Water Temp. Adjustment I = Central Heating Temp. Adjustment J = Wire Connector for Room Thermostat K = Connector for Total Check System L = Selector for Local/Remote Control M = Anti-cycling Device Adjustment for Heating N = Soft-light Adjustme

  • Ariston Genus 27 Plus, 15 1 2 3 4 5 6 17 18 7 8 9 10 22 21 20 19 11 13 14 15 1612 2.13 Water Circuit Diagram Legend: 1. Air Pressure Switch 2. Fan 3. Main Heat Exchanger 4. Ignition Electrodes and Detection Electrodes 5. Burner 6. Gas Valve 8. Spark Generator 7. Automatic air release valve 8. Circulation Pump 9. Motorised Valve with by-pass 10. Main Circuit Flow Switch 11. Safety Valve (3 bar) 12. Low pressure switch 13. C.H. expansion Vessel 14. D.H.W. expansion Vessel 15. D.H.W. Storage with insulation shell 16. D.H.W. Probe 17. Expansion relief valve (6 bar) 18. Temperature/Pressure relief valve (7bar) 19. Magnesium anode 20. C.H.W. Probe

  • Ariston Genus 27 Plus, 16 3. COMMISSIONING 3.1 Initial Preparation MTS (GB) Limited support the initiative. Within the information pack you will find a copy of the logbook. It is important that this is completed in the presence of your customer, they are shown how to us it, and it is signed by them. Please instruct your customer that they must have their logbook with them whenever they contact a service engineer or us. Preliminary electrical system checks to ensure electrical safety must be carried out by a competent person i.e. polarity, earth continuity, resistance to earth and short circuit. Filling the Heating System: Remove the pa

  • 17 The boiler was designed to make regulation easy. To access the adjustment and control area, simply remove the cover by unscrewing the screws “A” and “C” and lift up the small service panels “B1” and “B2” respectively. The first provides access to the control (low voltage) P.C.B., while the second makes it possible to work on the power supply P.C.B.The s

  • Ariston Genus 27 Plus, 18 The boiler is equipped with the following safety systems (see section 3.3 for refer- ences): 1. - Ignition Failure This control signals an ignition failure on the burner 7 seconds after a lighting failure. The L.E.D. “B” will turn on to signal the shutdown status. The system can be reset by pressing and releasing the button “A” after checking to make sure that the gas valve is open. Repeat this process until the burner lights. 2. - Circulation Failure This control signals that the safety pressure switch on the primary circuit has not sensed a pressure of at least 1.5 bar within 40 seconds of the activation of the circu- lati

  • Ariston Genus 27 Plus, 19 3.9 Draining the System Draining the heating system. The heating system must be emptied as follows: - Turn off the boiler; - Open the drain valve for the system and place a container below to catch the water that comes out; - Empty the system at the lowest points (where present). If you plan on not using the heating system for an extended period of time, it is recommended that you add antifreeze with an ethylene glycol base to the water in the heating lines and radiators if the ambient temperature drops below 0°C during the winter. This makes repeated draining of the entire system unnecess

  • Ariston Genus 27 Plus, 20 It is recommended that the following checks be made on the boiler at least once a year: 1 - Check the seals for the water connections; replacement of any faulty seals. 2 - Check the gas seals; replacement of any faulty gas seals. 3 - Visual check of the entire unit. 4 - Visual check of the combustion process and cleaning of the burners if needed. 5 - If called for by check no. 3, dismantling and cleaning of the combustion chamber. 6 - If called for by check no. 4, dismantling and cleaning of the injectors. 7 - Visual check of the primary heat exchanger: - check for overheating in the blade assembly; - clean the exhaust fan if needed. 8 - Adjustment of the flow rate of the g

  • Ariston Genus 27 Plus, Cod. 23 99 84 1516 312 29.8/12.0 27.4/10.3 92.1 88.8 1.1 6.8 0.4 56.9 1.3 3.16 2.35/2.32 136.9 7.27 7.45 55 +5 82/42 7/90 60 40/70 18 12 8 3.5 3.5 3.5 16 7 1 145 3 20 30-37 230 / 50 200 X4D FAST 2 AT 86 47-116-11 GENUS 27 BFFI PLUS 6. TECHNICAL INFORMATION *BS EN 625 **Figures obtained by WRc in accordance with Test Criteria 1-50-220 & 1-50-222 CE Certification Thermal Capacity max/min kW Thermal Power max/min kW Efficiency of Nominal Thermal Capacity % Efficiency at 30% of Nominal Thermal

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Smeg ST45 Instructions for installation and use manual smeg/st45-UCJ.pdf 05 Aug 2023 21
2 Cuisinart SM70BC - 7 Quart Stand Mixer Brushed Chrome Instruction/recipe booklet cuisinart/sm70bc-7-quart-stand-mixer-brushed-chrome-886.pdf 09 Nov 2023 34 1.06 Mb
3 Roland Sound Brush SB-55 Owner's manual roland/sound-brush-sb-55-89K.pdf 17 Dec 2023 68 3.63 Mb
4 Eiki LC-WIP3000 Owner's manual eiki/lc-wip3000-O6A.pdf 28 Sep 2023 80 2.75 Mb
5 NEC AccuSync LCD200VX Operation & user’s manual nec/accusync-lcd200vx-TWX.pdf 15 May 2023 44
6 Pro-Form 350 Operation & user’s manual pro-form/350-5NK.pdf 11 Nov 2023 24

Similar Resources:

  • Green Mountain

    GMGS

    (36 pages)
    GMGSCast Iron SteamGas FiredBoilersINSTALLATION, OPERATION & MAINTENANCE MANUALModels GMGS075E GMGS225E GMGS112E GMGS262E GMGS150E GMGS299E GMGS187E Manufactured by: ECR International Inc. 2201 Dwyer Avenue, Utica, NY 13501 Tel. 800 253 7900 www.ecrinternational.com PN 240009192 REV. L [04/30/2019] …
  • Slant/Fin

    S-34

    (20 pages)
    CONTENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PAGEDimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,3Installation Requirements:Boiler Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Boiler Foundation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Chimney Requirements …
  • TriangleTube

    Prestige Solo 60

    (89 pages)
    Warranty Registration Card must be filled out by the customer and mailed within thirty (30) days of installa-tion in order to gain warranty coverage.When receiving the PRESTIGE Solo unit, any claims for damage or shortage in shipment must be filedimmediately against the transportation company by the consignee.Leave all documentation received with appliance w …
  • Viessmann

    Vitodens 100

    (96 pages)
    VIESMANNInstallation and serviceinstructionsfor heating engineersVitodens 100Type WB1AGas fired wa ll mounted con densing boi lerNatural gas versionFor applicability, see the last pageVITODENS 1005862 757 GB 7/2005 Please k eep safe …
  • Curtis

    WB5N

    (23 pages)
    WB5N Series5 Gallon Water BoilerUSER GUIDE READ AND SAVE THESE INSTRUCTIONS NOTICE TO INSTALLER: Please leave this booklet with the machine.øøøøø /$'$8#/'30/5$07&3 'SFW/$4UZMFBOEDPMPSWBSJFT.PEFM8#/TIPXO …
  • Slant/Fin

    VGH-80-CH

    (32 pages)
    RESIDENTIAL BOILER MODELS VGH-80-CH / VGH-100-CH / VGH-120-CH / VGH-150-CH / VGH-180-CH VGH-90-CO / VGH-150-CO / VGH-200-CO HIGH EFFICIENCY CONDENSING GAS BOILER QUICK CONTENTS FULL TABLE OF CONTENTS............................................................. 3 1.0 SAFETY GUIDELINES ............................................................ …

Comments, Questions and Opinions: