  • Tadiran Telecom AVL-200, SKY - 25 - L1 L1 14 15 1614 16 N T1 T1 T2 T3T2 T3NN17 EF L2 L2L3 L3 L1 L1 14 15 1614 16 N T1 T2 T3 T4NN17 EF L2 L2L3 L3 FR O M OU TD OO R U NIT On/Off Mode Fan L1 L1 14 15 1614 16 N T1 T2 T3 T4NN17 EF L2 L2L3 L3 20 10 9 8 7 6 5 4 3 2 1 21 22 7.4.1 Indoor Unit Terminal Box

  • Tadiran Telecom AVL-200, SKY - 21 - 6.9.3 Air Vacuum and Refrigerant Charge When all the fittings are connected, air must be purged as follows: • Open the service port cap on the suction line valve (large valve). • Connect the vacuum pump to the service port via the pressure gauge and operate the pump for 30 minutes. • Make sure that full vacuum is reached and disconnect the vacuum pump. • Open the liquid line valve (small valve) with an Allen-Wrench for the purpos

  • SKY - 33 - 9. SPARE PARTS LIST 9.1 Spare Parts for Models AVL/R-200, AVL/R-220, AVL/R-240 Refrigerant System Components Parts No. AVL/R-240 AVL/R-220 AVL/R-200 Part Description No. Compressor 1 11020118 11020078 11020118 11020078 Suction Accumulator 2 PCUC100020 PCUC100020 PCUC100020 Suction Accumulator Support 3 11014518 11013

  • Tadiran Telecom AVL-200, SKY - 8 - 2.3 Technical data table – Models AVR-240, AVR-260, AVR-300 AVR-240 AVR-260 AVR-300 Model 50Hz R22 R407C R22 R407C R22 R407C Btu/h 240600 236000 264300 259000 288000 282000 Cooling capacity Watt 70516 69166 77462 75907 84408 82648 Btu/h 243000 235400 266900 259300 290800 283200 Heating capacity Watt 71220 69000 78224 76000 85228 83000 Power Consumption cooling Watt 28000 27600 31000 30500 34000 33400 Power Consumption Heating Watt 26600 26000 29400 28800 32200 31600 Operating Current cooling Amp 47 46.4 50.1 51.

  • Tadiran Telecom AVL-200, SKY - 24 - POWER SUPPLY MAIN SWITCH FROM INDOOR UNIT 1424 68 15 16 17T2T2 J2 7.3 Wiring the Outdoor Unit • Locate the terminal box cover according to the following figures. • Remove the outdoor unit side cover. • Connect the wires to the terminals, in accordance with the color coding and the suitable wiring diagrams. • Connect the outdoor sensor cable, making sure the connector is properly inserted. • Secure the inter-unit electrical cable to the outdoor unit using the clamps. • Make sure that all screws and wires are properly fastened. Loose wires or connections can cause damage and present a fire hazard! • Reassemble the sid

  • Tadiran Telecom AVL-200, SKY - 3 - INTRODUCTION This Service Manual provides comprehensive technical documentation for SKY split air conditioners, and Package air conditioners models AVL/R-200, AVL/R-220, AVL/R-240, AVL/R-260 and AVL/R-300. The information contained in the manual is useful for application engineers, architects, designers and various level service and installation personnel. The manual also contains information about the optional features offered by the SKY series, as well as helpful information for service personnel on split air-conditioners, electrical wiring diagrams, refrigeration cycle diagrams and

  • Tadiran Telecom AVL-200, SKY - 23 - 7. INSTALLING THE CONTROL SYSTEM AND CONNECTING POWER 7.1 Identification of the Components ETN1000/2: Wall mounted thermostat. Features local temperature readout and adjustment, on/off pushbuttons, mode adjustment, fan adjustment and I/R receiving. IRR/1: I/R Room Receiver, wall mounted. Enables the use of the Remote Control unit from another room. Up to 10 Room Receivers can be daisy chained. Optional supply. RT-01: I/R Transmitter (Remote Control). Daily programmable. Optional Supply. I

  • Tadiran Telecom AVL-200, SKY - 10 - 5. AIR FLOW TABLES 5.1 Air flow AVL/R-200 EXTERNAL STATIC PRESSURE-Pa (in.wg) AIR FLOW 300 (1.2) 250 (1) 200 (0.8) 150(0.6) rpm kw rpm kw rpmkw rpmkw CFM M 3 /H 945 2.24 890 1.988201.707501.43 5760 9792 950 2.39 895 2.128301.837601.55 6080 10336 950 2.52 900 2.268351.967701.67 6400 10880 ********** 910 2.328502.027801.72 6720 11424 ********** 915 2.578502.257801.94 7040 11968 5.2 Air flow AVL/R-220 EXTERNAL STATIC PRESSURE-Pa (in.wg) AIR FLOW 300 (1.2) 250 (1) 200 (0.8) 150(0.6) rpm kw rpm kw rpmkw

  • Tadiran Telecom AVL-200, SKY - 20 - 45 45 Evaporator Drain Connection Optional T Rubber Syphon Drain Hose 6.8 Connecting the Drain Hose Connect the rubber syphon to the drain hose connection. See figure below for details. 6.9 Connecting the Refrigerant Lines and Refrigerant Charge 6.9.1 Connecting the Refrigerant Lines • To connect the refrigerant lines use only "L" type sealed, dehydrated copper refrigerant tubing. No other type may be used. The use of other types of tubing will void the manufacturer's war

  • Tadiran Telecom AVL-200, SKY - 30 - 8.2 Poor Cooling Troubleshooting. Symptom Probable Cause Corrective Action 1 Refrigerant flow failure 1. Refrigerant gas shortage. 2. Excessive overcharging of refrigerant. 3. Gas leakage. 4. Clogging of strainer or capillary tube. 5. 4-Way valve is defective. 6. Solenoid 4-Way valve is defective. 7. Compressor is defective. 8. Service valves are not fully open. 1. Charge refrigerant gas. 2. Recharge gas. 3. Repair leakage. 4. R

  • Tadiran Telecom AVL-200, SKY - 19 - A C B D E • Allow free access to the service door, air filter and control box. • Carefully plan the drainage tube path at a minimum slope of 2% avoiding sharp bends or oil traps. • The indoor unit may be installed either hanging from the ceiling or resting on hard surface (i.e. concrete). • Whenever possible, lead the indoor unit drainage tube to the outdoor unit. • Select the installation location according to the abovementioned factors and guidelines. • Mark 4-6 holes on the ceiling, according to the unit's mounting bracke

  • Tadiran Telecom AVL-200, SKY - 5 - 2.1 Technical data table – Models AVL-200, AVL-220 AVL-200 AVL-220 Model 50Hz R22 R407C R22 R407C Btu/h 193400 190000 217000 213000 Cooling capacity Watt 56682 55684 63599 62425 Btu/h 194600 191080 218800 213240 Heating capacity Watt 57034 56000 64127 62500 Power Consumption cooling Watt 23000 22600 25500 25100 Power Consumption Heating Watt 22000 22200 24300 24100 Operating Current cooling Amp 38.6 38.2 42.8 42.3 Operating Current Heating Amp 37 37.2 40.8 40.4 E.E.R-Energy Efficiency Ratio Cool 8.4 8.4 8.5 8.5 C.O.P-Coefficient Of Performance Heat 2.6 2.52 2.64 2.64 Moisture Removal Lit/h 24

  • Tadiran Telecom AVL-200, SKY - 31 - 8.3 Poor Heating Troubleshooting. Symptom Probable Cause Corrective Action 1 Refrigerant flow failure 1. Refrigerant gas shortage. 2. Excessive overcharging of refrigerant. 3. Gas leakage. 4. Clogging of strainer or capillary tube. 5. 4-Way valve is defective. 6. Solenoid 4-Way valve is defective. 7. Compressor is defective. 8. Service valves are not fully open. 1. Charge refrigerant gas. 2. Recharge gas. 3. Repair leakage. 4. Replace strainer. 5. Replace 4-Way valve. 6. Replace solenoid. 7. Replace compressor. 8. Open the valves full. 2 Air circulation

  • SKY - 15 - 6. INSTALATION INSTRUCTIONS 6.1 General All parts and accessories are packed and shipped with appropriate measure to ensure that everything is protected during transportation. The installation team must be familiar with the installation requirements, to exercise due care in handling and to prevent damage to the equipment. The following instructions are in addition to a

  • Tadiran Telecom AVL-200, SKY - 27 - 8. TROUBLESHOOTING GUIDE 8.1 General Troubleshooting. Note: Check for broken wires and loose cable lugs first! Warning: Always unplug the A/C before performing cleaning or maintenance activities. Symptom Probable Cause Corrective Action 1 A/C fails to start. 1. Power supply to unit not connected (LCD display is blank). 2. Fuse Blown ( LCD display is blank). 3. ON/SEND on R/C has not been pressed. 4. A/C does not receive transmitted commands. 5. Elec

  • Tadiran Telecom AVL-200, SKY - 22 - NOTES ......................................................................................................................................................................... ......................................................................................................................................................................... ......................................................................................................................................................................... .......................................

  • Tadiran Telecom AVL-200, SKY - 6 - 2.2 Technical data table – Models AVL-240, AVL-260, AVL-300 AVL-240 AVL-260 AVL-300 Model 50Hz R22 R407C R22 R407C R22 R407C Btu/h 240600 236000 264300 259000 288000 282000 Cooling capacity Watt 70516 69166 77462 75907 84408 82648 Btu/h 243000 235400 266900 259300 290800 283200 Heating capacity Watt 71220 69000 78224 76000 85228 83000 Power Consumption cooling Watt 28000 27600 31000 30500 34000 33400 Power Consumption Heating Watt 26600 26000 29400 28800 32200 31600 Operating Current cooling Amp 47 46.4 50.1 51.2 53.2 56 Opera

  • Tadiran Telecom AVL-200, SKY - 16 - M a i n sw it c h Power supply 1 2 3 4 4 6.2 Standard Accessories User's Manual Syphone 6.3 Electrical Requirements • The air conditioner must be directly connected to an appropriate power supply. • Use only type "C-63" fuses. • Use only a single length power cable, without extensions. • For 3 Phase connections, use 8 wire inter-unit cables. NOTE: The compressor is equipped with oil heating element. Main circuit breaker and power supply must therefore always

  • Tadiran Telecom AVL-200, Contents 1. SKY LINE INTRODUCTION and GENERAL DESCRIPTION ……………………. 03 2. TECHNICAL DATA TABLES ………………………………………………………….. 05 3. REFRIGERATION CYCLE DIAGRAM ……………………………………………... 09 4. AIR FLOW TABLES ……………………………………………………………………. 10 5. ELECTRICAL WIRING DIAGRAM …………………………………………………. 12

  • Tadiran Telecom AVL-200, SKY - 18 - a d b c SLEEVE AIR DUCT DRAIN HOSE AIR INTAKE GRILL CEILING 2 min CONNECTION 6.6 Installing the Indoor Unit Distance Model a mm b mm c mm d mm AVL-200 700 1000 1000 1000 AVL-220 700 1000 1000 1000 AVL-240 800 1000 1000 1000 AVL-260 800 1000 1000 1000 AVL-300 800 1000 1000 1000

  • SKY - 17 - LP HP EVAPORATOR Every 4 m. 8 to 12 m/s 4 m/s or more 0.5% 4 m/s or more 0.5% LP HP 6.4.1 Indoor and Outdoor Unit Location The indoor and outdoor units should be installed as close to each other as possible. Do not exceed the tubing length and height differences as shown in the accompanying table. See figure for additional information.

  • Tadiran Telecom AVL-200, SKY - 34 - 9.2 Spare Parts for Models AVL/R-260, AVL/R-300 Refrigerant System Components Parts No. AVL/R-300 AVL/R-260 Part Description No. Compressor 1 11020078 11020118 11020078 Suction Accumulator 2 PCUC100020 PCUC100020 Suction Accumulator Support 3 11013567 11014518 11013567 4 Way Solenoid Valve 4 1104T075 1104T125 1104T075 Thermal expansion valve 5 1104HGB1 1104HGB2 1104HGB1 Hot Gas Bypass 6 1105DA53 1105DA53 Suction Controlling Pressure Switch 7 14020001 14020001 Refrigerant Filling Valve 8 1106BG78 1106P118 1106BG78 3 Way Service Valve – Suction

  • Tadiran Telecom AVL-200, SKY - 29 - General Troubleshooting (continued). Symptom Probable Cause Corrective Action 9 Water accumulates and overflows from evaporator drain pan. Drain pan pipe or hose is clogged or the spout of drain pan is clogged. Disassemble plastic drain-pipe from spout of evaporator drain pan. Flush with clean water. 10 Water dripping from the condenser base (in Heat mode). Water drain outlet or the spout is clogged. Open condenser cover, clean out water outlet, and clean the base inside thoroughly. 11 Indoor fan is not running at all. 1. Power supply failure. 2. Fan motor relays failure. 3. Fan cont

  • Tadiran Telecom AVL-200, SKY - 32 - NOTES ......................................................................................................................................................................... ......................................................................................................................................................................... .........................................................................................................................................................

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Vita-Mix Mix'n Machine Use and care manual vita-mix/mix-n-machine-24U.pdf 06 Sep 2023 24 0.82 Mb
2 Gladiator GACP15XXMG0 Use & care manual gladiator/gacp15xxmg0-NLE.pdf 09 Jul 2023 24 1.89 Mb
3 Craftsman 315.212300 Owner's manual craftsman/315-212300-34T.pdf 11 Oct 2022 38 1.71 Mb
4 Hitachi P50T501 - 50" Plasma TV Operating manual hitachi/p50t501-50-plasma-tv-O69.pdf 20 Apr 2023 159 15.17 Mb
5 ENERMAX PRO82PLUS II Datasheet enermax/pro82plus-ii-5T2.pdf 18 Sep 2023 2 0.66 Mb
6 Belkin Premium Enclosure 42U Operation & user’s manual belkin/premium-enclosure-42u-83J.pdf 27 Oct 2023 72 8.5 Mb

Similar Resources:

  • Tate

    SmartAire MZ Basic

    (27 pages)
    User Installation Manual SmartAire® MZ Basic 7510 Montevideo Road r1.0-12/11/15 © 2015 Tate Access Floors, Inc. Jessup, MD 20794 SmartAire_mzb_Installation.docx Tel (410)799-4200 1 of 27 SmartAire® MZ Basic User Installation Guide Please Read and Save These Instructions …
  • Gree

    13-04685

    (20 pages)
    Climatiseur individuelMANUEL D’INSTRUCTION ET D’INSTALLATION00526-11/10/11MODÈLES 13-0468513-04686WWW.GREE.CASt-Mathieu-de-Beloeil (Québec) Canada1-866-680-GREE© Tous droits réservés, Sunrise Tradex Corp., 2011Please read this operating instructions thoroughly before using your air conditionerand keep it for future reference.00526-11/10/11MODELS 13- …
  • Samsung

    SCH-R500

    (178 pages)
    SCH-r500 SeriesPORTABLE DUAL MODETELEPHONEUser GuidePlease read this manual before operating your phone, and keep it for future reference.TM_UG_r500_11192007_D2r500_Telus_UG.book Page i Monday, November 19, 2007 9:57 AM …
  • Mitsubishi Electric

    PCA-A·KA4

    (36 pages)
    Air-ConditionersPCA-A•KA4EnglishFrançaisEspañolINSTALLATION MANUALFor safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit.MANUEL D’INSTALLATIONAvant d’installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d’installation de l’appareil exté-rieu …
  • Carrier

    39L

    (116 pages)
    Installation, Operation, andStart-Up InstructionsCONTENTSPageSAFETY CONSIDERATIONS ...................2GENERAL ...................................2INSTALLATION .............................2-64Service Area Requirements ...................2Remote Control Box Option ..................2• REMOTE CONTROL BOX CONDENSATEPREVENTIONMake Electrical Connections ..... …
  • Vivax

    ACP-09CH25AEL

    (204 pages)
    Servisna mjestaJamstveni listHRServisna mjestaGarantni listBiHServisna mestaGarantni listSRServisna mjestaGarantni listCGService pointsUser manualGBUpute za uporabuKorisničko uputstvoNavodila za uporaboUser manualKorisničko uputstvoUdhëzime për përdorimУпатства за употребаСервисни местаГарантен листMAKRoHSACP- …

Comments, Questions and Opinions: