Manualios.com

ASL INTERCOM SMC02G Product Manual

ASL INTERCOM SMC02G Manual Online:

3.25, 2927 votes
ASL INTERCOM SMC02G User Manual
ASL INTERCOM SMC02G User Guide
ASL INTERCOM SMC02G Online Manual

Text of ASL INTERCOM SMC02G User Guide:

  • SMC02G/SMC02F/Variants - Product Manual 5.7.3 Microphone Relative Output Gain (VAR4/VAR12/VAR20 only) Menu: ConfigurationÆSystemÆRouterÆInputsÆMic/LineÆ<I/P #nn – MIC/LINE nn> Æ<Zoned Fire Microphone or Paging Microphone>ÆAudioÆGainÆO/pGains Possible values: –40dB to 0dB (1dB steps) System default configuration: ‘0dB’ Normally all input

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual 5.3.6 Busy and Select Indication LEDs Mode (ACU only) Menu: ConfigurationÆSystemÆRouterÆInputsÆMic/LineÆ<I/P #nn – MIC/LINE nn> Æ<Zoned Fire Microphone or Paging Microphone>ÆCtrlÆLEDs Possible values: ‘Busy Standard’, or ‘Busy Class’ System default configuration: ‘Busy Class’ on Zone Fired Microphones ‘Busy Standard’ on Paging Microphones Typically a Fire Microphone (such as the standard SMC02 units) connected to an ACU (Audio Control Unit) is configured to drive the ‘Busy�

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual 5.6.2 Zone Selection Button Menu: ConfigurationÆSystemÆRouterÆInputsÆMic/LineÆ<I/P #nn – MIC/LINE nn> Æ<Zoned Fire Microphone or Paging Microphone>ÆButtonsÆ<Button # nn> ÆMIC Routing The Microphone Routing button function is for zone selection, i.e. when pressed it selects a specified output or group of outputs to which the microphone audio is to be routed when the PTT button is subsequently pressed. See button operation in Sections “2.2.1 Live Announcements” (page 9), and “2.2.3 Playing Digital Voice Messages (Play DVA Buttons)” (page 14). If a ‘listen-in

  • SMC02G/SMC02F/Variants - Product Manual 9 Mechanical Dimensions Figure 12 Cutout Details BASIC CASE DIMENSIONS RECOMMENDED CUTOUT DIMENSIONS 483 mm 465 mm 232.5 mm 222 mm 232.5 mm 222 mm 50.8 mm50.8 mm 84.5 mm84.5 mm 101.6 mm 177 mm 87.5 mm 76.5 mm 100 mm ALLOW AT LEAST 100 MM FOR MATING CONNECTOR AND CABLE ENSURE CLEARANCE FOR SPEAKER GRILL φ 6.5 mm Issue

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual 12 Reference Documents Additional reference information may be found in the following documentation, available from the “Data Downloads” page of Application Solutions website: www.asl-electronics.co.uk Table 5 Reference Documents Ref. No Title Filename Ref Origin 1 VAR Router Product Description U-0450-1227 ASL 2 VAR Router Operation Manual Refer to ASL quoting the SW version of your unit for appropriate guide ASL 3 VAR-4 Installation Guide 450_VAR-4_Guide ASL 4 VAR8

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual Figure 3 SMC02 – Inserting the Zone Identification Labels LABEL BUTTONS 1-5 • Do not use any sharp tools, as they can damage the front panel. • Do not peel off the plastic cover. ! ! d. Re-fit the front panel back in place using the 11 off screws removed in step 3.a. 4. Ensure that the power supply from the central equipment rack is turned off. 5. Plug the lead assembly (ASL SMCLEAD-5M or SMCLEAD-20M) into the circular connector at the bottom of the SMC

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual 5.7.4 Microphone Equalisation Menu: ConfigurationÆSystemÆRouterÆInputsÆMic/LineÆ<I/P #nn – MIC/LINE nn> Æ<Zoned Fire Microphone or Paging Microphone>ÆAudioÆEQ Possible values: –12dB to +12dB (1dB steps) System default configuration: ‘0dB’ A 3-band equaliser is provided on Mic/Line inputs in order to balance the input tone. This equaliser has a shelving HF (treble) adjustment, shelving LF (bass) adjustment, and a

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual 5.6.3.3 DVA Play Mode Menu: ConfigurationÆSystemÆRouterÆInputsÆMic/LineÆ<I/P #nn – MIC/LINE nn> Æ<Zoned Fire Microphone or Paging Microphone>ÆButtonsÆ<Button # nn> ÆDVA RoutingÆControlÆDVA-Full or DVA-Part Possible values: ‘DVA-Full’, ‘DVA-Part’ System default configuration: ‘DVA-Full’  If the DVA is configured to ‘Play Once’, then this setting should be ‘DVA-Full’. The DVA play mode is only relevant for routing DVAs. The DVA assigned to a ‘DVA Routing’ button may be confi

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual 2.2 Console Operation 2.2.1 Live Announcements ON ALL CALL ONLY OFF NORMAL PAGING MODE ALL CALL MODE 1. If using a SMC02F unit unhook the microphone from its retaining clip.  When a standard SMC02 microphone is in All Call Only failsafe override mode, care should be taken whilst removing the microphone from its mounting clip, to avoid accidentally pressing the PTT switch prematurely. The ALL CALL ONLY LED illuminates to indicate that the SMC02 microphone is in All Call mode. OFFSELECT ON BUSY ZONE SELECT BUTTON 2. If the red BUSY LED against any zone button is illuminated, it indicates that an annou

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual 4.2.2 Fire or Paging Microphone Connection to VAR4/VAR12/VAR20 Input 2 The following diagram shows the connection of the SMC02 to the VAR4/VAR12/VAR20’s Mic/Line input 2 as a Zoned Fire Microphone or Paging Microphone, the latter being the only option for the ‘S’ variants. Figure 6 SMC02 Connection to VAR4/VAR12/VAR20 Input 2 CONTROL PORT-1 ON BASE UNIT PIN 7: ALL-CALL-2 PRESS-TO-TALK PIN 6: 0 V VAR4 / VAR12/ VAR20 SMC02 AUDIO DATA INPUT-2 PIN1 AUDIO - PIN2 AUDIO + PIN9 DATA+ PIN5 DATA- PTT+ PTT- AUDIO OUT- DXP AUDIO OUT+ DXN 6k8 470 PIN 24: REMOTE FAULT-2 FAULT L

  • SMC02G/SMC02F/Variants - Product Manual 1 Description The SMC02G and SMC02F are robust flush mounting Station Master’s Consoles suitable for mounting in 19” DIN equipment racks or other flat surfaces. The SMC02G has a panel mounted gooseneck microphone with a console mounted Push To Talk switch, and the SMC02F has a fist microphone with integral Push To Talk switch. T

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual 10 Safety and Precautions 10.4.1 Packing for Return for Repair All electronics assemblies must be properly packed in ESD protective packing for transport, to prevent physical and ESD damage. Use of non-ESD protective packing for return for repair or service will automatically invalidate the warranty. ! ! 10.1 Environmental The temperature and humidity ranges shown in the specifications for this product must not be exceeded. This equipment must not be installed in an area that is subject to a corr

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual 4.3 Paging Microphone Connection to ACU Inputs 3 to 8 The following diagram shows the connection of the SMC02 to an ACU’s Mic/Line inputs 3 to 8 as a Paging Microphone. Note the ACU can be either the wall mount Intellevac ACU or the rack mount VAR8-ACU. When connected to an ACU the listen-in function is activated in all VAR12 and VAR20 Routers in the Intellevac network, in a similar fashion to when directly connected to a VAR Router. An external audio mixer is however required to mix the AUX Outputs of all VAR12 and VAR20 Routers in the network. This

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual LOUDSPEAKER ANNOUNCEMENT IN PROGRESS SPEAK NOW OK SPEECH LEVEL ON SMC02FSMC02G 6. When the chime has finished (if programmed at the Router), the SPEAK NOW LED will illuminate. If no chime has been programmed then the SPEAK NOW LED will illuminate immediately. Once the SPEAK NOW LED has illuminated you can make the announcement. Recommendations for Optimum Results Speak slowly and clearly while observing the correct positioning of the microphone in relation to your mouth: a. Gooseneck microphone: Speak at a normal conversati

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual 5.5 Configuring the Listen-in Button 5.5.1.1 Listen-in Button Menu: ConfigurationÆSystemÆRouterÆInputsÆMic/LineÆ<I/P #nn – MIC/LINE nn> Æ<Zoned Fire or Paging Microphone>ÆButtonsÆ<Button # nn> ÆSwitchesÆSwitch #4 Listen-in Possible values: ‘Not-Conf’, ‘Listen-in’, or ‘Security’ (not used for SMC02) System default configuration: ‘Not-Conf’ See Listen-in button operation in Section “2.2.4 Listen-in Op

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual Table 3 SMC02 Faults – Intellevac ACU and VAR8-ACU Operational Fault Symptom Fault Description Fault Code(s) Reported and Logged at the Intellevac ACU and VAR8-ACU Suggested Action Total loss of live audio announcement from a single microphone, though the microphone still appears to be functional. Input audio surveillance IPXX AUDIO INPUT XX=01 to 08 • Check audio cabling or power supply cabling between microphone and Router. • Replace microphone console. • Repl

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual Copyright © 2008 Application Solutions Limited Application Solutions Limited Safety, Security and Control Division Unit 17 Cliffe Industrial Estate Lewes - East Sussex BN8 6JL - UK Tel: +44(0)1273 405411 Fax: +44(0)1273 405415 www.asl-electronics.co.uk All rights reserved. Information contained in this document is believed to be accurate, however no representation or warranty is given and Application Solutions Limited assumes no

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual 5.7.6 Microphone Pre-Annoucement Chime Menu: ConfigurationÆSystemÆRouterÆInputsÆMic/LineÆ<I/P #nn – MIC/LINE nn> Æ<Zoned Fire Microphone or Paging Microphone>ÆAudioÆChime Possible chime level: –40dB to 0dB (1dB steps) Possible chime types: ‘Chime-1’ (one chime) ‘Chime-2’: two chimes ‘Chime-3’: three chimes ‘Off’: none System default configuration: ‘Type=Off’ and ‘LEVEL (dB) –12’ A pre-announcement chime may be config

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual 2.2.2 Routing Digital Voice Messages (DVA Routing Buttons) The ‘DVA Routing’ button function enables simple control of a single broadcast route, or complex broadcasts to be set up. For instance when a button is pressed a route can be made that connects any desired combination of audio inputs to any combination of outputs. Audio inputs are typically DVAs, however other types of inputs such as microphone and background music can also be routed. An example of this is a button

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual 11 Spare Parts and Accessories Table 4 SMC02 Spare Part List ASL Part Number Additional Information SMCLEAD-5M SMC02 Lead – 5 metres, with ferrules termination Function: Connects the SMC02 to marshalling box. Location: Bottom of SMC02 Back Box Manufacturer/Supplier: Application Solutions Limited Manufacturer/Supplier Part No.: SMCLEAD-5M Manufacturer/Supplier Description: SMC02 Lead, 5 metres, with ferrules termination SMCLEAD-20M SMC02 Lead – 20 metres, with clean cut end for termination by the installer Function: Connects the SMC02

  • SMC02G/SMC02F/Variants - Product Manual 2 Operation 2.1 Control and Indicators Figure 1 SMC02 Front Panel SMC02G/SMC02GS 6 7 8 5 3 4 910 11 2 1 12 13 06 01 05 11 20 SMC02F/SMC02FS 1 2 12 13 6 9 11 7 8 3 45 10 05 01 06 11 20 Issue: 02 complete, approved Page 6 of 60

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual Issue: 02 complete, approved Page 4 of 60 5.6.5.4 Busy Indication Mode................................................................................................ 41 5.6.6 Cancel All DVAs Button (ACU only) ................................................................................. 41 5.7 Configuring the Microphone Audio Parameters ....................................................................... 42 5.7.1 Microphone Input Gain ...................

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual Service and Warranty Name and Address of Authorised Distributor: This product carries a full warranty. For full details of warranty and service agreements, please contact the Authorised Distributor who supplied the product to you. Exclusions The warranty does NOT cover: 1. Customer misuse, including incorrect installation. 2. Damage other than manufacturing defects. 3. Transit / Courier damage. 4. Incorrect voltage or power supply used. 5. Incorrect in

  • SMC02G/SMC02F/Variants - Product Manual 4.2.1 Fire or Paging Microphone Connection to VAR4/VAR12/VAR20 Input 1 The following diagram shows the connection of the SMC02 to the VAR4/VAR12/VAR20’s Mic/Line input 1 as Zoned Fire Microphone or Paging Microphone, the latter being the only option for the ‘S’ variants. Figure 5 SMC02 Connection to VAR4/VAR12/VA

  • ASL INTERCOM SMC02G, SMC02G/SMC02F/Variants - Product Manual ONSELECT OFF BUSY DVA ROUTING BUTTON 2. Select the required routing by pressing the appropriate Zone Select button programmed for DVA Routing. The green SELECT LED will illuminate to show that the route is active. LOUDSPEAKER AUDIO PLAYING 3. The DVA and other audio sources programmed will then play at the programmed zones. No other action is required at the SMC02. DVA ROUTING BUTTON RESET BUTTON OR 4. DVA routes can either be ended with a reset button, or with the trigger button. To terminate the routing: • Reset button not programmed for this DVA Routi

Related Products and Documents (Security System):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 ATCOM AT530 Operation & user’s manual atcom/at530-JF4.pdf 30 Jun 2023 47 0.73 Mb
2 Husqvarna 101 90 47-26 142RB/152RB Operator's manual ryobi/101-90-47-26-142rb-152rb-8FZ.pdf 29 Mar 2023 29 1.12 Mb
3 Panasonic Toughbook CF-73XCVTSBM Operating instructions manual panasonic/toughbook-cf-73xcvtsbm-W7W.pdf 29 Oct 2023 44 1.85 Mb
4 Danby DMW945SS Owner's manual danby/dmw945ss-3F5.pdf 09 Apr 2024 20 0.54 Mb
5 Nokia 7280 - Cell Phone - GSM Operation & user’s manual nokia/7280-cell-phone-gsm-C53.pdf 15 Jan 2023 105
6 MAGICO S7 Operation & user’s manual magico/s7-Q3K.pdf 13 Jul 2022 12

Similar Resources:

  • Toa

    NX-100S

    (2 pages)
    DESCRIPTIONFEATURESNETWORK AUDIO ADAPTERNX-100S● ● ● ● ● ● ●●●●●●●●Wide-ranging audio bandwidth from 50 Hz up to 14 kHz with high fidelity sound and perfect clarity. Without network delay, audio signals only have a minimal delay of milliseconds.Efficient sub-band ADPCM audio compression technology retains delicate musical instru …
  • Black Widow Security

    BW RAS 120

    (6 pages)
    Standard FeaturesThe following features are standard with yourSecurity/Remote Start:(2) four button remote controlsStatus Indicator (LED)Valet/Service mode switchRemote Start capabilitiesRemote Heater/AC capabilitiesParking Light VerificationSafety Inputs (Brake & hood))Remote Shutdown OperationExtended Range ReceiverMulti-tone siren (120dB)Dual stage im …
  • CompuSTAR

    1WAMR-Fiance

    (14 pages)
    www.compustar.comwww.firstechllc.comEste dispositivo está sujeto a la seccion 15 de las reglas de FCC. El funcionamiento está sujeto a las siguientes condiciones; (1)este dispositivo no puede causar interferencia dañosa. (2)este dispositivo puede aceptar cualquier interferencia recibida, incluso interferencia que pueda causar mal funcionamiento al equi …
  • Heath Zenith

    DUAL BRITE SL-5597

    (12 pages)
    © 2001 DESA International 595-5679-05Dual Brite™Motion SensorLight ControlModel SL-5597Features• Turns on lighting when motion is detected.• Automatically turns lighting off.• Dual Brite™ Timer.• Photocell keeps the lighting off during daylight hours.• LED indicates motion was sensed (day or night).This package includes:2 WireConnectorsGasket6 …
  • Honeywell

    VISTA-32FB

    (64 pages)
    VVVVVVVVIIIIIIIISSSSSSSSTTTTTTTTAAAAAAAA--------3333333322222222FFFFFFFFBBBBBBBB Commercial Fire and BurglaryCommercial Fire and BurglaryCommercial Fire and BurglaryCommercial Fire and Burglary Partitioned Security SystemPartitioned Security SystemPartitioned Security SystemPartitioned Security System with Scheduling with Scheduling wi …
  • Bosch

    DiBos 19

    (4 pages)
    Video | DiBos 19 inch Digital Video Recorders - Version 8 (AMEC)DiBos 19 inch Digital Video Recorders -Version 8 (AMEC) www.boschsecurity.com DiBos uses Bosch’s proven state of the art digitalrecording and communications technology and takesvideo surveillance to a new level. It is an integral partof overall security solutions for a wide rang …

Comments, Questions and Opinions: