  • MCDI exprecium, Page 2 Installation guide for Alarm Receiver Exprecium MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487 Contents Introduction.................................................................................................................................................................................................................3 Main features......................................................................................................

  • MCDI exprecium, Page 3 Installation guide for Alarm Receiver Exprecium MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487 Introduction EXPRECIUM is a full format PC-based alarm receiver card. With two phone line per board, Eprecium gives you the power to turn your PC into a powerful alarm receiver. Starting with one board, you can add boards as your Central grows. With large size memory, fast modem circuit, improved PC bus interface and Caller ID function, Exprecium adds a new dimension to Alarm Receiving and PC Integrated Monitoring Station. The Exprecium receiver card

  • MCDI exprecium, Page 4 Installation guide for Alarm Receiver Exprecium MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487 4. Remove the card from the anti-static bag. Record its serial number, you may be required to supply it in case of a support call. Holding the edge of the card, carefully align the edge connector with the expansion slot. Push the board into the slot firmly and evenly until it is fully seated inside the slot. 5. Visually inspect the connection. If it does not appear to be correct, remove and re-install the board. Secure the card to the computer’s chas

  • MCDI exprecium, Page 5 Installation guide for Alarm Receiver Exprecium MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487 Here is an example of display provided by the COMIRQ utility : COM D400 IRQ 5 : ANY INCOMING SIGNAL Hit "Space Bar" to send ACK ___________________________________________________________________________________ @<CR> @<CR> @<CR> 11:09 02/08 12 1234 51<CR> 11:09 02/08 12 1234 51<CR> 11:09 02/08 12 1234 51<CR> 11:09 02/08 12 1234 51<CR> @<CR> 11:09 02/08 12 4378 O66<CR> 11:10 02/08 12 4378 O66<CR> 11:10

  • MCDI exprecium, Page 6 Installation guide for Alarm Receiver Exprecium MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487 Using WINCOM utility : Within Windows, double click on the WINCOM icon. Select SETTINGS and set the COM port to match the EXPRECIUM COM port. If you only have one Exprecium installed in your system, the COM port address should be COM5. Then click OK. Do not change other parameters since they are already set to match your E

  • MCDI exprecium, Page 7 Installation guide for Alarm Receiver Exprecium MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487 Setting up your Exprecium There is no switches or jumpers to configure your card. All settings are done using the setup program called XPRECIUM.EXE ( provided on the media coming with your card ). This program works under DOS or Windows and can be executed from any disk drive. To use it under Windows, your Windows drivers must be install

  • MCDI exprecium, Page 8 Installation guide for Alarm Receiver Exprecium MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487 Parameter section to the right of Address section Move cursor to desired parameter using UP/DN arrow. Key in each new parameter . After all changes have been entered press <ESC> to go back to Address Section. ONLY in Address Section can changes be saved and sent to receiver. Parameter definition Emulation mode easy sett

  • MCDI exprecium, Page 9 Installation guide for Alarm Receiver Exprecium MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487 By default the Exprecium does not verify printer status on parallel port but sends data to be printed as if a printer was connected to this port. (Yes) option tells the Exprecium receiver to verify and report on the status of the printer connected to its parallel port. A connector is supplied to daisy chain multiple receiver cards ( Exprecium, TLR+ or TLR ) in the sa

  • MCDI exprecium, Page 10 Installation guide for Alarm Receiver Exprecium MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487 JP2,7,9 Connectors to receive Communication Interface Module JP3 Line 1 Phone connector type RJ11. Connect Green and Red only on each connector JP4 Connector for external leds (future use) JP5 Processor jumper pin 2-3 (do not remove) JP6 Line 2 Phone connector type RJ11. Connect Green and Red only on each connector JP8 Dry contacts relay (furure use) J

  • Page 11 Installation guide for Alarm Receiver Exprecium MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487 Formats and characters transmitted Receiving Formats MCDI DTMF FSK Acron Ademco Contact ID Ademco L/S Standard Ademco L/S expanded Ademco Fast / High

  • MCDI exprecium, Page 12 Installation guide for Alarm Receiver Exprecium MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487 HH:mm_ _MM/DD[/YY] _ _ RL_CCC_A<CR> Option 3x1 set by INITLR HH:mm_ _MM/DD[/YY] _ _ RL_ØCCC_AZ<CR> Option 3x1 extended compressed 4x2 HH:mm_ _MM/DD[/YY] _ _ RL_CCCC_AZ<CR> Option 4x1 extended compressed 4x2 Option zero removed 3x1,4x1, extended FORMAT 4x2 HH:mm_ _MM/DD[/YY] _ _R

  • Page 13 Installation guide for Alarm Receiver Exprecium MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487 T : Type(E or R) (Contact ID) Ø : Zero <CR> : EOS (Carriage Return) <ACK> : Data retransmits to computer every 2 second until ACK is received (ACK=06H or $06). @ : Heartbeat signal Re

  • MCDI exprecium, Page 14 Installation guide for Alarm Receiver Exprecium MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487 Warranty The Electronic products of MCDI Inc. are under a five year limited warranty. Material is repaired or exchanged, free of charge, when returned to MCDI service points, post paid. Abused or misused equipment is not covered by this warranty. Power surge damages are not covered by warra

  • Page 15 Installation guide for Alarm Receiver Exprecium MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487 . If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect it until the problem is resolved. . This device does not have any serviceable

  • MCDI exprecium, Page 16 Installation guide for Alarm Receiver Exprecium MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487 conductive pollution which could become conductive due to condensation. Failure to maintain these minimum distances would invalidate the approval. 4) The analogue telecommunications interface is intended to be connected to telecommunication network voltage (TNV) circuits which may carry dangerous voltages. The telephone cord(s) must be disconnected from the telecommunications system until the card has been installed within a host which provides the necessary protection of the operator. If

  • MCDI exprecium, Technical data sheet for “EXPRECIUM” PCI Twin Line Receiver V000911 MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 PH: +514-481-1067 FX: +514-481-1487 Description “EXPRECIUM” is a full format PC-based twin-line alarm receiver card. EXPRECIUM connects to PCI bus of a PC Computer. Its small size fits table top IBM PCs or compatible PC Pentium and up. EXPRECIUM interfaces to two telephone lines, imposing no limit to the number of customers per line. It provides a parallel printer port for direct output without going through PC. With large

Related Products and Documents (PCI Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 stellar labs 50-4609 Manual  stellar-labs/50-4609-S5N.pdf 04 Dec 2023 5
2 ABB -i-Bus-KNX Millenium Reference manual abb/i-bus-knx-millenium-7AU.pdf 24 Jul 2023 103
3 Whistler 2290 Owner's manual whistler/2290-984.pdf 02 Oct 2022 15 2.51 Mb
4 Hitachi WH 7DL Handling instructions manual hitachi/wh-7dl-8YX.pdf 18 Apr 2023 24
5 ViewSonic PS790 Operation & user’s manual viewsonic/ps790-U86.pdf 05 Dec 2023 18 1.29 Mb
6 Ricoh AP4510 Replacement manual ricoh/ap4510-6SP.pdf 22 Mar 2023 2 0.43 Mb

Similar Resources:

  • YASKAWA

    DX100

    (56 pages)
    MANUAL NO. HW0486052YASKAWA ELECTRIC CORPORATIONDX100 OPTIONSINSTRUCTIONSFOR FUNCTIONAL SAFETY UNIT (NSU01)Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.MOTOMAN INSTRUCTIONSMOTOMAN-- INSTRUCTIONSDX100 INSTRUCTIONSDX100 OPERATOR’S MANUALDX100 MAINTENANCE MANUALThe DX1 …
  • TRENDnet

    TEW-503PI

    (15 pages)
    Copyright ©2005. All Rights Reserved. TRENDware International, Inc. TRENDnetTRENDware, USAWhat's Next in NetworkingTEW-501PC/TEW-503PIVersion 05.04.2005108Mbps 802.11a/g Wireless PC Card/108Mbps Wireless PCI AdapterQuick Installation GuideGuide d'installation rapideAdaptateur PCI sans fil 108Mbps/carte PC sans fil 902.11a/g 108 Mbps Kurzanleitun …
  • Adaptec

    ANA-6922A

    (2 pages)
    ADAPTEC DUO10/100 FAST ETHERNETTwo-port ANA™-6922A PCI server adapter forFast Ethernet environments™®Product Highlights■Two connectors supporting separate network segments at full-link bandwidth■Optimized for Pentium, andPentium Pro servers■Each channel operates at independent speeds for maximum flexibility (10 Mbps, 20 Mbps,100 Mbps, or 200 Mbps) …
  • SeaLevel

    Route 56

    (19 pages)
    Part # 5101 Sealevel Systems, Inc P.O. Box 830 Liberty, SC 29657 USA Phone: (864) 843-4343 FAX: (864) 843-3067 www.sealevel.com Route 56. PCI USER MANUAL R …
  • StarTech.com

    PEX2S1P553B

    (10 pages)
    PCI Express Serial and Parallel Adapter 2-Port Serial, 1-Port Parallel PCI Express Dual Profile Combo Card with Breakout CablePEX2S1P553BInstruction ManualManual Revision:10/19/2010For the most up-to-date information, please visit www.startech.com …
  • Quectel

    EC20

    (8 pages)
    TITLEPROJECT1.0EC20 Reference DesignRadom.XIANGMountain.ZHOUCHECKED BYDRAWN BYOFA654321SHEETABCD123456DCBQuectel Wireless SolutionsSIZEVER81 DATE2015/3/30A2Module Interface1. Keep all RESERVED and unused pins unconnected.Notes:2. Pin 73~84 and 117~140 are unused in the design. You can ignore them in schematic and PCB decal.Module Interface3. The DBG_RXD/DBG_ …