  • User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 38 of 46 you might experience data loss when data exchange rate is high. This is because data flow

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 24 of 46 Figure 15 - System Main Menu (Web Page) From Figure 14, System Main Menu (Terminal Screen): Option 1 – Change Command Prefix Symbol: Enters a prefix symbol that works for you, if the current defined prefix has a conflict with your app

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 44 of 46 6 Open <<< Not connected. 8 CTS Clear To Send <<< When hardware flow control is enabled, if this signal is raised, an external device can send data to Local Master Port. 7 RTS Request To Send >>> When hardware flow control is enabled, this signal is raised by the

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 14 of 46 communication equipment, which usually sends responses while receiving data from its serial console port. However, once the system is in System Control Command mode, the system starts to echo user’s typing on the Telnet terminal. Telnet session permits an anonymous user who may only to view the system settings and operate unreserved power outlets and user serial console ports. Please refer to

  • User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 27 of 46 • Web Access: Enable or disable web access to the system. Default to enable. • Telnet Access: Enable or disa

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 30 of 46 Defines a static subnet mask that is a part of your static network address settings. This entry is for your IP network class, which is distinguished by using a subnet mask. • Gateway IP address: Defines a gateway IP address that is a part of your static network address settings. This is your router’s IP address. • HTTP Port Number: Specifies a HTTP port number. Default value is 80.

  • User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 36 of 46 4.5 Serial Console Port Configuration Menu: This section describes serial console port configuration and operating

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 26 of 46 Figure 17 - System Access Control Menu (Web Page) • System(Device) name: Assign a system name, sometimes referred as site or device name. • Date and Time: Enter calendar date and real-time clock. • Serial Port Mode: Configure the Local Master Port to interface type: either to a serial RS-232 port on your work station or an external Modem device. An external

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 18 of 46 powerOutlet6OpStatus .3.2.7.0 Read/Write. Applicable to NPC/NP systems. powerOutlet7OpStatus .3.2.8.0 Read/Write. Applicable to NPC/NP systems. consolePortActiveStatus .3.2.2.0 Short Integer. Applicable to NPC/NC systems. Read/Write. The value indicates which console port is switched (active) to communicate with the local service port or the network interface. The valid va

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 5 of 46 1 System Description 1.1 System Key Features: Model Ethernet (10 based-T) Port Local Master RS232 Port User RS232 Port Buffers for User RS-232 Port NC-16 1 1 16 32 K Bytes for active serial port NC-08 1 1 8 32 K Bytes for active serial p

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 45 of 46 Appendix B System Specifications Item NC-16 NC-08 Power Input 1 Amps Max, 6 watts. 1 Amps Max, 6 watts. Voltage 100 – 240 VAC 100 – 240 VAC Connector Power Cord Power Cord Physical Dimensions 19” X 1.5” X 6.25” (19”-1U) 19” X 1.5” X 6.25” (19”-1U) Console Interface – Local Master Port 1 RS232 Port. DB-9 Female DCE Data: 7 or 8 bits. Stop Bits: 1 or 2

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 7 of 46 Ethernet NC-08/NC-16 system Serial Consoles Port 1 Port 2 Port 3 Port 4 Internet Emails – Send User Data to Euipment LAN Connection Local Serial Console Connection Figure 2 - Illustration of Typical Application

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 11 of 46 2.2 User Privileges and Port Reservations: All user levels, including anonymous (visitor), are able to access the system via a serial connection from your work station to the Local Master port, or via a Telnet session from your work station. • Administration Login: There is only one Administration account on the system. The default name is “admin” and default

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 15 of 46 You must have an account on the system in order to access the system via this method. Without a valid account, you are only able to view the following web page and get a copy of the Help text message. Figure 8 - Web Access Startup Page (NC-16) Upon clicking the Login button, a secured login table is displayed at you work station

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 17 of 46 The MIB (Management Information Base) is a text file describing the internal objects the SNMP agent can display, monitor, and/or modify. Each MIB object is the system variable that has name and an OID, as shown in Figure 11. You need th

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 42 of 46 Figure 31 – Viewing and Changing System Operation Status

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 34 of 46 activities are displayed. “/emailvbs 2” sets to the system to level 2 verbose mode, in which detailed emailing activities are displayed. • Use command “/emailget” to check incoming emails immediately. • Use command “emailsend” to send a test mail immediately 4.4.2 Sending Data to User Serial Console Ports: The user data is placed in the email text body. Each line of the user d

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 40 of 46 • Use the command “/userlist” to view all existing account 4.7 Viewing and Changing Operation Status with a Web Page: Figure 31 shows a web page that lets you to view and change serial console port and power outlet operation status. With the web page, you are able to: • View the current active user serial console ports. As shown in the

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 46 of 46 Appendix C RS-232 To RJ45 Conversion Cables RS-232 — RJ45 (8-pin) C-RJ45-DB9F-4, RJ-45 to RS232 (Female, DCE) cable, 4’. RS-232 — DB9 Female RJ45 (8-pin) Pin No. Signal 1 DCD 2 TxD 3 RxD 4 DSR 5 GND 6 DTR 7

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 2 of 46 Copyright Notice Copyright © 2004 by Synaccess Networks, Inc. The material discussed in this manual is the proprietary property of Synaccess Networks, Inc. AII retains all rights to reproduction and distribution of this document. FCC Warning The Federal Communications Commission has set limits for em

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 4 of 46 Table of Figures Figure 1 - List of System Interface Ports for NC Systems.................................................................................. 5 Figure 2 - Illustration of Typical Application..................................................................................................... 7 Figure 3 - NC-16 Front

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 25 of 46 Option 5 - Configure Serial Console Port: Enters Serial Console Port Configuration submenu. Helpful info: control command “/sshow” displays all serial console port settings.. Option 6 - Setup new or existing accounts: Enters User Account Setup submenu. Select this o

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 23 of 46 Menu selection 3: n account on the system or if you have an account already and want to enu selection 4: on. enu selection 5: . 4.2 System Main Menu: If you do not have a modify your account or delete an account, select option 3. M Lists help informati M Exit menu operation his is a top level system main configuration me

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 43 of 46 Appendix A Serial Console Port Interfaces Local Master Port - DB-9 Female DCE Pin # Name Long Name Direction Description 1 DCD Data Carrier Detect <<< Raised when an carrier communication is established. 2 TD Transmitting Data >>> Serial data stream sent t

  • User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 41 of 46

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 33 of 46 Before a command is executed, a confirmation reply email is sent. The destination of the replying email address is already defined in the Network Configuration Table. Figure 21 shows a reply email is received and displayed at “hotmail” web site. Figure 21 – Reply Email Before a

  • Synaccess NC-16, User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 37 of 46 Figure 27 - Serial Port Setup Menu (Web Page) ************************************************************ * * * * * Port 1 Configuration

  • User’s Manual Synaccess Networks, Inc. www.synaccess-net.com (760) 930 – 0473 Page 13 of 46 2) Higher mask number has higher priority. If an IP is blocked by Mask 3 and the

Related Products and Documents (Switch):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Triumph Adler DC 2062 Instruction handbook manual triumph-adler/dc-2062-52S.pdf 10 Oct 2022 106 1.69 Mb
2 Paradyne 1862 Quick installation instructions paradyne/1862-955.pdf 14 Feb 2024 1 0.12 Mb
3 Star Micronics Multi-Font LC-IOII Operation & user’s manual star-micronics/multi-font-lc-ioii-I4V.pdf 25 Jan 2023 122 5.42 Mb
4 Pioneer Super Tuner III D DEH-P2550 Operation manual pioneer/super-tuner-iii-d-deh-p2550-34L.pdf 13 Mar 2024 96
5 ACRONIS TRUE IMAGE - FOR MICROSOFT WINDOWS SMALL BUSINESS SERVER Datasheet acronis/true-image-for-microsoft-windows-small-business-server-383.pdf 11 Nov 2023 2 0.05 Mb
6 GE 24110 Instruction manual ge/24110-15Z.pdf 16 Aug 2022 16 0.77 Mb

Similar Resources:

  • Extreme Networks

    Summit X450a-24tDC

    (170 pages)
    Extreme Networks, Inc.3585 Monroe StreetSanta Clara, California 95051(888) 257-3000(408) 579-2800http://www.extremenetworks.com ExtremeXOS Summit Family Switches Hardware Installation GuideSummit X150 SeriesSummit X250e SeriesSummit X350 SeriesSummit X450 SeriesSummit X450a SeriesSummit X450e SeriesPublished: April 2008Part number: 100286-00 Rev. 02 …
  • SignaMax

    065-7310F Series

    (16 pages)
    SIGNAMAX 065-1200 SERIES 12-PORT MEDIA CONVERTER USER’S MANUAL 1 Signamax Connectivity Systems 065-7310F series 8-Port 100BaseFX Fiber Switch User’s Guide …
  • LevelOne

    FEP-1611

    (17 pages)
    1 FEP-1611 / FEP-1612 16-Port Fast Ethernet PoE-Plus Switch GEP-1621 / GEP-1622 16-Port Gigabit PoE-Plus Switch FGP-2410 / FGP-2412 24 FE PoE-Plus + 2 GE Combo SFP Switch Quick Installation Guide English Deutsch Français Español Nederlands Dansk Italiano Ελληνικά Português Svenska Slovenščina 繁體中文 한국어 Русски …
  • Juniper

    EX8200 Series

    (4 pages)
    Installing a Line Card in an EX 8200 series SwitchEX 8200 series switches have field-replaceable unit (FRU) line cards that can beinstalled in the line card slots on the front of the switch chassis. The line cards arehot-insertable and hot-removable: You can remove and replace them without poweringoff the switch or disrupting switch functions.Before you begi …
  • Elite Screens

    Kestrel Series

    (6 pages)
    KestrelSeriesVerticalLimitSwitchAdjustmentInstructionsCaution: The Screen’sBottom Black Masking Borderisalreadysettoitsmaximumrisedistance.There is NO extr a bottom black border in the roller. Attempting to increase the bottom blackborder …
  • aci

    CURRENT FIXED SWITCHES Series

    (8 pages)
    Automation Components, Inc.2305 Pleasant View Road | Middleton, WI 53562Phone: 1-888-967-5224 | Website: workaci.comPage 1Version: 6.0I0000787PRECAUTIONS• This product is not intended to be used for Life or Safety applications.• This product is not intended for use in any hazardous or classied locations.• The A/CS2 and A/SCS2 Series Current Swit …

Comments, Questions and Opinions: