  • AirQ ISM-H24CODC, 14 7.5 Pumping down (Re-installation) Procedure 1. Confirm that both the 2-way and 3-way valves are set to the opened position. Remove the valve stem caps and confirm that the valve stems are in the opened position. Be sure to use a hexagonal wrench to operate the valve stems. 2. Operate the unit for 10 to 15 minutes. 3. Stop operation and wait for 3 minutes, then connect the charge set to the service port of the 3-way valve. Connect the charge hose with the push pin to the gas service port. 5. Air purging of the charge hose. Open the low-pressure

  • AirQ ISM-H24CODC, 4 2. Function When the power supply is interrupted and then restore, the air conditioners automatically restore the previous function setting. Tele Remote control (Optional) Maintain the room temperature in accordance with the setting temperature. The mode can be change by the room temperature. The louver can be set at the desired position or swing up and down automatically The function is usually used in rainy days in springtime or damp areas. The fan is turn to low speed (cooling/heating). The unit will be turn off at the seventh hour. The unit will decide the louver direction according to operation mo

  • AirQ ISM-H24CODC, 15 7.6 Re-air purging (Re-installation) Procedure: 1. Confirm that both the 2-way and 3-way valves are set to the closed position. 2. Connect the charge set and a charging cylinder to the service port of the 3-way valve. Leave the valve on the charging cylinder closed. 3. Air purging. Open the valves on the charging cylinder and the charge set. Purge the air by loosening the flare nut on the 2-way valve approximately 45’ for 3 seconds then closing it for 1 minute; repeat 3 times. After purging the air, use a torque wrench to tighten the flare nut to on the 2-way valve. 4. Check the gas leakage

  • AirQ ISM-H24CODC, 26 a) T3 rises to be higher than 12℃. b) T3 rises to be higher than 8℃ and remains for 80 seconds. c) The machine has run for 10 minutes in defrosting. 8.7.7 Defrosting action 8.7.8 Rating capacity test function 1) Set the indoor unit with remote controller as: high fan, 30℃ in heating mode, then press “TURBO” button on controller 6 times or more within 10 seconds(make sure indoor unit receives these signals), the machine will turn into rating capacity test mode, the buzzer will make a “di” sound for 2 seconds continuously. Also

  • AirQ ISM-H24CODC, 13 leakage from the refrigeration cycle. Procedure 1. Recheck the piping connections. 2. Open the valve stem of the 2-way valve counterclockwise approximately 90’, wait 10 seconds, and then set it to closed position. Be sure to use a hexagonal wrench to operate the valve stem. 3. Check for gas leakage. Check the flare connection for gas leakage 4. Purge the air from the system. Set the 2-way valve to the open position and remove the cap from the 3-way valve’s service port. Using the hexagonal wrench to press the valve core pin, discharge for three seconds and then wait for one minute. 5. Use torque wrench to tighten the service port cap to a torqu

  • AirQ ISM-H24CODC, CONTENTS 1. Precaution................................................................................................................................................. 1 1.1 Safety Precaution ................................................................................................................................................ 1 1.2 Warning ...............................................................................................................................................................

  • AirQ ISM-H24CODC, 2 arrives. There is risk of property damage, failure of product, or electric shock.  Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.) There is risk of physical injury, electric shock, or product failure.  When the product is soaked (flooded or submerged), contact an Authorized service center. There is risk of fire or electric shock.  Be caution that water could not enter the product. There is risk of fire, electric shock, or product damage.  Ventilate th

  • AirQ ISM-H24CODC, 16 7.7 Balance refrigerant of the 2-way, 3-way valves Procedure: 1. Confirm that both the 2-way and 3-way valves are set to the open position. 2. Connect the charge set to the 3-way valve’s service port. Leave the valve on the charge set closed. Connect the charge hose with the push pin to the service port. 3. Open the valves (Low side) on the charge set and discharge the refrigerant until the gauge indicates 0.05 to 0.1Mpa. If there is no air in the refrigeration cycle [the pressure when the air condi

  • AirQ ISM-H24CODC, 17 7.8 Evacuation Procedure: 1. Connect the vacuum pump to the charge set’s centre hose. 2. Evacuation for approximately one hour. Confirm that the gauge needle has moved toward -0.1 Mpa (-76 cmHg) [vacuum of 4 mmHg or less]. 3. Close the valve (Low side) on the charge set, turn off the vacuum pump, and confirm that the gauge needle does not move (approximately 5 minutes after turning off the vacuum pump). 4. Disconnect the charge hose from the vacuum pump. Vacuum pump oil, if the vacuum

  • 32 9.1 Indoor Unit Error Display Display LED STATUS E0 EEPROM parameter error E1 Indoor / outdoor units communication protection E2 Zero-crossing signal error E3 Fan speed out of control E5 Open or short circuit of outdoor temperature sensor E6 Open or short circuit of room or evaporator temperature sensor P0 IGBT over-strong current protection P1

  • AirQ ISM-H24CODC, 8.15 Ionizer/Plasma dust collector function(optional) .............................................................................................. 30 9. Troubleshooting ..................................................................................................................................... 31 9.1 Indoor Unit Error Display ................................................................................................................................... 32 9.2 Diagnosis and Solution...............................................

  • 37 9.3.4 Temperature Sensors. Room temp.(T1) sensor, Indoor coil temp.(T2) sensor, Outdoor coil temp.(T3) sensor, Outdoor ambient temp.(T4) sensor, Compressor exhaust temp.(Te) sensor. Measure the resistance value of each winding by using the multi-m

  • AirQ ISM-H24CODC, 21 8.4 Fan-Only Mode 8.4.1 Temperature setting function is disabled, and no setting temperature display. 8.4.2 In this mode, the action of louver is the same as in cooling mode. 8.4.3 The action of auto fan in fan-only mode is the same as auto fan in cooling mode with 24℃ setting temperature. 8.5 Cooling Mode 8.5.1 After starting, the operation frequency of compressor submits to following rule. When the machine is running and ∆T(=room temp. – setting temp.) changes, the frequency of compressor will rise or descend a grade (7 minutes after starting). After start, if ∆T st

  • AirQ ISM-H24CODC, 36 9.3 Key parts checking. 9.3.1. Compressor checking (Model: C-6RZ146H1A) Measure the resistance value of each winding by using the multi-meter. 9.3.2 Outdoor Fan Motor (Model: YDK53-6N) Measure the resistance value of each winding by using the multi-meter. Position Resistance Value Blue - Red Blue - Black Red - Blue 0.452Ω (25) Position Resistance Value Black - Red 113Ω (20) Red -Yellow 193Ω (20)

  • AirQ ISM-H24CODC, 31 9. Troubleshooting Safety Because of there are capacitors in PCB and relative circuit in outdoor unit, even shut down the power supply, electricity power still are kept in capacitors, do not forget to discharge the electricity power in capacitor. Electrolytic Capacitors (HIGH VOLTAGE! CAUTION!) Bulb (25-40W)

  • 20 is 0~50℃. When the unit stops operation, it returns to original factory settings. Displays the malfunction code or protection code. ⑤ Frequency indicator This indicator appears only when the compressor is in operation and indicates the current operating frequency. 8.2.2 LED display control function.

  • AirQ ISM-H24CODC, 8 4. Specification Indoor ISM - H24CODC Outdoor ISM - H24CODC Power supp ly Ph - V - Hz 1,220 - 240V~,50Hz Capacity Btu/h 23000(7000~26000) Input W 2250(620~2650) Rated current A 9.8(2.8~11.8) Cooling EER Btu/w.h, w/w 10.3 , 3.01 Capacity Btu/h 24000(7500~28000) Input W 2070(600~2600) Rated current A 9.0(2.6~11.6) Heating COP W/W 3.41 Moisture Removal L/h 2.4 Max. input consumption W 27 00 Max. current A 15 Starting current A 14.5 Model C - 6R Z146H1A

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 MINN KOTA MK230D Owner's manual minn-kota/mk230d-LKV.pdf 15 Jul 2022 12
2 Sony SLV-X815ME Operating instructions manual sony/slv-x815me-992.pdf 09 Aug 2023 44 0.48 Mb
3 XtendLan XL-ICA-220 Operation & user’s manual xtendlan/xl-ica-220-474.pdf 22 Oct 2022 41
4 Rotronic HygroLog HL20 Operation & user’s manual rotronic/hygrolog-hl20-UDR.pdf 31 Jul 2022 23
5 Lenovo THINKCENTRE 4466 Hardware maintenance manual lenovo/thinkcentre-4466-NLN.pdf 13 Apr 2023 486
6 Panasonic EY7549 Operating instructions manual panasonic/ey7549-O58.pdf 03 Feb 2023 57 7.16 Mb

Similar Resources:

  • Fujitsu

    ART90 Series

    (16 pages)
    OPERATING MANUALART90 SeriesAIR CONDITIONERDUCT TYPESUMOTUWETH FRSAAMPM36912 15 18 21KEEP THIS OPERATION MANUALFOR FUTURE REFERENCEP/N93653500349365350034_Cover 4/25/05, 1:47 PM1 …
  • Sanyo

    KH2442

    (202 pages)
    85464849182000 REFERENCE NO. SM830082FILE NO.TECHNICAL DATA&SERVICE MANUAL1234Section5XH2442 / CH2442XH3642 / CH3642XH4242 / CH4242TH2442 / CH2442TH3642 / CH3642TH4242 / CH4242KH2442 / CH2442KH3642 / CH3642UH2442 / CH2442UH3642 / CH3642SPLIT SYSTEM AIR CONDITIONER OUTDOOR MODEL No. PRODUCT CODE No.CH2442 854 017 21CH3642 854 017 22CH4242 854 017 23 IND …
  • GE

    AEC10

    (32 pages)
    Write the model and serial numbers here:Model # _________________Serial # _________________Find these numbers on a label on the side of the air conditioner.GE is a trademark of the General Electric Company. Manufactured under trademark license.Owner’s Manual and Installation InstructionsAIR CONDITIONERS49-7770 10-16 GEAAEC10AEC12AED10ENGLISH/ESPAÑOLROO …
  • Gree

    Terra

    (2 pages)
    DUCTLESS HEAT PUMPQUICK-START GUIDE: AUTO: COOL: DRY :FAN ONLY: HEATINDOOR UNIT FRONT PANEL DISPLAY:Look here for LED display of systemstatus, setpoint, indoor and outdoor temperatures and malfunction codes. NOTE: Please read the complete owner’s manual carefully before operation.Press to power the unit on or off.Press to select and adjust each mode.Pres …
  • Sharp

    AE-A18EJ

    (20 pages)
    AY -AP18EJAY -AP24EJAY-AP18EJAY-AP24EJAE-A18EJAE-A24EJRINDOOR UNITSPLIT TYPEROOM AIR CONDITIONEROPERATION MANUALOUTDOOR UNIT*Plasmacluster is a trademark of SharpCorporation.• Uses ozone layer friendly refrigerantR410A. …
  • Mitsubishi Electric

    AG-150A

    (56 pages)
    Mitsubishi Electric Air-conditioner Network SystemCentralized ControllerModel: AG-150A Instruction Book1. Safety precautions ............................................................... 12. Product features................................................................... 23. Component names and display screen names.................... 54. User operation …

Comments, Questions and Opinions: