Rittal SK 3302.series Assembly And Operating Instructions Manual
|
10 List of spare parts Rittal cooling unit assembly instructions 47 GB Spare parts for SK 3366.xxx, SK 3377.xxx Key 1 Compressor 5 Condenser fan 10 Evaporator fan 15 Dispatch bag 20 Expansion valve 25 Filter dryer 30 PSA H pressure-operated switch 40 Controller box 45 Louvred grille 1 46 Louvred grille 2 50 Infill panel 55 Controller 71 Temperature sensor 75 Enclosure tray 80 Transforme
Rittal SK 3302.series, 7 Inspection and servicing Rittal cooling unit assembly instructions 39 GB Fig. 78: Disconnect the earthing cable (2) Fig. 79: Clean out the heat exchanger coil and compressor chamber using compressed air (1) Fig. 80: Clean out the heat exchanger coil and compressor chamber using compressed air (2) Fig. 81: Clean out the heat exchanger coil and compressor chamber using compressed air (3)
18 Rittal cooling unit assembly instructions 4 Assembly and connection GB Fig. 27: Electrical wiring plan no. 7 Fig. 28: Electrical wiring plan no. 8 SK 3304.500/.600 M2 X1 L 123 12321 N PE 5 Power M1 1 2 3 M2 1 2 3 M4 1 2 3 2 1 Serial B1 B2 P M4 M 1~ M 1~ M1 C4 6 3 F2 F2 B3 B4 B5 S1 K2 MS1 L1 L2 L2L1 LN PE 1 23 4 5 X2 T1 X3 A2 Kx A1 K1 NTC I red NTC E blue NTC C
Rittal SK 3302.series, 14 Rittal cooling unit assembly instructions 4 Assembly and connection GB Fig. 19: Connection example: Master/slave operation Key 1 Serial interface 2 Serial interface cable 3 Master/slave bus cable (Model No. SK 3124.100) RTT Rittal TopTherm cooling units X1 Supply connection/door limit switch/alarms X2 Master/slave connection Sub-D, 9-pole X3 Serial interface Sub-D, 9-pole St. Sub-D connector, 9-pole Bu. Sub-D jack, 9-pole Adr. Address Fig. 20: Connection example: Door limit switch and master/slave operatio
Rittal SK 3302.series, 12 Rittal cooling unit assembly instructions 4 Assembly and connection GB 4.5 Notes on electrical installation When carrying out the electrical installation, it is important to observe all valid national and regional regulations as well as the provisions of the respon- sible power supply company. Electrical installation must only be carried out by a qualified electrician who is responsible for compliance with the existing standards and regulations. 4.5.1 Connection data – The connection v
Rittal SK 3302.series, 5 Commissioning Rittal cooling unit assembly instructions 21 GB 4.7 Finalising assembly 4.7.1 Installing the filter media The entire condenser in the cooling units is finished with a dirt-repelling, easy-to-clean RiNano coating. In many cases, therefore, the use of filter media is unnecessary, particularly in the case of dry dusts. For dry, coarse dust and lint in the air, we recom- mend installing an additional PU foam filter mat (available as an accessory) in the cooling unit. For air containing oil condensation, we recommend the use of metal filters (also available as an accessory). When used in textile plants with heavy lint contami- nation, lint screens should be use
Rittal SK 3302.series, 7 Inspection and servicing Rittal cooling unit assembly instructions 35 GB Fig. 57: Clean out the heat exchanger coil and compressor chamber using compressed air (2) 7.1.2 Compressed air cleaning SK 3328.xxx, SK 3329.xxx, SK 3332.xxx Fig. 58: Disconnect the power cord Fig. 59: Remove the upper louvred grille (1) Fig. 60: Remove the upper louvred grille (2)
Rittal SK 3302.series, 4 Rittal cooling unit assembly instructions 1 Notes on documentation GB 1 Notes on documentation These assembly instructions are aimed at tradesper- sons who are familiar with assembly and installation of the cooling unit, and at trained specialists who are familiar with operation of the cooling unit. 1.1 Associated documents There are two sets of instructions for the unit types described here: – Assembly and installation instructions enclosed with the unit in the form of a paper document. –
Rittal SK 3302.series, 46 Rittal cooling unit assembly instructions 10 List of spare parts GB Spare parts for SK 3328.xxx, SK 3329.xxx Fig. 84: Spare parts for SK 3332.xxx SK 3328.xxx SK 3329.xxx 90 71 10 40 50 45 20 46 46 45 100 55 5 15 71 1 75 71 71 80 30 101 102 SK 3332.xxx 90 71 15 10 46 100 1 45 50 45 46 20 5 40 55 71 71 71 30 25 75 102 101
Rittal SK 3302.series, 36 Rittal cooling unit assembly instructions 7 Inspection and servicing GB Fig. 61: Remove the upper louvred grille (3) Fig. 62: Remove the lower louvred grille (1) Fig. 63: Remove the lower louvred grille (2) Fig. 64: Remove the infill panel
Rittal SK 3302.series, 7 Inspection and servicing Rittal cooling unit assembly instructions 37 GB Fig. 65: Disconnect the display cable Fig. 66: Push back the display cable and press it through the cable gland (1) Fig. 67: Push back the display cable and press it through the cable gland (2) Fig. 68: Loosen the four screws of the external circuit fan Fig. 69: Remove the external circuit fan Fig. 70: Disconnect the fan connectors (1) Fig. 71: Disconnect the fan connectors (2) Fig. 72: Disconnect the fan connectors (3)
Rittal SK 3302.series, 10 Rittal cooling unit assembly instructions 4 Assembly and connection GB • Loosen the four nuts on the front enclosure half and pull the enclosure forwards by approx. 5 cm. • Loosen the flat-pin connectors of the PE conductor between the two enclosure halves. • Disconnect the fan connection. • Remove the front enclosure tray completely. Fig. 11: Remove the cover • Remove the four spacer bolts. • Cut the supplied sealing tape to the correct length and stick it carefully along the inside of the rear enclosure half so that no gaps are left at the connection points. Fig. 12: Attach the sealing tape • Push the rear enclo
Rittal SK 3302.series, 22 Rittal cooling unit assembly instructions 6 Operation GB 6 Operation You can operate the cooling unit using the controller on the front of the device (page 5, Fig. 1, no. 11). Depending on the model, the unit is equipped with a Basic or Comfort controller. 6.1 Control using the Basic controller For Model Nos. SK xxxx.100/.110/.140 and SK xxxx.200/.210/.240/.300/.310. Fig. 34: Basic controller Key 1 Controller trim panel 2 Temperature setting 3 LED green (“line”) 4 LED red (“alarm”) 5 Reset button 6.1.1 Properties – Three voltage varia
Rittal SK 3302.series, 32 Rittal cooling unit assembly instructions 7 Inspection and servicing GB Fig. 41: Remove the lower louvred grille Fig. 42: Remove the infill panel Fig. 43: Disconnect the connector from the display (1) Fig. 44: Disconnect the connector from the display (2)
Rittal SK 3302.series, 28 Rittal cooling unit assembly instructions 6 Operation GB 6.2.6 Defining system messages for evaluation System messages are shown on the display of the Comfort controller via the displays A1 to A20 and E0. A more detailed explanation of the system messages may be found in section “6.2.8 Evaluating system messages”, page 29. See also Fig. 37 on page 27. Tab. 5: System messages evaluable via relay The system messages A1 – A19 may additionally be evaluated via two floating system message relays. In this way, one of the two system message relays may be allocated to e
Rittal SK 3302.series, 30 Rittal cooling unit assembly instructions 6 Operation GB Tab. 6: Troubleshooting with the Comfort controller Display screen System message Possible cause Measures to rectify the fault A01 Enclosure door open Door open or door limit switch incorrectly positioned Close door, position door limit switch correctly, check connection if necessary A02 Enclosure interior temperature too high Cooling capacity too low/ unit underdimensioned. Error as a consequence of messages A03 to A17. Check cooling capacity A03 Filter monitoring Filter mat soiled Clean or exchange; reset the Comfort controller A04 Ambient temperature too high/too low Ambient temperat
Rittal SK 3302.series, 7 Inspection and servicing Rittal cooling unit assembly instructions 31 GB 6.2.9 Resetting the Comfort controller After the occurrence of faults A03, A06 and A07, you will need to reset the Comfort controller. • Press buttons 1 ( ▲) and 3 (▼) (Fig. 36) simultaneously for 5 seconds. The system messages will disappear and the temperature display will be shown. 7 Inspection and servicing 7.1 General The cooling circuit is designed in the form of a main- tenance-free, hermetically sealed system. The cool- ing unit is filled with the required quantity of coo
Rittal SK 3302.series, 44 Rittal cooling unit assembly instructions 10 List of spare parts GB 10 List of spare parts Fig. 83: Spare parts for SK 3302.xxx Spare parts for SK 3302.3xx 75 40 71 45 25 1 55 100 15 5 90 71 10 SK 3302.xxx SK 3302.3xx 40 100 90 10 15 5 1 55 45 25 20 71 71
6 Operation Rittal cooling unit assembly instructions 23 GB 6.1.2 Operating and error display The Basic controller monitors and controls the cool- ing unit. It indicates the operating and error statuses via the green and red LEDs (Fig. 34, nos. 3 and 4): Tab. 3: Operating and error display of the Basic controller You may also request the overtermperature mes- sage
Rittal SK 3302.series, R Rittal GmbH & Co. KG · Postfach 1662 · D-35726 Herborn Telephone: +49(0)2772 505-0 · Telefax: +49(0)2772 505-2319 · eMail: [email protected] · www.rittal.com 2nd edition 12/07 (04/07) 318 635 Power Distribution Stromverteilung Distribution de courant Stroomverdeling Strömfördelning Distribuzione di corrente Distribución de corriente IT Solutions IT-Solutions Solutions IT IT-Solutions IT-lösningar Soluzioni per IT Soluciones TI System-Klimatisierung System Climate Control Climatisation Systeemklimatisering Systemklimatisering Soluzioni di climatizzazione Climatización de sistemas Schaltschrank-Systeme Industrial Enclosures Coffrets et armo
4 Assembly and connection Rittal cooling unit assembly instructions 15 GB Fig. 21: Electrical wiring plan no. 1 Fig. 22: Electrical wiring plan no. 2 22 21 A1 M1 M2 X1 L1 L2 N PE 1 23 4 5 S1 Mains L 123 1 2 3 2 1 N PE 5 Power S1 Kx M1 1 2 3 M2 1 2 3 M4 1 2 3 2 1 F2 NTC I red NTC E blue Term A2 L1 L2 R1 2 2 8 B1 B2 P F2 M4 M 1~ M 1~ C2 C1 R S F3 C C4 SK 3302.100/.110, SK 3303.100/.110, SK 3302.
Rittal SK 3201.200 Air Conditioner Assembly and operating instructions manual
SK 3201.200 |
Samsung SGHA436 Air Conditioner Operation & user’s manual
SGHA436 |
Pentair 33WC Air Conditioner Instruction manual
33WC |
Haier HWR08XC5-T Air Conditioner Operation & user’s manual
HWR08XC5-T |
LG LWHD1006R Air Conditioner Training manual
LWHD1006R |
Mitsubishi Electric MUCFH-A18WV-E1 Air Conditioner Service manual
MUCFH-A18WV-E1 |
Sharp AY-XP7FR Air Conditioner Operation manual
AY-XP7FR |
Rittal SK 3269.100 Air Conditioner Assembly instructions manual
SK 3269.100 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Raypak | MVB 503 | Brochure & specs | raypak/mvb-503-K23.pdf | 25 May 2023 | 8 | 1.11 Mb |
2 | AEG | Arctis 3194GA No Frost | Operating instructions manual | aeg/arctis-3194ga-no-frost-JUQ.pdf | 27 Sep 2022 | 16 | 0.76 Mb |
3 | Bang & Olufsen | BeoCenter 2 | Manual | bang-olufsen/beocenter-2-2BG.pdf | 24 May 2023 | 28 | 2.05 Mb |
4 | Glen Dimplex Home Appliances Ltd | XOU60F | Specification sheet | glen-dimplex-home-appliances-ltd/xou60f-Z5Z.pdf | 02 Oct 2022 | 1 | 0.05 Mb |
5 | Haier | 21T9G | Operation & user’s manual | haier/21t9g-6UA.pdf | 12 Nov 2023 | 41 | 10.16 Mb |
6 | Grundig | GDP 1750 | Operation & user’s manual | grundig/gdp-1750-312.pdf | 26 Apr 2023 | 44 | 2.14 Mb |
ICP
Packaged Gas/Electric UnitsOwner's Guide to Operating andMaintaining Your Gas/Electric UnitELECTRICAL SHOCK HAZARD.Failure to follow this warning could result inpersonal injury, death, and/or property damage.Disconnect power at fuse box or service panelbefore performing recommended maintenance.FIRE, EXPLOSION, ELECTRICAL SHOCKHAZARD.Failure to follow th …
PGX424040K00A(5 pages) |
Mitsubishi Electric
Air-ConditionersINDOOR UNITPEFY-P-VMH-E-FGBDFEINLPSVINSTALLATIONSHANDBUCHZum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen.MANUEL D’INSTALLATIONVeuillez lire le manuel d’installation en entier avant d’installer ce climatiseur pour éviter tout accident et vous assurer d’une utilisation correc …
PEFY-P-VMH-E-F(128 pages) |
Frigidaire
PRODUCT NO. BASE MODEL NO. SERIES VOLTSFAC053J7A3 FAC053J7A Frigidaire 115BTU-COOLING5200Publication No.5995344982001016-EN/SERVICE /DJH345ROOM AIR CONDITIONERModel No.FAC053J7A©2001 White Consolidated Industries, Inc.All rights reservedFACTORY PARTS CATALOGROOM AIR CONDITIONERWIRING DIAGRAM - # 309103901OWNER’S GUIDE - # 309000825ELECTROLUX HOME PRODUCTS …
FAC053J7A3(12 pages) |
Sunpentown
DUAL-HOSE PORTABLE AIR CONDITIONERUSE AND CARE MANUALWA-9040DE • WA-9040DH • WA-1140DEWA-1340DE • WA-1340DHThank you for purchasing SPT Air Conditioner, please read the Use and CareManual carefully before installing and using this appliance. Keep this manual forfuture reference.
…
WA-9040DE(20 pages) |
Fujitsu
Older homes l New construction homes l Schools l Places of worshipHospitals and medical facilitiesl Restaurants l Computer roomsHotels and motelsl Car washes l Convenience storesFast food chainsl Fire houses l Police stations l Oil rigs l BarsSunrooms and additionsl Warehouses l Nursing homesATM vestibules l Small offices... Hybrid Flex Inverter System …
AOU18RLXFZ(8 pages) |
Frigidaire
Sommairewww.frigidaire.com USA 1-800-944-9044 www.frigidaire.ca Canada 1-800-265-8352Tout sur l’Utilisation et l’entretienEntretien et nettoyage 11Suggestions pour économiser l’énergie 112020218A0885 (June 2009)Enregistrement du produit 44egallabmESons normaux 45ruesitamilcudsnoitcnoFConsignes de sécurité importantes 2-3de votreCon …
FRA184MT2(13 pages) |
Craftsman Laser Level 320.48290#4CPB51 320.48290: Craftsman Laser Level Owner Documentation 320.48290, 9 |
Neumann.Berlin Microphone KFM 100Neumann.Berlin Product Guide: KFM 100 PDF Operating instructions manual - 4KBQZ3 KFM 100, 18 |
GE Air Conditioner AJCQ12ACD#2L683F AJCQ12ACD: GE Air Conditioner Owner Documentation AJCQ12ACD, 3 |
Broan-NuTone Ventilation Hood 463004Ventilation Hood Specification sheet (Broan-NuTone 463004) 463004, 1 |
Mipro Transmitter MT-24User Guide: Mipro MT-24 (953346, Upd.29/08/2023) MT-24, 7 |
Toastmaster Fryer 815UToastmaster Fryer 815U Use and care manual 815U, 16 |
Hama Speakers POCKETHama Speakers POCKET Operating instructions manual POCKET, 163 |
ABB Measuring Instruments FEX300ABB Measuring Instruments FEX300 Original instruction FEX300, 48 |
Philips Hair Removal System LUMEA sc1993LUMEA sc1993 (Hair Removal System ePDF Guide, #75549F) LUMEA sc1993, 94 |
American Standard Thermostat Moments T506.730American Standard Moments T506.730 Guide (Doc Type: Thermostat Installation instructions manual) Moments T506.730, 9 |
Audiomatica Amplifier 44 (Amplifier ePDF User Manual, #R6C7G4) 4, 13 |
Beko Refrigerator LBI 3002Beko Refrigerator LBI 3002 Operation & user’s manual LBI 3002, 41 |