Manualios.com

Allied Data Technologies CopperJet 816 Installation Manual

Allied Data Technologies CopperJet 816 Manual Online:

3.5, 2910 votes
Allied Data Technologies CopperJet 816 User Manual
Allied Data Technologies CopperJet 816 User Guide
Allied Data Technologies CopperJet 816 Online Manual

Text of Allied Data Technologies CopperJet 816 User Guide:

  • Allied Data Technologies CopperJet 816, Chapter 5: Configuring the CopperJet Page 24 After configuring the CopperJet in RFC1483 Bridge mode, you may need to configure your DHCP settings on your local network card. DHCP, which stands for Dynamic Host Configuration Protocol, automatically allocates an IP address on your local networkcard. 5.4.1.1 Configuring DHCP on your networkcard To configure DHCP on a networkcard for a Windows PC, follow the steps below. 1. Click the Start menu. 2. Click Settings -> Control panel. 3. Double-click the Network icon in the Control Panel window. 4. In the Configurati

  • Allied Data Technologies CopperJet 816, Chapter 5: Configuring the CopperJet Page 23 5.4.1 Configuring RFC1483 Bridged One of the most commonly used connections is RFC 1483 Bridged, attached to the Bridge. This WAN connection performs a transparent bridge between the ADSL connection and the LAN connection. The CopperJet does not route any packets. All packets received on one interface (i.e. ADSL) are transparently bridged to the other interface (i.e. Ethernet). Important: DHCP Server need to be disabled when using RFC1483 bridged, attached to the bridge. See section 5.3.4

  • Allied Data Technologies CopperJet 816, Chapter 9: Glossary Page 51 Micro-filter A filter designed to be connected between the ADSL line and every phone that is connected to the line. PPP The protocol used to carry TCP/IP traffic to the ISP across modem and ISDN links. PPP incorporates authentication (username/password checking). Because of its historical use for modem and ISDN users, ISPs favour the use of PPP as an encapsulating protocol for ADSL users. PPP over ATM - RFC 2364 PPP over ATM (PPPoATM) is the most elegant and simp

  • Allied Data Technologies CopperJet 816, Chapter 5: Configuring the CopperJet Page 20 The DNS relay is enabled. Relaying to following DNS servers:212.213.214.215 When finished configuring DNS Relay, go to the Configuration menu and click on Save config to save the new settings into the CopperJet. Note: You need to fill in the CopperJet IP address as DNS server on your network card or configure the DHCP Server and enable the setting: Use Router as DNS Server. 5.3.5.2 Disabling DNS Relay manually To manually disable DNS Relay, go to the Configuration menu an

  • Allied Data Technologies CopperJet 816, Chapter 5: Configuring the CopperJet Page 14 5.3.3 Edit a LAN connection To update or edit your LAN IP address, click on the Edit hyperlink of the LAN connection you want to update or edit. The Default LAN Port page is displayed. This page contains the Default LAN Port table that allows you to: Use DHCP: The CopperJet receives its LAN IP address from an external DHCP server connected to this LAN interface. IP Address: Configure the Primary (default) IP address and subnet mask for the IP interface. Secondary IP Address: Create or configure a Secondary IP address and S

  • Allied Data Technologies CopperJet 816, Chapter 6.2: Configuring Voice over DSL Page 43 6.2.1 ALAW/ULAW coding Syntax: coder <value> <value> can be one of the following: alaw ALAW is in general meant for Europe. ulaw ULAW is in general meant for the US. Example: to select alaw coding add the following line to the [file.initiad] section: coder alaw 6.2.2 Flash on hook timing Because the requirements of flash on hook timing differ a lot per country, the minimum and maximum hook flash time can be configured. Syntax: flashmin <value> Minimum flash-on-hook time in milliseconds after a hook-flash is detected. Below this value no flash nor hook state change is detected.

  • Allied Data Technologies CopperJet 816, Chapter 3: Connecting the CopperJet Page 8 3 Connecting the CopperJet To connect the CopperJet to the computer, you must have installed an Ethernet 10Base-T card in your computer. You need to have a static IP address on your network card that is in the same subnet as the web interface IP address of the CopperJet. The default web interface IP address for Ethernet is 172.19.3.1. For USB, the default IP address is 172.20.3.1. When using the default IP addresses, your network card can have the following IP address 172.19.3.2 with subnetmas

  • Allied Data Technologies CopperJet 816, Chapter 5: Configuring the CopperJet Page 19 5.3.5 Configuring DNS Relay DNS Relay allows you to send DNS requests to the CopperJet instead of the DNS servers at the service provider. The CopperJet relays these requests to specified DNS Servers. The DNS servers can be discovered automatically through DHCP on the WAN interface OR configured manually. 5.3.5.1 Enabling DNS Relay manually To manually enable and configure DNS Relay, go to the Configuration menu and select DNS relay. The DNS Relay page is displayed: By default DNS relay is disabled. To enable and configure DNS relay, sele

  • Allied Data Technologies CopperJet 816, Chapter 2: LED Indicators and back panel Page 7 USB: To connect the CopperJet to the USB port of the PC. Note: not available on all units. Ethernet: To connect the CopperJet to the Ethernet port of the PC, hub or switch. 2.5 Softkey The purpose of the Softkey is to return the CopperJet to its factory default settings. When pressing and holding the button, the lights will start to blink indicating that the default configuration is about to be restored. When keeping the button pressed, the lights will stop blinking and stay on indicating that the default configuration is restored. The softkey can be released and the CopperJet will rest

  • Chapter 5: Configuring the CopperJet Page 18 5.3.4.2 Disabling DHCP Server To disable the DHCP Server, go to the Configuration menu and select DHCP server. The DHCP Server page is displayed. Select Disabled and click on Configure to disable the DHCP Server. The DHCP: disable server and relay agent page is displayed. At the bottom of the page, cl

  • Allied Data Technologies CopperJet 816, Chapter 5: Configuring the CopperJet Page 30 Access concentrator: Some service provider requires this entry. If the service provider does not provide this, leave it blank. Service name: Some service provider requires this entry. If the service provider does not provide this, leave it blank. Authentication: Choose the authentication method provided by your service provider. None: You don’t need to set any authentication. PAP: Password Authentication Protocol, the server sends an authentication request to the remote user that i

  • Allied Data Technologies CopperJet 816, Chapter 9: Glossary Page 48 9 Glossary ADSL Strictly speaking, Asymmetric Digital Subscriber Line defines only a way of transmitting broadband data (at speeds between 64kbps and 8Mbps) between a user’s premises (home or office) and the local telephone exchange. In order to increase the number of customers that it is possible to serve, the upstream speed (from the user) is lower than the downstream speed (to the user), so the service is ‘asymmetric’. The scope of the definition is similar to that of a modem, such as V.90; the format or meaning of the data is not defined (except in the case of G.992.2 (G.lite) where ATM is defined as the

  • Allied Data Technologies CopperJet 816, Chapter 6.2: Configuring Voice over DSL Page 45 the echo canceller only upon detection of a signal which consists of a 2100 Hz tone with periodic phase reversals inserted in that tone, and not disable with any other in-band signal, e.g., speech, or a 2100 Hz tone without phase reversals. The tone disabler should detect and respond to a disabling signal which may be present in either the send or the receive path. The IAD is detecting the tone in both directions. The Phone LED indicates the status of the echo canceller: Stays ON continuously, e

  • Allied Data Technologies CopperJet 816, Chapter 1: Packaging contents 1 Packaging contents The packaging should contain the following parts: All CopperJets CopperJet 81x only CopperJet 82x only Caution! To prevent overheating, make sure that the CopperJet has enough free space on both sides and above to permit free airflow. Page 4

  • Chapter 7: Firmware and configuration management Page 46 7 Firmware and configuration management The CopperJet has both a firmware and configuration file stored in its flash memory. These files cannot be accessed through the WebServer interface. Use the CopperJet Monitor Tool v3.4.5 or newer to access the firmware and configuration profile. Important: do NOT use the Coppe

  • Chapter 5: Configuring the CopperJet Page 31 Auto-configure DHCP server:By default Disabled. When enabled, your Service Provider is able to provide the DHCP Server IP range dynamically based on the subnetmask. This functionality is also known as learning DHCP Server. Default DHCP server range size: Number of IP addresses that are used for the DHCP server. D

  • Allied Data Technologies CopperJet 816, Contents 1 Packaging contents ...............................................................................4 2 LED Indicators and back panel ................................................................5 2.1 CopperJet 816/817 LED indicators....................................................5 2.2 CopperJet 816/817 back panel.........................................................5 2.3 CopperJet 826/827 LED indicators....................................................6 2.4 CopperJet 826/827

  • Allied Data Technologies CopperJet 816, Chapter 6.2: Configuring Voice over DSL Page 42 exchanged between the VoDSL Gateway and IAD to support both POTS (plain old telephone system) and ISDN voice over ATM. CAS: Channel Associated Signaling (CAS) is used in bit- based schemes where dedicated signaling bandwidth is required for every connection. Profile: Select ITU-T (voice over AAL2) or ATM-Forum (AF– voice traffic over ATM (VTOA)). Profile Source and Identifier are only used for BLES signalling (both CAS and ELCP). For voice gateways with an ADPCM only mode (for all UUI values 0..15) the specia

  • Chapter 5: Configuring the CopperJet Page 25 5.4.2 Configuring RFC1483 Routed A RFC 1483 Routed connection is used when your Service Provider delivers a routed connection between the CopperJet and the Service Provider Network. You need to add detailed configuration information about the WAN service that you are creating. This information must be provided by your serv

  • Allied Data Technologies CopperJet 816, Chapter 9: Glossary Page 49 encapsulation used to carry the TCP/IP traffic over the ATM connection and pass the data into the ISPs normal network. In addition, if PPP is one of the encapsulating protocols, the BAS performs the user authentication (perhaps using an authentication server such as RADIUS to verify the username/password combination). Splitting this functionality from the DSLAM increases the implementation flexibility by allowing the connection to the ISP’s IP network (and the PPP authentication, if

Related Products and Documents (Network Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Smeg SY62MX8 User manual manual smeg/sy62mx8-8Q9.pdf 15 Apr 2023 36
2 Havis-Shields Half Size Trunk Tray 1995-2008 Ford Crown Victoria C-TTB-CV Install instructions havis-shields/half-size-trunk-tray-1995-2008-ford-crown-victoria-c-ttb-cv-9I7.pdf 29 Mar 2023 2 0.24 Mb
3 Daewoo BR-350 Instruction manual daewoo/br-350-937.pdf 05 Nov 2023 8 0.43 Mb
4 Desa B50G Owner's manual desa/b50g-334.pdf 08 Feb 2024 16 0.19 Mb
5 Advantech PPC-6150 Operation & user’s manual advantech/ppc-6150-3M5.pdf 06 Jun 2023 80
6 3M 28627 Instruction manual 3m/28627-4BT.pdf 07 Nov 2023 13

Similar Resources:

  • Black Box

    LEH808

    (161 pages)
    Black Box Hardened Managed Ethernet Switch Hardened Managed Ethernet Switch LEH8814, LEH813 Series, LEH812 Series, LEH808 Series CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or Fax 724-746-0746 Mail orde …
  • TPG

    HG658

    (4 pages)
    1Modem Conguration GuideHG658 Conguring in Layer2 PPPoE for Windows 7IMPORTANT MESSAGEYour modem has already been pre-configured, you do not need to follow each step of the set-up guide but should retain this document in case you need to manually configure your equipment.To configure your PC/Laptop with your wireless password including changing your …
  • Grizzly

    Oak Workbench T10157

    (4 pages)
    MODEL T10157OAK WORKBENCHINSTRUCTIONSWARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.� …
  • Nokia

    7450

    (988 pages)
    Nokia — Proprietary and confidential.Use pursuant to applicable agreements. 7450 ETHERNET SERVICE SWITCH7750 SERVICE ROUTER7950 EXTENSIBLE ROUTING SYSTEMQUALITY OF SERVICE GUIDE RELEASE 15.0.R13HE 11974 AAAA TQZZA 01Issue: 01March 2017QUALITY OF SERVICE GUIDE RELEASE 15.0.R1 …
  • Cisco

    Catalyst 4500 Series

    (194 pages)
    Corporate HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706USAhttp://www.cisco.comTel: 408 526-4000800 553-NETS (6387)Fax: 408 526-4100Catalyst 4500 Series Switches Installation GuideDecember 2005 Customer Order Number: DOC-7814409=Text Part Number: 78-14409-08 …
  • Asus

    DSL-N11

    (37 pages)
    EC Declaration of Conformity We, the undersigned, Manufacturer: ASUSTek COMPUTER INC. Address, City: No. 150, LI-TE RD., PEITOU, TAIPEI 112, TAIWAN R.O.C. Country:TAIWANAuthorized representative in Europe: ASUS COMPUTER GmbH Address, City: HARKORT STR. 21-23, 40880 RATINGEN Country: GERMANYdeclare the following apparatus: Product name: 11n Wireless ADSL …

Comments, Questions and Opinions: