  • WayCool 1HP MFA Series, INTRODUCTION ............................................................................................................................3 Why use evaporative coolers in your workplace ............................................................................3 How evaporative cooling works ......................................................................................................3 ABOUT THIS MANUAL ................................................................................................................4 SAFETY INFORMATION........................................................................................

  • WayCool 1HP MFA Series, I ntroduction WHY USE EVAPORATIVE COOLERS IN YOUR WORKPLACE • The WayCool® evaporative cooler requires little space, has a low initial cost, is inexpensive and simple to operate and requires minimal scheduled maintenance. • Due to the design and construction of the cooling pads, cooling efficiency is normally maintained near optimum throughout the life of the pads (approximately two seasons). • In many cases, evaporative coolers are a better solution than mechanical refrigeration systems because they are more economical to operate and maintain, and do not use environmentally sensitive and costly refrigerants. HOW EVAPORA

  • WayCool 1HP MFA Series, About This Manual The intent of this manual is to help you in two ways: to provide you with step-by-step instructions for quick and easy assembly of your product, and to serve as a reference for simple maintenance and questions you may have regarding your product. Read ALL instructions carefully before starting your WayCool®. Pay particular attention to all SAFETY information. Optional equipment contains necessary instructions for assembly and/or operation. The WayCool® evaporative cooler is labeled with a serial number. The serial number is located inside the unit on the aluminum frame, behind the switch. Removal of the serial number label will void all warr

  • 5 Safety Recommendations PLEASE NOTE Minimum inlet pressure is 10 PSI; maximum inlet pressure is 100 PSI. Never leave unit unattended while in operation. READ AND SAVE THESE INSTRUCTIONS! This is an electric device with moving components. There is the possibility of fire, electric shock or injury to persons. Ensure all the safety recommendations are adhered to in order to minimize this

  • WayCool 1HP MFA Series, Description The WayCool® evaporative cooler is a completely self-contained, portable unit capable of delivering 40 MPH velocity of air with a temperature drop of up to 20 degrees F. The unit is composed of: • Level-controlled water supply system • Cooling pad assembly • Motor-driven blower and ductwork • Controls • Frame and housing The reservoir is made of high impact ABS plastic and holds approximately 24 gallons at normal operating level (about 5" deep). A float-operated valve automatically maintains proper water level when the unit is connecte

  • WayCool 1HP MFA Series, Water Supply System The reservoir can be supplied continuously with an ordinary garden hose by attaching the supplied hose adapter to the fill connection, or it can be filled manually. With a continuous water supply connected, the float valve in the reservoir (like the one in your toilet tank) rises and falls with the water level. A linkage attaches the float to the shutoff valve in the fill connection. As the water level rises to normal operating level (about 5" deep), the float valve shuts off the water s

  • WayCool 1HP MFA Series, Water Supply System cont'd A drain in the reservoir allows you to drain the unit for cleaning and maintenance. A drain cap on the underside of the aluminum tray covers the drain during operation. Make sure the cap is in place before you fill the reservoir. The drain cap should be finger-tightened only. The pump is attached to a bracket, which in turn is fixed to the blower housing. The bracket holds the pump in its proper position on top of the foam filter and slightly above the bottom, allowing sufficient space for water to enter the pump suction. The pump can be easily removed and replaced with the services of a qualified electrician. A small plas

  • WayCool 1HP MFA Series, Cooling Pad Assembly The cooling pads are critical for proper, efficient cooler operation. They are made of laminated cellulose (paper) fibers and arranged to give a large surface area for evaporation and to provide a rigid structure. The shape of the cells allows high velocity airflow through the pad at a minimum pressure drop. At the same time, the air passages between the cells force the incoming air to impinge on the wet cell surfaces and maximize evaporation. The WayCool® evaporative cooler a

  • WayCool 1HP MFA Series, Blower and Ductwork The WayCool® evaporative cooler uses a belt-driven, 1 HP electric motor to drive a centrifugal blower. The blower draws room air through the cooling pads and discharges the cooler air through the spout, displacing the warmer air with cooler air and decreasing the temperature. The blower is secured to the top of the frame and hangs upside down to direct the air out the top of the unit. Brackets on each side of the blower casing secure the blower to the frame and hold it in position. The electric motor is bolted to a metal bracket on the blower casing. A V-belt connects the pu

  • WayCool 1HP MFA Series, Control The WayCool® control switch is mounted on the outside of one frame leg. It has the following positions: OFF power is off to the blower motor and the pump motor. LOW VENT the blower runs at low speed and the pump is OFF. HIGH VENT the blower runs at high speed and the pump is OFF. Use this setting to quickly dry the cooling pads for removal and cleaning. LOW COOL the blower runs at low speed and the pump is on. Use this setting for low cooling loads. HIGH COOL the blower runs at high speed and the pump is on. Use this setting for maximum cooling. PUMP ONLY pump is on and the blower is off. Use this setting during startup to first saturate th

  • WayCool 1HP MFA Series, Operation and Maintenance cont'd UNPACKING AND INITIAL SETUP The WayCool® is shipped upright in a corrugated container. The unit is fully assembled and ready for service except for thoroughly cleaning manufacturing dust from the cooling pads before running it for the first time. CAUTION Be careful when you move the unit while it is in the shipping container and when moving it around with the container removed. Avoid jarring or dropping the unit. 1. With the unit in the upright position as marked on the container, use a sharp knife or scissors to cut the straps that wrap the shipping container. Do not discard the container until you have thoroughly inspe

  • WayCool 1HP MFA Series, Operation and Maintenance cont'd REGULAR CLEANING The frequency with which the WayCool® should be cleaned will depend on the environment in which it is used. The more dirty the environment the more often it will need cleaning. In most cases the WayCool® will need to be cleaned weekly. CAUTION The pads should be dry before you handle them, as they are stronger when dry than when they are wet and less susceptible to damage. If they are wet, run the unit in the HIGH VENT position until they are dry. After cleaning, let the pads air dry before you replace them. 1. Turn the switch

  • Troubleshooting COOLING PADS NOT WETTING 1. Ensure there is water in the reservoir. 2. Ensure the motor switch is in the START position and the pump switch is in the ON position. 3. Ensure the pump is running. 4. Pump is running but no water: a. Ensure hose is connected. b. Inspect and clean the pump discharge filter. c. Inspect and clean the pump intake filter. d. Ensur

  • Options and Accessories Your WayCool® can be purchased with certain options and/or accessories, and some of these can be retrofitted after the initial purchase. Instructions are included with all equipment purchased separately. Options available at time of purchase only: • Oscillating spout Options and accessories available at time of purchase or after purchase: • Pneumatic wheels • Wat

  • WayCool 1HP MFA Series, OSCILLATING SPOUT The oscillating spout is operated by a four RPM gear motor that delivers 50 in/lbs. of torque. As the gear motor rotates, the spout oscillates in a 110-degree arc, which cools an area of about 9500 square feet. The design of the oscillator requires the spout to sit loosely on top of the unit. Do not place hands or any other object in the spout while unit is operational! Do not attempt to stop spout from oscillating! Options and Accessories cont'd Oscillator Assembly IF UNIT DOES NOT OSCILLATE 1. Ensure the unit is plugged into a standard GFCI-protected 120-

  • WayCool 1HP MFA Series, Warranty 17 All information, illustrations and specifications provided here are based on the latest product information available at the time of printing. Product specifications subject to change. Schaefer Ventilation Equipment, LLC Schaefer Limited Warranty Policy Schaefer Ventilation Equipment, LLC (SVE) provides the following limited warranty from the date of invoice to the initial purchaser of our products or to its customer with a dated proof of purchase: I. Two-year coverage (unless otherwise indicated below) applies to all products, components and as

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Avaya T7000 Operation & user’s manual avaya/t7000-6NI.pdf 26 Nov 2022 70
2 PYLE Audio PDLB372 Installation manual pyle-audio/pdlb372-3LP.pdf 28 Aug 2022 4
3 Omron E3JM - Datasheet omron/e3jm-8H8.pdf 13 Dec 2022 10
4 MSI Wind Top AE2010 Operation & user’s manual msi/wind-top-ae2010-6ID.pdf 09 Mar 2023 40
5 Waterline UBBU60FZA Manual for installation and user manual waterline/ubbu60fza-RZ2.pdf 03 Apr 2024 12
6 AirLive WFP-101UV2 Operation & user’s manual airlive/wfp-101uv2-FT3.pdf 20 Oct 2023 106

Similar Resources:

  • GE

    AJCH10DC

    (3 pages)
    AJCH10DC—”J Series” High Mount Cool UnitCreated 1/98GE AppliancesNote: When installing units in through-the-wall applications. Do not restrict air flow areas.2615-5/816-7/8Wall Case Dimensions (in inches)Tandem230/208V15 AmpRRTotal capacity and E.E.R.ratings are calculatedbased on the Associationof Home ApplianceManufacturers’ standards.Listed byUnd …
  • Panasonic

    CS-A18BD3P

    (102 pages)
    1 SERVICE INFORMATION 3 2 FEATURES 4 3 SPECIFICATION (HEAT PUMP TYPE) 7 4 SPECIFICATION (COOLING ONLY TYPE ) 8 5 TECHNICAL DRAWING 9 6 CIRCUIT DIAGRAM 11 7 OPERATING INSTRUCTION 22 8 REFRIGERATION CYCLE 24 9 OPERATION RANGE 25 10 PIPE LENGTH 26 11 OPERATING CHARACTERISTIC 28 12 FAN PERFORMANCE 29 13 SAFETY DEVICE 30© 2002 Matsushita Industrial Corporation …
  • Parker

    LOC

    (46 pages)
    Air Oil CoolersLOC Cooling System for industrial Use Installation and servicing manualaerospaceclimate controlelectromechanicalfiltrationfluid & gas handlinghydraulicspneumaticsprocess controlsealing & shielding …
  • Mitsubishi Electric

    SUZ-M25VA

    (52 pages)
    TECHNICAL & SERVICE MANUALR32[Model Name]SUZ-M25VASUZ-M25VA-ETSUZ-M35VASUZ-M35VA-ETSUZ-M50VASUZ-M50VA-ETSUZ-M60VASUZ-M60VA-ETSUZ-M71VASUZ-M71VA-ETCONTENTS1. COMBINATION OF INDOOR AND OUTDOOR UNITS .....22. SAFETY PRECAUTION ....................................23. PARTS NAMES AND FUNCTIONS ................104. SPECIFICATION ............................... …
  • Frigidaire

    FAC055K7A3

    (12 pages)
    ROOM AIR CONDITIONERModel No.FAC055K7A3©2002 Electrolux Home Products, Inc.All rights reservedFACTORY PARTS CATALOGROOM AIR CONDITIONERWIRING DIAGRAM - # 309341601OWNER’S GUIDE - # 309000825ENERGY GUIDE - # 309367414ELECTROLUX HOME PRODUCTS, INCP.O.BOX 212378, AUGUSTA, GA 30917PRODUCT NO. BASE MODEL NO. VOLTS BTU-COOLINGFAC055K7A3 FAC055K7A 115 5450 BTUMA …
  • Fujitsu

    ASYG30LFCA

    (24 pages)
    SPLIT TYPEROOM AIR CONDITIONERWALL MOUNTED TYPEIndoor unit Outdoor unitASYG30LFCA AOYG30LFTCONTENTSSPECIFICATIONS. . . . . . . . . . . . . . . . . . .1DIMENSIONS . . . . . . . . . . . . . . . . . . . . . .2REFRIGERANT SYSTEM DIAGRAM. . . .3CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . .4ERROR DETECTION . . . . . . . . . . . . . . .5INDOOR PCB CIRCUIT DIAGR …

Comments, Questions and Opinions: