  • Sola HD S4K2U-5C Series, 30 | 4.0 Operation 4.4 Manual Bypass Press the Standby/Manual Bypass button once and hold it for about 2 seconds while the UPS is in Utility (V ac) Mode. The UPS will transfer the connected loads to the internal bypass. If the internal bypass is not available due to mains power problems, pressing this button once will be ignored. Bypass operation is indicated by an audible alarm and illuminated amber Bypass indicator. If other indicators are illuminated, refer to “8.0 Troubleshooting”. 4.5 Shut Down the S4K2U-5C 1. Transfer the UPS to manual bypass by pressing the Standby/Manual Bypass button once (hold it for about 2 seconds). If manual bypass is not available, dis

  • Sola HD S4K2U-5C Series, 28 | 3.0 Control & Indicators 3.2.2 Load Level Indicators The Load Level indicator is composed of ve LED bars that illuminate to indicate the relative load on the UPS output in 25% increments (± 5%). The load level indicator will illuminate as shown in Figure 25. ON OFF OFF OFF OFF ON ON OFF OFF OFF ON ON ON OFF OFF ON ON ON ON OFF ON ON ON ON ON 0 - 25% Overload 76 - 100% 51 - 75% 26 - 50% Figure 25: Load Level indicators 3.2.3 UPS Status Indicators UPS status is indicated by ve symbols: Fault indicator, Ac Input indicator, Battery indicator, Inver

  • Sola HD S4K2U-5C Series, S4K2U5C SERIES USER MANUAL | 11 1000 VA models 2000 VA models C14 Input Receptacle External Battery Connector Cooling Fan Input Circuit Breaker C13 Output Receptacles IntelliSlot Port USB Port Terminal Block Communication C20 Input Receptacle External Battery Connector Cooling Fan C13 Output Receptacles IntelliSlot Port USB Port Terminal Block Communication Input Circuit Breaker 3000 VA models C20 Input Receptacle Output Circuit Breakers Cooling Fan C13 Output Receptacles IntelliSlot Port USB Port Terminal Block Communication C19 Output Receptacle Input Circuit Breaker External Battery Connector Figure 2: S4K2U-5C

  • 8 | Important Safety Instructions Glossary of Symbols Risk of electrical shock Indicates caution followed by important instructions Ac input Ac output Requests the user to consult the manual Indicates the unit contains a valve-regulated lead acid battery Recycle Dc voltage Equipment grounding conductor Bonded to ground Ac voltage ON/Alarm Silence/Battery Test OFF/Bypass WEEE ! i Pb

  • Sola HD S4K2U-5C Series, 20 | 2.0 Installation 7. Fasten inner members (pulled from the bracket assemblies in Step 2) to both sides of the UPS with eight M4 screws provided in this kit. Make sure that the retaining latch is near the rear of the UPS as shown in Figure 12. M4 screw (8 pcs) Retaining latch Inner member UPS Figure 12: Installing inner members 8. Use M4 screws to install ears on both sides of the UPS as shown in Figure 13. M4 screw (8 pcs) Ear (2 pcs) UPS Figure 13: Installing ears 9. Insert the UPS, with inner members attached, into the bracket asse

  • Sola HD S4K2U-5C Series, S4K2U5C SERIES USER MANUAL | 45 10.0 Warranty & Support 10.1 Warranty Information Please see the “Terms & Conditions of Sale”. 10.2 Technical Support Phone: (800) 377-4384 or (847) 268-6651 E-mail: [email protected] Web site: www.solahd.com

  • 32 | 5.0 Communication 5.2.1 Conguration Program Accessing the conguration program via USB is a new feature of the S4K2U-5C. For most users, the factory default settings will be adequate. This section illustrates the features available for modication, as well as the factory default settings. The USB conguration program allows these features of the S4K

  • Sola HD S4K2U-5C Series, 22 | 2.0 Installation 2.5.2 Ac Input/Output Hardwire Installation ! CAUTION This installation must be performed by competent electrical personnel and wired in accordance with local and national electrical codes. Installation Considerations: On start-up, the UPS will take a half cycle inrush current of up to 3 times the rated current. This must be taken into account when selecting the overload protection device at the input mains supply distribution point. To avoid random tripping on startup, we recommend that the input mains supply be protected with a MCB (Mechanical Circuit Breaker) capable of withstanding this initial inrush. The mains in

  • Sola HD S4K2U-5C Series, S4K2U5C SERIES USER MANUAL | 33 5.3 Terminal Block Communication The terminal block includes eight pins, as shown in Figure 26. 1 2 3 4 5 6 7 8 Any Mode Shut Down Battery Mode Shut Down Battery Mode Low Battery Figure 26: Terminal block layout 5.3.1 Any Mode Shutdown The purpose of Any Mode Shutdown is to shut down the UPS output by turning o the rectier, inverter, and static bypass switch so that there is no power to the loads. Any Mode Shutdown can be operated locally and remotely, as described as follows: • Local Any Mode Shutdown can be performed by shorting Pin 1

  • Sola HD S4K2U-5C Series, S4K2U5C SERIES USER MANUAL | v 5.0 Communication 31 5.1 IntelliSlot Communication Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 5.1.1 MultiLink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 5.2 USB Port Communication . . . . . . . . . . . . . . . . . .

  • Sola HD S4K2U-5C Series, While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Oce. All other product or service names are the property of their registered owners. ©2012 EGS Electrical Group, LLC. All rights reserved. Specications are subject to change without notice.

  • Sola HD S4K2U-5C Series, 14 | 1.0 Product Description 1.5.3 Battery Mode The S4K2U-5C enters Battery Mode when mains power fails or is outside acceptable values. The battery system supplies power through the dc-to-dc converter to the inverter to generate clean ac power for the connected loads. When the S4K2U-5C enters Battery Mode, the UPS sounds a half-second beep at 10-second intervals. When approximately 2 minutes of run time remains, the beeps sound every 5 seconds to warn that the battery is getting low (this low battery warning is user-congurable). In Battery Mode, the Ac Input indicator goes o and the Battery Level indicators illuminate. Each Battery Level indicato

  • Sola HD S4K2U-5C Series, 36 | 7.0 Maintenance 7.0 Maintenance This section describes replacing the internal battery pack, precautions, and checking the UPS’s status and functions. 7.1 Replacing the Internal Battery Pack The S4K2U-5C is designed to allow properly trained and qualied service personnel to replace the internal battery pack safely. Read the “Battery Safety Notes” on page 7 before proceeding. Contact your SolaHD representative to obtain the part number and pricing of the appropriate replacement battery pack. Replace batteries with the same type and number of batteries or batte

  • Sola HD S4K2U-5C Series, 18 | 2.0 Installation 2.4.2 Rack Installation NOTES: • When the S4K2U-5C is installed in a rack, it must be supported by a shelf, brackets, or slide rails on each side. The factory-supplied ears cannot support the weight of the UPS. They are used to move the UPS into and out of the rack and to attach the UPS to the rack. • Mounting hardware and slide rails are sold separately. Contact your local SolaHD representative for these options. To install a S4K2U-5C in a rack: 1. Unpack the two bracket assemblies and mounting hardware from th

  • 44 | 9.0 Specications Table 13: Operating Temperature Parameters Ambient temperature +25°C to +30°C [+77°F to +86°F] +30°C to +35°C [+86°F to +95°F] +35°C to +40°C [+95°F to +104°F] Maximum output power factor derating at maximum load 100% to 93% 93% to 86% 86% to 79% Table 14: Battery Backup Times Number of Batteries/Cabinets Load % of Capacity Model Rating 1000 VA 2000

  • S4K2U5C SERIES USER MANUAL | 41 Table 10: Troubleshooting Problem Cause Solution Fault and Bypass indicators and all LED segments of the Battery Level indicator are illuminated UPS is overloaded or the load is faulty Check the Load Level indicator and remove non-essential loads. Recalculate the load and reduce the number of loads connected to the UPS. Check the l

  • Sola HD S4K2U-5C Series, 24 | 2.0 Installation 4. Connect the input power source line, neutral, and ground cables to the input line (L), neutral (N), and ground (PE) terminals on the UPS I/O terminal block and tighten the xing screws (see Figures 18 and 19). 5. Connect the UPS output line, neutral and ground cables to the output line (L), neutral (N), and ground (PE) terminals on the UPS I/O terminal block and tighten the xing screws (see Figures 18 and 19). Output cable Input cable Figure 18: I/O Cable placement Figure 19: UPS I/O terminal block 6. Use two rear panel mounting screws to install Base 2 to the UPS rear panel, as shown in Figure 20.

  • Sola HD S4K2U-5C Series, S4K2U5C SERIES USER MANUAL | 21 Inner Member Front Member Insert Figure 14: Insert the UPS 10. Through the ears, use M5 screws provided in this kit to secure the front of the UPS to the rack vertical rails to prevent the UPS from sliding out of position. 11. If optional external battery cabinets are connected to the UPS, they can be placed all on one side of the UPS or stacked beneath the UPS. The installation procedures are the same as those of the UPS. NOTE: Up to four external battery cabinets can be co

  • Sola HD S4K2U-5C Series, 40 | 8.0 Troubleshooting 8.1.2 Audible Alarm An audible alarm will sound in conjunction with the visual indicators to indicate a change in UPS operating status. The audible alarm will sound as described in Table 9. Table 9: Audible Alarm Descriptions Condition Alarm Battery discharge Half-second beep every 10 seconds Low battery Two half-second beeps every 5 seconds UPS fault, load on bypass 1-second beep every 4 seconds UPS fault, no power to load Continuous Overload Half-second beep every half second Battery replacement 2-second beep every 60 seconds Battery loss Continuous Wiring problem (including line-to-neutral reversal or a loss of proper grounding for UPS) C

  • Sola HD S4K2U-5C Series, 34 | 5.0 Communication NOTES: • A current-limited source for the optocoupler (+12 V dc, 50 mA) will be available from the UPS. • The connection to the S4K2U-5C for remote connection will be via terminal block connector. • Battery mode shutdown wiring will follow local wiring codes and laws. • This signal must last for 1.5 seconds or longer. • A battery shutdown signal will not cause an immediate shutdown. It will start a 2 minute shutdown timer. This timer cannot be stopped once triggered. If mains power returns during this countdown, the

  • Sola HD S4K2U-5C Series, S4K2U5C SERIES USER MANUAL | 39 8.0 Troubleshooting This section indicates various UPS symptoms a user may encounter and troubleshooting steps in the event the UPS develops a problem. Use the following information to determine whether external factors caused the problem and how to remedy the situation. 8.1 UPS Symptoms The following symptoms indicate the S4K2U-5C is malfunctioning: • The relative indicators will illuminate, indicating the UPS detected a problem • An alarm will sound, indicating that the UPS requires attention 8.1.1 Indicators In addition to the fault indicator being illuminated, one or more of LED

  • 12 | 1.0 Product Description 1.4 Major Components The operating principle of the UPS is illustrated in Figure 3. L1 Dynamic Bypass Input Dc-to-Dc Converter Rectifier / PFC Inverter Battery Battery Charger L1 SPD & EMI/ RFI Filters L2/N Output L2/N GG Figure 3: Operating principle diagram The UPS is composed of mains input, SPD and EMI/RFI lters, rec

  • Sola HD S4K2U-5C Series, 10 | 1.0 Product Description 1.3 Appearance & Components 1.3.1 Front Panel & Controls The SolaHD S4K2U-5C rack/tower models, in various power ratings, have the same general appearance, controls, and features (see Figure 1). The various rack/tower models dier largely in the receptacle type. Operation and Display Panel Ventilation Slots Figure 1: S4K2U-5C rack/tower models—front view 1.3.2 Rear Panel Features The rear panel of the S4K2U-5C has these features (see Figure 2): • USB port • Cooling fan • Input receptacle • Output receptacles • Input circuit breaker • Int

  • Sola HD S4K2U-5C Series, S4K2U5C SERIES USER MANUAL | iii Contents Important Safety Precautions 6 Save these Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Battery Safety Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Electromagnetic Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • S4K2U5C SERIES USER MANUAL | 17 b. Using the nger grips on the display panel, gently pull and rotate 90 degrees clockwise and snap it back into posi- tion as shown in Figure 6. Operation and Display Panel Rotated Clockwise 90 Degrees Figure 6: Rotate the operation and display panel c. Replace the front metal bezel cover on the S4K2U-5C. At this point, the UPS operation and

  • Sola HD S4K2U-5C Series, S4K2U5C SERIES USER MANUAL | 7 Battery Safety Notes ! CAUTION Do not dispose of batteries in a re; they may explode. Dispose of used batteries according to local regulations. Do not open or mutilate the batteries. Released electrolyte is toxic and harmful to skin and eyes. If electrolyte comes into contact with the skin, wash the aected area immediately and get medical attention. ! CAUTION A battery can present a risk of electrical shock and high short-circuit current. The following precautions should be observed when working with batteries: • Remove watches, rings, and other metal objects. • Use tools with insulat

  • Sola HD S4K2U-5C Series, S4K2U5C SERIES USER MANUAL | 35 6.0 Battery Cabinet Optional battery cabinets are available for the S4K2U-5C. The battery port and input breaker are on the battery cabinet’s rear panel, as shown in Figure 27. For battery cabinet specications, refer to Table 12. For battery run times, refer to Table 14. Battery Ports Input Breaker Figure 27: Battery cabinet ! WARNING Do not contact the battery ports and ground without wearing protective gloves and clothing and taking other precautions against electrical shock. The battery loop and ac input are not insulated, wh

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Konica Minolta bizhub PRO 951 Product manual konica-minolta/bizhub-pro-951-6N3.pdf 17 Oct 2023 49
2 Patton electronics 1088/K Operation & user’s manual patton-electronics/1088-k-7U6.pdf 11 Mar 2023 17
3 Vidikron Vision 140 Installation & operation manual vidikron/vision-140-6ZT.pdf 23 Nov 2022 116 6.73 Mb
4 Blaupunkt BREMEN MP74 US Operating and installation instructions blaupunkt/bremen-mp74-us-GG9.pdf 20 Sep 2023 150 26.49 Mb
5 Chroma Color Block PSU30 Operation & user’s manual chroma/color-block-psu30-9F2.pdf 03 Dec 2022 11
6 Logitech 970085-0403 - Z 3 2.1-CH PC Multimedia Speaker Sys Setup & installation logitech/970085-0403-z-3-2-1-ch-pc-multimedia-speaker-sys-CB2.pdf 27 Aug 2022 16

Similar Resources:

  • Tripp Lite

    PDUV30-36

    (16 pages)
    1Metered Rack PDUModels: PDUMV30, PDUMV30HV, PDUV30HV, PDUV30-36, PDUMV20HV, PDUMV20HVL6, PDUMV20HV-36, PDUV20HVL6-72(Series Numbers: AGIB6672, AGPD6673, AGPD6674)Important Safety Instructions 2Important Warnings 2Installation 3Features 3Warranty & Product Registration 4Español 5Français 9Русский 13Owner’s Manual1111 W. 35th Street, Chica …
  • Eaton

    multimatic HotSwap MBP3KI

    (6 pages)
    HotSwap MBP3KI HotSwap MBP 6 IEC Informationen und Angebote auch auf www.edelstrom.eu …
  • CyberPower

    CPS1500AVR

    (2 pages)
    CPS1500AVR User’s Manual K01-0000502-00 (SAVE THESE INSTRUCTIONS) This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unp …
  • INFOSEC

    XP PRO UPS 1000 VA

    (58 pages)
    User guide __________________________ 2 Instrukcja obsługi ____________________ 9 Notice d’utilisation___________________ 16 Guía de usuario _____________________ 23 Εγχειρίδιο χρήσης ___________________ 30 Manual do Utilizador_________________ 37 Руководство пользователя __________ 45 م� …
  • Sentinel

    SNT-1000

    (46 pages)
    Copyright ©POWERCOM CO., Ltd11000 ВА ~ 3000 ВА ИБПИсточник бесперебойного питанияМногофункциональный ON LINE ИБПcерии “SENTINEL”SNT-1000 / SNT-1500 / SNT-2000 / SNT-3000SNT-1000-L / SNT-1500-L / SNT-2000-L / SNT-3000-L■РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ■Revision 1.3 revised A …
  • Toshiba

    G9000 SERIES

    (103 pages)
    UNINTERRUPTIBLE POWER SYSTEM (UPS) G9000 SERIES INSTALLATION AND OPERATION MANUAL 480/480 V 100/160/225/300/500/750 kVA Document: 61480-012 Ref: 4GBA0012 Rev. E August 2014 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Comments, Questions and Opinions: