  • Ampac LoopSense, Page 7 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 5.1.3 PCB Removal / Replacement If the PCB’s have to be removed the following precautions should be observed;  Removing the door will provide better access to the boards and ensure the hinges are not accidentally stressed.  Personal anti- static procedures must be followed.  When disconnecting the 20 way connecting cable from the PCB, make sure that the cable remains connected to at least one board to prevent it being misplaced. Note: Care should be taken when detaching this connector as it is necessary to depress

  • Page 26 LOOPSENSE EN54 INSTALLATION & COMMISSIONING U4 CN4 CN5 CN2 CN1 CN5 CH4 RL8 RL7 RL6 RL5 RL4 RL3 RL2 RL1 ZD2 ZD1 X1 U5 U3 U2 U1 TB8 TB7 TB6 TB5 TB9 TB4 TB3 TB2 TB1 RN3 RN2 RN1 R5 R4 R2 R1 Q4 L2 L1 LK1 HY1 D3 D1 C14 C12 C11 C10 C9 C8 C7 C6 C5 C4 C2 C1 U6 M4 M2 C3 C13 SW1 C15 C16 C17 D2 M1 M5 M6 M7 M8 M9 M10 M11 M12 M13 M14 M15 M16 M17 M18 M19 R3 R6 TB

  • Ampac LoopSense, Page 10 LOOPSENSE EN54 INSTALLATION & COMMISSIONING The batteries should be connected in series using the series link wire provided and located within the panel enclosure. The red and black battery leads from the Power Supply (TB2) should be run to the batteries in such a way that there is no risk of them being damaged, and then connect the red wire to the positive terminal and the black wire to the negative terminal. The panel's sophisticated battery monitoring protects the batteries against deep discharge by activating a cut off circuit when the stand-by supply voltage reaches approx 21 volts. If batteries are n

  • Ampac LoopSense, Page 50 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 0832 AMPAC Technologies Ltd 7 Ledgar Road Balcatta, Western Australia, 6021 09 0832-CPD-1288 EN54-2 & 4 1997 including amendments 1 & 2 Control and Indicating equipment and Power Supply equipment for fire detection and fire alarm systems for buildings 8281-0105 1 Loop 32 Zone analogue addressable control and indicating equipment 8281-0205 1 Loop 32 Zone analogue addressable control and indicating equipment Provided options:

  • Ampac LoopSense, Page 29 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 10.5 Eight Zone Conventional Board This board has 8 conventional zones. Up to 32 zones max may be configured. The zones may be used in panel programming and cause and effects. The end of line type used for the board is configurable to be any one of the following:  10uF bipolar capacitor (EN54 default)  4k7 resistor  6k8 resistor  10k resistor 12/02/09 BRD43EZC2- JTAG POWER 27V 27V 0V 0V EOL R3 C8 C5 C2 C23 C46 C21 C20 C10 C27 C29 C24 C32 C34 C35 C37 C11 C12 C7 C1

  • Ampac LoopSense, Page 46 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 13. Certification Information The LoopSense is designed and manufactured by: AMPAC TECHNOLOGIES PTY LTD 7 Ledgar Rd Balcatta WA 6021 Western Australia PH: 61-8-9242 3333 FAX: 61-8-9242 3334 Manufactured to: Certificate of Compliance Number: Equipment Serial Number: Date of Manufacture: HEAD OFFICE

  • Ampac LoopSense, Page 37 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 10.7 Printer Specifications  Printing method: directed impact dot matrix  Interface: 8 bit parallel interface  Printing mechanism: 4/6 pin shuttle  Interface port: 26 PIN flat plug 10.7.1 Indicators and Buttons The front panel has an LED indicator and two buttons SEL (SELECT), LF (LINE FEED). SEL Button LF Button TP INDICATOR Paper Paper Cutter Instructions Indicator SEL LF Cassette Ribbon Press and turn to tighten ribbon Press to Release Mechanism PUSH to lock

  • Page 6 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 5. Mechanical The basic LoopSense FACP consists of:  Main PCB  Front Panel control and indicator board  3Amp switch-mode power supply for the metal version 2Amps for the ABS version;  2 X 12 Volt batteries connected in series.  Access keys  Loop activation key for 2 Loop version. 5.1 Mo

  • Ampac LoopSense, Page 11 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 7. Front Panel Control Card The Front Panel Control Card interfaces to the Main Control Board by way of CN5, and supports;  all the controls and functional indicators  the FACP Reset  the Configuration (CONFIG) control  Serial or Parallel Printer port Figure 6: Front Panel Layout 7.1 Levels of Access The FACP supports three levels of access. Access Level 1 (Untrained User): The FACP is in Access Level 1 by default. Only the OVERRIDE, PREVIOUS, NEXT

  • Ampac LoopSense, 9.3.1 Supervised Digital Inputs .............................................................................. 21 9.4 Fire Detector Analogue Loop Interface TB2 .............................................................. 21 9.4.1 Detector loop Isolator Installation .................................................................. 21 9.5 Outputs .................................................................................................................... 23 9.5.1 Supervised Outputs TB3............................................................................... 23 9.5.2 R

  • Ampac LoopSense, Page 45 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 12.2 Trouble Shooting LoopSense  Resolution of all suspected faults MUST only be carried out by suitably qualified technical operatives. Problem Solution No Mains Power Check mains Fuse Power LED flashing Check output voltage it should be set to 27.2V. Low = (less than 26.5V ) High = (greater than 28V ) Check the battery has been connected properly Earth Fault LED illuminated Check all input and out

  • Ampac LoopSense, Page 39 LOOPSENSE EN54 INSTALLATION & COMMISSIONING Hinges LED Push Buttons Paper PUSH Mechanism Release Button Note: Front Door Removed Ink Ribbon Cassette Note: Front Door Removed Replacement Paper Roll Figure 27: Head Mechanism Rotation and Paper Roll Removal / Insertion Take out the empty paper roll and roller Put the new paper roll onto the paper roller and replace as shown above. Connect to the power supply. Press the SEL button to take the printer Off Line, (LED is off). Press the LF button, (paper feed). Feed the edge of the paper into

  • Ampac LoopSense, Page 23 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 9.5 Outputs 9.5.1 Supervised Outputs TB3 Four supervised output are provided on the Main Board. These supervised switched outputs supply a nominal 24VDC, at up to 750mA. Outputs are independently controlled and supervised. Supervision of the outputs for short, open and earth faults applies in both the ON and OFF state. The supervised outputs use a 10K resistor as an end-of-line device. Line conditions are supervised as outlined below. Depen

  • Ampac LoopSense, Page 40 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 10.7.3 Printer Connections and Jumper Link Settings Mounted on the back of the printer mechanism is the PCB that carries the;  Connectors for interconnection to the BRD82ZICC,  Jumper links required to set the programmed print modes; and  Printer 5 volt DC Power Supply. R5 R6 C14 R7 C15 C16 C18 C8 C17 C7 C19 C21 D2 R9 T1 R8 C3 C20 C4 C22 R11 J7 J6 R10 C5 T2 C13 C12 X1 J1 J3 R1 C9 R2 D1 R4 R3 C1 C2 U1 U2 U3 U

  • Ampac LoopSense, Page 3 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 3. Overview & Key Features LoopSense is a 1 - 2 loop Intelligent Analogue / Addressable FACP capable of supporting the following modules:  Apollo protocol - 126 detectors / devices per loop  SmartTerminal  8 Way Relay  8 Way Sounder  32 Indicator  Switch & Indicator  8 Zone Conventional  2nd. Loop enablement by way of a “Loop Activation Key” and programming  Printer  Networking (futu

  • Ampac LoopSense, Page 2 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 2. Introduction 2.1 System Overview The purpose of the LoopSense Fire Alarm Control Panel (FACP) is to monitor changes in inputs, report those changes and update selected outputs as programmed. The FACP processes changes in inputs such as fire, fault, pre-alarm, emergency, security, user, transparent and system and has a built-in menu structure to view its status, perform operational tests, and modify the panel’s configu

  • Responding to a Fire Access Level 1 Indicators Controls   The OVERRIDE key is pressed to override any delays to outputs Activating the “SILENCE ALARMS. BRIGADE USE ONLY” Key will silence all Alarm Outputs. Access Level 2  The EVACUATE key is pressed to turn ON all alarm devices.  The SILENCE/RESOUND key is pressed to silence any

  • Ampac LoopSense, Page 28 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 10.3 32 Zone Indicator Card This card has 32 bi-coloured LED’s which can be used to display the status of up to 32 Zones. The zone numbers assigned to each LED are configurable and the LED’s will operate in the following manner for the respective zone statuses: ZONE STATUS LED STATE LED COLOUR FIRE ON STEADY RED DISABLED ON STEADY YELLOW FAULT FLASH YELLOW ALL OTHER OFF n/a The card will also respond to a lamp test when instigated on the panel to which it is connected. Figure 15: 32 Zone Indicator Decal 10.4 8 Way Switch and

  • Ampac LoopSense, Page 9 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 6.1.4 Earth & Earth Fault If a resistance of <50Ω exists between 0V and the building earth a fault indication will be indicated. Resistance to Earth Status < 50Ω Earth Fault 50 ≤ to ≤ 500 KΩ Indeterminate > 500 KΩ Normal 6.2 Battery Charger The battery charger is an integral part of the Power Supply and is capable of  Recharging standard sized system batteries within 24 hours  Detecting a missing, damaged or undercharged battery  Protecting the battery against reverse or a short circuit condition  Charging batterie

  • Ampac LoopSense, Page 43 LOOPSENSE EN54 INSTALLATION & COMMISSIONING PRIMARY POWER SOURCE CALCULATIONS Battery Charger Current Requirement: Battery is charged for 24 hrs to provide 5Iq + 0.5Ia = ( 5x Iq ) + ( 0.5 x Ia ) = ( 5x Iq ) + ( 0.5 x Ia ) = = ( 5 x 157 ) + ( 0.5 x 537 ) = = 785 + 269 Ah Requirement = Ah = 1.054Ah Battery Charging Current Required = Ah above = 1.054 Where e is the battery efficiency, 0.8 24 x e

  • Ampac LoopSense, Page 22 LOOPSENSE EN54 INSTALLATION & COMMISSIONING Note: Isolating base is polarity sensitive. XP95 Loop Output XP95 Loop Input - + + - + - Figure 10: Terminal Block Connections ISOLATING BASE STANDARD BASE + - IN OUT IN / OUT L1 L2 Loop Terminal L1 L2 + - IN OUT IN / OUT L1 L2 L1 L2 STANDARD BASE - + + - - + + - Figure 11: Typical Loop Arrangement The number of isolating devices on the loop can limit the maximum loop cable length depending on the type of cab

  • Ampac LoopSense, Page 8 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 6. Electrical 6.1 Primary Power Supply The LoopSense Power Supply PCB combines the functions of; A Mains to D.C. switched mode power supply unit that operates from a supply of; 204 - 264VAC @ 47 – 63Hz supplying the system while all zones are in alarm A battery charging and monitoring unit A mains fail is detected when the PSU voltage drops below 24V. 6.1.1 Mains wiring The requirement for the mains supply to the FACP is fixed wiring, using three core cable (no less than 0.75mm a

  • Ampac LoopSense, Page 34 LOOPSENSE EN54 INSTALLATION & COMMISSIONING Editing Figure 23: Editing Screen The SmartTerminal Add-On editing dialog box consists of two types of fields: 1. Non-editable (informational) fields:  Panel – The panel number this module belongs to,  Address – The hardware address of this particular module; addresses can be in the range of 1 to 30,  Reference – The reference number of this module 2. Editable fields:  Multicast Type – The user can select one or more Multicast Types for this module to process,  External – If this checkbox is checked then this Add-On module is to be used on the external module bus,

  • Page 42 LOOPSENSE EN54 INSTALLATION & COMMISSIONING POWER SUPPLY & BATTERY CALCULATOR Criteria Example Panel Configuration Iq Calculation Iq Calculation No Off X mA = Iq No Off X mA = Iq Basic 1 Loop Panel 115 1 115 115 Basic 2 Loop Panel 135 Inter

  • Page 13 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 7.2 System Controls & Indicators The front panel has fourteen push button controls, a key switch and an alpha numeric keypad. Controls, Normal – Enabled (Key Switch) CONTROLS ENABLE KEY SWITCH. = OFF, = ON If the key switch is in the OFF position (access level 1), then the OVERRIDE, PREVIOUS, NEXT, SILENCE

  • Ampac LoopSense, Page 20 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 9. Wiring to the Main Card 9.1 Introduction The system is microcontroller based, with the main processor situated on the Main Board. A secondary microcontroller is used on the front panel card to control the user interface functions such as the display and keyboard. System program and configuration memory is “flash” EEPROM in design. Common interfaces are built onto the main board while other interfaces are provided via Add-On boards. 9

  • Page 1 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 1. About This Manual 1.1 Introduction This manual contains all the information required to install, commission and operate the LoopSense series Fire Alarm Control Panel (FACP) and is only available to and for the use of personnel engaged in its installation, commissioning and

  • Ampac LoopSense, TABLE OF CONTENTS Page No. 1. About This Manual ............................................................................................................... 1 1.1 Introduction ................................................................................................................ 1 1.2 General Requirements ............................................................................................... 1 1.3 References................................................................................................................. 1 1.4 Symbols ..........................................................................

  • Ampac LoopSense, Page 47 LOOPSENSE EN54 INSTALLATION & COMMISSIONING 14. Compatible Devices AMPAC Type Code Auto Learn Default Device Type Displayed Type (19 chars) Type Desc Optical 05h  XP95 Optical XP95 PHOTO PHOTO 05h XP95 Optical with base sounder XP95 PHOTO + SNDR PHOTO 05h XPander Optical XPANDER PHOTO PHOTO 05h S90 Optical S90 PHOTO PHOTO 05h Xplorer Optical XPLORER PHOTO PHOTO 05h Xplorer Optical with base sounder XPLR

Related Products and Documents (Fire Alarms):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Icom IC-24ET Instruction manual icom/ic-24et-TY5.pdf 08 Jun 2023 44
2 Minox DTC 600 User manual manual minox/dtc-600-9QW.pdf 28 Sep 2023 20
3 Frigidaire FRS23KF6D Factory parts catalog frigidaire/frs23kf6d-83F.pdf 08 Mar 2024 23
4 Kenwood KDC-W3544W Instruction manual kenwood/kdc-w3544w-W97.pdf 19 Aug 2022 20
5 Fluke 707 Instruction sheet fluke/707-2FY.pdf 04 Jun 2023 16 0.48 Mb
6 AEG Electrolux EB SL7 Operation & user’s manual aeg-electrolux/eb-sl7-JK5.pdf 27 Oct 2023 24 3.08 Mb

Similar Resources:

  • Advanced

    MxPro4 Series

    (72 pages)
    Installation & Commissioning The operation and functions described in this manual are available from Software Version Mx4200V-023 and Mx4400V-023 onwards. www.acornfiresecurity.comwww.acornfiresecurity.com …
  • E2S

    BExCP3-BG

    (3 pages)
    European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH [email protected] Tel: +44 (0)208 743 8880 Document D150-00-055-IS Issue 1 26-08-20 Sheet 1 of 3 www.e2s.com Fax +44 (0)208 740 4200 BExCP3C-BG Manual Call Point – Break Glass With Resistor Modules For use in Flammable Gas and Combustible Dust …
  • System Sensor

    22051TLE-RF-26

    (10 pages)
    D200-300-00 I56-3890-003Pittway Tecnologica S.r.l. Via Caboto 19/3, 34147 TRIESTE, Italy72 mm32 mm104 mmDESCRIPTIONThe 22051TLE-RF radio sensor is a battery operated RF device designed for use with the M200G-RF radio gateway. It contains a wireless transceiver and runs on an addressable re system (using a compatible proprietary communication pro …
  • Siemens

    FC2005

    (3 pages)
    FC2005/FC901 Enclosure installation instructionDocument ID: A5Q00039693AInstallation instruction without Trim kit18 1/8”5 7/64”16 ½”8 1/4”Mount Control Unit ata convenient height for access to display and controlsCerberusTMPage 1/2 06.2011Fire Safety & Security ProductsBuilding TechnologiesFC2005/FC901 Enclosure installation instructionfirealarm …
  • ICAS

    300-RE

    (2 pages)
    Data Sheet: OPTICAL SMOKE ALARM Model No. 300 - RE Detection part Socket Description The ICAS Model 300-RE is an external powered smoke alarm operating on the scattered light principle with relay output. It is intended for household or similar residential applications as system detector in combine with suitable central unit. …
  • FireClass

    FC430SB

    (4 pages)
    ITALIANOSPECIFICHE TECNICHEVa lo re Iden ti fi ca ti vo: 130Com pa ti bi li tà: usa re solo con Cen tra li se rie FCCa rat te ri sti che am bien ta li: Solo per ap pli ca zio ni in ter neTem pe ra tu ra di fun zio na men to: da -25 a +70 oCTem pe ra tu ra di stoc cag gio: da -40 a +80 oCUmi di tà re la ti va: fino a 95% (sen za con den sa)Di men s …

Comments, Questions and Opinions: