  • The use of unauthorized parts in the repair of the equipment or tam- pering by unqualified personnel will result in dangerous conditions which may cause severe personal injury or equipment damage. Follow all safety instructions contained herein. IMPORTANT The information contained herein is general in nature and not intended for specific application purposes. It does not relieve the

  • Siemens ISOLATED MULTI-DROP SG-6048-01, Contents Siemens Energy & Automation, Inc. 1 Introduction..................................1 1.1 Product Summary......................................1 1.2 How to Use This Manual ...........................1 2 Setting Up the Converter.............2 2.1 Overview....................................................2 2.2 RS-485 Communications Ports.................2 2.3 RS-232 Communications Port ..................2 2.4 Power Module ...........................................2 2.5 Configuration Switches .............................2 2.5.1 TX CONTROL Switches......................2 2.5.2 Operating in Manual Mode .................3 2.5.3 Operating in Automati

  • Siemens ISOLATED MULTI-DROP SG-6048-01, 1 Introduction Siemens Energy & Automation, Inc. 1 1 Introduction 1.1 Product Summary The Siemens Isolated Multi-Drop TM converter is an electronic device that lets you connect your DOS-based PC to the Siemens SEAbus TM communications network for ACCESS TM devices on your power distribution system. (You can also use the converter to connect other RS-485 devices, such as Multilin 169+ and 269+ relays, to your PC.) The Isolated Multi-Drop converts the RS-232 signal from your PC to an RS-485 sig

  • 2 Setting Up the Converter 2 Siemens Energy & Automation, Inc. 2 Setting Up the Converter 2.1 Overview Before connecting the converter to your system, understand the connectors, LEDs and switches. This section describes each of the following features according to their functions: • four RS-485 communications ports • one RS-232 communications port • power module •

  • Siemens ISOLATED MULTI-DROP SG-6048-01, 2 Setting Up the Converter Siemens Energy & Automation, Inc. 3 . Figure 2.4 Rear Panel The BAUD thumbwheel switch selects the data rate for communications. Set the data rate to be consistent with the data rate for your system’s SEAbus communications network. Table 2.1 Tx Control Baud Settings Dial Number Data Rate (bps) 1 1200 2 2400 3 4800 4> 9600 2.5.2 Operating in Manual Mode Set the converter to manual mode since most Siemens application software uses RTS to enable the Isolated Multi- Drop converter’s transmitter. (If your software do

  • Siemens ISOLATED MULTI-DROP SG-6048-01, 3 Installing the Converter 4 Siemens Energy & Automation, Inc. 3 Installing the Converter 3.1 Getting Ready This section explains how to install the Isolated Multi-Drop converter for your operation. You can install the converter either directly to a PC or remotely within switchgear using short-haul or dial-up modems. This section also tells you how to connect Static Trip III trip units and SAMMS devices to the converter’s power module, enabling you to test these devices in the field. Before attempting to install the converter, check to see that you have the following parts in addition to the converter: • a power cord • a two

  • Siemens ISOLATED MULTI-DROP SG-6048-01, 3 Installing the Converter Siemens Energy & Automation, Inc. 5 3.3 Connecting Directly to a PC To connect the Isolated Multi-Drop converter directly to a PC, you need an RS-232 serial cable of not more than 50 feet in length. Make sure the cable is a DCE-DTE cable, not a null modem cable. The following table lists the minimum set of required signals and the pin assignments for DB-25 to DB-25 and DB-9 to DB-25 cable connectors: To connect the converter to a PC, follow these steps while refering to Figu

  • Siemens ISOLATED MULTI-DROP SG-6048-01, 3 Installing the Converter 6 Siemens Energy & Automation, Inc. 3.4 Connecting with Short-Haul Modems If the distance between your PC and Isolated Multi-Drop converter is greater than 50 feet but less than 3.5 miles, you can connect them using short-haul modems and regular telephone cable. To install the Isolated Multi-Drop converter using short-haul modems, you need these items: • two short-haul modems • telephone cable that does not exceed 3.5 miles in length • one Isolated Multi-Drop converter mounting kit (if you want to moun

  • Siemens ISOLATED MULTI-DROP SG-6048-01, 3 Installing the Converter Siemens Energy & Automation, Inc. 7 3.5 Connecting with Dial-Up Modems If the distance between your PC and Isolated Multi-Drop converter is greater than 3.5 miles, you can connect them using dial-up modems. To install the Isolated Multi-Drop converter using dial-up modems, you need these items: • two dial-up modems • one RS-232 serial cable no more than 50 feet in length (unless your PC’s modem is directly installed in the computer) • one null modem cable no more than 50 feet in length • a telephone line for each m

  • Siemens ISOLATED MULTI-DROP SG-6048-01, 4 Testing ACCESS Devices 8 Siemens Energy & Automation, Inc. 4 Testing ACCESS Devices You can use the Isolated Multi-Drop converter’s 15 VDC power output to provide DC power for testing Static Trip III trip units or SAMMS devices. According to the steps in this section, first prepare a cable for connecting the devices to the converter. Then follow the appropriate procedure for the specific device(s) you want to connect to the converter. 4.1 Prepare Cable To prepare the cable, follow these steps while referring to Figure 4.1. 1. Select a two-conductor cable of sufficient

  • 4 Testing ACCESS Devices Siemens Energy & Automation, Inc. 9 4.3 Testing Static Trip III on Desktop If you are testing a Static Trip III trip unit on a desktop, follow these steps to connect the trip unit to the converter for 15 VDC power, while referring to Figure 4.3: 1. Plug the connector of the two-conductor cable into the 15 VDC output port. 2. Making sure to

  • Siemens ISOLATED MULTI-DROP SG-6048-01, 4 Testing ACCESS Devices 10 Siemens Energy & Automation, Inc. Figure 4.4 Connecting SAMMS Device for Testing Two-wire cable RS-485 cable rear panel front panel 15VDC OUT + - RS485 + _ + _ RS485 RS485 RS485 RS485 + _ + _ + _ Isolated Multi-Drop 12 3 4 SAMMS device Ribbon cable 1 23456 7 8910 11 12 13 14 15 16 CM-1 Two-wire cable Pins 5 and 6

  • Siemens ISOLATED MULTI-DROP SG-6048-01, 5 Troubleshooting Siemens Energy & Automation, Inc. 11 5 Troubleshooting If you experience communications errors and suspect the Isolated Multi-Drop converter is at fault, perform the actions listed below. Before performing these tests: 1. Verify that your application software is properly set up. 2. Verify that the cables between the components are connected correctly according to the installation instructions. If transmission through the Isolated Multi-Drop converter fails (one or more of the Tx LEDs fails to blink), perform the following checks in the order given: 1. If some (but not all four) of the Tx LEDs blink simultaneously, the Isolated Multi-Drop c

  • Siemens ISOLATED MULTI-DROP SG-6048-01, Appendices Siemens Energy & Automation, Inc. 13 Appendix A: Block Diagram The illustration below is a block diagram showing how the Isolated Multi-Drop converter operates. The diagram identifies the internal components that make up the converter. Figure A.1. Block Diagram 25-pin D Connector RXD TXD RTS DCD Signal Ground RS-232 Transceiver 3 2 4 8 7 Galvanically Isolated RS-485 Logic Tx Enable + - SHIELD RS-485 Port 1 Tx Enable + - SHIELD RS-485 Port 2 Tx Enable + - SHIELD RS-485 Port 3 Tx Enable + - RS-485 Port 4 Earth Ground Baud Switch Tx Enable Logic RTS/DCD AUTO/MAN RTS DCD MAN AUTO RS-232 Connec

  • Appendices Siemens Energy & Automation, Inc. 15 Appendix B: Mounting Dimensions The illustration below shows the mounting dimensions for the Isolated Multi-Drop converter. Use these dimensions to muont the converter to a switchgear panel or to some other location. For more information on installation, refer to section 3, Installing the Converter. Figure B.1. Mounting

  • Siemens ISOLATED MULTI-DROP SG-6048-01, Siemens Energy & Automation, Inc. Switchgear and Motor Control Business P.O. Box 29503 Raleigh, NC 27626-0503 Manual No. SG-6048-01 (Replaces -00) 1M 0595FP Printed in U.S.A. © 1992-1995 Siemens Energy & Automation, Inc. SIEMENS is a registered trademark of Siemens AG

Related Products and Documents (Media Converter):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Whirlpool LER4624DQ0 Parts list whirlpool/ler4624dq0-3D9.pdf 22 Mar 2024 5 0.41 Mb
2 Savin 3232 Operating instructions manual savin/3232-X55.pdf 28 Jun 2022 228 6.23 Mb
3 Zanussi ZGG649 Operation & user’s manual zanussi/zgg649-SN1.pdf 29 Oct 2023 12 0.72 Mb
4 Oregon Scientific RM303P Operation & user’s manual oregon-scientific/rm303p-Y78.pdf 10 Jan 2024 2
5 Rose electronics ViewLink Coax Features and benefits rose-electronics/viewlink-coax-1K1.pdf 05 Aug 2023 2 0.09 Mb
6 Tview T712HR-IR Owner's manual tview/t712hr-ir-36D.pdf 21 Jun 2023 4 0.67 Mb

Similar Resources:

  • Wyrestorm

    NetworkHD 400 series

    (4 pages)
    IMPORTANT! Installation Requirements• Visit the NetworkHD product pages download section at wyrestorm.com to check for the latest rmware, document versions, and WyreStorm Management Suite conguration tools.• Install the latest rmware onto all encoders and decoders using the Maintenance Tool found in the Management Suite and via the NHD-000-C …
  • McIntosh

    MB50

    (24 pages)
    McIntosh Laboratory, Inc. 2 Chambers Street Binghamton, New York 13903-2699 Phone: 607-723-3512 www.mcintoshlabs.comMB50Streaming Audio PlayerOwner’s Manual …
  • MRC

    0001636

    (2 pages)
    N Gauge SynchronizedDiesel Sound Decoder with19 Accessory Sound FunctionsItem #0001636Thank you for purchasing our highly advanced DCC locomotivesound decoder. Combined with any DCC System, our newdecoder with authentic diesel sound truly will make your modelrailroad come to life.• Synchronized diesel prime mover with randomlyassociated locomotive sounds� …
  • Miranda

    FIO-1901-RR

    (27 pages)
    DENSITÉ series FIO-1901-RR 3G/HD/SD Fiber Optic to Electrical Converter Guide to Installation and Operation M927-0100-100 14 Apr 2011 Miranda Technologies Inc. 3499 Douglas-B.-Floreani St-Laurent, Québec, Canada H4S 2C6 Tel. 514-333-1772 Fax. 514-333-9828 www.miranda.com © 2011 Miranda Technol …
  • ResMed

    H5i

    (60 pages)
    1S9 AutoSet™ / S9 AutoSet™ for Her / S9 Elite™ / S9 Escape™ / S9 Escape Auto™POSITIVE AIRWAY PRESSURE DEVICESH5i™ / H5i™ for Her HEATED HUMIDIFIERClimateLine™ / ClimateLineMAX™ / SlimLine™ / StandardAIR TUBINGInformation GuideEnglish • Français • Español • PortuguêsS9 AutoSet indications for useThe S9 AutoSet self-adjusting syste …
  • Sony

    NAS-CZ1 M-Crew

    (53 pages)
    System RequirementsThe following software and hardware are required in order to be able to run M-crew Server. A PC/AT compatible that satisfies the performance requirements described below. M-crew Server does not run in an Apple Macintosh environment. CPU*: Intel Pentium III 600 MHz (1 GHz or more is recommended) or Celeron 600 MHz (1 GHz or more is re …

Comments, Questions and Opinions: