Text of Bard Q24A2 User Guide:

  • Manual 2100-600 Page 2 of 38 CONTENTS Figures Figure 1 Unit Dimensions ........................................... 7 Figure 2 Air Seal Under Unit ...................................... 8 Figure 3 Removal of Unit From Skid .......................... 8 Figure 4 Unit on Appliance Cart for Moving................ 9 Figure 5 Installation With Free Blow Plenum ........... 10 Figure 6

  • Bard Q24A2, Manual 2100-600 Page 4 of 38 Q-Tec Series General Information Q-Tec MODEL NOMENCLATURE INTERNAL CONTROLS X - Standard • High Pressure Switch • Low Pressure Switch • Compressor Control Module w/Time Delay J - Alarm Relay + LAC + Above FILTER OPTIONS X - 1 inch Fiberglass (Standard) F - 2 inch Fiberglass P - 2 inch Pleated Q 42 A 2 A 10 X X V X X X CAPACITY 24 - 2 Ton 30 - 2½ Ton 36 - 3 Ton 42 - 3½ Ton 48 - 4 Ton 60 - 5 Ton KW 0Z - 0KW 05 - 5KW 06 - 6KW 09 - 9KW 10 -10KW 12 -12KW 15 -15KW COIL OPTIONS X - Standard 1 - Phenolic coated

  • Bard Q24A2, Manual 2100-600 Page 30 of 38 6. Some service requires the need to remove the unit from the wall including replacement of the indoor coil and/or the outdoor coil. Also servicing the outdoor fan motor or fan blade will require removing the unit from the wall if the unit is installed at a height that is not easily accessible from the outside of the building. In order to remove the unit from the wall the following procedure must be used: a. Turn off power to the unit at the remote location. Some units may have more than one power supply. b. Disconnect eld wiring at unit terminal block and remove from unit. c. Discon

  • Bard Q24A2, Manual 2100-600 Page 18 of 38 Washer Sleeve Stud MIS-2689 Nut Lower Control Panel Condenser Door (Removed) Return Grille FIGURE 13A UNIT MOUNTING BOTTOM TRIM PIECE BOTTOM TRIM EXTENSION MOUNTING BRACKET SIDE TRIM (2PCS.) SIDE TRIM (2PCS.) CABINET SIDE PANEL ENLARGED VIEW OF MOUNTING BRACKET SHOWING SLEEVE TO CABINET ATTACHMENT MOUNTING BRACKET #8 SCREW PROVIDED (LIGHT COLOR) WALL SLEEVE #10 HEX HEAD SCREW PROVIDED FIGURE 13B UNIT MOUNTING

  • Bard Q24A2, Manual 2100-600 Page 31 of 38 3. Underneath the heat recovery cassette there is a power connector for the lower blower assembly. To disconnect this plug, the tabs on both sides of the plug must be squeezed to release the plug. While squeezing the tabs, pull the plug out of the socket. 4. The QERV is plugged into the unit in the right side of the unit. Both of these plugs must be disconnected to remove the QERV. Squeeze the tabs on the sides of the connector and pull straight out. 5. Slide the QERV assembly straight out of the unit, being careful not to l

  • Bard Q24A2, Manual 2100-600 Page 5 of 38 TABLE 1 FACTORY BUILT-IN ELECTRIC HEAT TABLE Models Q24A2-A Q30A2-A Q24A2-B Q30A2-B Q24A2-C Q30A2-C Q36A2-A Q42A2-A Q48A2-A Q36A2-B Q42A2-B Q48A2-B Q36A2-C Q42A2-C Q48A2-C Q60A2-A Q60A2-B Q60A2-C 240V-1 208V-1 240V-1 208V-1 240V-1 208V-1 480V-3 480V-3 240V-1 208V-1 240V-1 208V-1 480V-3 240V-1 208V-1 240V-1 208V-1 480V-3 KW BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH 5.0 16,380 12,290 16,380 12,290 6.0 20,500 15,360 20,500 15,360 20,500 20,500 20,500 15,360 20,500 9.0 30,700 23,000 30,700 23,000 30,700 30,

  • Manual 2100-600 Page 25 of 38 FIGURE 19 UNIT MOUNTED THERMOSTAT WIRING DIAGRAM “D” THERMOSTAT OPTION W1/E 8403-060 "D" THERMOSTAT OPTION Y2 12 Plug #2 Brown G Purple Orange C Blue 9 10 6 5 Black/White A 3 11 8 4102-070 4 R Y1 7 Red/White W2 1 Yellow 2 Brown/White

  • Bard Q24A2, Manual 2100-600 Page 21 of 38 LOW VOLTAGE CONNECTIONS FOR DDC CONTROL Fan Only Energize G Cooling Mode Energize Y1, G 1st Stage Heating Energize G, W1 2nd State Heating Energize G, W2 (if employed) Ventilation Energize G, F GENERAL This unit is equipped with a variable speed ECM motor. The motor is designed to maintain rated airow up to the maximum static allowed. It is important that the blower motor plugs are not plugged in or unplugged while the power is on. Failure to remove power prior to unplugging or plugging in the motor could result

  • Bard Q24A2, Manual 2100-600 Page 20 of 38 WIRING – MAIN POWER Refer to the unit rating plate and/or Table 2 for wire sizing information and maximum fuse or “HACR Type” circuit breaker size. Each unit is marked with a “Minimum Circuit Ampacity”. This means that the eld wiring used must be sized to carry that amount of current. Depending on the installed KW of electric heat, there may be two eld power circuits required. If this is the case, the unit serial plate will so indicate. All models are suitable only for connection with copper wire. Each unit and/or wiring diagram will be

  • Manual 2100-600 Page 8 of 38 SHIPPING DAMAGE Upon receipt of equipment, the carton should be checked for external signs of shipping damage. The skid must remain attached to the unit until the unit is ready for installation. If damage is found, the receiving party must contact the last carrier immediately, preferably in writing, requesting inspection by the carrier’s agent.

  • Bard Q24A2, Manual 2100-600 Page 27 of 38 START UP THESE UNITS REQUIRE R-410A REFRIGERANT AND POLYOL ESTER OIL. GENERAL: 1. Use separate service equipment to avoid cross contamination of oil and refrigerants. 2. Use recovery equipment rated for R-410A refrigerant. 3. Use manifold gauges rated for R-410A (800 psi/250 psi low). 4. R-410A is a binary blend of HFC-32 and HFC-125. 5. R-410A is nearly azeotropic - similar to R-22 and R-12. Although nearly azeotropic, charge with liquid refrigerant. 6. R-410A operates at 40-70% higher pressure than R-22, and systems designed for R-22 cannot withstand this higher pressure. 7. R-410A has an ozone depletion pot

  • Bard Q24A2, Manual 2100-600 Page 37 of 38 FAN BLADE SETTING DIMENSIONS Any service work requiring removal or adjustment in the fan and/or motor area will require that the dimensions in Table 5 be checked and blade adjusted in or out of the motor shaft accordingly. jMaximumESP(inchesWC)showniswith1"thickdisposablelter(reducedby.2for2"lter). Rated CFMforductedapplications–requiredformaximumperformancerating.ToobtainfullCFMonmodelsQ36A2,Q42A2,Q48A2and  Q60A2connectthepinkjumperwire(provided)totermina

  • Bard Q24A2, Manual 2100-600 Page 15 of 38 SUPPLIED WITH DRAIN BOX KIT 3/4" PLASTIC PIPE NIPPLE HORIZONTAL TO FLOOR) (TIGHTEN THREADS SO TEE IS THREADS) (APPLY TEFLON TAPE TO REAR DRAIN CONNECTION IN Q/Tec PRODUCT 1/2" SLIP X 1/2" SLIP X 3/4" NPT TEE SUPPLIED WITH DRAIN BOX KIT PLUG INSTALLED IN SIDE Q/Tec DRAIN MIS-2470 FIGURE 12B IMPORTANT !

  • Bard Q24A2, Manual 2100-600 Page 9 of 38 HANDLING UNIT AFTER REMOVAL FROM SKID The unit will have to be turned sideways and removed from the skid to t through a 36" doorway. If the door height allows, the unit can be slid sideways through the door. If the unit can not be slid through the door, then the unit will have to be put on a cart and tipped down to roll through the door. It is recommended that an appliance cart by used with a strap to hold the unit on the cart. The wheels of the unit must be lock

  • Bard Q24A2, Manual 2100-600 Page 35 of 38 TROUBLESHOOTING GE ECM ™ MOTORS CAUTION: Disconnect power from unit before removing or replacing connectors, or servicing motor. To avoid electric shock from the motor’s capacitors, disconnect power and wait at least 5 minutes before opening motor. Symptom Cause/Procedure Motor rocks slightly • This is normal start-up for ECM when starting Motor won’t start • Check blower turns by hand • No movement • Check power at motor • Check low voltage (24 Vac R to C) at motor

  • Manual 2100-600 Page 17 of 38 MIS-2472 DRAIN HOSE FROM INDOOR DRAIN PAN. MOVE HOSE FROM ATTACHMENT IN LOWER DRAIN PAN AND SLIDE ONTO DRAIN BOX BARB FITTING, SECURING WITH SUPPLIED CLAMP IF OUTDOOR PAN IS BYPASSED. ( WILL REDUCE RISK OF ALGAE GROWTH IN THE OUTDOOR PAN BUT AT A SLIGHT COOLING PERFORMANCE REDUCTION OF 2-3% ) FIGURE 12D

  • Bard Q24A2, Manual 2100-600 Page 26 of 38 FIGURE 20 UNIT MOUNTED THERMOSTAT WIRING DIAGRAM “H” THERMOSTAT OPTION WITH CO 2 3 2 4 51 2 Orange 24 VAC 5 6 HOT 1 Orange 2 Red/White Blue 9 10 6 Part #8403-060 5 Black/White G 3 11 8 R Y1 Plug #2 C W2 1 Yellow 12 Purple Brown 7 A Brown/White 2 Y2 Black/White Red/White Brown/White Out Controller Red/White W1/E 4 3 4 Analog Bard Part #8403-067 Temp. and Humidity CO Controller COM 3 1 "H" THERMOSTAT OPTION Relay Part #8201-062 4 5 2 Black/White 4102-071 A Red/White

  • Bard Q24A2, Manual 2100-600 Page 22 of 38 FIGURE 16 TABLE 4 WALL THERMOSTATS MIS-1285 Thermostat Predominant Features 8403-060 (1120-445) 3 stage Cool; 3 stage Heat Programmable/Non-Programmable Electronic HP or Conventional Auto or Manual changeover 8403-058 (TH5220D1151) 2 stage Cool; 2 stage Heat Electronic Non-Programmable HP or Conventional Auto or Manual changeover 8403-056 (C7232A1008) Carbon Dioxide Sensor with LCD for Sensor Readings

  • Bard Q24A2, Manual 2100-600 Page 12 of 38 FRESH AIR INTAKE This unit is equipped with a fresh air damper assembly. The damper blade is locked in the closed position when the unit is shipped from the factory. To allow the damper to operate remove the two plastic locking pins, one on each end of the blade. This will allow for maximum fresh airow. The damper blade will now open when the indoor blower is operating. If less than maximum fresh airow is required, reinsert the plastic pins to limit damper blade opening to desired level. Two extra pins are provided (taped to the inside of the assembly) which may be used to hol

  • Bard Q24A2, Manual 2100-600 Page 11 of 38 DUCT WORK All duct work must be properly sized for the design airow requirement of the equipment. Air Conditioning Contractors of America (ACCA) is an excellent guide to proper sizing. All duct work or portions thereof not in the conditioned space should be properly insulated in order to both conserve energy and prevent condensation or moisture damage. When duct runs through unheated spaces, it should be insulated with a minimum of one inch of insulation. Use insulation with a v

  • Bard Q24A2, Manual 2100-600 Page 23 of 38 FIGURE 17 REMOTE THERMOSTAT WIRING DIAGRAM “X” THERMOSTAT OPTION NOTE: On option X or A the CS2000A* (or other eld provided means to control ventilation) must be used if any of the motorized ventilation options are installed. 1 Y2 W1 R C W2 Y1 E 1 2 G Y2 A Y1 W2 C R W1/E 1 G Y2 Y W2 C R W 2 3 4 5 6 7 8 9 11 12 10 F Rc G 2 3 BROWN PURPLE RED/WHITE BLUE YELLOW TERMINAL BLOCK8403-060 1 8403-058 BLACK/WHITE BROWN/WHITE MIS-2693 ON 15KW MODELS REMOVE JUMPER FOR 2 STAGE ELECTRIC HEAT OPERATION FACTORY INSTALLED JUMPER TH5220D1151 PLUG 2 LOW VO

  • Bard Q24A2, Manual 2100-600 Page 29 of 38 All three phase scroll compressors used in the Q-Tec series are wired identically internally. As a result, once the correct phasing is determined for a specic system or installation, connecting properly phased power leads to the same Fusite terminal should maintain proper rotation direction. The direction of rotation of the motor may be changed by reversing any two line connections to the unit. COMPRESSOR CONTROL MODULE The compressor control module is standard on all mod

  • Bard Q24A2, Manual 2100-600 Page 24 of 38 FIGURE 18 UNIT MOUNTED THERMOSTAT WIRING DIAGRAM “B” OR “C” THERMOSTAT OPTION NOTE: On option X or A the CS2000A* (or other eld provided means to control ventilation) must be used if any of the motorized ventilation options are installed. W1/E Orange 2 Yellow Brown 7 G 12 W2 Red/White Blue 9 10 1 6 5 Black/White A 3 11 8 4 R Purple Plug #2 C Y1 Brown/White SC SC SC 4102-076 YO "B" OR "C" THERMOSTAT OPTION "B" CSB9E-THO "C" CSB9E-THOC

  • Bard Q24A2, Manual 2100-600 Page 19 of 38 INSTALLATION INSTRUCTIONS MOUNTING THE UNIT When installing a Q-Tec unit near an interior wall on the left side, a minimum of 8 inches is required; 12 inches is preferred. When installing a Q-Tec unit near an interior wall on the right side, a minimum of 18 inches is required as additional space is required to connect the side drain. If the rear condensate drain kit QCDS48 is used the minimum can be reduced to 8 inches. This clearance is required to allow for the attachment of the unit t

  • Bard Q24A2, Manual 2100-600 Page 1 of 38 Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914 . . . Moving ahead, just as planned. Manual: 2100-600 Supersedes: NEW File: Vol II Tab 14 Date: 08-21-13 Models: Q24A2 Q30A2 Q36A2 Q42A2 Q48A2 Q60A2 Q-TEC SERIES PACKAGED AIR CONDITIONER INSTALLATION INSTRUCTIONS

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Dell 2300 Service manual dell/2300-554.pdf 10 May 2023 84 3.06 Mb
2 Marantz PS-17 Service manual marantz/ps-17-375.pdf 15 Mar 2023 52
3 Pharos PDR200 Quick start manual pharos/pdr200-6MY.pdf 05 Jul 2023 1 3.01 Mb
4 Aiphone IBG-1HD Instructions aiphone/ibg-1hd-F97.pdf 08 Feb 2023 4 0.21 Mb
5 Makita 6011D Instruction manual makita/6011d-322.pdf 16 Sep 2023 12
6 AEG X56342SE10 Operation & user’s manual aeg/x56342se10-4S6.pdf 31 Jul 2022 96

Similar Resources:

  • Livoo

    DOM392

    (44 pages)
    DOM392 κινητό τοπικό κλιματιστικό p2-p22 p23-p40 p41-p59 p60-p79 p80-p98 p99-p117 p118-p136 version_2019 GR EN ES DE IT PT NL …
  • Honeywell

    CL30XC

    (18 pages)
    OFFONCOOLOFFONSWEEPOFFHMLPortable Evaporative Air CoolerINSTRUCTION MANUALRead and save these instructions before useModel: CL30XCWith Remotewww.ushainternational.com …
  • Carrier

    4 2 gw

    (153 pages)
    *:,QVWDOODWLRQPDQXDO0DQXDOHGLLQVWDOOD]LRQH0DQXHOG·LQVWDOODWLRQ Installationsanweisung0DQXDOGHLQVWDODFLyQ0RQWDJH,QVWUXFWLHVO K0DQXDOGHLQVWDODomR,QVWDOODWLRQVPDQXDO$VHQQXVRKMH,QVWUXNFMDLQVWDODFMLРУКОВОДСТВО ПО МОН …
  • Scotsman

    UC2024 Series

    (3 pages)
    UC2024 and UC2724 User ManualNovember 2019Page 13Maintenance and CleaningFrequency: Cleaning is recommended about twice a year. The ice machine will not maintain a sanitary condition without human intervention. Prep: Obtain food grade scale remover such as Scotsman Clear 1. You will also need a clean container, sanitizer, clean cloths and clean rubber gloves …
  • McQuay

    Maverick I MPS006AY

    (24 pages)
    Maverick I™Commercial Packaged Rooftop SystemCooling Only or Heating & CoolingElectric/ElectricModel MPS006AY6 TonsInstallation and Maintenance ManualIM 865Group: Applied SystemsPart Number: 92-102421-04-00Date: March 2007© 2007 McQuay International …
  • Sharp

    AE-X4M30PU

    (42 pages)
    AE-X4M30PU1SPECIFICATION --------------------------------------------------------------------------------------------------------------- 2SPECIFICATION ----------------------------------------------------------------------------------------------------------2EXTERNAL DIMENSION ---------------------------------------------------------------------------------- …

Comments, Questions and Opinions: