Manualios.com

Infinion C13 Installation And Operation Manual

Infinion C13 Manual Online:

4.75, 556 votes
Infinion C13 User Manual
Infinion C13 User Guide
Infinion C13 Online Manual

Text of Infinion C13 User Guide:

  • Infinion C13, WARNING FOR YOUR SAFETY • Do not try to light any appliance. • Do not touch any electrical switch or use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. • Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. • Do not return to your building until authorized by the gas supplier or fire department. Do not store or use gasoline or other flammable, combustible or corrosive vapors and liquids in the vicinity of this or any other a

  • Infinion C13, Page 2 Infinion C13 Installation and Operation Manual Gasoline, as well as other flammable materials and liquids (adhesives, solvents, etc.), and the vapors they produce, are extremely dangerous. DO NOT handle, use or store gasoline or other flammable or combustible materials anywhere near a water heater. Read and follow the warning label pictured below and other labels on the water heater, as well as the warnings printed in this manual. Failure to do so can result in property damage, bodily injury, or death. General Safety Precautions Read and understand this entire manual before installing

  • Infinion C13, Page 3Infinion C13 Installation and Operation Manual LIQUEFIED PETROLEUM MODELS - Propane, or LP gas, must be used with great caution. • It is heavier than air and will collect first in lower areas making it hard to detect at nose level. • Check for LP leaks before lighting the heater. Use a soapy solution to check all gas fittings and connections. Bubbling at a connection indicates a leak that must be corrected. When smelling to detect an LP leak, be sure to sniff near the floor too. Gas detectors are recommend

  • Page 4 Infinion C13 Installation and Operation Manual Water heaters utilizing Liquefied Petroleum gas (LP) are different from natural gas models. A natural gas heater will not function safely on LP gas and vice versa. To avoid possible equipment damage, personal injury or fire: DO NOT connect this water heater to a fuel type not in accordance with unit data plate. Use pro

  • Page 5Infinion C13 Installation and Operation Manual Adjust the outlet water temperature of the heater by setting the temperature dial on front of the Infinion. The illustration below shows the approximate water temperature for each position of the temperature dial. There is a Hot Water SCALD Potential if the temperature knob is set too high. Mixing valves for reduci

  • Page 6 Infinion C13 Installation and Operation Manual Read and Review this entire Manual with special emphasis on the Venting Section (Page 12) and Operation Section (Pages 17 - 19) prior to any installation work. General Installation Guidelines • Follow these instructions when you install your heater. In the United States: The installation must conform with local codes or, in the absence of l

  • Infinion C13, Page 7Infinion C13 Installation and Operation Manual Locate Your Heater Carefully select the location of your new heater. For your safety and for proper heater operation, you must provide an abundant supply of combustion air and a proper venting installation. The heater may still operate even if improperly vented. However, it will be less efficient and could eventually become damaged. It could even result in human sickness or death due to oxygen deprivation and carbon monoxide poisoning. Follow the guidelines below: • Install your heater as close to a vent or chimney as possible. • Do not install this appliance in bathrooms, bedrooms, unvented closet or any occupied ro

  • Infinion C13, Page 8 Infinion C13 Installation and Operation Manual General Installation Guidelines Provide Adequate Combusion Air Observe the following instructions concerning combustion air. Appliances located in unconfined spaces: • An unconfined space is one whose volume is greater than 50 cubic feet per 1000 Btu per hour of the combined rating of all appliances installed in the space. That would be 5250 cubic feet for just the Infinion C13. • In unconfined spaces in buildings of conventional frame, masonry, or metal constru

  • Infinion C13, Page 9Infinion C13 Installation and Operation Manual Allow Proper Clearances The Infinion is designed for installation on a combustible wall and for installation in an alcove with the minimum clearances to combustible and non - combustible construction listed below • Top - 12 inches ( 305 mm) • Front - Open for access • Back - 0 inches • Sides - 4 inches (102mm) • Bottom - 12 inches (306 mm) General Installation Guidelines 14 15/16" 10 13/16" 5 3/8" 27 11/16" 28 1/8"

  • Infinion C13, Page 10 Infinion C13 Installation and Operation Manual Installing Your Infinion Unpack the Infinion The Infinion shipping box contains your heater and the accessory parts necessary to properly hook up to the water and gas supplies and to the vent system. Note - • Before removing the Infinion from the box, remove the top board of the wooden box reinforcement. • Do not grasp the sides of the heater casing when lifting the Infinion out of the box. Lift the heater by the foam end pieces. Along with the heater, the box contains the following hookup parts: • 5" flue adapter • Cold water inlet adapter with integral water stop cock • Hot

  • Infinion C13, Page 11Infinion C13 Installation and Operation Manual Mount the Infinion to the Wall • Do not install this appliance on a carpeted wall or above floor covering which is combustible, such as carpet. • Mount the heater on the wall using adequate anchors at the two mounting points (see drawing below). • If the wall is a stud wall sheathed with plasterboard, first install support board(s), either 1x4's or 1/2" (minimum) plywood, across a pair of studs and then mount the heater to the support boards. Expansion and contraction of the piping due to changing water temperature in the pipes imparts movement to the heater. If

  • Infinion C13, Page 12 Infinion C13 Installation and Operation Manual You must vent this heater to the outside following all local ordinances and specifications for installing a gas appliance vent or chimney. Vent the Infinion Installing Your Infinion Do not reduce the vent pipe size WARNING • The venting system must be designed and constructed so as to develop a positive flow adequate to remove flue gasses to the outdoors. • Minimum vent size must be 5". Use the flue adapter included with your heater to connect the draft diverter to 5&qu

  • Infinion C13, Page 13Infinion C13 Installation and Operation Manual Connect the gas supply to the Infinion gas valve using the 1/2" steel ninety degree fitting and washer as illustrated on page 16. Connect the Gas Installing Your Infinion Before connecting the gas supply, check the rating plate on the front of the draft diverter to be sure that the heater is rated for the same gas to which it will be connected. WARNING • In the United States: the installation must conform with local codes or, in the absence of local codes, the National Fuel Gas Code ANSI Z223.1/NFPA 54. In Canada: The Installation should conform with CGA B149INSTALLATION CODES and /or local installation codes.

  • Infinion C13, Page 14 Infinion C13 Installation and Operation Manual Installing Your Infinion Disconnect the heater from the gas supply piping system during any pressure testing of that system at test pressures in excess of 0.5 psig. Isolate the water heater from the gas supply piping system by closing the manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 0.5 psig. Do not operate the water heater, including the pressure regulator provided with it, at gas supply pressures in excess of 0.5 psig

  • Infinion C13, Page 15Infinion C13 Installation and Operation Manual Connect the Water Installing Your Infinion Connect the hot and cold water lines to the Infinion using the accessory fittings as illustrated in the drawing on the next page. • Regardless of the type of water piping in your structure, use copper piping (for at least three feet before and after) to connect to the heater. • Use no less than 1/2 inch diameter pipe to assure full flow capacity. • If the hot and cold connections to the heater are reversed, the heater will not function. • The Infinion C13 has two ½" copper sweat fittings for the inlet and outlet water connections. These fittings seal to the

  • Infinion C13, Page 16 Infinion C13 Installation and Operation Manual W all 2" 1.9" 3.5" 1.5" Cold Inlet 2" Hot Outlet Gas Gas and Water Connections Installing Your Infinion Note -- Use the fiber washers as shown in the illustration. Do not use any pipe dope or teflon tape on those connections.

  • Infinion C13, Page 17Infinion C13 Installation and Operation Manual Start the Infinion Operating Your Infinion Before starting the heater, fill the system with water. • Open the cold water inlet supply to the heater fully. • Open a hot water faucet to let water fill the heater and the piping and to eliminate the air trapped in the system. • Close the hot water faucet after the water flows freely and all the air has escaped from the system. • The water heater is now ready to start. To start the Infinion, follow the instructions on the front cover of the heater.

  • Page 18 Infinion C13 Installation and Operation Manual Set the Water Temperature Operating Your Infinion The Infinion has a gas control that adjusts burner input in response to flow. Its purpose is to ensure that the hot water temperature will remain steady, although the water flow demand might vary. To adjust the temperature on your Infinion, turn on a hot wat

  • Infinion C13, Page 19Infinion C13 Installation and Operation Manual Adjust the Gas Input Capacity The position you select on the temperature adjustment knob will depend on the temperature of the incoming water (50 o F is average in the U.S.). In warm weather regions where the incoming cold water is generally warmer, or during the hot weather months in some other areas a midway setting on the temperature adjustment knob would produce a temperature rise of about 70 o F, giving an output of approximately 120 o F. At this setting, if it is still necessary, one c

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 GTO SW-4000XL Installation manual gto/sw-4000xl-V58.pdf 30 Aug 2022 44 2.97 Mb
2 Edgestore DAS400 Operation & user’s manual edgestore/das400-MG3.pdf 25 Jul 2023 31 2.81 Mb
3 Philips HF3471/01 Operation & user’s manual philips/hf3471-01-681.pdf 15 Nov 2022 120 1.93 Mb
4 Conair WW31 Instructions for use conair/ww31-9C7.pdf 09 Mar 2024 2 0.28 Mb
5 Comet 419F Replacement manual comet/419f-366.pdf 24 Feb 2023 2 0.44 Mb
6 Toshiba TLP680U - SXGA LCD Projector Owner's manual toshiba/tlp680u-sxga-lcd-projector-78I.pdf 22 Sep 2023 54 0.94 Mb

Similar Resources:

  • Slant/Fin

    VGH-299-CH

    (128 pages)
    E93.1601EN032C MODELS VGH-299-CH, VGH-399-CH and VGH-500-CH HIGH EFFICIENCY CONDENSING GAS BOILER QUICK CONTENTS FULL TABLE OF CONTENTS ................................. 2 1.0 SAFETY GUIDELINES ........................................... 6 2.0 INTRODUCTION. ................................................... 8 3.0 TECHNICAL DATA ......... …
  • Slant/Fin

    VICTORY VSPH SERIES

    (28 pages)
    • Cast-iron • Gas-fired • Sealed combustion • Hot water boiler • Direct vent or Category IV venting flexibility • Wall mounted®INSTALLATION AND OPERATING INSTRUCTIONSContents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PageSpecifications and Dimensions . . . . . . . . . . . . . . . . . . .2Installation RequirementsLocation …
  • Rendamax

    R600 EVO

    (3 pages)
    Gas filter (Trigon XL) Filtro de gas (Trigon XL) Gaz filtresi (Trigon XL) Gasfilter (Trigon XL) Plynový filtr (Trigon XL) газовый фильтр (Trigon XL) Gasfilter (Trigon XL) Gas filter (Trigon XL) Gázszűrő (Trigon XL) Filtre à gaz (Trigon XL) Gasfilter (Trigon XL) Filtr gazu (Trigon XL) Filtro gas (Trigon XL) φίλτρο � …
  • Baxi

    Platinum 2 Combi 28 GA

    (56 pages)
    © Baxi Heating UK Ltd 2011Platinum 2 Combi GA RangeGas Fired Wall Mounted CondensingCombination BoilerInstallation & Servicing InstructionsThese instructions include the Benchmark Commissioning Checklist and should be left with the user for safe keeping.They must be read in conjunction with the Flue Installation Guide. …
  • UTICA BOILERS

    MGB50

    (28 pages)
    P/N 37611601, Rev. B [02/09]RAn ISO 9001-2000 Certified CompanyMGB SERIES Cast Iron Gas Fired Boilers For Forced Hot WaterINSTALLATION, OPERATION & MAINTANANCE MANUALUTICA BOILERSP.O. Box 4729 Utica, NY 13504-4729 MEMBER: The Hydronics InstituteMODEL NUMBERS:MGB50 MGB75 MGB100MGB125 MGB150 MGB175MGB200 MGB250 MGB300National Excelsior Company www.excels …
  • Ferroli

    PEGASUS F3 N 2S Series

    (68 pages)
    PEGASUS F3 N 2SIT - ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONEES - INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTOTR - KULLANMA, KURULUM VE BAKøM TALIMATLARøEN - INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCEFR - INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIENU. - ȱɇɋɌɊɍɄɐȱə Ɂ ȿɄɋɉɅɍȺɌȺ …

Comments, Questions and Opinions: