  • GE NX-6, Page 35 LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA CUSTOMIZING ZONE TYPES (GROUPS) 110 28 ZONE TYPE 1 ALARM EVENT CODE 8 __ ZONE TYPE 1 CHARACTERISTIC SELECTION Segment #1 1 - Fire (enable for fire zone) “ 2 - 24 Hour (enable for non-fire 24 hour zone) “ 3 - Keyswitch zone “ 4 - Follower (enable for burg zones that are instant during non-entry times) “ 5 - Delay 1 zone (enable to follow Timer #1 Entry/Exit) “ 6 - Delay 2 zone (enable to follow Timer #2 Entry/Exit) “ 7 - Interior (Enable for auto bypass or stay arming) “ 8 - Local Only (enable if zone is not to be reported) “ Segment #2 1 - Keypad aud

  • GE NX-6, Page 19 NOTE: To null a zone, program the zone in APartition Select@ as zero (0) in all partitions and do not use end-of-line resistors. LOCATION 25 ZONE TYPE FOR ZONES 1-8 8 segments, numerical data Location 25 contains the zone type (configuration) for zones 1-8. Segment 1 is for zone 1, and Segment 8 is for zone 8. Default zone types are found in the Table 1.1 on page 18. To customize a zone type, see loc. 110 - 149, page 28. LOCATION 26 PARTITION SELECT, ZONES 1-8 8 segments, feature selection

  • Page 15 LOCATION 10 EVENTS REPORTED TO PHONE #2 2 segments of feature selection Phone #2 can be used to back up Phone #1 or for a second receiver to multi-report or split report events. Phone #2 has two programming locations that are used to select which events are reported to this phone number. Location 10 is used to select which events are reported to Phone #2, and locat

  • GE NX-6, Page 33 LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA AUXILIARY OUTPUT #2, EVENT & TIME 48 22 Segment #1: Program the event number for output #2 Segment #2: Program the timing for output #2 1=Fire alarm 10 seconds ___ ___ AUXILIARY OUTPUT #3, EVENT & TIME 49 22 Segment #1: Program the event number for output #3 Segment #2: Program the timing for output #3 2= 24 Hour Alarm 10 seconds ___ ___ AUXILIARY OUTPUT #4, EVENT & TIME 50 22 Segment #1: Program the event number for output #4 Segment #2: Pro

  • GE NX-6, Page 26 LOCATION 76 LOG FULL 2 segments, numerical data Location 76 contains the tens and ones digits for a 4+2 format if the "Log Full Reporting" is enabled. Segment 1 contains the tens digit, segment 2 contains the ones digit. LOCATION 77 OPENING 2 segments, numerical data Location 77 contains the tens digit of a 4+2 format if the "Opening Reporting" is enabled. The ones digit is the ones digit of the user number that did the opening. If the user is greater than 9, the numbers will begin repeating. If it is required to report openings and closings for more than 9 users, Contact ID or SIA format must be used.

  • GE NX-6, Page 42 BOARD INSTALLATION Inside the can, several 2-holed insertion points have been constructed. This allows for either vertical or horizontal placement of the modules. Notice that each insertion point has two sizes of holes B a larger hole and a smaller hole. Diagram 1 : The black plastic PCB guides are grooved on one edge where the PC board will be seated. The end with the half-moon protrusion fits into the larger hole. The smaller hole is for the screw. Diagram 2 : Place the first black plastic PCB guide in the top insertion point, grooved edge downward. The half-moon protrusion will be in the large hole. It does not require force. Insert one of the p

  • GE NX-6, Page 32 LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA KEYPAD SOUNDER CONTROL 39 20 1 - Keypad sounds for Telephone Line Cut when in the Armed state “ 2 - Keypad sounds for Telephone Line Cut when in the Disarmed state “ 3 - Keypad sounds upon AC Power Failure “ 4 - Keypad sounds upon Low Battery Detection “ 5 - Keypad sounds during Cross Zone Trip Time “ 6 - Keypad sounds for Tamper Alarm “ 7 - Reserved. 8 - Keypad sounds for expander trouble (required for UL) “ SYSTEM TIMERS Seg # 40 20 1 - Dynamic Battery Test duration (0-255 minutes) 2 - AC Failure report delay (0-255 minutes) 3 - Power Up Delay (0-

  • GE NX-6, Page 22 LOCATION 47 AUXILIARY OUTPUT #1, EVENT AND TIME 2 segments, numerical data Segment 1 Use Table 2.1 to select the event that will activate Auxiliary Output 1. Segment 2 Program the timing from 0-255 (minutes or seconds, depending on data programmed in Segment 1, Location 46). Programming a "0" makes the output follow the event. LOCATION 48 AUXILIARY OUTPUT #2, EVENT AND TIME 2 segments, numerical data Segment 1 Use Table 2.1 to select the event that w

  • GE NX-6, ANSI / SIA CP-01 REQUIREMENTS To meet SIA CP-01 requirements – • Minimum System Requirements: 1 control panel; 2 keypads (or 1 keypad per partition for multi-partitioned systems) • Remote arming shall NOT be enabled in SIA classified installations. • Off-premise transmission must be in the SIA format. • The Abort window and Entry Delay must not exceed 1 minute. • CAUTION – A call waiting cancel on a non-call waiting line will prevent successful connection to the central station. CP-01 Feature Description Feature Description as shown in manual Program Loc Seg / Opt Factory Default CP-01 Required Setting

  • GE NX-6, Page 34 LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA SENSOR LOW BATTERY COMMUNICATOR CODE 60 24 Segment #1: Partition #1 Sensor Low Battery Code Segment #2: Partition #2 Sensor Low Battery Code 0 0 ___ ___ SENSOR MISSING COMMUNICATOR CODE 61 24 Segment #1: Partition #1 Sensor Missing Code Segment #2: Partition #2 Sensor Missing Code 0 0 ___ ___ 62 24 DURESS 0-0 __ __ 63 24 AUXILIARY 1 0-0 __ __ 64 24 AUXILIARY 2 0-0 __ __ 65 25 KEYPAD PANIC 0-2 __ __ 6

  • Page 5 Fail to Communicate The NX- 6 will illuminate the "Service" LED if a report fails to reach the central station. If enabled, when the next report is successfully communicated, a “Fail to Communicate” code will be reported. (Loc. 37, pg. 19) Fire Alarm Verification When enabled, the NX- 6 will verify a Fire alarm by requiring more than one trip on a smoke detect

  • GE NX-6, Page 14 Table 1.1 Segment 1 1 Alarms and Alarm Restores 2 Opening and Closings 3 Zone Bypass and Bypass Restores 4 Zone Trouble and Trouble Restores 5 Power Fail, Low Battery, Power Restore, and Low Battery Restore 6 Bell Cut , Telephone Line Cut, Bell Cut Restore, Telephone Line Restore 7 Test Reports 8 Start and End programming, Download complete Segment 2 1 Zone and Box Tamper and Tamper Restore 2 Auxiliary Power Overcurrent and Restore 3 Wireless Sensor Missing and Restore 4 Wireless Sensor Low Battery and Restore 5 Expander Trouble and Restore 6 Fail To Communicate

  • GE NX-6, Page 43 REGULATORY NOTICES LOCAL TELEPHONE COMPANY INTERFACE Telephone Connection Requirements Except for telephone company provided ringers, all connections to the telephone network shall be made through standard plugs and standard telephone company provided jacks or equivalent in such a manner as to allow for immediate disconnection of the terminal equipment. Standard jacks shall be so arranged that if the plug connected thereto is withdrawn, no interference to the operation of the equipment at the customers’ premises which remains connected t

  • GE NX-6, Page 8 PROGRAMMING THE LED KEYPADS This section describes how to program the address and partition of each keypad as well as the options that are available. The address of the keypad is important because this is how the panel supervises the keypads. The factory default for the Master code is [1]-[2]-[3]-[4] when using a 4-digit code or [1]-[2]-[3]-[4]-[5]-[6] for a 6-digit code. The factory default for the "Go To Program" code is [9]-[7]-[1]-[3] for a 4-digit code or [9]-[7]-[1]-[3]-[0]-[0] for a 6-digit code. SET STARTING ZONE (Refer to f

  • GE NX-6, Page 2 GENERAL DESCRIPTION The NetworX NX-6 represents a new approach to security systems design. Drawing on our experience in the world market as the largest exporter of USA manufactured controls, we have developed the most flexible, durable, and user- friendly control ever seen in our industry. Featuring sophisticated software which allows up to 40 users to interface with 16 zones, 2 partitions, and a host of integrated fire, access, verification, and input/output modules, all reported with the most comprehensive and fast SIA

  • GE NX-6, Page 23 LOCATION 51 AUTOTEST CONTROL 4 segments, numerical data Segment 1 Program a "1" if the interval is to be in hours. Program a "0" if in days. Program a A2" to suppress the daily test or a A3" to suppress the hourly test if any report has been sent. Segment 2 Program the Autotest interval from 1-255 hours/days. Segment 3 Program the Autotest report hour in 24-hour format (if the interval is in hours, this segment is ignored). Segment 4 Program the Autotest report time, number of minutes after the hour. LOCATION 52 OPENING TIME

  • GE NX-6, Page 41 TERMINAL DESCRIPTION TERMINAL DESCRIPTION R1 House Telephone Ring (Grey) R Telephone Ring (Red) T Telephone Tip (Green) T1 House Telephone Tip (Brown) EARTH Earth Ground. Connect to a cold water pipe or a 6 to 10 foot driven rod. AC AC input. Connect to a 16.5V 25, 40 or 50 VA Class ll U.L. approved transformer. BELL + & BELL - If used as a siren output(default), the speaker rating should be 15 watt at 8 or 16 Ω, or 30/40 watt at 4, 8, or 16 Ω. If voltage output is selected in location 37, this output becomes voltage output, 12VDC, 1 Amp

  • Page 24 SLOW FORMAT COMMUNICATOR CODES LOCATIONS 56- 83 ARE ONLY USED WHEN REPORTING EVENTS TO A PAGER OR USING A SLOW FORMAT SUCH AS 4+2. WHEN USING CONTACT ID OR SIA, THERE IS NO NEED TO PROGRAM THESE LOCATIONS. LOCATION 56 RESTORE 2 segments, numerical data Location 56 contains the event code for a zone "Restore" for a 4+2 f

  • © 2005 GE Security All rights reserved. These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to be met during installation, operation, and maintenance. If further information is desired or if particular problems arise that are not covered sufficiently for the purchase

  • GE NX-6, Page 30 LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA PHONE #3, SELECT EVENTS TO REPORT TO PHONE #3 16 15 Segment #1 1 - Alarms and Restores “ 2 - Open / Close “ 3 - Bypass “ 4 - Zone Trouble “ 5 - Power Trouble (AC Fail or Low Battery) “ 6 - Siren & Telephone Fault “ 7 - Test Reports “ 8 - Program, Download, & Log Full “ Segment # 2 1 - Tampers “ 2 - Short Circuit “ 3 - Sensor Lost “ 4 - Sensor Low Battery “ 5 - Expander Trouble “ 6 - Failure to Communicate “ 7 - Reserved 8 - Reserved PHONE #3 SELECT WHICH PARTITIONS

  • GE NX-6, Page 21 LOCATION 41 SPECIAL FEATURES 1 segment, feature selection â On enables the 6-digit code option. If 6-digit option is enabled, all arm/disarm codes and the "Go To Program Code" are 6 digits. If this option is enabled, the default user #1 code is [1]-[2]-[3]-[4]-[5]-[6]. NOTE: IF YOU ENABLE THIS OPTION, VERIFY THAT THE "GO TO PROGRAM CODE" IS A 6-DIGIT CODE BEFORE EXITING PROGRAMMING. ã On requires code entry for [r]-[9]-[8] ACall back for download@ and [r]-[9]-[9] AAnswer incoming call for download@ functions. ä On enables

More Instructions:

DOWNLOAD

Related Products and Documents (Control Panel):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sharp LC-26BD1 Quick start manual sharp/lc-26bd1-XHL.pdf 27 Jul 2022 12 1.46 Mb
2 Surefire MILLENNIUM M3 Combatlight Manual  surefire/millennium-m3-combatlight-MRN.pdf 07 Nov 2023 11
3 Sony CDP-CX260 - 200 Disc Cd Changer Operating instructions manual sony/cdp-cx260-200-disc-cd-changer-593.pdf 26 Apr 2023 40 0.77 Mb
4 Osaki OS Pro 3D Cyber Instruction manual osaki/os-pro-3d-cyber-6Y6.pdf 22 Jan 2023 11
5 SHIFTER ZR4 Installation manual shifter/zr4-VG9.pdf 09 Feb 2023 2
6 COMPANION 315.101810 Operator's manual companion/315101810-S3K.pdf 21 Jan 2023 18

Similar Resources:

  • Siemens

    SINUMERIK 828D Turning

    (926 pages)
    Turning ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ SINUMERIK SINUMERIK 840D sl/ …
  • Honeywell

    DeltaNet FS90

    (2 pages)
    OPERATING INSTRUCTIONS74-5069DeltaNet FS90 Operating InstructionsSYSTEM OPERATIONA normally functioning DeltaNet Fire & Security System is indicated by the green RUN and green POWER LEDs on the powered Control Board. If a Communication Board is installed, the Communication Board red TRANSMIT and RECEIVE LEDs blink as data is communicated.Power Supply S …
  • Observer

    TSTAT0201CW

    (56 pages)
    616 02 1019 00 10/17/14Communicating Wall ControlWith Wi--Fir CapabilityOwner’s ManualTSTAT0201CWU.S. Patent No. 7,243,004U.S. Patent No. 7,775,452COMMUNICATING SYSTEMRAll trademarks are the property of the respective owners.Wi-Fi®is a registered trademark of the Wi-Fi Alliance Corporation. …
  • Siemens

    SINAMICS G120

    (2 pages)
    Removing Covers21Top, FSD ... FSFBreak out and use cable gland for connecting the DC Link Screw driverRemoving Covers3Bottom, FSD, FSE122Bottom, FSF1Height - Power ModuleLower screening shieldWidthDepth with CU DepthHeight - totalUpper screening shieldDimensions, Drill patterns, Fixingsh cbOnly install in a vertical upright position with line and motor conec …
  • ENMET

    CP-60

    (23 pages)
    ENMET PO Box 979 Ann Arbor, MI 48106-0979 www.enmet.com Manual Part Number 80003-501 MCN-423, 07/15/09 CP-60 OPERATION AND MAINTENANCE MANUAL …
  • CBE

    PC380-BS

    (60 pages)
    PC380-BSISTRUZIONI D’USOUSER’S MANUALBEDIENUNGSANLEITUNGINSTRUCTIONS D’EMPLOINEW TECHNOLOGYELECTRONICS FOR CARAVANNINGITDEENFRed. 06/2020 cod. 000510 Rev.03 …

Comments, Questions and Opinions: