Voltronic Power Winner series Operation & User’s Manual

Voltronic Power Winner series Manual Online:

3.8, 1725 votes
Voltronic Power Winner series User Manual
Voltronic Power Winner series User Guide
Voltronic Power Winner series Online Manual

Text of Voltronic Power Winner series User Guide:

  • Table of Contents 1. Important Safety Warning ............................................................................................... 1 1-1. Transportation ..................................................................................................... 1 1-2. Preparation ...............................................................................................

  • Voltronic Power Winner series, 1 1. Important Safety Warning Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read carefully the following instructions before installing the unit. Do not operate this unit before reading through all safety information and operating instructions carefully 1-1. Transportation  Please transport the UPS system only in the original package to protect against shock and impact. 1-2. Preparation  Condensation may occur if the UPS system is moved directly from cold to warm environment. The UPS system must be absolutely dry before being installed. Please allow

  • Voltronic Power Winner series, 2 1-5. Maintenance, service and faults  The UPS system operates with hazardous voltages. Repairs may be carried out only by qualified maintenance personnel.  Caution - risk of electric shock. Even after the unit is disconnected from the mains (building wiring outlet), components inside the UPS system are still connected to the battery and electrically live and dangerous.  Before carrying out any kind of service and/or maintenance, disconnect the batteries and verify that no current is present and no hazardous voltage exists in the terminals of high capability capacitor such as BUS-capacitors.  Only persons are adequately familiar with

  • Voltronic Power Winner series, 3 2. Installation and setup NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Please keep the original package in a safe place for future use. NOTE: There are two different types of online UPS: standard and long-run models. Please refer to the following model table. Model Type Model Type 1K Standard model 1KL Long-run model 2K 2KL 3K 3KL 1KR 1KRL 2KRL 3KRL 2-1. Rear panel view Tower Unit 1K (L) India 2K (L) India 3K(L) India 1K (L) IEC 2K (L) IEC 3K(L) IEC

  • Voltronic Power Winner series, 4 1K (L) Schuko 2K (L) Schuko 3K(L) Schuko 1K (L) Universal 2K (L) Universal 3K (L) Universal Rack Unit 1KR(L) Chinese 1KR(L) IEC 2KRL Chinese 2KRL IEC

  • Voltronic Power Winner series, 5 3KRL Chinese 3KRL IEC 1. AC input 2. Input circuit breaker 3. USB communication port 4. RS-232 communication port 5. SNMP intelligent slot 6. External battery connection (only available for L model) 7. Output receptacles 8. Output circuit breaker 9. Output terminal 2-2. Setup the UPS Step 1: UPS input connection Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords. The power cord is supplied in the UPS package. Step 2: UPS output connection  For socket-type outputs, simply connect devices to the outlets.  For terminal-type input or

  • Voltronic Power Winner series, 6 Step 4: Turn on the UPS Press the ON/Mute button on the front panel for two seconds to power on the UPS. Note: The battery charges fully during the first five hours of normal operation. Do not expect full battery run capability during this initial charge period. Step 5: Install software For optimal computer system protection, install UPS monitoring software to fully configure UPS shutdown. You may insert provided CD into CD-ROM to install the monitoring software. If not, please follow steps below to download and install monitoring software from the internet: 1. Go to the website http://www.power-software-download.com 2. Click ViewP

  • Voltronic Power Winner series, 7 3. Operations 3-1. Button operation Button Function ON/Mute Button  Turn on the UPS: Press and hold ON/Mute button for at least 2 seconds to turn on the UPS.  Mute the alarm: When the UPS is on battery mode, press and hold this button for at least 5 seconds to disable or enable the alarm system. But it’s not applied to the situations when warnings or errors occur.  Up key: Press this button to display previous selection in UPS setting mode.  Switch to UPS self-test mode: Press and hold ON/Mute button for 5 seconds to enter UPS self-testing while in AC mode, ECO mode, or converter mode. OFF/Enter Button

  • Voltronic Power Winner series, 8 Display Function Remaining backup time information Indicates the remaining backup time in pie chart. Indicates the remaining backup time in numbers. H: hours, M: minute, S: second Fault information Indicates that the warning and fault occurs. Indicates the warning and fault codes, and the codes are listed in details in 3-5 section. Mute operation Indicates that the UPS alarm is disabled. Output & Battery voltage information Indicates the output voltage, frequency or battery voltage. Vac: output voltage, Vdc: battery voltage, Hz: frequency Load information Indicates the load level by 0-25%, 26-50%

  • 9 3-3. Audible Alarm Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continuously sounding Bypass Mode Sounding every 10 seconds 3-4. LCD display wordings index Abbreviation Display content Meaning ENA Enable DIS Disable ESC Escape HLS High loss LLS L

  • Voltronic Power Winner series, 10 230: presents output voltage is 230Vac (Default) 240: presents output voltage is 240Vac For 100/110/115/120/127 VAC models, you may choose the following output voltage: 100: presents output voltage is 100Vac 110: presents output voltage is 110Vac 115: presents output voltage is 115Vac 120: presents output voltage is 120Vac (Default) 127: presents output voltage is 127Vac  02: Frequency Converter enable/disable Interface Setting Parameter 2 & 3: Enable or disable converter mode. You may choose the following two opt

  • Voltronic Power Winner series, 11 For 100/110/115/120/127 VAC models, the setting voltage in parameter 3 is from -3V to -12V of the nominal voltage. (Default: -6V)  06: Bypass enable/disable when UPS is off Interface Setting Parameter 3: Enable or disable Bypass function. You may choose the following two options: ENA: Bypass enable DIS: Bypass disable (Default)  07: Bypass voltage range setting Interface Setting Parameter 2 & 3: Set the acceptable high voltage point and acceptable low voltage point for Bypass mode b

  • 12 3-6. Operating Mode Description Operating mode Description LCD display Online mode When the input voltage is within acceptable range, UPS will provide pure and stable AC power to output. The UPS will also charge the battery at online mode. ECO mode Energy saving mode: When the input voltage is within voltage regulation range, UPS will bypa

  • Voltronic Power Winner series, 13 3-8. Warning indicator Warning Icon (flashing) Alarm Low Battery Sounding every second Overload Sounding twice every second Battery is not connected Sounding every second Over Charge Sounding every second Over temperature Sounding every second Charger failure Sounding every second Battery fault Sounding every second Out of bypass voltage range Sounding every second Bypass frequency unstable Sounding every second EEPROM error Sounding every second

  • Voltronic Power Winner series, 14 4. Troubleshooting If the UPS system does not operate correctly, please solve the problem by using the table below. Symptom Possible cause Remedy No indication and alarm even though the mains is normal. The AC input power is not connected well. Check if input power cord firmly connected to the mains. The AC input is connected to the UPS output. Plug AC input power cord to AC input correctly. The icon and flashing on LCD display and alarm is sounding every second. The external or internal battery is incor

  • 15 Symptom Possible cause Remedy Battery backup time is shorter than nominal value Batteries are not fully charged Charge the batteries for at least 5 hours and then check capacity. If the problem still persists, consult your dealer. Batteries defect Contact your dealer to replace the battery. Fault code is shown as 05 on LCD display. At the same time, alarm is c

  • Voltronic Power Winner series, 16 5. Storage and Maintenance Operation The UPS system contains no user-serviceable parts. If the battery service life (3~5 years at 25°C ambient temperature) has been exceeded, the batteries must be replaced. In this case, please contact your dealer. Storage Before storing, charge the UPS 5 hours. Store the UPS covered and upright in a cool, dry location. During storage, recharge the battery in accordance with the following table: Storage Temperature Recharge Frequency Charging Duration -25°C - 40°C Every 3 months 1-2 hours 40°C - 45°C Every 2 months 1-2 hours Be

  • Voltronic Power Winner series, 17 6. Specifications CAPACITY* 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W INPUT Voltage Range Low Line Transfer 160VAC/140VAC/120VAC/110VAC± 5% ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) Low Line Comeback 168VAC/148VAC/128VAC/118VAC ± 5 % ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) High Line Transfer 300 VAC ± 5 % High Line Comeback 290 VAC ± 5 % Frequency Range 40Hz ~ 70 Hz P

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 TerraTec Cameo 200 DV Manual  terratec/cameo-200-dv-25G.pdf 10 Dec 2022 31 0.73 Mb
2 Elite Screens Portable Mobile Stand Operation & user’s manual elite-screens/portable-mobile-stand-X18.pdf 31 Aug 2023 8 0.83 Mb
3 Uniden 2020 Instruction manual uniden/2020-DWR.pdf 10 Aug 2023 33 6.52 Mb
4 Singer 14U34B Parts list singer/14u34b-L62.pdf 29 Apr 2023 19 0.57 Mb
5 Norcold N621 - Parts list norcold/n621-S16.pdf 22 Dec 2023 10
6 HP Irvine Operation & user’s manual hp/irvine-QW5.pdf 14 Sep 2023 29

Similar Resources:

  • PowerWalker

    VFI 1000 AT

    (6 pages)
    1 ENGLISH PowerWalker VFI 1000-3000 AT Quick Guide LCD Panel The UPS has an LCD panel with 6 pages to scroll. Left side: Input Voltage [V] Right side: Output Voltage [V] Left side: Input frequency [Hz] Right side: Output frequency [Hz] Left side: Load level [%] Right side: Load in kW Left side: Load level [%] Right side: Load in kVA Left side: Battery …
  • OPTI-UPS

    OD330

    (2 pages)
    Outdoor&EATURES4HESE503AREMADETOBEEITHERMOUNTEDORUSEDASATOWER4HEBATTERYCHARGERISONEOFTHEFASTESTINTHEMARKET5PTOHOURSOFBACKUPTIME,%$DISPLAYBATTERYBACKUPBATTERYMODEORBATTERYFAULT%-)2 …
  • Powerware

    5110

    (2 pages)
    Powerware 5110 UPSUSER'S MANUALThe Powerware 5110 uninterruptible power system (UPS) protects your sensitive electronic equipment from power problems such as power failures, power sags, power surges, brownouts, and line noise. Features:Processor-controlled voltage regulationEight outlets -Four with surge and backup protection-Four with surge protection …
  • Eaton

    DDC-250/2

    (2 pages)
    1/2Instruction LeafletMontageanweisungNotice dinstallationInstrucciones de montajeIstruzioni per il montaggio安安装说明装说明Инструкция по монтажуMontagehandleidingMontagevejledningΟδηγίες εγκατάστασηςInstruções de montagemMonteringsanvisningAsennusohjeNávod k montáiPaigaldusjuhendSzerelési utasításM …
  • Xtreme

    1000VA

    (25 pages)
    XVRT Line Interacve UPS1000VA, 1500VA, 2200VA, 3000VA ModelsUser & Installaon Manualwww.xpcc.com | © 2014 Xtreme Power Conversion Corporaon. All rights reserved. (Rev 11/20/14) …
  • SEI

    1800/48-2U-P-ACC

    (13 pages)
    Installation and Operations Manual SEI 1800/48-2U-P-ACC DC-UPS SEI Incorporated 5115 Pegasus Court, Suite Q Frederick, Md 21704 Phone 301-694-9601 Fax 301-694-9608 Email [email protected] Web http://www.seipower.com …

Comments, Questions and Opinions: