Manualios.com

WhisperKool 2500 CABINET System Manual

WhisperKool 2500 CABINET Manual Online:

4.9, 2655 votes
WhisperKool 2500 CABINET User Manual
WhisperKool 2500 CABINET User Guide
WhisperKool 2500 CABINET Online Manual

Text of WhisperKool 2500 CABINET User Guide:

  • WhisperKool 2500 CABINET, WK25 031114 We manufacture, test and certify 100% of our wine cooling units in the USA. By sourcing the best components and closely controlling our manufacturing processes, we can assure the highest-quality, lowest defect manufacturing rates in the industry. Copyright © 2012. WhisperKOOL. All rights reserved. WhisperKOOL copyrights this manual, the product design, and the design concepts, with all rights reserved. Your rights with regard to the hardware and manual are subject to the restrictions and limitations imposed by the copyright laws of the USA. Under copyright laws, this manual may not be copied, reproduced, translated, t

  • WhisperKool 2500 CABINET, www.whisperkool.com | Page 1 TABLE OF CONTENTS WK 2500 Quick Reference Guide ....................... Note to Customer ...................................... Liquid Measuring Thermometer ....................... System Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Controller Operation .................................. Testing the Refrigeration Unit ......................... Cool Down Period ...................................... Normal Operation and Maintenance .....

  • www.whisperkool.com | Page 3 Thank you for purchasing a WhisperKOOL wine cabinet unit. Our main goals are customer satisfaction and providing the best wine storage solutions on the market. If you have any questions or comments, please feel free to contact us at 1-800-343-9463 or [email protected]. It is mandatory that you DO NOT plug in or start your new WhisperKOO

  • WK25 031114 Page 4 | 1-800-343-9463 By measuring the temperature of the liquid, the temperature reading will be consistent and the unit will only run when it needs to. To Install the Thermostat: 1. Fill an empty wine bottle to its neck with room temperature water. 2. Press bottle probe securely into bottle. 3. Place the bottle with probe into a level rack sp

  • WhisperKool 2500 CABINET, www.whisperkool.com | Page 5 SYSTEM OPERATION WHISPERKOOL 2500 Initial Start-Up When the unit is rst turned on, the control will briey display all symbols and the green snowake symbol will appear if the unit is calling for cooling. There may be a brief delay prior to the evaporator fan turning on, as it will not start until the probe temperature drops to below 70°F. When the fan is activated, the fan symbol will be displayed. The Advance Product Safety Technology (APST) ensures

  • WhisperKool 2500 CABINET, WK25 031114 Page 6 | 1-800-343-9463 SYSTEM OPERATION WHISPERKOOL 2500 CONT. Ambient Temperature The cooling system in the cabinet has the ability to cool a maximum of 20°F below the ambient temperature in the room. The optimal temperature for wine storage is 55°F, make sure that the temperature of the room in which the cabinet will be placed does not exceed 75°F. To ensure a consistent temperature, make sure the room temperature does not dip below 55°F. Ventilation The cabinet must have adequate ventilation to allow the exhaust side of the cooling unit to opera

  • WhisperKool 2500 CABINET, www.whisperkool.com | Page 7 WHISPERKOOL SERIES ADVANCED CONTROLLER Button Functions ON/OFF • The ON/OFF button turns the refrigeration system on or o. This feature does not disconnect power from the unit. The condenser fan will continue to run in the OFF position. In order for the power to be shut o from the unit, the power cord must be unplugged from the wall. Up and Down buttons • Use these buttons to scroll through the control panel menu. • These also display the highest and lowest temperature sensed by the bottle probe. This feature allows the customer instant access to the record

  • WK25 031114 Page 8 | 1-800-343-9463 WHISPERKOOL SERIES ADVANCED CONTROLLER CONT. Cellar Pre-Chill (cont.) 2. The CPC feature can be adjusted to the customer’s specic needs by accessing the control panel menu. Note: This feature is not available on the remote keypad application. Set 1. Press the “Set” button once and it will display the set point. After about 5 s

  • WhisperKool 2500 CABINET, www.whisperkool.com | Page 9 WHISPERKOOL SERIES ADVANCED CONTROLLER CONT. Customer Preference Selection Menu (cont.) CON/COF — Compressor on time (CON) and o time (COF) with a Probe 1 failure alarm: These parameters are set at CON 40 minutes and COF 10 minutes. In the event that there is a Probe 1 failure alarm, the compressor/refrigeration system automatically starts a predetermined ON/OFF cycle, which is controlled by the CON and the COF parameters. The customer can adjust these parameters to maintain the desired bottle probe temperature. During a Probe 1 failure alarm, the bottle probe temper

  • WhisperKool 2500 CABINET, WK25 031114 Page 10 | 1-800-343-9463 TESTING THE REFRIGERATION UNIT Remember, do not start or plug in your unit for 24 hours after delivery. Many units are placed on their sides during shipping, which may allow compressor oil to escape their reservoirs. Premature starting before the oil has had a chance to resettle can cause damage to the compressor and result in a lack of cooling. Before you ll the cabinet with wine, you’ll want to check the operation of the unit. All cabinets successfully pass quality control at the Vinothèque facility. Periodically a unit’s cooling system is damaged in transport. Simply turn the unit on for about one hour and conrm tha

  • WhisperKool 2500 CABINET, www.whisperkool.com | Page 11 NORMAL OPERATION MAINTENANCE The cooling unit will cycle on and o as needed once the temperature has stabilized and the initial “cool- down” has been completed. The condensate evaporator and temperature equalizer switches may be turned o for normal operation. — Thermostat: Should be 55°F or desired wine temperature. Maintenance WhisperKOOL recommends vacuuming of the condenser ns located in the rear of the cabinet every three months. A partially obstructed condenser dramatically reduces the eciency of the cooling unit. Monthly: — Check lters — Che

  • WK25 031114 Page 12 | 1-800-343-9463 TROUBLESHOOTING Problem Likely Cause Solution System will not start Tripping circuit breaker Reset breaker, verify dedicated 20 amp outlet and not on ground fault interrupter Temperature setting is wrong Adjust your set temperature Wine probe disconnected Assure probe line is in a bottle of water and is not stretched. Check connections. Runs const

  • WhisperKool 2500 CABINET, www.whisperkool.com | Page 13 INSTALLATION TERMS AND CONDITIONS WHISPERKOOL COOLING SYSTEM WHISPERKOOL PRODUCT BASE TERMS WhisperKOOL Corporation (“WhisperKOOL”) is in the business of manufacturing and selling wine cabinets, cooling units and related goods; each such wine cabinet, cooling unit and related good is referred to herein as a “Product”. As used herein, the term “WhisperKOOL” includes any Product sold under the names WhisperKOOL, Vinotheque and CellarCool. “Purchaser” means the original purchaser of a WhisperKOOL Product. “End User” means the consumer who has installed and is actually using a WhisperKOO

  • WhisperKool 2500 CABINET, WK25 031114 Page 14 | 1-800-343-9463 3. PRODUCT INSTALLATION REQUIREMENTS a. Prior to installing a WhisperKOOL Product, the End User must read the WhisperKOOL Owner’s Manual and thereafter the End User must follow the required installation, use and maintenance procedures set forth by WhisperKOOL in WhisperKOOL’s Owner’s Manual. The Owner’s Manual is shipped with each Product and if another copy is needed, replacement copies can be downloaded from WhisperKOOL’s website (www. whisperkool.c

  • WhisperKool 2500 CABINET, www.whisperkool.com | Page 15 TECHNICAL ASSISTANCE For WhisperKOOL 2500: Check Right side of unit on a silver sticker. Model ___________________________________________ Serial Number _____________________________ Installed by _______________________________________________ Date _____________________________ A WhisperKOOL Customer Service is available Monday through Friday from 6:00 a.m. to 4:00 p.m. Pacic Standard Time. The appointed customer service representative will be able to assist you with your questions and warranty information more eectively if you provide them with the follow

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 HP StorageWorks X1800sb - Network Storage Blade Operation & user’s manual hp/storageworks-x1800sb-network-storage-blade-WQT.pdf 09 Mar 2024 102 2.45 Mb
2 Jet JFM-5 Operating instructions and parts manual jet/jfm-5-1F7.pdf 23 Dec 2022 24
3 Hunter 20168 Owner's manual and installation manual hunter/20168-AW9.pdf 03 Nov 2023 15
4 Nat AA35-001 Operation manual nat/aa35-001-EHV.pdf 27 Mar 2023 17
5 Harman Kardon AVR 230 Owner's manual harman-kardon/avr-230-A1T.pdf 18 Mar 2024 52 0.93 Mb
6 Kenmore 27-Inch Wide GAS DRYERS Owner's manual and installation instructions kenmore/27-inch-wide-gas-dryers-TW2.pdf 09 Mar 2023 80

Similar Resources:

  • LG

    LW8000PR

    (39 pages)
    Room Air Conditioner SERVICE MANUALCAUTION- BEFORE SERVICING THE UNIT, READ THE SAFETYPRECAUTIONS IN THIS MANUAL.- ONLY FOR AUTHORIZED SERVICE.MODEL: LW8000PRLW8000ERLW8000ERY3WEBSITE http://biz.LGservice.comE-MAIL http://www.LGEservice.com/techsup.html …
  • Fujitsu

    V09LA

    (2 pages)
    (V09LA)(V12LA)ACCESSORY Q’tyDrain pipe1Decide the mounting position with the customer as follows:(1)If possible, do not install the unit where it will be exposed to direct sunlight.(If necessary, install a blind that does not interfere with the air flow.)(2)Do not install the unit where a strong wind blows or where it is very dusty.(3) Do not install the u …
  • Carrier

    24ACB7 Comfort

    (2 pages)
    Wiring Diagram24ACB7Comfortt17 2---Stage Air Condit io nerwith Puronr Refrigerant1 --- 1 / 2 t o 5 To n s NOTES:1. Symbols are electrical representation only.2. Compressor and fan motor furnished with inherent thermal protection.3. To be wired in accordance with National Electric N.E.C. and local codes.4. N.E.C. class 2, 24 V circuit, min. 40 VA r …
  • Panasonic

    CS-ME 7CKPGCS-ME10CKPG

    (220 pages)
    ENGLISH1MULTI Inverter AIR CONDITIONERINDOOR UNITOPERATING INSTRUCTIONSModel CS-ME 7CKPGCS-ME10CKPGCS-ME12CKPGCS-ME14CKPGCS-ME18CKPGF563678Before operating this product, please read instructionscarefully and save this manual for future use.MATSUSHITA ELECTRIC INDUSTRIAL CO.,LTD.AIR CONDITIONER DIVISION2-3-1-1,NOJIHIGASHI,KUSATSU,SHIGA,JAPANENGLISH ....... …
  • Whynter

    ARC-148MS

    (24 pages)
    WHYNTER 14,000 BTU PORTABLE AIR CONDITIONER Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully before using this product. Keep this manual in a safe place for future reference. Model # : ARC-148MS INSTRUCTION MANUAL …
  • Seifert

    Progressive Series

    (23 pages)
    Version Nr. 1-10 - 25.07.2022 Doc. No. 99870820201USL 1 / 23Table of Content 870820201USL1. User manual 2 .................................................................................................................................. 2. Legal regulations 2 .................................................................................................. …

Comments, Questions and Opinions: