Xtreme Power Conversion P90 1000VA User & Installation Manual
|
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 42 Uninterrupble Power Supply Baery Replacement If your baery box is not installed with baeries, please follow proper procedure to put baeries inside of unit. NOTE: MAKE SURE THAT THE BATTERY BOX IS DISCONNECTED FROM THE UPS BEFORE PERFORMING THE FOLLOW- ING SEQUENCE OF OPERATIONS. P90-BP48 Step 1 : Open the package and place the baery box on a horizontal plane. Step 2: Remove the removable front panel part by pulling it from the lower extremity Step 3: Remove the xed part of the front panel by removing the 2 screw present. S
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 30 Uninterrupble Power Supply Troubleshoong If the UPS does not operate correctly, please use the table below to troubleshoot the problems. Symptom Possible cause Remedy No indicaon and alarm even though the ulity is normal. The AC input power is not con- nected well. Check that the input power cord is rmly connected to the ulity. The AC input is connected to the UPS output. Plug the AC input power cord into the AC input ulity correctly. The icon and the warning code are ashing on LCD dis
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 31 Uninterrupble Power Supply Fault code is shown as 01, 02, 03, 04, 11, 12, 13 and 41 on LCD dis- play and alarm is sounding connu- ously. A UPS internal fault has occurred. There are two possible results: 1. The load is sll supplied, but directly by AC ulity via bypass. 2. The load is no longer supplied with power. Contact your dealer for support. Baery backup me is shorter than expected. Baeries are not fully charged. Charge the baeries for at least 5 hours and then re-check capacity. If the problem sll exists, contact your dealer for suppor
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 2 Uninterrupble Power Supply Table of Contents Introducon.................................................................................................6 Product Descripon.....................................................................................6 Double Conversion Online Technology............................................................................................6 Diagnosc Tests......................................................................................
Xtreme Power Conversion Corporaon P90 User’s Manual Page 10 Uninterrupble Power Supply Emergency Power O (EPO) Port A customer supplied switch located remotely can be used to close the EPO connecon and allows the UPS output receptacles to be switched o. Since the EPO shuts down the equipment immediately, orderly shutdown proce- dures are not followed by any power
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 34 Uninterrupble Power Supply Obtaining Service If the UPS requires Service: 1. Use the TROUBLESHOOTING secon in this manual to eliminate obvious causes. 2. Verify there are no circuit breakers tripped. 3. Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the problem, call Xtreme Power Conversion Corp Technical Support at 800.582.4524. Technical support inquiries can also be made at [email protected]. Please have the following informaon available BEFORE calling the Technical Support Departmen
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 7 Uninterrupble Power Supply Diagnosc Tests When the UPS is started, a diagnosc test is automacally executed, checking the electronics and baeries, report- ing any problems on the LCD display. System Conguraon The UPS device and the internal baeries make up the system. Depending on the site and load require- ments of the installaon, certain addional opons are available for the soluon. Planning a UPS
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 3 Uninterrupble Power Supply Obtaining Service.......................................................................................34 Xtreme Power Conversion Limited Warranty...............................................35 Xtreme Power Conversion Load Protecon Policy.......................................36 Appendix A: P90-BP48 & P90-BP72 User Guide...........................................39 Important Safety Instrucons................................................................................................
Xtreme Power Conversion Corporaon P90 User’s Manual Page 32 Uninterrupble Power Supply Storage And Maintenance Storage Before storing, charge the UPS at least 5 hours. Store the UPS covered and upright in a cool, dry locaon. During storage, recharge the baery in accordance with the following table: Storage Temperature Recharge Frequency Charging Duraon -25°C - 40°C E
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 12 Uninterrupble Power Supply UPS Installaon Installaon and wiring must be performed in accordance with the local electrical laws and regulaons, and per- formed by appropriate personnel. For safety consideraons, the UPS is shipped from the factory with baery wires disconnected. Before installing the UPS, please follow these steps to connect the baery wires. Connecng the baeries Step 1 Step 2 Step 3 Remove the front panel Connect the baery wires Place the fr
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 14 Uninterrupble Power Supply Step 1 Use 4 screws to mount right and le rail sliders in front of rack. Step 2 Use 4 screws to mount right and le rail sliders in back of rack. Step 3 Place the nuts in the proper locaon in the rack based upon height of UPS.
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 5 Uninterrupble Power Supply For addional safety instrucons, please use the Safety Manual as a reference. Special Symbols The following symbols used on the UPS warn you of precauons: RISK OF ELECTRIC SHOCK - Please observe the warning that a risk of electric shock is present CAUTION: REFER TO OPERATOR’S MANUAL - Refer to the operator’s manual for addional informaon, such as important operang and maintenance instrucons. SAFE GROUNDING TERMINAL - Indicates primary safe ground LOAD ON/OFF – Pressing the buon turns on/o the output re
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 26 Uninterrupble Power Supply 08: Programmable Outlets Seng Interface Seng 0-999: seng the backup me limits in minutes from 0-999 for programmable outlets connected to non-crit- ical devices when operang in baery mode. 09: LCD Display Direcon Seng Interface Seng RAC: the LCD display is horizontal. TOE: the LCD display is vercal. 10: Acceptable Input Voltage Range Seng Interface Seng Choose the following Acceptable input voltage range: 55/150 alternang ashing: acceptable input voltage range
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 40 Uninterrupble Power Supply Rear Panel View 1. DC connector : connects to either UPS or 2nd baery box 2. DC breaker: Baery over-current protecon breaker 3. External baery numbers detecon port: detects the numbers of connected baeries. Installaon and Setup with UPS Unpacking & Inspecon 1. Remove the baery box from the packing. Note: The baery box is very heavy, be cauous when unpacking and liing the unit to avoid injury. 2. Check the inside package • Baery box unit • Quick guide • Baery connecon cabl
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 9 Uninterrupble Power Supply Communicaon Connecons To allow for unaended UPS shutdown/start-up and status monitoring, connect one end of the communicaon cable to the USB/RS232 port and the other to the communicaons port on your PC or server. With the monitoring soware installed, the UPS can be scheduled for shutdown/start-up and monitoring of the UPS status through the PC or server. RS232 Communicaons The RS-232 interface uses a 9-pin female D-sub connector. Informaon provided includes data about ulity, load and the UPS. The int
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 21 Uninterrupble Power Supply Display Funcon Backup me informaon Indicates the backup me in pie chart. Indicates the backup me in numbers. H: hours, M: minutes Warning & Fault informaon Indicates that the warning and fault occurs. Indicates the warning fault codes, and the codes are listed in details in this manual. Seng Operaon Indicates the seng operaon. Input / Output & Baery informaon Indicates the output/input voltage, output/input frequency or baery volt- age. V: output voltage, Hz: frequency Load informaon Indicates the
Xtreme Power Conversion Corporaon P90 User’s Manual Page 36 Uninterrupble Power Supply Xtreme Power Conversion Load Protecon Policy THIS POLICY IS NOT A WARRANTY. REFER TO THE XPC CORPORATION, INC. LIMITED WARRANTY FOR INFORMATION CONCERNING THE WARRANTY FOR YOUR XPC PRODUCT. THE LIMITATIONS AND CONDITIONS CONTAINED IN THIS POLICY DO NOT AFFECT
Xtreme Power Conversion Corporaon P90 User’s Manual Page 17 Uninterrupble Power Supply UPS Input Connecon Connect the UPS to an approved electrical input source consistent with the input power cord connecon provided with the UPS. Do not replace the power cord or use a substute. Avoid using extension cords when connecng AC input to any UPS. UP
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 48 Uninterrupble Power Supply Note: The cable connecon from the external baery connector to PCB is already present inside the baery box. All the other cable connecons should be made in accordance with the above wiring diagram. Storage & Maintenance The unit contains no user-serviceable parts. If the baery service life (3~5 years at 25°C ambient temperature) has been exceeded, the baeries must be replaced. In this case, please contact your dealer. Be sure to deliver the spent baery to a recycling facility or ship it to your dealer in the replacement baery packing mat
Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 43 Uninterrupble Power Supply Note: To install the second string of baeries, repeat the same procedure on the baery hold down brackets on the right side of the baery box. Step 6: Now, it is possible to put all baeries inside the unit by following the below picture (the following drawing are indicates the wire fastener posions for the correct baery placement). Note: To install the second string of baeries, repeat the same procedure on the right side of baery box. Step 7: Connect all baeries following the w
Xtreme Power Conversion NXRT?1000 UPS User & installation manual
NXRT?1000 |
Xtreme Power Conversion XVT 600VA UPS Operation & user’s manual
XVT 600VA |
Xtreme Power Conversion XPRT?1000 UPS User and installation manual
XPRT?1000 |
Xtreme Power Conversion XVT 600VA UPS User & installation manual
XVT 600VA |
Xtreme Power Conversion P90L-ISO6MB UPS User & installation manual
P90L-ISO6MB |
Xtreme Power Conversion NXRT?1000 UPS User & installation manual
NXRT?1000 |
Xtreme Power Conversion S70 Line?Interactive UPS User & installation manual
S70 Line?Interactive |
Xtreme Power Conversion NXRi-6KL UPS User & installation manual
NXRi-6KL |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Weslo | WLTL11310.0 | Operation & user’s manual | weslo/wltl11310-0-K4L.pdf | 01 Aug 2023 | 16 | 0.9 Mb |
2 | Hotpoint Ariston | ARXXF 125 | User manual manual | hotpoint-ariston/arxxf-125-W4Y.pdf | 29 Apr 2023 | 48 | |
3 | Nevir | NVR-466DU | Instruction manual | nevir/nvr-466du-2CT.pdf | 12 Aug 2023 | 12 | |
4 | Nilfisk-ALTO | ATTIX 30 H | Quick start manual | nilfisk-alto/attix-30-h-68P.pdf | 01 Aug 2022 | 28 | |
5 | Philips | HR2636 | Manual | philips/hr2636-Y9G.pdf | 21 Mar 2024 | 13 | |
6 | Audiovox | FD-250 | Owner's manual | audiovox/fd-250-629.pdf | 22 Oct 2022 | 8 | 0.25 Mb |
OPTI-UPS
21.PS800B / PS1000B / PS1500B / PS2200B / PS3000BFront PanelThe PSB Series are the only line interactive pure sinewave UPS designed to meet everyone's needs. Our full line covers every possible application demand. There are five tower models, from PS800B to PS3000B, and four rack-mount models, from PS1000B-RM to PS3000B-RM.Every PSB model utilizes digit …
Line Interactive UPS Series PS1000B-RM(3 pages) |
Panduit
UPS003LSM PA27224A01 Rev: 02 3-2014 UNINTERRUPTIBLE POWER SUPPLY LOAD SENSE MODULE OPERATION MANUAL © Panduit Corp. 2014 Original Instructions TO REDUCE THE RISK OF INJURY, USER MUST READ INSTRUCTION MANUAL Email: [email protected] EU Website: www.panduit.com/emea EU Email: emeatoolservicecenter @panduit.com www.panduit.com Technic …
UPS003LSM(8 pages) |
Tripp Lite
Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: SMART2200CRMXLSmartPro 2.2kVA Line Interactive Sine Wave UPS, 1900W, Extended-run, SNMPWEBCARD options, 4URack/Tower, USB, Serial, EPO, 120V Highlights2.2kVA / 2200VA / 1900W line interactive UPS, 0.86 power factor120V output, Corrects brown …
SmartPro SMART2200CRMXL(6 pages) |
Gematronic
GAMATRONIC ELECTRONIC INDUSTRIES LTD. 17 Hartom St., P.O.B. 45029, Jerusalem 91450, Israel Tel: 972-2-588-8222 Fax: 972-2-582-8875 Email: [email protected] Website: www.gamatronic.com SMART COMPACT UPS User’s Manual 650 VA 750 VA 1000 VA 1500 VA Release 1.8, November 2013 2MUXSMART-E
…
SCE-650(14 pages) |
Powercom
U P S Line-Interactive 425VA-1000VA IMD-1000AP, IMD-1000A, IMP-1000AP, IMP-1000A IMD-825AP, IMD-825A, IMP-825AP, IMP-825A IMD-625AP, IMD-625A, IMP-625AP, IMP-625A IMD-525AP, IMD-525A, IMP-525AP, IMP-525A IMD-425AP, IMD-425A, IMP-425AP, IMP-425A ■USER MANUAL■
…
425A/AP(8 pages) |
Powertronix
Service Manual PTX2-A3 UPS 6kVA~10kVA 220VAC
…
PTX2-A3(21 pages) |
Clarion CD Player XDZ716CD Player PDF Owner's manual XDZ716, 53 |
INSTEON Security System 2843-222Security System #63723X 2843-222, 8 |
Parkside Vacuum Cleaner PNTS 23 EOperation and safety notes for Parkside PNTS 23 E Vacuum Cleaner PNTS 23 E, 62 |
Asus Motherboard M3A32-MVP DELUXEM3A32-MVP DELUXE (Motherboard ePDF User Guide, #SRH33S) M3A32-MVP DELUXE, 176 |
GE Water Heater GEH50DEEJSUser Manual: GE GEH50DEEJS (NJT4I1, Upd.Sunday 24-09-2023) GEH50DEEJS, 80 |
Dixon Lawn Mower ZTR 7525PDF User Manual (@9V2N2Y), Dixon ZTR 7525 Lawn Mower (01st Dec 2023) ZTR 7525, 40 |
Sima Other SL-9Other PDF Operation & user’s manual SL-9, 3 |
Mountain Computer Computer Hardware Expansion ChassisMountain Computer Expansion Chassis Computer Hardware Operating manual Expansion Chassis, 43 |
STEINEL Kitchen Appliances IS 360 D TRIOSTEINEL IS 360 D TRIO Guide (Doc Type: Kitchen Appliances Operating instructions manual) IS 360 D TRIO, 42 |
Fieldpiece Measuring Instruments SMG5Fieldpiece SMG5 Guide (Doc Type: Measuring Instruments Operating manual) SMG5, 2 |
UP Aircrafts K2²UP K2² Aircrafts Owners manual and service manual K2², 55 |
Philips CD Player AZ9225Philips CD Player Specifications (File: philips-az9225-specifications-2, Fri 01.2024) AZ9225, 2 |