Manualios.com

Xtreme Power Conversion P90 1000VA User & Installation Manual

Xtreme Power Conversion P90 1000VA Manual Online:

4.9, 994 votes
Xtreme Power Conversion P90 1000VA User Manual
Xtreme Power Conversion P90 1000VA User Guide
Xtreme Power Conversion P90 1000VA Online Manual

Text of Xtreme Power Conversion P90 1000VA User Guide:

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 42 Uninterrupble Power Supply Baery Replacement If your baery box is not installed with baeries, please follow proper procedure to put baeries inside of unit. NOTE: MAKE SURE THAT THE BATTERY BOX IS DISCONNECTED FROM THE UPS BEFORE PERFORMING THE FOLLOW- ING SEQUENCE OF OPERATIONS. P90-BP48 Step 1 : Open the package and place the baery box on a horizontal plane. Step 2: Remove the removable front panel part by pulling it from the lower extremity Step 3: Remove the xed part of the front panel by removing the 2 screw present. S

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 30 Uninterrupble Power Supply Troubleshoong If the UPS does not operate correctly, please use the table below to troubleshoot the problems. Symptom Possible cause Remedy No indicaon and alarm even though the ulity is normal. The AC input power is not con- nected well. Check that the input power cord is rmly connected to the ulity. The AC input is connected to the UPS output. Plug the AC input power cord into the AC input ulity correctly. The icon and the warning code are ashing on LCD dis

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 31 Uninterrupble Power Supply Fault code is shown as 01, 02, 03, 04, 11, 12, 13 and 41 on LCD dis- play and alarm is sounding connu- ously. A UPS internal fault has occurred. There are two possible results: 1. The load is sll supplied, but directly by AC ulity via bypass. 2. The load is no longer supplied with power. Contact your dealer for support. Baery backup me is shorter than expected. Baeries are not fully charged. Charge the baeries for at least 5 hours and then re-check capacity. If the problem sll exists, contact your dealer for suppor

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 2 Uninterrupble Power Supply Table of Contents Introducon.................................................................................................6 Product Descripon.....................................................................................6 Double Conversion Online Technology............................................................................................6 Diagnosc Tests......................................................................................

  • Xtreme Power Conversion Corporaon P90 User’s Manual Page 10 Uninterrupble Power Supply Emergency Power O (EPO) Port A customer supplied switch located remotely can be used to close the EPO connecon and allows the UPS output receptacles to be switched o. Since the EPO shuts down the equipment immediately, orderly shutdown proce- dures are not followed by any power

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 34 Uninterrupble Power Supply Obtaining Service If the UPS requires Service: 1. Use the TROUBLESHOOTING secon in this manual to eliminate obvious causes. 2. Verify there are no circuit breakers tripped. 3. Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the problem, call Xtreme Power Conversion Corp Technical Support at 800.582.4524. Technical support inquiries can also be made at [email protected]. Please have the following informaon available BEFORE calling the Technical Support Departmen

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 7 Uninterrupble Power Supply Diagnosc Tests When the UPS is started, a diagnosc test is automacally executed, checking the electronics and baeries, report- ing any problems on the LCD display. System Conguraon The UPS device and the internal baeries make up the system. Depending on the site and load require- ments of the installaon, certain addional opons are available for the soluon. Planning a UPS

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 3 Uninterrupble Power Supply Obtaining Service.......................................................................................34 Xtreme Power Conversion Limited Warranty...............................................35 Xtreme Power Conversion Load Protecon Policy.......................................36 Appendix A: P90-BP48 & P90-BP72 User Guide...........................................39 Important Safety Instrucons................................................................................................

  • Xtreme Power Conversion Corporaon P90 User’s Manual Page 32 Uninterrupble Power Supply Storage And Maintenance Storage Before storing, charge the UPS at least 5 hours. Store the UPS covered and upright in a cool, dry locaon. During storage, recharge the baery in accordance with the following table: Storage Temperature Recharge Frequency Charging Duraon -25°C - 40°C E

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 12 Uninterrupble Power Supply UPS Installaon Installaon and wiring must be performed in accordance with the local electrical laws and regulaons, and per- formed by appropriate personnel. For safety consideraons, the UPS is shipped from the factory with baery wires disconnected. Before installing the UPS, please follow these steps to connect the baery wires. Connecng the baeries Step 1 Step 2 Step 3 Remove the front panel Connect the baery wires Place the fr

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 14 Uninterrupble Power Supply Step 1 Use 4 screws to mount right and le rail sliders in front of rack. Step 2 Use 4 screws to mount right and le rail sliders in back of rack. Step 3 Place the nuts in the proper locaon in the rack based upon height of UPS.

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 5 Uninterrupble Power Supply For addional safety instrucons, please use the Safety Manual as a reference. Special Symbols The following symbols used on the UPS warn you of precauons: RISK OF ELECTRIC SHOCK - Please observe the warning that a risk of electric shock is present CAUTION: REFER TO OPERATOR’S MANUAL - Refer to the operator’s manual for addional informaon, such as important operang and maintenance instrucons. SAFE GROUNDING TERMINAL - Indicates primary safe ground LOAD ON/OFF – Pressing the buon turns on/o the output re

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 26 Uninterrupble Power Supply 08: Programmable Outlets Seng Interface Seng 0-999: seng the backup me limits in minutes from 0-999 for programmable outlets connected to non-crit- ical devices when operang in baery mode. 09: LCD Display Direcon Seng Interface Seng RAC: the LCD display is horizontal. TOE: the LCD display is vercal. 10: Acceptable Input Voltage Range Seng Interface Seng Choose the following Acceptable input voltage range: 55/150 alternang ashing: acceptable input voltage range

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 40 Uninterrupble Power Supply Rear Panel View 1. DC connector : connects to either UPS or 2nd baery box 2. DC breaker: Baery over-current protecon breaker 3. External baery numbers detecon port: detects the numbers of connected baeries. Installaon and Setup with UPS Unpacking & Inspecon 1. Remove the baery box from the packing. Note: The baery box is very heavy, be cauous when unpacking and liing the unit to avoid injury. 2. Check the inside package • Baery box unit • Quick guide • Baery connecon cabl

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 9 Uninterrupble Power Supply Communicaon Connecons To allow for unaended UPS shutdown/start-up and status monitoring, connect one end of the communicaon cable to the USB/RS232 port and the other to the communicaons port on your PC or server. With the monitoring soware installed, the UPS can be scheduled for shutdown/start-up and monitoring of the UPS status through the PC or server. RS232 Communicaons The RS-232 interface uses a 9-pin female D-sub connector. Informaon provided includes data about ulity, load and the UPS. The int

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 21 Uninterrupble Power Supply Display Funcon Backup me informaon Indicates the backup me in pie chart. Indicates the backup me in numbers. H: hours, M: minutes Warning & Fault informaon Indicates that the warning and fault occurs. Indicates the warning fault codes, and the codes are listed in details in this manual. Seng Operaon Indicates the seng operaon. Input / Output & Baery informaon Indicates the output/input voltage, output/input frequency or baery volt- age. V: output voltage, Hz: frequency Load informaon Indicates the

  • Xtreme Power Conversion Corporaon P90 User’s Manual Page 36 Uninterrupble Power Supply Xtreme Power Conversion Load Protecon Policy THIS POLICY IS NOT A WARRANTY. REFER TO THE XPC CORPORATION, INC. LIMITED WARRANTY FOR INFORMATION CONCERNING THE WARRANTY FOR YOUR XPC PRODUCT. THE LIMITATIONS AND CONDITIONS CONTAINED IN THIS POLICY DO NOT AFFECT

  • Xtreme Power Conversion Corporaon P90 User’s Manual Page 17 Uninterrupble Power Supply UPS Input Connecon Connect the UPS to an approved electrical input source consistent with the input power cord connecon provided with the UPS. Do not replace the power cord or use a substute. Avoid using extension cords when connecng AC input to any UPS. UP

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 48 Uninterrupble Power Supply Note: The cable connecon from the external baery connector to PCB is already present inside the baery box. All the other cable connecons should be made in accordance with the above wiring diagram. Storage & Maintenance The unit contains no user-serviceable parts. If the baery service life (3~5 years at 25°C ambient temperature) has been exceeded, the baeries must be replaced. In this case, please contact your dealer. Be sure to deliver the spent baery to a recycling facility or ship it to your dealer in the replacement baery packing mat

  • Xtreme Power Conversion P90 1000VA, Xtreme Power Conversion Corporaon P90 User’s Manual Page 43 Uninterrupble Power Supply Note: To install the second string of baeries, repeat the same procedure on the baery hold down brackets on the right side of the baery box. Step 6: Now, it is possible to put all baeries inside the unit by following the below picture (the following drawing are indicates the wire fastener posions for the correct baery placement). Note: To install the second string of baeries, repeat the same procedure on the right side of baery box. Step 7: Connect all baeries following the w

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Weslo WLTL11310.0 Operation & user’s manual weslo/wltl11310-0-K4L.pdf 01 Aug 2023 16 0.9 Mb
2 Hotpoint Ariston ARXXF 125 User manual manual hotpoint-ariston/arxxf-125-W4Y.pdf 29 Apr 2023 48
3 Nevir NVR-466DU Instruction manual nevir/nvr-466du-2CT.pdf 12 Aug 2023 12
4 Nilfisk-ALTO ATTIX 30 H Quick start manual nilfisk-alto/attix-30-h-68P.pdf 01 Aug 2022 28
5 Philips HR2636 Manual  philips/hr2636-Y9G.pdf 21 Mar 2024 13
6 Audiovox FD-250 Owner's manual audiovox/fd-250-629.pdf 22 Oct 2022 8 0.25 Mb

Similar Resources:

  • OPTI-UPS

    Line Interactive UPS Series PS1000B-RM

    (3 pages)
    21.PS800B / PS1000B / PS1500B / PS2200B / PS3000BFront PanelThe PSB Series are the only line interactive pure sinewave UPS designed to meet everyone's needs. Our full line covers every possible application demand. There are five tower models, from PS800B to PS3000B, and four rack-mount models, from PS1000B-RM to PS3000B-RM.Every PSB model utilizes digit …
  • Panduit

    UPS003LSM

    (8 pages)
    UPS003LSM PA27224A01 Rev: 02 3-2014 UNINTERRUPTIBLE POWER SUPPLY LOAD SENSE MODULE OPERATION MANUAL © Panduit Corp. 2014 Original Instructions TO REDUCE THE RISK OF INJURY, USER MUST READ INSTRUCTION MANUAL Email: [email protected] EU Website: www.panduit.com/emea EU Email: emeatoolservicecenter @panduit.com www.panduit.com Technic …
  • Tripp Lite

    SmartPro SMART2200CRMXL

    (6 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: SMART2200CRMXLSmartPro 2.2kVA Line Interactive Sine Wave UPS, 1900W, Extended-run, SNMPWEBCARD options, 4URack/Tower, USB, Serial, EPO, 120V Highlights2.2kVA / 2200VA / 1900W line interactive UPS, 0.86 power factor120V output, Corrects brown …
  • Gematronic

    SCE-650

    (14 pages)
    GAMATRONIC ELECTRONIC INDUSTRIES LTD. 17 Hartom St., P.O.B. 45029, Jerusalem 91450, Israel Tel: 972-2-588-8222 Fax: 972-2-582-8875 Email: [email protected] Website: www.gamatronic.com SMART COMPACT UPS User’s Manual 650 VA 750 VA 1000 VA 1500 VA Release 1.8, November 2013 2MUXSMART-E …
  • Powercom

    425A/AP

    (8 pages)
    U P S Line-Interactive 425VA-1000VA IMD-1000AP, IMD-1000A, IMP-1000AP, IMP-1000A IMD-825AP, IMD-825A, IMP-825AP, IMP-825A IMD-625AP, IMD-625A, IMP-625AP, IMP-625A IMD-525AP, IMD-525A, IMP-525AP, IMP-525A IMD-425AP, IMD-425A, IMP-425AP, IMP-425A ■USER MANUAL■ …
  • Powertronix

    PTX2-A3

    (21 pages)
    Service Manual PTX2-A3 UPS 6kVA~10kVA 220VAC …