YMGI WMMS-09EW-V2B, LITERATURE: LIT-WMMS-(59) (2)-EW-DC IVTR-USER MANUAL-20130813 Literature Part No: LIT-WMMS-(59) (2)-EW-DC IVTR-USER MANUAL-20130813 For WMMS Series of Product Single Zone (Cooling, Heat Pump) Subject to Continuous Engineering Improvement without Prior Notice. YMGI is the Trademark and Property of YMGI Group. Copyright of YMGI Group. This product is designed and manufactured free from defects in material and workmanship under the normal use and maintenance. Installation, operation, maintenance and service shall follow professional practices for regular cooling and heating equip
YMGI WMMS-09EW-V2B, MUST READ CONTENTS P1 OF 40 All Units Shall Be Installed by Experienced or Licensed Contractor Or Technician. Read Manuals before Installation. YMGI Group Shall NOT Take Any Responsibilities for Any Damage or Loss Due to Do-It-Yourself(DIY) self-installation and other Improper Installation or Operation or Natural Disaster. Connect All Wiring Securely. Loose Wire or Other Bad Contact May Cause Arc or Overheating and Fire Hazard. Following NEC, State and Local Codes and Installation Instructions of All Units, Otherwise Unit Warranty Will Be Void and Serious Damage To People Or Proper
YMGI WMMS-09EW-V2B, MUST READ MUST READ LIMITED PRODUCT WARRANTY REGISTRATION CARD LIMITED PRODUCT WARRANTY REGISTRATION CARD / FORM YMGI to Fill Top Portion, at Shipping, and Keep Copy A; Center Copy B for Installer to Fill and Mail back to YMGI; Bottom Copy C for Customer to Fill and Keep Installation Finished and Unit Works Successfully. Print Name of Installation HVAC Technician: Signature: Date and time: Installation Finished and Unit Works Successfully. Print Name of Owner: Signature: Date and time: 1) Are you the only one to install whole system? If not, % of in
MUST READ MUST READ P5 OF 40 P6 OF 40 Dear Customer(s)/End User(s)/Unit Purchaser(s)/Installer(s)/Contractor(s) Thanks for choosing YMGI products. The YMGI equipment you purchased is either a split-type or a self-contained cooling/heating system which requires an installer's license, certification, knowledge, experience, carefulness and details for a succ
YMGI WMMS-09EW-V2B, 1) The YMGI Limited Product Warranty Policy, details the eligibilities, coverage's and other explanations of the warranty terms between YMGI group and the unit owner. 2) The YMGI Limited Product Warranty Policy and the Warranty Registration Card/Form are either included inside the user's manual and/or installation instruction manual, or come separately in the unit packaging box/envelope. If for any reason they are not included with your shipment, contact our sales or customer service to request a copy (electronic or printed), p
F. Charges for your return: 1)A restocking charge of 25% creditable invoice value. 2)All return shipping fees. 3)Additional fees will be charged, if products are found to be damaged, missing or used. 4)YMGI will notify the distributor of the charges only after the inspection and assessment of the returned products has been completed. Attention: 1) Returned products must be shipped within 7
YMGI WMMS-09EW-V2B, BRIEF UNIT INFO MUST READ P11 OF 40 P12 OF 40 IMPORTANT NOTES These precautions are essential and must be strictly observed. DO NOT pull on the power cord or refrigeration lines. Install them in a secured position. A line set plastic cover is recommended. DO NOT install the unit in places where there is exposure to flammable materials or gas leakage. DO NOT use wire or circuit breakers that do not meet electrical safety standards. Several circuits cannot be connected to one breaker. DO NOT wire or open the unit while it is running. Make sure to shut off all circuits prior to inspecting or servicing the unit. DO NOT install unit in
YMGI WMMS-09EW-V2B, BRIEF UNIT INFO BRIEF UNIT INFO P13 OF 40 P14 OF 40 TECHNICAL SPECIFICATIONS Indoor Unit-Wall Mount Type Performance Data WMMS-09EW-V2B(59) (2) WMMS-12EW-V2B(59) (2) WMMS-18EW-V2B(59) (2) Fan Motor Speed (RPM) (SH/H/M/L) 1150/1050/900/750 1250/1050/950/800 1350/1200/1050/900 Item 8400 9350 7580 Nominal heating capacity (ID 70/60 OD 47/43F) Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD17/15F) Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD 5F) 10800 12850 8680 16200 24850 14280 Total Capacity (Btu/h) (High/ Standard/Low) AC:10480/8850/4235 HP:10980/9350/3000 AC:13880/1
YMGI WMMS-09EW-V2B, BRIEF UNIT INFO BRIEF UNIT INFO P15 OF 40 P16 OF 40 WMMS-18EW-V2B(59) (2) 7.85" 7.85" 2.75" 11.2" 32.7" 7.9" UNIT VIEWS,DIMENSIONS & MOUNING BRACKET CLEARANCE YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! WMMS-09EW-V2B(59) (2) / WMMS-12EW-V2B(59) (2) 9.8" 30.5" 7.5" 2.75" 7.85" 7.85" UNIT VIEWS,DIMENSIONS & MOUNING BRACKET CLEARANCE
YMGI WMMS-09EW-V2B, BRIEF UNIT INFO BRIEF UNIT INFO P17 OF 40 P18 OF 40 CONTROLLER FUNCTION 1) Fan motor runs under low speed, swing runs by setting status. 2) Indoor unit will run under the original status when outdoor unit malfunction or stop to run protection, malfunction displays. O The temperature setting range is 61-86 F under the mode. Temperature Parameter * Indoor ambient temperature (Tamb.) * Indoor copper tube temperature (Ttube) * Evaporator inlet pipe temperature (Tinlet pipe) * Evaporator outlet pipe temperature (Toutlet pipe) Cooling Mode 1) Fan motor
YMGI WMMS-09EW-V2B, INSTALLER'S INSTRUCTION BRIEF UNIT INFO P19 OF 40 P20 OF 40 Cold Plasm Function Remote control the cold plasm function to ON and turn on the cold plasm when the fan motor is ON; remote control the cold plasm to OFF or turn off the cold plasm when the dan motor is OFF. Unit Display Basic Display 1) When the unit is energized, the display symbol display, then only power lamp is light. 2) When use remote control to turn on the unit, the running LED is light, and the current setting running mode lamp displayed at the same time. COOLING: running lamp and cooling lamp are light; HEATING:
INSTALLER'S INSTRUCTION INSTALLER'S INSTRUCTION P22 OF 40P21 OF 40 SYSTEM LAYOUT & INSTALLATION CLEARANCE Indoor unit A Indoor unit B OVER 20" OVER 10" OVER 10" OVER 8" OVER 10" OVER 2" OVER 4" OVER 4" OVER 80" CLEARANCE REQUIRED AROUND UNITS-DUAL ZONE-2 YMGI, Engineered Comfort Products for A Sustainable
YMGI WMMS-09EW-V2B, INSTALLER'S INSTRUCTION INSTALLER'S INSTRUCTION P24 OF 40P23 OF 40 SYSTEM LAYOUT & INSTALLATION CLEARANCE Indoor unit A Indoor unit B Indoor unit C Indoor unit D OVER 20" OVER 10" OVER 10" OVER 8" OVER 10" CLEARANCE REQUIRED AROUND UNITS-QUAD ZONE OVER 2" OVER 4" OVER 4" OVER 80" YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! SYSTEM LAYOUT & INSTALLATION CLEARANCE CLEARANCE REQUIRED AROUND UNITS-TRIPLE ZONE Indoor unit A Indoor unit B Indoor unit C OVER
YMGI WMMS-09EW-V2B, INSTALLER'S INSTRUCTION INSTALLER'S INSTRUCTION P25 OF 40 P26 OF 40 HEIGHT LIMITS OF INDOOR AND OUTDOOR UNITS * Either the indoor unit or the outdoor unit can be higher, but the height difference must comply the stated r equirements. * Try to reduce the bending of the piping line as much as possible so as to avoid possible negative impacts upon the performances of the units. Indoor unit Outdoor unit Lift * Make P-trap if elevation drop difference is more than 25", as illustrated below. Indoor unit Outdoor unit Drop P-Trap 18 In Refrigerant Pipe Min/Max. Length, Rise and Drop Height 1,000 Btu/h 09-12 18-24 30-36 Max. Length (F
INSTALLER'S INSTRUCTION INSTALLER'S INSTRUCTION P28 OF 40 To drain the condensate easily, the drain hose should be inclined downward (pitched towards drain direction 1/4" per foot). Figures below from the 2nd to 5th show some incorrect practices. Drain hose may be extended using the hose coming with the installation list. STUFF AND SEAL THE HOLE FOR COPPER LINE SE
YMGI WMMS-09EW-V2B, UNIT MAINTENANCE & SERVICE GUIDE INSTALLER'S INSTRUCTION P29 OF 40 P30 OF 40 Heat insulator (indoor unit) Interconnection cable Sealing tape Ribbon vinyl Heat insulator (connection pipe) Sealing tape Join the tubes insulators and refrigerating connection so as there is no space. Interconnection cable Drain hoseDrain hose PiPe PiPe Clamp Pipe Interconnection cable RIibbon viyl Wall Out Outdoor screw Putty Overlap nylon ribbon or similar wrap. Pipe of indoor unit Connecting pipe Seal Copper Line Set/Wire Cable/Drain Hose Line Combination * Run cables along with the refrigerating copper line sets and secure them with tapes at 6 feet
YMGI WMMS-09EW-V2B, UNIT MAINTENANCE & SERVICE GUIDE UNIT MAINTENANCE & SERVICE GUIDE P31 OF 40 P32 OF 40 EXPLOSIVE VIEW AND SPARE PARTS LIST COMPONENTS AND PARTS LIST 1-WMMS-09EW-V2B(59) (2) Wall-mounting frame 1 Rear case 1 Evaporator assy 1 Cross flow fan 1 Ring of bearing 1 / / Drainage pipe 1 Water tray 1 Swing louver 12 Swing linkage 1 1 1 Swing linkage 2 Front case 1 Front panel 1 Decorate piece 1 Remote control YT1F 1 Filter 2 Receiver board D5K3 1 Screw cover 3 Guide louver 1 1 1 1 Guide louver 2 1 Motor MP
YMGI WMMS-09EW-V2B, UNIT MAINTENANCE & SERVICE GUIDE UNIT MAINTENANCE & SERVICE GUIDE P33 OF 40 P34 OF 40 EXPLOSIVE VIEW AND SPARE PARTS LIST COMPONENTS AND PARTS LIST 2-WMMS-12EW-V2B(59) (2) 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 32 33 34 35 36 37 No Description Part Code Qty Wall-mounting frame 01252384 1 Rear case 222020503 1 Evaporator assy 01002250 1 Cross flow fan 10352005 1 Ring of bearing 76712015 1 \ \ \ Drainage pipe 0523001401 1 Water tray 201820306 1 Swing louver 105120413 12 Swing linkage 105824397 1 Front case 200022958 1 Screw cover 242520072 3 Filter 11122440 2 Remote control YT1F 30510049 1 Decorate piece 68012019 1 Receiver board 30545042
YMGI WMMS-09EW-V2B, UNIT MAINTENANCE & SERVICE GUIDE UNIT MAINTENANCE & SERVICE GUIDE P35 OF 40 P36 OF 40 EXPLOSIVE VIEW AND SPARE PARTS LIST COMPONENTS AND PARTS LIST 3-WMMS-18EW-V2B(59) (2) The above data are subject to change without prior notice. 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 32 33 34 35 36 37 38 39 No Description Part Code Qty Wall-mounting frame 01252004 1 Rear case 22202329 1 Fan bearing 76512203 1 Screw cover 24252015 3 Swing louverb 105120472 11 Swing link 1 10582057 1 Swing link 2 10582058 1 Water tray 20182057 1 Guide louver(up) 10512085 1 Guide louver(down) 10512086 1 Cross flow fan 10352022 1 Evaporator assy 01002
YMGI WMMS-09EW-V2B, WARRANTY & SUPPORT UNIT MAINTENANCE & SERVICE GUIDE P37 OF 40 P38 OF 40 DISASSEMBLY PROCEDURE OPERATING PROCEDURES / PHOTOS Disassemble Cover of Electric Box Loosen the three clasps, and pull upward to remove the cover of the electric box. Disassemble Electric Box Remove the grounding wire of the evaporator. Take out the pipe temp. sensor. Unplug the plugging connector of the indoor motor at the electric box, use screwdriver to unscrew the screw fixing the electric box, loose the clasp and remove the electric box. Screw off one screw which fix the connection board clamp.
YMGI WMMS-09EW-V2B, WARRANTY & SUPPORT WARRANTY & SUPPORT P39 OF 40 SERVICE/MAINTENANCE LOG Put down whatever questions you have or problems you have seen as a unit history: No. Date Service/Maintenance Conducted Person/Phone USER NOTES Put down whatever questions you have or problems you have seen as a unit history: No. Date Questions or Problems Remarks USER NOTES AND SERVICE LOG P40 OF 40 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! WARRANTY AND TECH. SUPPORT YMGI warrants to the purchaser/owner(s) that YMGI products be free from defects in material an
YMGI WMMS-21CH Air Conditioner Installer's instruction & user's manual
WMMS-21CH |
YMGI WMMS-09EW-V2B(59)2 Air Conditioner Installer's instruction & user's manual
WMMS-09EW-V2B(59)2 |
YMGI LIT-WMMS-(56)-DC IVTR Air Conditioner Installation instructions manual
LIT-WMMS-(56)-DC IVTR |
YMGI WMMS-21CH Air Conditioner Installer's instruction & user's manual
WMMS-21CH |
YMGI MINI SPLIT TYPE Air Conditioner Operation & user’s manual
MINI SPLIT TYPE |
YMGI WMMS-09EW-V2B(59)4 Air Conditioner Installer's instruction & user's manual
WMMS-09EW-V2B(59)4 |
Argo AS1S** Series Air Conditioner Installation instructions manual
AS1S** Series |
Heat Controller VMC09SB-1 Service Air Conditioner Owner's manual
VMC09SB-1 Service |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Martin Audio | C4.8T | Operation & user’s manual | martin-audio/c4-8t-599.pdf | 08 Sep 2022 | 10 | |
2 | Quantum | PX500 | Release note | quantum/px500-R5U.pdf | 21 Sep 2022 | 8 | 0.23 Mb |
3 | Progear Fitness | 3001A.3-031417 | Manual | progear-fitness/3001a3-031417-1IS.pdf | 25 May 2023 | 23 | |
4 | Comcast | Xfinity | Manual | comcast/xfinity-K8Z.pdf | 09 Nov 2022 | 1 | |
5 | Universal Remote Control | R6 | Owner's manual | universal-remote-control/r6-H66.pdf | 13 Jul 2022 | 44 | 0.72 Mb |
6 | Wind Crest | WSL Series | Install quick specs | wind-crest/wsl-series-521.pdf | 17 Apr 2023 | 2 | 0.13 Mb |
Friedrich
SPLIT TYPEROOM AIR CONDITIONERWALL MOUNTEDtypeERROR CONTENTS . . . . . . . . . . . . . . . . . .ModelsIndoor unit Outdoor unitMW18Y3F MR18Y3FCONTENTSSPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . 1OUTLINE AND DIMENSIONS . . . . . . . . . . . 2STANDARD ACCESSORIES . . . . . . . . . . . 17REFRIGERANT SYSTEM DIAGRAM . . . . . 3CIRCUIT D …
MR18Y3F(19 pages) |
LG
TYPE PORTABLE AIR CONDITIONERMODEL LP1414GXROWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating your air conditioner and retain it for future reference. www.lgappliances.comFor service questions, contact LG at 1-800-243-0000.For sales in …
LP2525GXR(30 pages) |
Kenmore
Owner's ManualManual del Propietario®ROOM AIR CONDITIONERACONDICIONADOR DE AIRE DE VENTANAModel, Modelo 580. 72189Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.www.sears.comP/N: 3828A20133V
…
580.72189(25 pages) |
LG
OWNER’S MANUALAIR CONDITIONER Please read this manual carefully before operatingyour set and retain it for future reference.www.lg.comTYPE : WALL MOUNTEDP/NO : MFL67658916ENGLISH FRANCAISPORTUGUESE
…
MFL67658916(49 pages) |
Carrier
HEATING L COOLlNG130GTK,HL/ckageSAFETY CONSIDERATIONSInstalling, starting-up and servicing air conditioningequipment can be hazardous due to system pressures,electrical components and equipment location,Only trained, qualified installers and service techni-cians should install, start up and service this equipment.When working on air conditioning equipment, o …
30GT(4 pages) |
Argo
EGIFDEPGRAW22ALAW28ALAW38ALOPERATING INSTRUCTIONS • ISTRUZIONI D’USONOTICE D’UTILISATION • BEDIENUNGSANLEITUNGINSTRUCCIONES DE USO • MANUAL DE INSTRUÇÕESΟΟ∆∆ΗΗΛΛΙΙΕΕΣΣ ΧΧΡΡΗΗΣΣΕΕΩΩΣΣSplit air conditioner system • Condizionatore d’aria split systemClimatiseurs split • Split-klimagerätAcondicionador de aire de …
AW22AL(12 pages) |
Fisher Labs Metal Detector F4#8D6Y57 F4: Fisher Labs Metal Detector Owner Documentation F4, 10 |
MIA Scales KW 7015MIA Scales KW 7015 Instruction manual KW 7015, 18 |
BCP Fan SKY3865BCP SKY3865 Fan Instruction manual SKY3865, 12 |
TerraTec Sound Card DMX 6Fire USBSound Card #622795 DMX 6Fire USB, 8 |
Vivitar Digital Camera ViviCam T026#7X878O: ViviCam T026 Digital Camera Operation & user’s manual ViviCam T026, 66 |
Valentine Fryer BB 7#N36EZ4: BB 7 Fryer Instructions BB 7, 5 |
Gator Security Camera G50CCSecurity Camera Operation & user’s manual (Gator G50CC) G50CC, 2 |
Petra Coffee Maker 242800Petra 242800 Guide (Doc Type: Coffee Maker Manual ) 242800, 40 |
MIMAKI Printer UJV500-160MIMAKI Printer Operation manual (File: mimaki-ujv500-160-printer-208, Tuesday 07-11-2023) UJV500-160, 208 |
Tornado Cleaning Equipment BR 47/35 ESCTornado Cleaning Equipment Manual (File: tornado-br-4735-esc-manual-56, Tue 11.2023) BR 47/35 ESC, 56 |
Atwood Water Heater MPD 93756Water Heater #6J9132 MPD 93756, 7 |
Wen Dust Collector 3401Dust Collector PDF Manual 3401, 12 |