  • This product is designed and manufactured free from defects in material and workmanship under the normal use and maintenance. Installation, operation, maintenance and service shall follow or Local Codes and related manuals from us. Otherwise, damage to equipment or property even injury to people may occur. Installer: Read this instruction manual before installation. Remember to complete

  • YMGI WMMS-12EC-V2B, CONTENTS MUST READ-1 All Units Shall Be Installed by Experienced or Licensed Contractor Or Technician. Read Manuals before Installation. YMGI Group Shall NOT Take Any Responsibilities for Any Damage or Loss Due to Do-It-Yourself(DIY) self-installation and other Improper Installation or Operation or Natural Disaster. Connect All Wiring Securely. Loose Wire or Other Bad Contact May Cause Arc or Overheating and Fire Hazard. Following NEC, State and Local Codes and Installation Instructions of All Units, Otherwise Unit Warranty Will Be Void and Serious Damage To People Or Property May Be Caused. Don

  • YMGI WMMS-12EC-V2B, MUST READ-1 MUST READ-1 P4 OF 44P3 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! 1. Be sure to hire only one certified, licensed HVAC Company to complete 100% of the installation so that all details of the installation are clear, complete and well taken care of. 2. Be sure to have ONLY the licensed HVAC professional perform all parts of the installation. Factory Warranty will be lost if any portion of

  • YMGI WMMS-12EC-V2B, WARRANTY POLICIES AND REGISTRATION CARD/FORM WARRANTY POLICIES AND REGISTRATION CARD/FORM P5 OF 44 P6 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! LIMITED PRODUCT WARRANTY POLICIES The YMGI products are designed and manufactured free from defects in workmanship, and materials for normal use. However, for any reason, including many handlings and occasions between the YMGI factories/warehouses and where you receive the products, the unit doesn't work, YMGI Group will help to remedy the occurrence in the following warranting wa

  • WARRANTY POLICIES AND REGISTRATION CARD/FORM BRIEF UNIT INFO P7 OF 44 P8 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! Apartments Office Buildings Homes Ceiling Mount Cassette Systems are designed for high performance, easy installation and service. Each syste

  • YMGI WMMS-12EC-V2B, BRIEF UNIT INFO BRIEF UNIT INFO P9 OF 44 P10 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! UNIT SPECIFICATIONS Items Power Supply Cooling Capacity (Btu/h) Heating Capacity (Btu/h) SEER HSPF Duhumidifying Capacity Air Flow (CFM) Air-throw (Ft.) External Static Pressure Sound Level Fan Motor Fan Wheel Swing/Step Motor Input Power of Ele. Heater Electrical Protection Fuse Evaporator Coil Copp

  • YMGI WMMS-12EC-V2B, INSTALLER'S INSTRUCTION INSTALLER'S INSTRUCTION P12 OF 44P11 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! INSTALLATION NOTES Location Noise * The air conditioner must be firmly installed and 3~ 4 liability checks must be done every year. * Avoid place within easy reach of young children. * Avoid other heat sources or direct sun light. * Install indoor unit away from TV set or radio. * Avoid where flammable gas is likely to leak. * At salty coastal areas or special areas such as the vicinity of a sulphurous hot spring, please contact dealer befor

  • YMGI WMMS-12EC-V2B, INSTALLER'S INSTRUCTION INSTALLER'S INSTRUCTION P14 OF 44P13 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! INDOOR UNIT INSTALLATION LOCATION 1) Do not place object near the air outlet so that conditioned air can reach the whole room. 2) Be sure to install the indoor unit firmly and horizontly. 3) Select a place that can support 4 times the weight of the indoor unit and will not increase noise and vibration. 4) Select a place easy to drain water and connect with the outdoor unit

  • YMGI WMMS-12EC-V2B, INSTALLER'S INSTRUCTION INSTALLER'S INSTRUCTION P16 OF 44P15 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! INDOOR UNIT INSTALLATION BOLTING THE GRILLE ASSEMBLY TO THE BODY Install the grille assembly to the body with the four bolts, spring washers, and washers. Wireless unit connection wire wiring (1) part A detail. Connect the connector in accordance with the (2) Then clamp the lead wir

  • YMGI WMMS-12EC-V2B, INSTALLER'S INSTRUCTION INSTALLER'S INSTRUCTION P18 OF 44P17 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! INDOOR UNIT INSTALLATION Tightening torque table: Pipe size Φ6.25 (1/4") Φ9.52 (3/8") Tightening torque (N·m) 15~20 30~40 Power supply and wiring requirement AC 208/230V. If voltage is over, may cause the parts of electric equipment to become damaged. If the voltage is too low, this may cause the compressor to shake thus causing damage to the cooli

  • INSTALLER'S INSTRUCTION INSTALLER'S INSTRUCTION P20 OF 44P19 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! HOW TO CONNECT WIRING TO THE TERMINALS A. For solid core wiring (or F-cable) (1) Cut the wire end with wire cutters, then strip

  • YMGI WMMS-12EC-V2B, INSTALLER'S INSTRUCTION INSTALLER'S INSTRUCTION SAFETY CAUTIONS READ THE FOLLOWING CAREFULLY BEFORE OPERATION WARNING Avoid direct air flow to your body and avoid excessive heating or cooling that may make you feel uncomfortable and do harm to your health. Check whether the installed stand is still firm enough after the unit has operated for an extended time. If a worn-out stand is left unfixed, the unit may fall and damage property or harm people. Do not remove protection grill nets from the outdoor unit. Do not stand on the outdoor unit or put anything on it. Unit may fall causing harm to self or others. Do not put hands or insert anythin

  • YMGI WMMS-12EC-V2B, UNIT OPERATION UNIT OPERATION P24 OF 44P23 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! "LIGHT" BUTTON: This allows you to turn the indoor unit display light on and off. If the light emitted by the display is bothersome simply press the LIGHT button on the remote and the display will turn off. To turn the display back on simply press the light button once more. "FAN" BUTTON: By pressing this button you can select from fan sp

  • YMGI WMMS-12EC-V2B, UNIT OPERATION UNIT OPERATION P26 OF 44P25 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! SYMBOL DISPLAY When power is first applied to the unit but the power has not been turned on by the remote control, then a red power light only is displayed. When the unit has been powered on by the remote control then the running LED is lit and the current running mode symbol is displayed at the same time. COOLING: Running symbol and cooling symbol are lit. HEATING: Running lamp and heating symbol are lit. DRY:

  • YMGI WMMS-12EC-V2B, UNIT MAINTENANCE & SERVICE GUIDE P28 OF 44P27 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! Notice 1) Preparation before service Step 1: Firstly, confirm the model of the inverter A/C which needs repairing, and then find out model of main parts that can be damaged easily and the material encode, especially the controller of outdoor unit; Step 2: Based on the malfunction reflected by user, determine the parts that will need to be replaced, and bring tools with

  • UNIT MAINTENANCE & SERVICE GUIDE UNIT MAINTENANCE & SERVICE GUIDE P30 OF 44P29 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! TROUBLE SHOOTING Dust from the units Discharged air smells Starting operation after not using for a longtime Duri

  • YMGI WMMS-12EC-V2B, UNIT MAINTENANCE & SERVICE GUIDE UNIT MAINTENANCE & SERVICE GUIDE P32 OF 44P31 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! TROUBLE SHOOTING When the unit is controlled by wire controller, error or protection codes are as follows: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Compressor high pressure protection unit stop Indoor unit anti-freezing protection Low-pressure protection unit stop Air exhaust protection unit stop Over current protection unit stop Communication malfunction unit stop Unit modes conflict Jumper malfunc

  • YMGI WMMS-12EC-V2B, UNIT MAINTENANCE & SERVICE GUIDE UNIT MAINTENANCE & SERVICE GUIDE P34 OF 44P33 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! TROUBLESHOOTING When there's malfunction or protection, the display screen of indoor unit or LED will display corresponding code and LED on main board of outdoor unit will also have warnings. Please refer to the function parts as before for details. When protection or malfunction has been eliminated, the display will resume normal status. Analysis or disposal for some display malfunction

  • YMGI WMMS-12EC-V2B, UNIT MAINTENANCE & SERVICE GUIDE UNIT MAINTENANCE & SERVICE GUIDE P36 OF 44P35 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! How to Clean the Air intake 1) Open the air intake grille. 2) Remove the air filters. 3) Open the grille at a 45 Degree angle and then lift, it up to take away. See step 1 of "How to Clean the Air Filter" See step 2 of "How to Clean the Air Filter" 4) Wash with water. When the air intake grille is very dirty, use soft brush and neutral detergent. Shake off water and air dry in a shady p

  • YMGI WMMS-12EC-V2B, MUST READ-2 MUST READ-2 QUESTIONS ABOUT SELF-INSTALLATION VS HIRING LICENSED HVAC TECHNICIANS CUSTOMER AND TECHNICIAN MUST READ 1) You understand all that is written hereafter in this and other documents that we publish. 2) You will follow what is written hereafter in this and other documents that we publish. 3) You will be bound by and completely follow all policies, guidelines, instructions, warnings, attentions and other materials, as published by YMGI Group, its subsidiaries or sister companies, in writing. 4) Only a successful installation, fully (100%) conducted by a qualified HVAC technician(s), as detailed in the checkli

  • MUST READ-2 MUST READ-2 F. Charges for your return: 1)A restocking charge of 25% creditable invoice value. 2)All return shipping fees. 3)Additional fees will be charged, if products are found to be damaged, missing or used. 4)YMGI will notify the distributor of the charges only after the inspection and assessment of the returned products has been completed. Attention:

  • YMGI WMMS-12EC-V2B, MUST READ-2 P42 OF 44P41 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! Standard factory warranty does not cover the cost of materials and labor that are incurred at your site. There will be no cost for the replacement unit, if YMGI determines the defect is manufacturer related. Replacement will be made with the same model, only. Alternate units will be treated as a new order. CUSTOMER SERVICE / TECHNICAL SUPPORT FROM YMGI GROUP For questions or help with your unit, contact the original installer or servic

  • YMGI WMMS-12EC-V2B, P44 OF 44P43 OF 44 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! Put down whatever questions you have or problems you have seen as a unit history: No. Date USER NOTES Put down whatever questions you have or problems you have seen as a unit history: No. Date USER NOTES AND INSTALLATION/SERVICE/MAINTENANCE NOTES Notes Asked for Your Technician for Help? Did You Ask YMGI Tech. for Help? INSTALLA

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Caple CCH Instruction manual caple/cch-VB7.pdf 21 Oct 2022 11 0.25 Mb
2 Code Code Reader 1000 Operation & user’s manual code/code-reader-1000-398.pdf 16 Jun 2023 13
3 EarthWay M30 Assembly and operating instructions manual earthway/m30-I7F.pdf 18 Dec 2023 6 0.57 Mb
4 Frigidaire FRT05LG3DS Use & care manual frigidaire/frt05lg3ds-31Q.pdf 25 Feb 2023 9
5 Ulead PYRO1394DV Operation & user’s manual ulead/pyro1394dv-595.pdf 24 Aug 2023 64 2.64 Mb
6 Kenwood CD-2260M Instruction manual kenwood/cd-2260m-875.pdf 20 Jun 2022 29

Similar Resources:

  • EIC Solutions

    AAC-140C-4XT Series

    (11 pages)
    1-800-497-4524 WWW.EICSOLUTIONS.COM 215-443-5190 EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual FOR 400 Btu MODEL #’S AAC-140C-4XT AAC-140C-4XT-HC AAC-140C-4XT-XXXXX Cooling Solutions for Mission-Critical Electronics …
  • Panasonic

    CS-PZ9SKE

    (68 pages)
    Български Português Italiano Español Français EnglishACXF55-01510 Operating InstructionsAir Conditioner2-11Thank you for purchasing this Panasonic Air conditioner.Installation instructions attached.Before operating the unit, please read these operating instructions thoroughly and keep them for future reference.Comment utiliser l’appareilClimati …
  • ROYAL CLIMA

    RC-RNX24HN

    (70 pages)
    1 ROYAL CLIMA 2022 R410A Renaissance On/Off …
  • Fujitsu

    ASY24LBA-W

    (23 pages)
    SPLIT TYPE ROOM AIR CONDITIONERW A L L M O U N T E Dty peCONTENTSSPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1OUTLINE AND DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 3REFRIGERANT SYSTEM DIAGRAM . . . . . . . . . . . . . . . . . . . . 4ERROR CONTENTS . . . . . . . . . . . . . . . . . . . . . …
  • Mitsubishi Electric

    PEFY-P-VMR-E-L/R

    (200 pages)
    Air-ConditionersINDOOR UNITPEFY-P-VMR-E-L/R PFFY-P-VLRM(M)-E PEFY-P-VMH-E PLFY-P-VLMD-EPFFY-P-VLEM-E PEFY-P-VMA(L)-E PEFY-P-VMHS-E GBDFEINLPSVBEDIENUNGSHANDBUCHZum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.MANUEL D’UTILISATIONPour une utilisation correcte sans risques, veuillez li …
  • Airwell

    YBZE218-324-430

    (58 pages)
    R410AVersion:1HE AT PUMP SM YBZE H11 1-A.1 GB May -2013 Indoor UnitsOutdoor UnitsAWSI-HZDE009-H11 AWAU-YBZE218-H11AWSI-HZDE012-H11 AWAU-YBZE324-H11AWSI-HZDE018-H11 AWAU-YBZE430-H11YBZE218-324-430REFRIGERANT …

Comments, Questions and Opinions: