Manualios.com

Zibro P 227 Operating Manual

Zibro P 227 Manual Online:

4.55, 2351 votes
Zibro P 227 User Manual
Zibro P 227 User Guide
Zibro P 227 Online Manual

Text of Zibro P 227 User Guide:

  • Zibro P 227, P 227 - P 229 - PH 227 - PH 233 2 5 3 4 > 1 TR GEBRAUCHSANWEISUNG INSTRUCCIONES DE USO MANUEL D'UTILISATION OPERATING MANUAL ISTRUZIONI D’USO GEBRUIKSAANWIJZING KULLANIM KILAVUZU 4 22 38 54 70 88 104 man_Px2xx_1.qxd:man_P122-125.qxd5 22-12-10 15:55 Page 1

  • Zibro P 227, 2 2 ALLGEMEINE SICHERHEIT Aus Sicherheitsgründen bitten wir Sie, die Bedienungsanleitung vor Inbetriebnahme sorgfältig zu lesen! Personen, die mit der Bedienungsanleitung nicht vertraut sind, dürfen das Gerät nicht bedienen. 6 SIKKERHED GENERELT Læs denne brugsanvisning grundigt igennem af hensyn til sikkerheden! Personer, som ikke er fortrolige med brugsanvisningens indhold, må ikke anvende dette klimaanlæg. Vi anbefaler, at De gemmer denne brugsanvisning et sikkert sted med henblik på senere brug. 5 MEDIDAS DE SEGURIDAD ¡Consulte atentamente el modo de empleo y preste atención a las medidas de seguri

  • Zibro P 227, 3 > SICUREZZA Per motivi di sicurezza, si raccomanda di leggere attentamente il manuale prima di utilizzare l’apparecchio. Le persone che non conoscono il funzionamento del climatizzatore non devono usarlo. Si raccomanda di riporre il manuale in un luogo sicuro per future referenze. u GENERELL SIKKERHET Av sikkerhetshensyn ber vi deg lese denne håndboken nøye før drift. Personer som ikke har gjort seg kjent med denne håndboken, må ikke bruke klimaanlegget. Vi anbefaler på det sterkeste at du tar vare på denne

  • Zibro P 227, 1. FIRST READ THE INSTRUCTIONS. 2. IF YOU HAVE ANY DOUBTS, CONSULT YOUR DEALER. 4 54 IMPORTANT COMPONENTS Remote control Control panel Air outlet Air inlet Filter holder Air filters (activated carbon + Bacterio-static 3M TM HAF filter) Air duct (2x) Water drain Drainage point (PH227 + PH233) Handles Hose connector (4x) Electricity cable Hose adapter (2x) Wheels Air inlet for air to be cooled/filtered Air exhaust for air to be cooled/filtered Foam component Water hose (PH227 + PH233) Hose connector Hose adapter                                    

  • Zibro P 227, 4 55 Dear Sir, Madam, Congratulations on the purchase of your Zibro air conditioner. This air conditioner has five functions in addition to cooling the air, namely heating (for PH 227 + PH 233 only), air dehumidification, circulation and filtration as well as purification of air by it’s unique sterionizer bi-polar ionisation. The mobile air conditioner is extremely easy to operate and move. You have acquired a high quality product that will provide you with many years of pleasure, on condition that you use it responsibly. Reading these instructions for use before operating your air conditioner will optimise its life span. We wish you coolness and comfort with your Zibro air conditioner.

  • Zibro P 227, A SAFETY REGULATIONS Before connecting the device, check that: • The connection voltage corresponds to that on the type plate. • The socket and power supply are suitable for the device. • The plug on the cable fits the socket. • The device is on a stable and flat surface. Have the electrical installation checked by a recognised expert if you are not sure that everything is in order. • The airconditioner is a safe device, manufactured in accordance with CE safety standards. Nevertheless, as with every electrical device, exercise caution when

  • 4 57 • Children should be supervised to ensure that they do not play with the appliance. B INSTALLATION This unit is portable and can easily be moved from one room to another. In doing so keep this in mind: Ensure that the unit is positioned upright and on a level surface. Place the loose filters in the filter holder. • Take the filter holder  out o

  • Zibro P 227, Models are fitted with the EVS (Effective Ventilation System) as standard. The second hose  must be attached in order to utilise this option. Attach the hose connectors  and the hose adapter as described above. If use of the second hose is not possible or desired, then connecting a single hose to the air outlet  at the back of the airconditioner will suffice for the cooling mode. Keep windows and outside doors closed as much as possible in order to prevent the inflow of exterior air. The air that is i

  • Zibro P 227, 4 59 C OPERATION / REMOTE CONTROL Symbols: Automatic Cooling Dehumidifying Circulating air Heating (only on PH 227 + PH 233) High ventilator speed Average ventilator speed Low ventilator speed G ATTENTION! Without the remote control, the air-conditioner can be operated by using the button on the front of the device. In this event however, only the automatic function can be used. G ATTENTION! • Avoid the remote control from getting wet. Remove it from the unit when condensation can occur. On/off Fan speed Function s

  • PLACING BATTERIES IN THE REMOTE CONTROL Remove the battery cover by pressing the lips in and then pulling the cover toward you. Place the new batteries as indicated (pay attention to the plus- (+) and minus poles (-). Now replace the battery cover. Push the plug into the socket. By pressing both  and  set buttons at the same time, the display will toggle between Celsius and

  • Zibro P 227, 4 61 STERIONIZER TM FUNCTION Press Sterionizer TM function to start the function and press again to stop it. Positive and negative ions are generated in every operating mode. LOW NOISE BUTTON During unit operation. Press low noise button , unit operates at low noise. Press the button again to cancel the low noise setting and return to the previous setting. In low noise mode the unit will provide less cooling or heating capacity. COOLING When the cooling mode is activated, the transparent 1 / 2 - ring around the button on the front of the device  emits a BLUE light. The following settings are possible in the cooling mode: • The ventilator

  • water will be removed through the hose. The maximum rise may be 1.5 m from the floor on which the device is standing. Exceeding this distance may damage the machine or cause leaks. During the dehumidification, the ventilator speed can not be adjusted when room temperature is below 25°C. Below 25°C the fan speed is fixed to “low”. When the device is not being used in t

  • Zibro P 227, 4 63 switch on or off. Switching off The timer OFF function can be set when the airconditioner is switched on: • Press button • Set the number of hours desired (1-12) with the aid of  and  • Press to save Switching on Default temperature setting is 24°C. The timer ON function can be set when the airconditioner is switched off (stand-by): • Select the desired mode and temperature • Press button • Set the number of hours desired (1-12) with the aid of  and  • Press to save You can delete the set timer func

  • Wire mesh filter to remove coarse dust particles. Bacterio-static 3M TM HAF filter to remove particles from the air such as pollen, animal dander and dust. Activated carbon filter to remove odours. The mesh filter is part of the filter holder. The filter holder can be opened. The activated carbon filter and the Bacterio-static 3M TM HAF filter can be removed. The mesh filter must b

  • Zibro P 227, 4 65 E EMPTYING THE WATER RESERVOIR In extreme circumstances it may be necessary to empty the internal water reservoir. When the water reservoir is full, the transparent 1 / 2 - ring around the button on the front of the device  flashes RED. To empty the water reservoir, take the following action: Do not move the device. This may cause water leakage. First switch the device off and remove the plug from the socket. Place a pan or container on the floor under the water drain . Remove the rubber plug from the water drain  and let the water drain out (± 1 litre). Insert the rubber plug back into the water drain , push the plug i

  • Zibro P 227, Lead the other end of the water drain hose to suitable place (drain/sink). Ensure that the drain hose is not twisted or kinked. G MAINTENANCE Use a soft, damp cloth for the regular cleaning of the exterior of the device. Never use aggressive cleaning agents, solvents, benzene or abrasives. Refer to chapter D “Air Filter” for filter maintenance. H STORAGE Empty the water reservoir (see chapter E). Clean the mesh filter (see also chapter D). • Remove the activated carbon filter and the Bacterio-stati

  • Zibro P 227, 4 67 I PROBLEMS AND SOLUTIONS Never attempt to disassemble or repair the device. Inexpert repairs invalidate the guarantee and can endanger the users of the device. Problem Cause Solution The device does not work and the transparent 1/2 - ring around the button on the front of the device flashes RED. The internal water reservoir is full. Empty the internal water reservoir (see chapter E). The device does not work and the left hand side of the transparent 1/2 - ring around the button on the front of

  • Zibro P 227, J GUARANTEE CONDITIONS We provide a 24-month warranty on the airconditioner from the date of purchase. All material and production faults will be repaired free of charge within this period. The following rules apply: 1. We expressly reject all other claims for damage compensation, including consequent damage. 2. Repairs or replacements carried out during the guarantee period do not result in an extension of the guarantee. 3. The guarantee is invalidated when changes are made, non original parts are fitted or repairs are conducted by third parties. 4.

  • Zibro P 227, 4 69 K TECHNICAL SPECIFICATIONS Use indicatively, subject to change. * Conform EN 14511-2007, based on single duct use ** Moisture removal at 27°C, 60% RH *** See chapter B Environmental information: This equipment contains fluorinated greenhouse gases covered by the Kyoto Protocol. It should only be serviced or dismantled by professional trained personnel. This equipment contains R410A refrigerant in the amount as stated in the table above. Do not vent R410A into atmosphere: R410A, is a fluorinated greenhouse gas with a Global Warming

  • Zibro P 227, D Benötigen Sie weitere Informationen oder treten Probleme auf, besuchen Sie bitte unsere Website www.zibro.com, oder setzen Sie sich mit unserem Kundendienst in Verbindung (Telefonnummer auf www.zibro.com).  For alle yderligere oplysninger eller ved eventuelle problemer med apparatet henvises til www.zibro.com eller det lokale Kundecenter (telefon- numre findes i www.zibro.com).  Si necesita información o si tiene algún problema, visite nuestra página Web www.zibro.com, o póngase en contacto con el servicio cliente (hallará el número de teléfono en www.zibro.com). F Si vous souhaitez obtenir des in

More Instructions:

DOWNLOAD

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Behringer FEEDBACK DESTROYER PRO FBQ2496 Quick start manual behringer/feedback-destroyer-pro-fbq2496-66I.pdf 10 May 2023 15 1.77 Mb
2 Yealink W52H Quick start manual yealink/w52h-386.pdf 12 Nov 2023 12
3 Shield SNR150-100 Installation & service manual shield/snr150-100-YU3.pdf 18 Mar 2023 76
4 Philips SWA4521S/10 Information philips/swa4521s-10-1G4.pdf 12 Jun 2023 1 0.12 Mb
5 IKEA LANGSKAR AA-338821-2 Assembly instructions manual ikea/langskar-aa-338821-2-92L.pdf 26 Nov 2022 12
6 Vpon VP-8000 Operation & user’s manual vpon/vp-8000-G27.pdf 18 Jan 2024 21

Similar Resources:

  • Mitsubishi

    4G1 series

    (522 pages)
    BACKUPService ManualENGINEGROUP INDEX1992 - 1993Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . .FOREWORDThe information contained in this service manualhas been prepared for the professional automotivetechnician involved in daily repair operations. In-formation in this manual is divided into groups byengine models. Each group is further d …
  • LG

    HBLG8000R

    (15 pages)
    AIIi®C N ITIONEINPlease read the operating instructions and safety precautionscarefu/y and thoroughly before installing and operating yourroom air conditioner.M NUEL 'UTILICII oE= ,o_UIIONVeuilez/re atentivement et en entier ce guide d'ullsationet [es mesures de securite ci-inc[uses avant de proceder &rinstalation et au fonctionnement de votre …
  • HAMPTON BAY

    HBLG2504E

    (19 pages)
    ENERGYSTARN ITI NEPlease read the operating instructions and safety precautionscare_lly and thoroughly before installing and operating your roomair _nditioner.AI IClONAPor favor lea las instrucciones de operaci6n y las precauciones deseguridad cuiidadosa y totalmente antes de instalar y operar sua_ndicio, nado, r ,die aire de ventana.MODELS, MiODELOS: HBLG25 …
  • Airwell

    ST-NKSFL9

    (133 pages)
    NKSFLNK2FLNKFLNWFLNPFLNDLPNDHPNFFLNFMFLEFLRC85464359748002 2005W– FLOW LOGIC 3 pipe System Air Conditioner –INSTALLATION INSTRUCTIONSfor New Refrigerant R410A■ R410A ModelsIndoor UnitsOutdoor UnitsIndoor Unit Type 7 9 12 16 18 24 36 48NKSFL 1-Way Air Discharge ST-NKSFL9 ST-NKSFL12 ST-NKSFL18 ST-NKSFL24Semi-Concealed SlimNK2FL 2-Way Air Discharge ST- …
  • MAXA

    HWA-A Series

    (48 pages)
    REFRIGERATORI D’ACQUA E POMPE DI CALORE ARIA/ACQUA CON VEN-TILATORI ASSIALI E COMPRESSORI SCROLL DA 47 kW A 175 kW.AIR COOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS AND SCROLL COMPRESSORS FROM 47 kW TO 175 kW.AIR CONDITIONINGMANUALE TECNICOTECHNICAL MANUALTECHNISCHES HANDBUCHMANUEL TECHNIQUEMANUAL TECNICOSerie/Series/Serie/Série/SerieEmissione/Is …
  • AWA

    28K

    (19 pages)
    P/No. : 3A02045NPACKAGE AIR CONDITIONERSINSTALLATION INSTRUCTIONS• Please read this instruction sheet completely before installing the product.• When the power cable is wanted to replace, replacement work shall beperformed by authorized personnel only.• Installation work must be performed in accordance with national wiring standardsby authorized person …

Comments, Questions and Opinions: