Text of Truma Saphir comfort RC User Guide:

  • Truma Saphir comfort RC, 2 Table of contents Symbols used ......................................................................... 3 Safety instructions ............................................................. 3 Notes for the use of air conditioners .............................. 3 Operating instructions Remote control ....................................................................... 4 IR receiver and manual on / off .............................................. 5 IR receiver / operating indicator ............................................. 5 Red LED illuminates .....................................................

  • Truma Saphir comfort RC, 3 Symbols used Installation and repair of the device may only be carried out by properly qualified professionals. Symbol indicates a possible hazard. Comment including information and tips. Safety instructions Repairs may only be carried out by properly qualified professionals! In order to avoid transport damage, the unit may only be dis- patched after consulting Domestic Service. The voltage must be disconnected at all poles before the housing is opened. The 230 V, T 6.3 A H-type (slow, IEC 127) fuse in the unit can be found on the electronic control unit and must always be replaced with an identical fuse. Appliance fu

  • Truma Saphir comfort RC, 4 Before starting to use the device, it is essential that the Operating Instructions and “Safety instructions” be read carefully. The vehicle owner is responsible for ensuring that the device can be operated in the proper manner. Remote control The symbols shown on the display become visible depending on the setting. Operating instructions Sleep function (cooling mode only) Ultra-quiet fan Set-up button Pairing the remote control and IR receiver Mode Operating mode selection button – Cooling – Heating – Automatic – Circulated air Temperature selection buttons 16 – 31 °C In 1°C incr

  • Truma Saphir comfort RC, 5 IR receiver and manual on / off There is an additional pushbutton on the receiver (m), with which the unit can also be switched on and off without the remote control (e.g. with a ballpoint pen). If the unit is switched on using this pushbutton, the system is automatically reset to the factory settings (Automatic mode, 22 °C). IR receiver / operating indicator m LED 1 LED 2 LED 3 LED 1 blue – permanently on – (cooling mode) LED 1 blue – flashing – (cooling mode compressor start-up) LED 2 yellow – permanently on – (heating mode) LED 2 yellow – flashing – (heating mode compressor start-up) LED 3 red – flashing – (data is

  • Truma Saphir comfort RC, 6 Timer ON / OFF The air conditioning unit on / off time can be set in advance from a minimum of 15 minutes up to a maximum 24 hours, starting from the current time. To carry out programming, switch on the unit with the remote control. Set the required operating mode and room temperature. Then select TIMER ON or TIMER OFF using the “TIMER selection buttons”. Set the required on / off time using the “Time setting” buttons (15 minutes – 24 hours) and confirm with TIMER ON or TIMER OFF. Press the relevant timer button again to deactiv

  • 7 IR remote handset battery change Please be sure to use leak-proof micro-batteries only, type LR 3, AM4, AAA, MN 2400 (1.5 V). The battery compartment is located on the rear of the remote control unit. When fitting new batteries, ensure the polarity (positive / negative) is correct! Dead and used batteries may leak and damage the remote control unit. Remove t

  • Truma Saphir comfort RC, 8 Installation dimensions Ø 50 KO Saphir comfort RC LA HW HW LE 620 186 301 400 197,5 74 96 213,5 81 15 122 28 10 Ø 50 KO 488 The dimensions are in mm. Declaration of conformity 1. Information about the manufacturer Name: Truma Gerätetechnik GmbH & Co. KG Address: Wernher-von-Braun-Str. 12, D-85640 Putzbrunn 2. Device identification Type / Model: Air conditioning unit Saphir comfort RC 3. Meets the requirements of the following EC Directives 3.1 Electromagnetic Compatibility 2004/108/EC 3.2 Low Voltage Directive 2006/95/EC 3.3 Suppression of radio interference of

  • Truma Saphir comfort RC, 9 Installation and repair of the device may only be carried out by properly qualified professionals. Before star- ing work, read the installation instruc- tions thoroughly and follow them carefully! Scope of delivery – 1 Saphir comfort RC – 1 remote control with batteries – 1 IR receiver – 4 mounting brackets with screws, 1 strap – 2 condensate drains – 2 floor grids – 1 installation template – 1 operating instructions / installation instructions Intended use This unit was design

  • Truma Saphir comfort RC, 10 Seal the circumference of connectors (11) for draining con- densate from below with automotive body sealant. When installing the unit, it is vital to ensure that the connectors (11) to the condensate drainage are located in the recess at the bottom of the device. Oth- erwise there is a risk of water penetrating the interior! In order to provide good air circulation, the openings in the bottom of the unit and the floor must align exactly. Correct operation of the unit cannot be guaranteed un- less this is the case! p n 7 8 9

  • Truma Saphir comfort RC, 11 Installing the IR receiver The receiver (12) is to be fitted for preference on the clothes cabinet in such a way that the remote control can be pointed at it without any hinderance (length of connection cable 3 m). If necessary, a 3 metre cable extension can be supplied (part no. 40090-89100). If the receiver cannot be flush-mounted, Truma can provide an on-surface frame (13) – part no. 40000-52600 as an accessory if required. Drill Ø 55 mm hole. Lead IR receiver cable (17) through towards the rear and secure receiver with 4 screws (14 – not provided). Then clip on the cover frame (15) and route cable (17) t

  • Truma Saphir comfort RC, In Australia, always notify the Dometic Service Centre if problems are encountered; in other countries the relevant service partners should be contacted (see Service Booklet or www.truma.com). Having the equipment model and the serial number ready (see type plate) will speed up processing. 40091-50100 · 00 · 11/2012 · © Service (Australia) Telephone: +61 (0)3 92 39 10 00 Facsimile: +61 (0)3 92 39 10 99 Dometic Pty Ltd Building 3B, Clayton Business Park 1508 Centre Road Clayton, Victoria, 3168 Australia Dometic New Zealand Ltd

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Lifesaver jerrycan Instruction manual lifesaver/jerrycan-N1T.pdf 30 Jul 2023 20
2 Nokia 2160i Owner's manual nokia/2160i-6OG.pdf 05 May 2023 67
3 Panasonic TC-P50VT25X Operating instructions manual panasonic/tc-p50vt25x-2S5.pdf 02 Aug 2023 148 9.22 Mb
4 Polycom SoundStation IP 4000 Quick start manual polycom/soundstation-ip-4000-NBM.pdf 11 Oct 2023 2
5 Samsung SMART TV 6500 Specifications samsung/smart-tv-6500-FZD.pdf 24 Mar 2024 2
6 Ide Line 751-082 Instruction manual ide-line/751-082-UF9.pdf 05 Sep 2023 14

Similar Resources:

  • LG

    Multi V 5 ARUM160LTE5

    (55 pages)
    MFL67221448Rev. 01_091818INSTALLATION MANUALAIRCONDITIONERwww.lg.comPlease read this installation manual completely before installing the product.Installation work must be performed in accordance with the national wiring standards by authorized personnel only.Please retain this installation manual for future reference after reading it thoroughly.For Heat Pum …
  • Midea

    PH Series

    (34 pages)
    MIDEA 50Hz PORTABLE PH SERIES …
  • Daikin

    DPS

    (82 pages)
    Installation and Maintenance Manual IM 919-3Group: Applied Air SystemsPart Number: IM 919Date: October 2014MicroTech® III Controller for Commercial Rooftop Systems, Applied Rooftop Systems and Self-Contained Air ConditionersModels: DPS, MPS, RAH, RCS, RDS, RDT, RFS, RPE, SWP and SWT …
  • ICP

    PAB075N2HB

    (19 pages)
    InstallationInstructions80-30-04Contents1. Unit Dimensions ................... 21. Safety Labeling And Signal Words .. 32. Safe Installation Requirements ..... 33. Locating the Unit .................. 44. Electrical Wiring ................... 75. Air Distribution System ............. 96. Economizer Accessory ........... 107. Start-up Procedures ............. …
  • Haier

    HSU-18HA103/R2 - annexe 1

    (30 pages)
    SPLIT TYPE ROOM AIR CONDITIONEROPERATION MANUALPlease read this operation manual before using the air conditioner.No.00105HSU-09H03/R2(DB)HSU-12H03/R2(DB)HSU-18H03/R2(DB)HSU-22H03/R2(DB)HSU-12HB03/R2(DB)HSU-18HA103/R2(DB)HSU-22HA103/R2(DB)HSU-09HA103/R2(DB)HSU-12HA103/R2(DB) …
  • Bergstrom

    NITE Phoenix

    (70 pages)
    1 Installation Manual ANTHEM 2390 Blackhawk Road ● Rockford, IL 61109 ● www.nitesystem.com ● 1-866-204-8570The information contained herein is proprietary to Bergstrom Inc and/or its subsidiaries shall not be reproduced, copied, or disclosed in whole or in part, or used for manufacture or any other purpose, without prior writ …

Comments, Questions and Opinions: