Manualios.com

Turbo Air TAS-09MVHN Service Manual

Turbo Air TAS-09MVHN Manual Online:

3.4, 2952 votes
Turbo Air TAS-09MVHN User Manual
Turbo Air TAS-09MVHN User Guide
Turbo Air TAS-09MVHN Online Manual

Text of Turbo Air TAS-09MVHN User Guide:

  • Turbo Air TAS-09MVHN, CONTENTS 1. Precaution .................................................................................................................................................... 1  1.1 Safety Precaution........................................................................................................................1 1.2 Warning .......................................................................................................................................1 2. Function........................................................................................................................................................ 6  3. Dim

  • Turbo Air TAS-09MVHN, 1 1. Precaution 1.1 Safety Precaution  To prevent injury to the user or other people and property damage, the following instructions must be followed.  Incorrect operation due to ignoring instruction will cause harm or damage.  Before service unit, be sure to read this service manual at first. 1.2 Warning ¾ Installation  Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit. There is risk of fire or electric shock.  For electrical work, contact the dealer, seller, a qualified electrician, or an authorized service center. Do not disassemble or repair the product, there is ris

  • Turbo Air TAS-09MVHN, 2  For installation, always contact the dealer or an Authorized service center. There is risk of fire, electric shock, explosion, or injury.  Do not install the product on a defective installation stand. It may cause injury, accident, or damage to the product.  Be sure the installation area does not deteriorate with age. If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.  Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open. M

  • Turbo Air TAS-09MVHN, 3  If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect the power supply cable. There is risk of electric shock or fire.  Stop operation and close the window in storm or hurricane. If possible, remove the product from the window before the hurricane arrives. There is risk of property damage, failure of product, or electric shock.  Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.) There is risk of physical injury, electric shock, or product failure. 

  • 4 the neighborhoods. It may cause a problem for your neighbors.  Use two or more people to lift and transport the product. Avoid personal injury.  Do not install the product where it will be exposed to sea wind (salt spray) directly. It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could ca

  • 5 It is not sanitary could cause serious health issues.  Use a firm stool or ladder when cleaning or maintaining the product. Be careful and avoid personal injury.  Replace the all batteries in the remote control with new ones of the same type. Do not mix old and mew batteries or different types of batteries. There is risk of fire or explosion.  Do not recharge or disassembl

  • Turbo Air TAS-09MVHN, 6 2. Function Tele Remote control (Optional) Maintain the room temperature in accordance with the setting temperature. The louver can be set at the desired position or swing up and down automatically The function is usually used in rainy days in springtime or damp areas. The unit will decide the louver direction according to operation mode. high, med, low, breeze, auto Indoor unit Operation by remote controller Sensing by temperature sensor Room temperature control Anti-freezing control in cooling Time Delay Safety control Indoor fan speed control Two-direction air vane Sl

  • Turbo Air TAS-09MVHN, 7 3. Dimension Dimension of indoor unit Position of installation board Dimension Model W H D TAS-09MVHN Model R L H Dimension of installation hole φ φ 795 mm 31.30 inch 270 mm 10.63 inch 165 mm 6.5 inch 165 mm 6.5 inch 165 mm 6.5 inch TAS-12MVHN 845 mm 33.27 inch 286 mm 11.26 inch TAS-09MVHN TAS-12MVHN 160 mm 6.28 inch 150 mm 5.91 inch 45 mm 1.77 inch 45 mm 1.77 inch 150 mm 5.91 inch 65 mm 2.56 inch 65

  • Turbo Air TAS-09MVHN, 9 5. Operation characteristics CAUTION: 1. If air conditioner is used outside of the above conditions, certain safety protection features may come into operation and cause the unit to function abnormally. 2. Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the surface of the air conditioner may attract condensation. Please set the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode. 3. Optimum performance will be achieved within this operating

  • Turbo Air TAS-09MVHN, 10 6. Electronic function 6.1 Abbreviation T1: Indoor ambient temperature T2: Coil temperature of indoor heat exchanger middle. T2B: Coil temperature of indoor heat exchanger outlet. T3: Coil temperature of outdoor heat exchanger T4: Outdoor ambient temperature T5: Compressor discharge temperature Ts:Setting temp. 6.2 Display function 6.2.1 Icon explanation on indoor display board. TIMER display Illuminated during Timer operation. CLEAN AIR display(optional) Illuminated when Ionizer is activated. TURBO operation d

  • Turbo Air TAS-09MVHN, 11 6.3 Main Protection 6.3.1 Three Minutes Delay at restart for compressor. 6.3.2 Fan Speed is out of control. ----When Indoor Fan Speed keeps too low or too high for certain time, the unit will stop and the LED will display the failure 6.3.3 Indoor fan delayed open function ----When the system starts up, the louver will be active immediately and the indoor fan will open 10s later. ----If the system runs in heating mode, the indoor fan will be also controlled by anti-cold wind funtion. 6.3.4 Zero crossing detection

  • 12 6.4 Operation Modes and Functions 6.4.1 Fan mode. (1) The outdoor fan and compressor stop. (2)Temperature setting function is disabled, and no setting temperature is displayed. (3) Indoor fan can be set to high/med/low/auto. (4) The louver operates the same as in cooling mode. (5) Auto fan: The action of auto fan in fan-only mode is the same as auto fan in ℃ settin

  • Turbo Air TAS-09MVHN, 13 6.4.2.2 Indoor fan running rules In cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and auto. Auto fan in cooling mode acts as follow: 6.4.2.3 Evaporator low temperature T2 protection. When T2<4 / (39.2F), ℃ the indoor has no capacity demand and resume till T2>8 (46.4F) ℃ . 6.4.2.4 Outdoor fan running rules: 22 20 High Low 38.3 37.4 34.7 33.8 71.6 68

  • Turbo Air TAS-09MVHN, 14 6.4.3 Heating Mode 6.4.3.1 Compressor running rules: The compressor will run at corresponding frequency according to the gross amendatory capacity demand. Frequency(Hz) 0 HEAT_F1 HEAT _F2 …… HEAT _F11 HEAT _F12 Amendatory capacity demand. 0 1 2 …… 11 ≧12 6.4.3.2 Indoor fan running rules: Indoor fan speed can be set as high, medium, low or auto fan and the anti-cold-wind function is preferential. 44 38 37 34 33 Setting Low Breeze Off 17 Auto fan action in heating mode. 6.4.3.3

  • Turbo Air TAS-09MVHN, 15 6.4.3.3 High evaporator coil temp.T2 protection: If T2>63℃ , the indoor unit has no capacity demand and resume till 48 ℃ . 6.4.3.4 Defrosting mode: Condition of defrosting: T3≦TCDIN and lasts for 40 minutes. TCDIN=-2℃. Defrosting action: Compressor 4-Way valve Outdoor fan Indoor fan 30S 10S COOL_F9 10S 30S 10S HEAT_F2 Condition of ending defrosting: If any one of following items is satisfied, defrosting will stop and the machine will turn to normal heating mode. ① T3 >TCDE; TCDE=15℃. ② The defrosting time achieves 10min. 6.4.4 Auto-mode This mode can be chosen by remote controller and the setting temperature can be changed

  • 16 The louver operate same as in relevant mode. If the machine switches mode between heating and cooling, the compressor will keep stopping for 15 minutes and then rechoose mode according to T1-Ts. If the setting temperature is modified, the machine will rechoose running function. 6.4.5 Dehumidifier mode 6.4.5.1 Indoor fan speed is fixed at breeze and

  • Turbo Air TAS-09MVHN, 17 6.4.6.5 The slave forced cooling units will not be controlled by other signals except timer off signal. 6.4.6.6 If AC is running in sleep mode and receives forced operation signal, it will quit the sleep mode. 6.4.7 Timer function 6.4.7.1 Timing range is 24 hours. 6.4.7.2 Timer on. The machine will turn on automatically when reaching the setting time. 6.4.7.3 Timer off. The machine will turn off automatically when reaching the setting time. 6.4.7.4 Timer on/off. The machine will turn on automatically when reaching the setting “on” time, and then turn off autom

  • Turbo Air TAS-09MVHN, 18 automatically after 3 minutes when power returns. If the memorization condition is forced cooling mode, the unit will run in cooling mode for 30 minutes and turn to auto mode as 24 (75.2 ) setting temp.℃ 6.4.10 Ionizer/Plasma dust collector function (optional) The indoor unit is equipped with Ionizer, which is controlled by the CLEAN AIR button on the remote controller. When the unit is turned on, press the CLEAN AIR button to activate the function. Press it again to stop the function. During the time when Ionizer is controlled by remote contr

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 GE DLSR483GG4WW Installation instructions manual ge/dlsr483gg4ww-91A.pdf 10 Sep 2022 8 1.26 Mb
2 Hasbro Spiderman 3 Venom Mask and Wrist Blaster 69164 Instruction manual hasbro/spiderman-3-venom-mask-and-wrist-blaster-69164-279.pdf 07 Nov 2023 2 2.65 Mb
3 GRAUPNER 3D Copter Alpha 300 Q Assembly instructions manual graupner/3d-copter-alpha-300-q-E6S.pdf 22 Sep 2023 16
4 AVIRA ANTIVIR WEBGATE SUITE Installation and configuration manual avira/antivir-webgate-suite-4WV.pdf 29 Mar 2023 15 3.2 Mb
5 Life Fitness T5-0 Assembly instructions life-fitness/t5-0-2PC.pdf 17 Jan 2024 2
6 Makita RBC201 Instruction manual makita/rbc201-GGK.pdf 21 Jul 2022 24

Similar Resources:

  • Continental Electric

    PAC-800

    (66 pages)
    Seaim _nvlcisa "_alning and Edu_etionIElectricIncluded in this manual is all available information coveringthe Continental portable air conditioners. Models are beingsold outside the U.S. as well as inside the U.S. Although theunits may have different model numbers, both the customerand service information are the same. Listed below are theEuropean mode …
  • Bosch

    Climate 8000 RAC

    (20 pages)
    Owner’s Manual 6 720 869 160 (2016/12) SPLIT-TYPE ROOM AIR CONDITIONER BOSCH Climate 8000 RAC All Model Numbers Owner’s Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference. 6 720 869 160 (2016/12) …
  • Samsung

    AQV09FAN

    (28 pages)
    E-2ContentsCorrect Disposal of This Product (Waste Electrical & Electronic Equipment)(Applicable in the European Union and other European countries with separate collection systems)This marking shown on the product or its literature, indicates that it should not be disposed with other household waste at the end of its working life. To prevent possible h …
  • Johnson Controls Unitary Products

    LX Series

    (38 pages)
    TECHNICAL GUIDELX SERIESSPLIT SYSTEM AIR CONDITIONERS13 SEER – R-410A – 1 PHASE1.5 THRU 5 NOMINAL TONSMODELS: RAC13L18 THRU 60Due to continuous product improvement, specifications are subject to change without notice.Visit us on the web at www.upgnet.comAdditional rating information can be found at www.ahridirectory.orgWARRANTY SUMMARY*Standard 5-Years l …
  • Daikin

    FT50FVM

    (24 pages)
    EnglishEspañolPortuguesРóссêийFT50FVMFT60FVMMODELSDAIKIN ROOM AIR CONDITIONEROperation Manual00_CV_3P192025-3.fm Page 1 Tuesday, September 26, 2006 11:20 AM …
  • NEC

    RSC1711

    (27 pages)
    ROOM AIR CONDITIONEROWNER'S MANUAL MODEL NO: RSC1711, RSH1721RSC2411, RSH2421Thank you for purchasing the NEC room air-conditioner. All NEC products have beencarefully designed and prepared at the factory under strict quality guide lines.We are confident that this product will give you daily comfort and satisfaction if it is handledproperly based on thi …

Comments, Questions and Opinions: