  • Siemens FT2080, Legal notice 2 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 Legal notice Technical specifications and availability subject to change without notice. © Siemens Switzerland Ltd, 2015 Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved. Issued by: Siemens Switzerland Ltd. Bui

  • Siemens FT2080, 3 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 Table of contents 1 Setup of fire terminal (Touch) FT2080 ...........................................................4 2 Installation in 19" pedestal housing of the FC2080.......................................6 3 Installation in housing (standard) ..................................................................9 4 Installation in rear panel (FT2080) FHA2039 ................................................ 10 5 Installation in desktop housing (FT2080) FHA2040 .................................... 15 6 Technical d

  • Siemens FT2080, 1 Setup of fire terminal (Touch) FT2080 4 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 1 Setup of fire terminal (Touch) FT2080 4 6 2 3 5 6 4 1 4 4 Rear panel fire terminal (Touch) FT2080 1 Support plate 2 Front indicator (Touch) FTO2010 3 PMI & mainboard FCM2027 4 4x mounting hole operating unit 5 Shield plate above carrier (CPU) 6 Hinges for wall housing

  • Siemens FT2080, Setup of fire terminal (Touch) FT2080 1 5 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 Arrangement of components Components on the fire terminal (Touch) FT2080, without cover cap 1 Front indicator (Touch) FTO2010 2 Main network module (SAFEDLINK) on X13, optional 3 License key, optional 4 Slot 1 [SER_OPT1] for the first serial module at X14, optional 5 Slot 2 [SER_OPT2] for the second serial module at X19, optional 6 Degraded mode network module (SAFEDLINK) on X12, optional 7 CPU module (CORVUS) FCC2009 8 Carrier for CPU modules FTO2014 9 CPU module (M

  • 2 Installation in 19" pedestal housing of the FC2080 6 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 2 Installation in 19" pedestal housing of the FC2080 The installation instructions described below apply to all operating units. Before an operating terminal is installed, the following components must first be installed on the operating unit. l Netwo

  • Installation in 19" pedestal housing of the FC2080 2 7 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 1 Operating unit 2 Flange with threaded holes for securing the module 3 Connector strip X13 for network module 4 Network module (SAFEDLINK) FN2001-A1 with ES ≥ 12 5 2x fixing screw 6 PMI & mainboard FCM2027 7 Adapter for power supply

  • Siemens FT2080, 2 Installation in 19" pedestal housing of the FC2080 8 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 3. The operating add-ons in the bottom window openings are installed in the same way. 4. Wire up the operating unit and operating add-ons according to the following wiring instructions. Wiring the fire terminal (Touch) 1 2 3 4 5 6 Wiring the fire terminal (Touch) with FC2080 1 Ribbon cable for FC2080 system supply to card cage (CPU) X30 2 FCnet connection to card cage (CPU) X11/X12 3 X3 connection to network module (

  • Siemens FT2080, Installation in housing (standard) 3 9 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 3 Installation in housing (standard) Installation of fire terminal in the housing (standard) FH2002 1 Mains connection terminals 2 Power supply unit (70 W) FP2015 3 Rear panel (standard) 4 Fire terminal board FTI2001 5 Wiring FCnet/SAFEDLINK 6 Network module (SAFEDLINK) FN2001 7 Fire terminal (Touch) FT2080 X3 Ribbon cable connection from the fire terminal (Touch) to the fire terminal board X1 Supply input f

  • Siemens FT2080, 4 Installation in rear panel (FT2080) FHA2039 10 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 4 Installation in rear panel (FT2080) FHA2039 The rear panel (FT2080) can be used for installation in a desk or installation in a third-party housing. Installing the rear panel (FT2080) in a third-party housing guarantees the required EMC protection. The installation sequence is as follows, due to the restricted space: l Installing the fire terminal board FTI2001 l Wiring the fire terminal (Touch) l Installing the fire terminal (Touch) l Installing the rear panel (FT2080)

  • Siemens FT2080, Installation in rear panel (FT2080) FHA2039 4 11 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 Installing the fire terminal board FTI2001 1 2 3 4 5 Installing the fire terminal board in the rear panel (FT2080) 1 Rear panel (FT2080) FHA2039 2 Fire terminal board FTI2001 3 4x fixing screw 4 4x mounting hole 5 Threaded press-in sleeves in rear cover (FT2080) 1. Position the fire terminal board (2) in the rear panel (1) as shown. 2. Use the four fixing screws (3) to screw the fire terminal board (2) in the rear panel (1) firmly onto the threaded press-in sleeves (5).

  • Siemens FT2080, 4 Installation in rear panel (FT2080) FHA2039 12 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 Wiring the fire terminal (Touch) When installing in a desktop that is thicker than 33 mm, the cables must be routed through the rectangular openings of the rear panel (FT2080), and not through the round cable breakthroughs. Wiring view of the fire terminal (Touch) in the rear panel (FT2080) 1 Fire terminal (Touch) FT2080 2 Network module (FCnet/SAFEDLINK) FN2001 3 FCnet connection cable 4 Prefabricated cable for supply connection to X7 5 EMC filter 6 Input for DC 24 V system supply to EMC filter 7 Fire terminal board FTI2001

  • Installation in rear panel (FT2080) FHA2039 4 13 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 1. Wire up the flat cable from the fire terminal board X3 to the PMI & mainboard X3. 2. Wire up the prefabricated cable of the supply from the EMC filter to the fire terminal board X7. 3. Wire up the external cables of the supply, the FCnet and the Ethernet cabl

  • Siemens FT2080, 4 Installation in rear panel (FT2080) FHA2039 14 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 1. Position the wired-up fire terminal (Touch) (1) on the rear panel (7) as shown. 2. Screw the four fixing screws (2) through the holes (3) to secure the fire terminal (Touch) (1) into the threaded holes (5) in the rear panel. Installing the rear panel (FT2080) in a desktop 5 6 7 4 1 2 3 Installing the rear panel (FT2080) in a desktop 1 Rear panel (FT2080) FHA2039 2 Mounted fire terminal (Touch) FT2080 3 4x fixing screw 4 Mounting holes in the flanges of the rear panel (FT2080) 5 Bores in the desktop 6 Desktop 7 Cutout for re

  • Siemens FT2080, Installation in desktop housing (FT2080) FHA2040 5 15 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 5 Installation in desktop housing (FT2080) FHA2040 1 2 3 10 4 5 6 7 8 9 11 View of desktop housing (FT2080) 1 Top of desktop housing 2 Tilting bracket for top of housing 3 Base of desktop housing 4 M4x10 pan head screw (scope of delivery) 5 Clamping bracket for ground cable (scope of delivery) 6 250 V EMC filter, 3 A with plug-in contacts (mounted) 7 Fixing screw by customer 8 Washer 5/15 mm (scope of delivery) 9 4x. Rubber grommet (scope of delivery) 10 Spac

  • Siemens FT2080, 5 Installation in desktop housing (FT2080) FHA2040 16 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 1. Remove the top of housing (1) by pushing the two tilting brackets (2) on the left and right inwards until you can lift off the top of housing. 2. Connect the ground connection as shown with clamping bracket (5) and M4 pan head screw (4). 3. Place the spacer sleeves (10) from below over the rubber feet (9). 4. Position the housing (3). 5. Place the washers (8) onto the rubber feet (9) inside the housing. 6. Screw the housing (3) tight with a screw (7) suitable for the substructure. Installing fire terminal board FTI2001 2 1 4 3 Installing fire terminal board in desktop

  • Siemens FT2080, Installation in desktop housing (FT2080) FHA2040 5 17 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 Installing fire terminal (Touch) FT2080 2 4 3 1 5 1 2 3 Mounting fire terminal in the cover of the desktop housing 1 Tilting brackets on left and right for fixing the cover 2 2x fixing screw for tilting brackets and fire terminal 3 2x fixing screw for fire terminal 4 Fire terminal (Touch) FT2080 5 Cover of desktop housing (FT2080) FHA2040 1. Place the fire terminal (4) in the cover (5) of the desktop housing as shown. 2. Screw the tilting brackets (1) into the cover on the left and right as shown through the top holes i

  • Siemens FT2080, 5 Installation in desktop housing (FT2080) FHA2040 18 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 Assembly of desktop housing (FT2080) 6 1 5 2 5 3 4 Assembly of desktop housing 1 Fire terminal (Touch) FT2080 2 Cover of desktop housing (FT2080) FHA2040 3 Tilting brackets on left and right for fixing the cover 4 Guide cams on left and right for tilting brackets 5 2x threaded holes for mounting cover 6 Base of desktop housing 7 Fire terminal board FTI2001 1. Move the cover (2) with the installed fire terminal (1) to the position shown. 2. Gently press the two tilting brackets (3) inwards and lift the

  • Siemens FT2080, Installation in desktop housing (FT2080) FHA2040 5 19 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 1 2 1 3 4 Securing cover for desktop housing 1 Securing cap (scope of delivery) 2 Opening for fixing screw 3 Cover for desktop housing (Touch) 4 Fixing screw with securing device 1. To close the housing, tilt the cover (3) onto the housing and secure the cover to the housing using both screws (4). 2. Close the openings for the fixing screws (2) using both securing caps (1)

  • Siemens FT2080, 5 Installation in desktop housing (FT2080) FHA2040 20 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 Fire terminal wiring Wiring view of the fire terminal in the desktop housing 1 Fire terminal (Touch) FT2080 2 Network module (FCnet/SAFEDLINK) FN2001 3 Fire terminal board FTI2001 4 Prefabricated cable for supply connection to X7 fire terminal board 5 FCnet connection cable 6 EMC filter 7 Input for DC 24 V system supply to EMC filter 8 Internal cable RJ45 for Ethernet connection, L=420 mm

  • Technical data 6 21 Building Technologies A6V10462660_en--_a Fire Safety 2015-09-10 6 Technical data Supply input Voltage DC 20…30 V Quiescent current (display illumination dimmed 15%) 390 mA Maximum current (display illumination 100% and lamp test active) 700 mA Display Screen size 12" Resolution 1280 x 800 pixels Interfaces 2x slots for serial modules l RS232 mod

  • Siemens FT2080, Issued by Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies © Siemens Switzerland Ltd, 2015 Technical specifications and availability subject to change without notice. Document ID A6V10462660_en--_a A5Q00068323 FS20 Edition 2015-09-10

Related Products and Documents (Touch terminals):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Philips AX5015 Specifications philips/ax5015-1ZJ.pdf 02 Mar 2024 2 0.19 Mb
2 Future light Spotlight MH-660 Operation & user’s manual future-light/spotlight-mh-660-Z7Z.pdf 03 Oct 2022 100
3 Siemens 5WK4 3402 Operation & user’s manual siemens/5wk4-3402-K98.pdf 22 Nov 2022 6
4 Panasonic TH-58PX600U Service manual panasonic/th-58px600u-NRG.pdf 14 Jul 2023 185
5 DURKOPP ADLER 967 Instruction manual durkopp-adler/967-927.pdf 22 Sep 2023 92
6 LG LDX-514 Warranty lg/ldx-514-JRF.pdf 12 Feb 2023 1

Similar Resources:

  • Datalogic

    Elf

    (111 pages)
    Elf™©2010 Datalogic Mobile S.r.l.05/10www.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitalino, 1340012 Lippo di Calderara di RenoBologna - ItalyTelephone: (+39) 051-3147011Fax: (+39) 051-3147561World wide Sales Networkavailable from: www.mobile.datalogic.com/contactsUser’s Manual …
  • POS-X

    ION

    (33 pages)
    Version 1.0 August 2014 Fit POS Terminal User ManualPOS-X Warranty POS-X Service and SupportIndustry-leading Warranty Protection• 3 year warranty• *2-day Advance Exchange - standard on all products• Warranty extensions and overnight exchanges are available to provide means to further reduce the total cost of ownership24/7 Technical S …
  • dejavoo

    Z11

    (3 pages)
    Dejavoo Z11Initial Setup of the Dejavoo Z11 Plug the power cable into the outlet and power on the device. Connect the device to your network via Ethernet/WiFi. Press the green “OK” button and type in the default password “1234” Press “Utility” and type in the default password again. Press “Communications” then “Print Details� …
  • Ingenico

    FLEX IPP320

    (32 pages)
    FLEX iPP320 PAYMENT TERMINAL INSTALLATION GUIDE Prepared by : Frédérick Matte Technical Support Advisor Bell Canada Created : January 24th, 2012 Revised : July 11th, 2014 …
  • Safran

    MorphoAccess SIGMA Series

    (478 pages)
    COPYRIGHT© 2016 Morpho Osny, France MorphoAccess® SIGMA Series – Administration Guide May 2016 2014_0000002196-09 MorphoAccess® SIGMA Series Administration Guide …
  • Tyco Electronics

    1338600 Series

    (34 pages)
    409-10016Customer ManualEntry Level Terminator1of 34LOC BE2008 Tyco Electronics Corporation, Harrisburg, PAAll International Rights ReservedTE logo and Tyco Electronics are trademarks.*Trademark. Other products, logos, and company names used are the property of their respective owners.TOOLING ASSISTANCE CENTER 1-800-722-1111 This controlled document is subje …

Comments, Questions and Opinions: