  • RF600 system planning 4.3 Antenna configurations SIMATIC RF600 50 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW Antenna alignment and antenna spacing with an external antenna The minimum distance required between antennas that use the same frequency and that are connected to different readers depends on the set maximum radiated power and the

  • Siemens Simatic RF600, Readers 5.6 RF670R reader SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 191 REVIEW Mechanical environmental conditions Shock resistant acc. to EN 60068-2-27 Vibration acc. to EN 60068-2-6 50 g 1 20 g 1 Climatic conditions Ambient temperature during operation -25 °C to +55 °C (a 10-minute warm-up time must be allowed at an operating temperature below -20 °C) Ambient temperature for transport and storage -40 °C to +85 °C 1) The values for shock and vibration are maximum values and must not be applied continuously.

  • Siemens Simatic RF600, Readers 5.2 RF620R reader SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 93 REVIEW 5.2.1.4 Pin assignment of the connecting cable Table 5- 3 RS 422 - on reader side M12 pin Core color Pin assignment View of M12 socket 1 white 24 VDC 2 brown TX neg 3 green GND 4 yellow TX pos 5 Gray RX pos 6 pink RX neg 7 blue Not assigned 8 red Earth (shield) Comment This cable has an 8-pin M12 connector at one end and the other cable end is 'open'. There are 8 color-coded single cores there for connecting to external devices. There are different cable len

  • Siemens Simatic RF600, Antennas 6.2 RF620A antenna SIMATIC RF600 258 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW Directional radiation pattern ETSI on metallic mounting surface (15 cm x 15 cm) Pattern of the vertical plane of the antenna Pattern of the horizontal plane of the antenna Figure 6-6 Directional radiation pattern RF620A ETSI on metallic mounting surface

  • Siemens Simatic RF600, Antennas 6.3 Antenna RF640A SIMATIC RF600 274 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW 6.3.2 Ordering data Table 6- 16 Ordering data RF640A Product Article number SIMATIC RF640A 6GT2812-0GA08 Accessories Table 6- 17 Ordering data accessories Product Article number Connecting cable between reader and antenna 3 m (cable loss 1.0 dB) 6GT2815-0BH30 5 m, suitable for drag chains (cable loss 1.25 dB) 6GT2815-2BH50 10 m (cable loss 2.0 dB) 6GT2815-1BN10 10 m (cable loss 4.0 d

  • Readers 5.4 RF640R reader SIMATIC RF600 146 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW Radiation diagram (elevation section) Vertical component of the polarization direction of the antenna Horizontal component of the polarization direction of the antenna Right circular component of the polarization direction of the antenna Figu

  • Siemens Simatic RF600, RF600 system planning 4.4 Environmental conditions for transponders/tags SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 73 REVIEW 4.4 Environmental conditions for transponders/tags Basic rules The transponder/tag must not be placed directly on metal surfaces or on containers of liquid. For physical reasons, a minimum distance must be maintained between the tag antenna and conductive material. A minimum distance of 5 cm is recommended. The tag operates better when the d

  • Siemens Simatic RF600, SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 29 REVIEW System overview of SIMATIC RF600 3 SIMATIC RF600 is an identification system that operates in the UHF range. UHF technology supports large write/read distances with passive transponders. The SIMATIC RF650R or RF680R readers (write/read devices), fitted for example on the gates of a warehouse, automatically record every movement of goods, and signal these to the higher-level systems. The data is filtered and compressed there by data

  • Siemens Simatic RF600, Readers 5.8 RF685R reader SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 239 REVIEW 6GT2811-6CA10-xAA0 Frequencies ETSI frequencies European frequency band ETSI EN 302 208 V1.4.1 (valid since October 23, 2012, publication in the Official Journal of the European Union) 865,7 ... 867.5 MHz (4 channels at max. 2 W ERP) FCC frequencies Frequency band USA 902 ... 928 MHz (50 channels at max. 4 W EIRP, frequency hopping) CMIIT frequencies Frequency band China 920,625 ... 924.375

  • Siemens Simatic RF600, Readers 5.2 RF620R reader SIMATIC RF600 92 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW For more detailed information on the flash codes of the reader see section Error messages and flash codes for RF620R/RF630R (Page 469) Note LED not lit yellow? If the LED does not light up yellow even though a tag is located within the field, common causes are: • Incorrect configuration in the init_run command, or init_run command was not executed (see "Configuration Manual RF620R/RF630R") • Parameter assignment is incorrect (black list, RSSI threshold) • Antenna is switched off • A tag

  • Siemens Simatic RF600, Readers 5.8 RF685R reader SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 229 REVIEW Radiation diagram (Azimuth section) Vertical component of the polarization direction of the antenna Horizontal component of the polarization direction of the antenna Right circular component of the polarization direction of the antenna Figure 5-56 Azimuth section

  • Siemens Simatic RF600, Readers 5.5 RF650R reader SIMATIC RF600 176 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW 5.5.7.2 IC-FCB information Siemens SIMATIC RF650R (FCC): 6GT2811-6AB20-1AA0 IC: This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d`Industrie Canada

  • Readers 5.2 RF620R reader SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 105 REVIEW Technical and electrical characteristics Power supply • Permitted range 21.6 to 30 VDC 1 Power supply Current consumption (in standby mode, no transmit power) Power consumption (in standby mode, no transmit power) 20 V input voltage on the reader, typical

  • Antennas 6.2 RF620A antenna SIMATIC RF600 254 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW 6.2.8 Alignment of transponders to the antenna Polarization axis Since the RF620A antenna has linear polarization, it is necessary to consider the alignment of the transponders with regard to the polarization axis of the antenna. The polarization axes of ant

  • Siemens Simatic RF600, Antennas 6.2 RF620A antenna SIMATIC RF600 272 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW Table 6- 15 6GT2812-1EA01 Standard Federal Communications Commission FCC CFR 47, Part 15 sections 15.247 Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. The FCC approval is granted in association with the FCC approval of the following RF60

  • Siemens Simatic RF600, Readers 5.2 RF620R reader SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 111 REVIEW Table 5- 8 6GT2811-5BA00-2AA1 Standard CMIIT Certification China radio approval Marking on the reader: CMIIT ID: 2012DJ2916 5.2.7.2 FCC information Siemens SIMATIC RF620R (FCC): 6GT2811-5BA00-1AA0, 6GT2811-5BA00-1AA1 FCC ID: NXW-RF620R (for 6GT2811-5BA00-1AA0) FCC ID: NXW-RF600R (for 6GT2811-5BA00-1AA1) This device complies with part 15 of the FCC rules. Operation is subject to the following two condition

  • Siemens Simatic RF600, Antennas 6.3 Antenna RF640A SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 275 REVIEW Antenna Mounting Kit The Antenna Mounting Kit allows the fine adjustment of the antenna field by setting the solid angle (see "RF600 System Manual", chapter "Antennas" > "Mounting types"). 6.3.4 Connecting an antenna to the reader The SIMATIC RF640A antenna must be connected to the reader using an antenna cable. Preassembled standard cables in lengths of 3 m, 10 m, and 20 m are available for the connect

  • Siemens Simatic RF600, Readers 5.5 RF650R reader SIMATIC RF600 170 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW Mounting/installing the device You can mount the reader in two different ways: ● Via a standardized VESA 100 mounting system using the Antenna Mounting Kit (refer to the section Mounting with antenna mounting kit (Page 331)). Tighten the M4 screws on the rear of the reader using a maximum torque of ≤ 1.3 Nm. ● Directly on a flat surface. The positions of the mounting holes for the device are shown in the section Dimension drawing (Page 173). 5.5.4 Configur

  • Siemens Simatic RF600, Readers 5.2 RF620R reader SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 109 REVIEW 5.2.7 Certificates and approvals Note Marking on the readers according to specific approval The certificates and approvals listed here apply only if the corresponding mark is found on the readers. Table 5- 6 6GT2811-5BA00-0AA0, 6GT2811-5BA00-0AA1 Certificate Description Conformity with R&TTE directive TA-2012/548 South Africa radio approval: Radio Equipment Type Approval 5.2.7.1 Country-specific certifications Table 5- 7

  • Siemens Simatic RF600, Readers 5.5 RF650R reader SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 169 REVIEW 5.5.2 Planning operation 5.5.2.1 Antenna/read point configurations You can connect up to four external antennas to the RF650R reader. The standard setting is that four antennas are connected when the reader is started. When connecting multiple antennas, note the information in the section "Specified minimum and maximum spacing of antennas (Page 49)". With the graphical user interface of the integrated Web server, y

  • Antennas 6.1 Overview SIMATIC RF600 246 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW Table 6- 2 Characteristics of the RF640A and RF642A antennas Characteristics RF640A antenna RF642A antenna Material PA 12, silicon-free Frequency band 865-868 MHz 902-928 MHz 865-868 MHz 902-928 MHz Impedance 50 Ohm nominal Antenna gain 4 dBi (7

  • Siemens Simatic RF600, Antennas 6.3 Antenna RF640A SIMATIC RF600 276 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW 6.3.4.1 Bending radii and bending cycles of the cable Cable designation Order No. Length [m] Cable loss [dB] Bending radius [mm] Bending cycle RF640A antenna connection Fixed connection to antenna 0.3 - 15 1 Mal Antenna cable 6GT2815- 0BH30 3 1 51 1 Mal Antenna cable (suitable for drag chains) 6GT2815- 2BH50 5 1,25 48 1) Antenna cable 6GT2815- 1BN10 10 2 77 1 Mal Antenna cable 6GT2815- 0BN10 10 4 51 1 Mal Antenna cable (suitable for drag chains) 6GT2815- 0BN20 15 4 24 1) Antenna ca

  • Siemens Simatic RF600, Readers 5.4 RF640R reader SIMATIC RF600 140 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW Ground connection (a) Hexagon-head screw (b) Plain washer (c) Cable lug (d) Contact washer: Use contact washers according to the Siemens standard SN 70093-6-FSt-flNnnc- 480h for ground connection, Siemens item No.: H70093-A60-Z3 5.4.2 Planning the use 5.4.2.1 Selecting the antenna With the SIMATIC RF640R, there are two ways of using the antenna that are mutually exclusive: ● Either you use the

  • Readers 5.2 RF620R reader SIMATIC RF600 94 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW 5.2.1.5 Grounding connection The RF620R can be electrically connected to the ground potential through a contact washer. The tightening torque must be increased in this case to ensure that electrical contact is made (2.7 Nm). Ground connection (a) Hexagon-head scr

  • Siemens Simatic RF600, Antennas 6.4 Antenna RF642A SIMATIC RF600 298 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW Antenna Mounting Kit The Antenna Mounting Kit allows the fine adjustment of the antenna field by setting the solid angle (see "RF600 System Manual", chapter "Antennas" > "Mounting types"). 6.4.4 Connecting an antenna to the reader The SIMATIC RF642A antenna must be connected to the reader using an antenna cable. Preassembled standard cables in lengths of 3 m, 10 m, and 20 m are available for the connection. The range of the antenna is limited by the cable loss. The maximum range can be achie

  • Siemens Simatic RF600, RF600 system planning 4.3 Antenna configurations SIMATIC RF600 60 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW Calculation of the radiated power with consideration of the cable loss a k If the transmitted power is not applied directly but via a cable with loss a K , this loss should be compensated such that the same radiated power is obtained. If the loss is not appropriately compensated, the radiated power is too small. General preliminary information on the unit "dB" Requirements This section provides you with information on the unit "decibel". This knowledge is a requirem

  • Siemens Simatic RF600, Readers 5.7 RF680R reader SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 201 REVIEW Wiring diagram M12 connector (cable end) You will need to assemble your reader cable with a suitable connector that fits the interface shown above. Keep to the following wiring diagram: Figure 5-40 M12 connector wiring diagram 5.7.1.5 Connection scheme for the digital I/O interface Connection possibilities You can connect the RF680R reader in different ways. In general, the outputs and inputs should be connected as follows: Output Outport (0), (1), (2), (3) ● Each output is rated for 0.5 A current

  • Siemens Simatic RF600, Readers 5.7 RF680R reader SIMATIC RF600 198 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW 5.7 RF680R reader 5.7.1 Description 5.7.1.1 Overview The SIMATIC RF680R is a stationary reader in the UHF frequency band without an integrated antenna. Up to four external UHF RFID antennas can be connected via TNC reverse connections. The maximum RF power output is 2000°W at the reader output. A radiant power of up to 2000 mW ERP is achieved when the appropriate antennas and antenna cables are used. The interfaces (Ethernet, M12 power supply, M12 digital I/O interface) are located along the narrow lower front

  • Siemens Simatic RF600, Readers 5.6 RF670R reader SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 177 REVIEW 5.6 RF670R reader 5.6.1 Description 5.6.1.1 Overview The SIMATIC RF670R is a stationary reader in the UHF frequency band without an integrated antenna. Up to four external UHF RFID antennas can be connected via TNC reverse connections. The maximum RF power output is 1000°mW at the reader output. A radiant power of up to 2000 mW ERP is achieved when the appropriate antennas and antenna cables are used. The interfa

  • Siemens Simatic RF600, Readers 5.6 RF670R reader SIMATIC RF600 184 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW Alternative connection possibilities: ● Pin 1 GND to Pin 3 DO Common ● Pin 2 (VCC) to busbar outputs Voltage infeed through external source Figure 5-36 Example circuit 5: Digital outputs Voltage infeed through an external source is shown here for 12°V by way of example. Other voltages are also permissible.

Related Products and Documents (Rfid Systems):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Weston 16-0201-W Manual  weston/16-0201-w-H45.pdf 11 Oct 2023 6
2 AEG HK953400FB Operation & user’s manual aeg/hk953400fb-7P8.pdf 15 Oct 2022 24 3.94 Mb
3 Electrolux EWS 106210 W Operation & user’s manual electrolux/ews-106210-w-81F.pdf 17 Feb 2023 28 2.48 Mb
4 Dyson Dc45 Operating manual dyson/dc45-QY7.pdf 14 Jun 2023 60
5 GridConnect GC-ATC-2000 Operation & user’s manual gridconnect/gc-atc-2000-47O.pdf 04 Feb 2024 6
6 Sailor 250 FleetBroadband Operation & user’s manual sailor/250-fleetbroadband-2X7.pdf 04 Oct 2022 288

Similar Resources:

  • Alien

    ALR-F800

    (6 pages)
    ALR-F800 Wi-Fi Setup APN-1046 Alien ALR-F800 readers support network connections using an optional Wi-Fi USB adapter. The following application note contains detailed instructions on how to configure the reader in order to establish a Wi-Fi connection. Minimum Reader Firmware Requirements  reader fir …
  • impinj

    R705

    (13 pages)
    Impinj R705 Portal Gateway Reader Installation and Operations Guide Version 0.1 1 Impinj R705 Portal Gateway Reader Installation and Operations Guide Version 0.2 Copyright © 2012 - 2020 Impinj, Inc. All rights reserved http://www.impinj.com Impinj, Octane, Speedway, xSpan and xArray are either registered trademarks or trademarks of Impinj, …
  • Agrident

    AIR200

    (11 pages)
    Agrident GmbH, Steinklippenstr. 10, D-30890 Barsinghausen Phone +49 5105 520614 - Fax +49 5105 520616 AIR200 Installation V10/07/06 …
  • Feig Electronic

    ID ISC.LRU1000

    (21 pages)
    OBID®RFID by FEIG ELECTRONIC06.10.2006advanced reader technologiesOBID i-scan® UHF1Getting Startedwith ID ISC.LR(M)U1000/2000UHF-ReaderFEIG ELECTRONIC GmbH,Lange Strasse 4, D-35781 Weilburg(tel) +49 (0) 6471 3109 0, (fax) +49 (0) 6471 3109 99(web) http://www.feig.de(email) [email protected]
  • Siemens

    SIMATIC RF1000 Series

    (77 pages)
    SIMATIC RF1000 SIMATIC Ident RFID systems SIMATIC RF1000 Operating Instructions 02/2020 C79000-G8976-C432-07 Introduction 1 Description 2 Installation 3 Connecting 4 Commissioning 5 Programming 6 The demo application 7 Technical specifications 8 Dimension drawing 9 Appendix A Service & Support B …
  • RF Code

    Scorpion I

    (15 pages)
    Scorpion I Reader User’s GuideRF Code, Inc. Publication: 03801674-01Issue Date Comment RevisionNovember 8, 2001 Initial Release 00is the trademark of RF Code, Inc.1250 South Clearview Ave. Mesa, AZ 85208 (480) 969-2828 www.rfcode.com Copyright 2001 RF Code, Inc. All Rights Reserved …

Comments, Questions and Opinions: