  • Siemens FST020, Maintenance and diagnostics 4.1 Identification FST020 Function manual Function Manual, 09/2017, A5E42949526-AA 125 4.1.15 System type Description System type Setting SITRANS FUS; SITRANS FUH Default SITRANS FUS Related Path Maintenance and diagnostics → Identification → System type 4.1.16 Transmitter electronics 4.1.16.1 HW version Displays version number corresponding to electronics hardware of device. Setting Default Related Path Maintenance and diagnostics → Identification → HW version 4.1.16.2 FW version Displays version number co

  • Siemens FST020, Maintenance and diagnostics 4.2 Diagnostic events FST020 Function manual 130 Function Manual, 09/2017, A5E42949526-AA Setting Auto; Manual Default Auto Path Maintenance and diagnostics → Diagnostic events → Acknowledge mode 4.2.5 Transmitter detailed events (read only) Description Transmitter Detail Alarms menu is only visible in case an alarm with detailed alarm information is pending. Setting • DE10 Failed to read any data related page • DE11 Failed to read FATAL_ERROR_PAGE from • DE12 Failed to read SHUT_DOWN_PAGE from • DE21 The EEPROM data is inconsi

  • Siemens FST020, Security 6.8 Auto logout FST020 Function manual Function Manual, 09/2017, A5E42949526-AA 183 parameter is set to On, you will be prompted to enter the password before each HMI operation. 6.8 Auto logout Description The Auto logout function can be be configured. When the parameter is set to Off (default), you will not be prompted for password for 10 minutes after the last key press. When the parameter is set to On, you will be prompted to enter the password before each HMI operation. Setting Of

  • Siemens FST020, Setup 3.2 Process values FST020 Function manual 50 Function Manual, 09/2017, A5E42949526-AA 3.2.4.5.5 Hysteresis Description Sets the hysteresis for alarm and warning limits. The hysteresis is the distance between the limits for activation and deactivation of an alarm/warning. Setting 0 m/s to +9999997952 m/s Default 0.00 m/s Related Path Setup → Process values → Sound velocity → Alarm and warning limits → Hysteresis 3.2.5 Density 3.2.5.1 Units Description

  • Siemens FST020, FST020 Function manual Function Manual, 09/2017, A5E42949526-AA 121 Maintenance and diagnostics 4 4.1 Identification 4.1.1 Long tag Sets a unique tag name for device. Limited to 32 characters. Setting User-configurable Default --------------------------------; 32 characters (A, B, C, ... X, Y, Z, /, 1, 2, 3, ... 7, 8, 9) Related Path Maintenance and diagnostics → Identification → Long tag 4.1.2 Tag Sets a unique short tag name for device or measurement point. Limited to 8 characters. Setting User-configurable Default --------------------------------; characters (A, B, C, ... X, Y, Z, /, 1, 2, 3, ... 7,

  • Siemens FST020, Setup 3.4 Inputs and outputs FST020 Function manual Function Manual, 09/2017, A5E42949526-AA 63 ● Medium temperature ● Kinematic viscosity All process values are available for analog output channel 2 and frequency output channel 4. The accuracy specified for the analog output signal applies only within the range 4 to 20 mA. Lower limit (4 mA) and upper limit (20 mA) can be assigned to any specific flow values. ① Linear control range ② Lower saturation limit ③ Upper saturation limit ④ Lower fault current value ⑤ Recomm

  • Siemens FST020, Setup 3.11 View 4 FST020 Function manual Function Manual, 09/2017, A5E42949526-AA 105 3.10.13 Trend scale upper limit Description The Trend Scale Upper Limit defines the scaling upper limit of the value axis for the fixed mode. Setting options Default setting 0 Related This parameter is only available if Trend Scale Mode is set to Fixed. Path Setup → Display → View 3 → Trend Scale Upper Limit 3.11 View 4 3.11.1 Enable or disable Description In this parameter View 4 can be enabled. Setting Disabled; Enabled Default

  • Siemens FST020, Setup 3.3 Totalizers FST020 Function manual 58 Function Manual, 09/2017, A5E42949526-AA 3.3.1.2 Units Description Select units for displayed Totalizer 1. The set of units depends on the selected process value. Units are not applied at communication interface. Setting Process value = Mass flow: g (grams); kg (kilograms); t (1 t = 1000 kg); STon (1 STon = 2000 lb); T (1 T = 2240 lb); oz (ounces); lb (pounds); Process value = Volume flow: l (li- ters); hl (hectoliters); m³ (cubic meters); gal (US gallons); i.gal (Imperial gallons); BBL31.5 (

  • Siemens FST020, Setup 3.3 Totalizers FST020 Function manual Function Manual, 09/2017, A5E42949526-AA 61 Setting Process value = Mass flow: -9999997952 kg to +9999997952 kg Process value = Volume flow: -9999997952 m³ to +9999997952 m³ Default Process value = Mass flow: +9999997952 kg Process value = Volume flow: +9999997952 m³ Related Path Setup → Totalizers → Totalizer 1 → Alarm and warning limits → Upper warning limit 3.3.1.10.3 Lower warning limit Description Warning is tri

  • Siemens FST020, FST020 Function manual Function Manual, 09/2017, A5E42949526-AA 185 Language 7 7.1 Language Description Select the local display language. Setting English; Deutsch Default English Related Language Language

  • Siemens FST020, Setup 3.1 Sensor settings FST020 Function manual 30 Function Manual, 09/2017, A5E42949526-AA Related Path Setup → Sensor settings → Path settings → Path 1 → Path geometry 3.1.7.2.3 Sensor spacing Description Sensor spacing - Distance between the front faces of the sensors for path 1. Setting -100.0 m to 100.0 m Default 0.0 m Related Path Setup → Sensor settings → Path settings → Path 1 → Sensor spacing 3.1.7.2.4 Zero point adjustment Description Zero point adjustment. Can only be changed

  • Siemens FST020, Setup 3.4 Inputs and outputs FST020 Function manual 74 Function Manual, 09/2017, A5E42949526-AA 3.4.3.4.9 Fail-safe minimum time Description Minimum time the output stays in fail-safe mode. Setting 0 s to 100 s Default 0 s Related Path Setup → Inputs and outputs → Channel 2 - output → Current output → Fail-safe minimum time 3.4.2.5 Off delay Description Set the time delay between resetting alarm condition and de-activating the output. Setting 0.0 s to 100.0 s Default 0.0 s Related Path Setup → Inputs and outputs → Channel 2 - output → Status output → Off delay 3.4.3 Channel 3 - relay 3.4.3.1 Operation mode

  • Siemens FST020, Setup 3.4 Inputs and outputs FST020 Function manual Function Manual, 09/2017, A5E42949526-AA 87 3.4.3.4.10 Fail-safe behaviour Description Current output reaction in case of a fault. Setting Last valid value; Hold; Current value; Fail-safe value Default Last valid value Related Path Setup → Inputs and outputs → Channel 4 - input/output → Pulse output → Fail safe behav- iour 3.4.3.4.11 Fail-safe value Description Output value in case of a fault and when fail-safe behaviour configured to Fail-safe value. Setting 0.0 pulses/s to 12500.0 pulses/s Default 1.0 pulses/s Related Path Setup → Inputs and outputs → Channel

  • Siemens FST020, Setup 3.13 View 6 FST020 Function manual Function Manual, 09/2017, A5E42949526-AA 115 3.13.2 View Description The display View 6 can be configured. Setting Single value; Three values; Totalizer; Dosing; 1 value and bargraph; 1 value and graph; Six values; Six diagnostic values; Alarm list Default Alarm list Related If Single Value or Dosing is selected, 1st Process Value must be configured. If Three Values is selected, 1st Process Value , 2nd Process Value and 3rd Process Value mu

  • Maintenance and diagnostics 4.2 Diagnostic events FST020 Function manual Function Manual, 09/2017, A5E42949526-AA 131 4.2.7 Enable alarms 4.2.7.1 Sensor events (1) Description Various sensor alarms can be enabled to show in the display and on the output if they occur. Setting 05 DSL voltages; 06 DSL storage; 07 Flow measurement; 08 DSL

  • Siemens FST020, FST020 Function manual Function Manual, 09/2017, A5E42949526-AA 19 Setup 3 3.1 Sensor settings 3.1.1 Length unit Description Unit for length values. 3.1.2 Length unit - settings Setting ft; m; in; cm; mm Default m Related Path Setup → Sensor settings → Length units 3.1.3 Pipe settings 3.1.3.1 Pipe class Description Pipe class - Read only. Can only be changed via the Sensor Wizard. Indicates the pipe class chosen from the pipe data library included in the sensor setup wizard. 3.1.3.2 P

  • Siemens FST020, Setup 3.4 Inputs and outputs FST020 Function manual 82 Function Manual, 09/2017, A5E42949526-AA 3.4.3.3.3 Frequency value high Description Upper frequency value. Upper nominal output range boundary. Setting 0.0 Hz to 12500.0 Hz Default 10000.0 Hz Related Path Setup → Inputs and outputs → Channel 4 - input/output → Frequency output → Frequency value high 3.4.3.3.4 Frequency value low Description Lower frequency value. Lower nominal output range boundary. Setting 0.0 Hz to 12500.0 Hz Default 0.0 Hz Related Path Setup → Inputs and outputs �

  • Siemens FST020, Setup 3.8 View 1 FST020 Function manual Function Manual, 09/2017, A5E42949526-AA 95 3.8.9 Trend scale mode Description The Trend scale mode can be selected with automatic scaling or fixed scaling. Setting Auto; Fixed Default Auto Related This parameter is only available if View is set to 1 value and graph. If Fixed is selected, Trend scale lower limit and Trend scale upper limit must be configured. Path Setup → Local display → View 1 → Trend scale mode 3.8.10 Trend log time window Description The Trend log time window logging period (time axis length) can be selected. Setting 1 minute; 5 minutes; 15 minutes; 30 minutes; 1

  • Setup 3.10 View 3 FST020 Function manual 100 Function Manual, 09/2017, A5E42949526-AA 3.9.11 Trend scale lower limit Description The Trend Scale Lower Limit defines the scaling lower limit of the value axis for the fixed mode. Setting Default 0 Related This parameter is only available if Trend Scale Mode is set to Fixed. Path Setup → Display �

  • Setup 3.11 View 4 FST020 Function manual 108 Function Manual, 09/2017, A5E42949526-AA 3.11.7 5th value Description The display 5th Process Value can be selected. Setting Transmitter internal temperature; Reynolds number; RxGain up path 1; RxGain down path 1; SNR up path 1; SNR down path 1; Sound velocity path 1; Flow velocity path 1; Delta time pat

  • Siemens FST020, Maintenance and diagnostics 4.3 Maintenance FST020 Function manual 140 Function Manual, 09/2017, A5E42949526-AA 4.3.3.3 I/O cassette 4.3.3.3.1 FW version (expert) Description Only Siemens authorized personnel may replace spare parts. Setting Cancel; OK Default Cancel Path Maintenance and diagnostics → Maintenance → Electronic part identification → I/O cassette → FW version 4.3.3.3.2 Serial number (expert) Description Only Siemens authorized personnel may replace

  • Siemens FST020, Maintenance and diagnostics 4.2 Diagnostic events FST020 Function manual 132 Function Manual, 09/2017, A5E42949526-AA Setting 228 Sound velocity above alarm limit; 229 Sound velocity above warning limit; 230 Sound velocity below warning limit; 231 Sound velocity below alarm limit; 232 Flow velocity above alarm limit; 233 Flow velocity above warning limit; 234 Flow velocity below warning limit; 235 Flow velocity below alarm limit; 244 Kin. viscosity above alarm limit; 245 Kin. viscosity above warning limit; 246 Kin. viscosity

  • Siemens FST020, Setup 3.2 Process values FST020 Function manual 54 Function Manual, 09/2017, A5E42949526-AA 3.2.6.3.2 Upper warning limit Description If process value exceeds this limit a warning is triggered. Setting -9999997952 m²/s to +9999997952 m²/s Default +9999997952 m²/s Related Path Setup → Process values → Kinematic viscosity → Alarm and warning limits → Upper warning limit 3.2.6.3.3 Lower warning limit Description If process value falls below this limit a warning is triggered. Setting -9999997952 m²/s to +9999997952 m²/s Default -9999997952 m²/s Related Path Setup → Process values → Kinematic viscosity

  • Siemens FST020, Setup 3.1 Sensor settings FST020 Function manual Function Manual, 09/2017, A5E42949526-AA 21 Setting 200.0 m/s to 4000.0 m/s Default 3000.0 m/s Related Path Setup → Sensor settings → Pipe settings → Wall sound velocity 3.1.3.7 Liner settings 3.1.3.7.1 Liner thickness Description Pipe liner thickness Setting 0.0 m to 0.5 m Default 0.0 m Related Path Setup → Sensor settings → Pipe settings → Liner settings → Liner thickness 3.1.3.7.2 Liner material Description Liner material - Read only. Can only be changed via the Sensor Wizard. Setting Re

  • Setup 3.14 Status icons FST020 Function manual 118 Function Manual, 09/2017, A5E42949526-AA Related This parameter is only available if View is set to Totalizer or 1 Value and Graph. Path Setup → Display → View 6 → Trend log time window 3.13.11 Trend scale lower limit Description The Trend Scale Lower Limit defines the scaling l

  • Setup 3.13 View 6 FST020 Function manual 116 Function Manual, 09/2017, A5E42949526-AA Related This parameter is only available if View is set to Three Values, Six Values or Six Diagnostic Values. Path Setup → Display → View 6 → 2nd Process Value 3.13.5 3rd process value Description The display 3rd Process Value can be selected. Setting Mass flow; Vol

  • Siemens FST020, Setup 3.1 Sensor settings FST020 Function manual Function Manual, 09/2017, A5E42949526-AA 25 3.1.5.4 Kinematic viscosity Description Viscosity of media used for compensation. Input during setup. Setting 0.00 m²/s to 5000.0 m²/s Default 0.000001 m²/s Related Path Setup → Sensor settings → Medium characteristics → Kinematic viscosity 3.1.5.5 Process density Description Density of media used for compensation. Input during setup. Setting 0.0 kg/m³ to 2000.0 kg/m³ Default 1000.0 kg/m³ Related Path Setup → Sensor settings → Medium c

Related Products and Documents (Measuring Instruments):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sharp DV-SV97S(U) Operation manual sharp/dv-sv97s-u-3MV.pdf 11 Jul 2022 43 4.07 Mb
2 Panasonic KX-TCD820FX Operating instructions manual panasonic/kx-tcd820fx-BKU.pdf 13 Oct 2022 76 4.69 Mb
3 Weed Eater 530087060 Operator's manual weed-eater/530087060-O6W.pdf 27 Jul 2023 6 0.21 Mb
4 Logic Controls LC8200 Specifications logic-controls/lc8200-EIR.pdf 17 Jun 2023 1
5 Samsung SPF-75H/76H/85H/86H Specification samsung/spf-75h-76h-85h-86h-669.pdf 17 Oct 2023 6 1.47 Mb
6 Pullman Holt 45 HEPA Supplementary manual pullman-holt/45-hepa-788.pdf 27 Jun 2023 1

Similar Resources:

  • Klein Tools

    CL320

    (18 pages)
    INSTRUCTION MANUALENGLISH400A AC Auto-Ranging Digital Clamp MeterTrue RMSMeasurement Technology600V400A40MΩ• NON-CONTACTVOLTAGE TESTING• AUTO-RANGING• DATA HOLD• RANGE HOLD• TEMPERATURE• AUDIBLE CONTINUITY50017482m-40° –1832°F-40° –1000°CCL320INSTRUCTION MANUAL400A AC Auto-Ranging Digital Clamp MeterTrue RMSMeasurement VOLTAGE TESTING …
  • Axis Industries

    QALCOSONIC HEAT 1

    (33 pages)
    AB “AXIS INDUSTRIES” ULTRASONIC METER FOR HEATING AND COOLING QALCOSONIC HEAT 1 TECHNICAL DESCRIPTION, INSTALLATION AND USER INSTRUCTIONS PEQALCOheat1V01 KAUNAS …
  • JONARD TOOLS

    FPM-55

    (2 pages)
    FPM-55OPTICAL POWER METER W/ STORAGEINSTRUCTION MANUALUnit will not turn on Faint display on the LCD screen1. Power is OFF2. The battery power is too low1. Turn the device ON by pressing the Power Key2. Replace the batteriesInaccurate Measurements 1. Optical connector is not clean2. Incorrect fiber connection1. Clean the optical connectors with contact clean …
  • janitza

    UMG 511

    (104 pages)
    Dok Nr. 1.037.029.3.h from firmware rel. 2.0 / hardware rel. 20Power Quality AnalyserUMG 511Installation and commissioningArticle no. 33.03.089Janitza electronics GmbHVor dem Polstück 6D-35633 LahnauSupport Tel. +49 6441 9642-22Fax +49 6441 9642-30e-mail: [email protected]: http://www.janitza.comwww.janitza.com …
  • Klein Tools

    CL700

    (16 pages)
    INSTRUCTION MANUALENGLISHCL700SELECT:InstructionsPackagingFRANÇAIS pg. 33ESPAÑOL pg. 17600A AC Auto-Ranging Digital Clamp Meter1000V600A60MΩTrue RMSMeasurement Technology600A AC Auto-Ranging Digital Clamp MeterTrue RMSMeasurement Technology• NON-CONTACTVOLTAGE METER• LOW IMPEDANCE• DATA & RANGEHOLD• AUDIBLE CONTINUITY• DIODE TEST• CAPAC …
  • Powerfix Profi

    KH 2927-2

    (73 pages)
    MULTI-FUNCTION DETECTOR KH 2927-2MULTIFUNKČNÍDETEKTORNávod k obsluzeMULTIFUNKČNÝDETEKTORNávod na obsluhuMULTIFUNKCIJSKIDETEKTORNavodila za uporaboMULTIFUNKCIÓSDETEKTORHasználati utasításWIELOFUNKCYJNYDETEKTORInstrukcja obsługiIAN 77287MULTI-FUNCTIONDETECTOROperating instructions4 MULTIFUNKTIONS-DETEKTORBedienungsanleitung …

Comments, Questions and Opinions: