  • Siemens 6SR41 series, Application Specific Features 7.9 Communication Interfaces Product User Manual 170 Operating Instructions, Version AE 12/2009, A5E01454341C 7.9 Communication Interfaces 7.9.1 Available Networks At present, the NXG control supports the following industry standard PLC networks: ● Modbus RTU ● Modbus Ethernet ● Profibus DP ● ControlNet ● DeviceNet ● Modbus Plus Note Note: Modbus RTU or Modbus Ethernet is available as Network 1 without additional hardware. Other

  • Theory 3.2 The Power Circuitry Product User Manual Operating Instructions, Version AE 12/2009, A5E01454341C 39 Note The phase shift of the carrier signals between phases is determined by the number of cells in the system, the equation being Phase shift = 180 degrees / total number of cells. In this case (3 ranks or 9 cells), the carrier signal phase

  • Siemens 6SR41 series, Product Description 5.3 Cabinet Details Product User Manual 76 Operating Instructions, Version AE 12/2009, A5E01454341C * Shown with full population of electrolytic capacitors Figure 5-15 GenIV Cell, 40-140 Amp, Anatomy The GenIV cells use an uncontrolled diode rectifier to convert the three-phase secondary voltage to DC. Since power can only flow from the transformer to the cells, the converter is considered a two quadrant type (2Q). Figure 5-16 GenIV Cell, 40-140 Amp, Heat Sink Cell Data Switching Frequency

  • Siemens 6SR41 series, Product Description 5.3 Cabinet Details Product User Manual 96 Operating Instructions, Version AE 12/2009, A5E01454341C Note Never energize the drive without operational blowers providing air flow. The drive contains components that have losses in the IDLE state. Without air flow, these losses may heat up components and eventually damage the drive over time. Applying Medium Voltage without air flow will result in a trip from the Coordinated Input Protection Scheme.

  • Siemens 6SR41 series, Overview 2.3 Perfect Harmony Features Product User Manual Operating Instructions, Version AE 12/2009, A5E01454341C 27 ● Control confirms firing from: – Output voltage divider – Output Hall Effect current transducer ● No two cells ever switch at the same time ● Cell switching rate is low compared to effective switching frequency of VFD: – Typically 600 Hz carrier frequency per pole, results in 1200 Hz switching frequency per cell ● VFD effective switching frequency is simply the cell switchi

  • Product Description 5.2 Cabinet Outlines Product User Manual Operating Instructions, Version AE 12/2009, A5E01454341C 57 H p 1 Voltage Losses (kW) 2 Ventilation 3 Footprint 4 Weight (lbs) 5 1 0 0 0 6600 26.25 9530 1 2 5 0 6600 32.75 11225 1 5 0 0 6600 39.50 11575 1 7 5 0 6600 45.75 13275 2 0 0 0 6600 52.50 6250 CFM @ 1.62 ´´ H 2 O (80 �

  • Siemens 6SR41 series, Application and Operation 6.16 Dual Frequency Braking Product User Manual 154 Operating Instructions, Version AE 12/2009, A5E01454341C ● Rated HP ● Rated Voltage ● Rated Frequency ● Full/Half load speed ● Full/Half load efficiency ● Locked Rotor Torque and Current ● Pull out torque ● Critical frequencies of the mechanical system

  • Siemens 6SR41 series, Product Description 5.3 Cabinet Details Product User Manual Operating Instructions, Version AE 12/2009, A5E01454341C 87 Coordinated Input Protection Scheme Input currents and voltages to the drive input transformer are measured and processed continuously by the control system. Information such as efficiency, power factor, and harmonics are available to the user. The input monitoring also protects against transformer secondary side faults that cannot be seen by typical primary protection relaying. Thus it is very important that the drive input medium switchgear, if not supplied as standard, is interlocked to the control system so that input medium vol

  • Siemens 6SR41 series, Appendix B.1 Reader Comments Form Product User Manual 180 Operating Instructions, Version AE 12/2009, A5E01454341C Additional Comments Thank you for your comments. Please mail, fax or e-mail your comments to: Attention: Documentation Control Siemens LD A 500 Hunt Valley Road New Kensington, PA 15068 USA Phone: (724) 339-9500 Fax: (724) 339-9562 E-mail: [email protected]

  • Application and Operation 6.9 User IO Product User Manual Operating Instructions, Version AE 12/2009, A5E01454341C 131 6.9 User IO The VFD provides terminal strips as required for end-user connection of isolated analog and digital input/output signals to the drive. Specific I/O implementation is customized for each drive where the end user must refer t

  • Siemens 6SR41 series, Product Description 5.3 Cabinet Details Product User Manual 68 Operating Instructions, Version AE 12/2009, A5E01454341C 3ULPDU\ FDEOHV 3ULPDU\ &RQQHFWLRQV +++ 6HFRQGDU\ ZLUHURXWLQJ WRFHOOVHFWLRQ 7KHUPDO VZLWFK KDUQHVV 3ULPDU\/LQH9DULDWLRQ7DSV  VHWSHUSKDVH %RWWRP$FFHVV ,2SODWH $ LU'HIOHFWRU *URXQGSDG &SKDVHVHFRQGDU\IXVHEORFN IXVHVSHUFHOOIXVHVSHUSKDVH Figure 5-8 Typical GenIV 4160V, 200-260 A Transf

  • Siemens 6SR41 series, Product Description 5.2 Cabinet Outlines Product User Manual 60 Operating Instructions, Version AE 12/2009, A5E01454341C H p 1 Voltage Losses (kW) 2 Ventilation 3 Footprint 4 Weight (lbs) 5 5 5 0 0 10000 144.25 TBD 6 0 0 0 10000 157.25 TBD 1. Drive Rated Hp 2. Losses are shown as 2.59 kW per 100 Hp, rounded up to the nearest ¼ value 3. EC Blower operates at 80% speed typically (100% speed with Duct Interface) 4. Subject to change without notice 5. 6. 7. For 4160 V, 40-140 A add 160 lbs for redundant blower and 75 lbs for cell bypass For 4160 V, 200-260 A add 200 lbs for redun

  • Siemens 6SR41 series, Abbreviations Product User Manual 176 Operating Instructions, Version AE 12/2009, A5E01454341C Abbreviation Meaning NXG Next Generation Control NXG II Next Generation Control II oamp Output Current OLVC Open Loop Vector Control O-M Overmodulation OOS Out of Saturation (IGBT) overld Overload P Proportional (PID) Pa Pascals pb Push Button PC Personal Computer or Printed Circuit PCB Printed Circuit Board PID Proportional Integral Derivative PLC Programmable Logic Controller PLL Phase Locked Loop pot Potentiometer pp Peak-to-peak ppm Parts per Million PPR Pulses per Revolut

  • Siemens 6SR41 series, Product Description 5.3 Cabinet Details Product User Manual 84 Operating Instructions, Version AE 12/2009, A5E01454341C Signal Type Signal Name Function Digital Input IDI-1B SW1-Remote/Auto Digital Input IDI-2B Output Reactor Winding Temperature, High (Else SPARE) Digital Input IDI-3B Output Reactor Winding Temperature, High-High (Else SPARE) Digital Input IDI-0C SPARE Digital Input IDI-1C SPARE Digital Input IDI-2C SPARE Digital Input IDI-3C Transformer Air Flow Tempera

  • Siemens 6SR41 series, Product Description 5.2 Cabinet Outlines Product User Manual Operating Instructions, Version AE 12/2009, A5E01454341C 53 5.2.1 9 cell, 4160 V Output, 200-1100 Hp Figure " GenIV 4160 V Output 200 - 1100 Hp General Arrangement" details the GenIV 4160 V output 200 - 1100 Hp drive, and Figure "GenIV 4160 V Output 200 - 220 Hp, Sectional View" points out each core section. The default color of the enclosure is ASA 61 Gray. 5HPRYDEOHSODWHIRU UHGXQGDQWEORZHU %RWWRP$FFHVV 3ODWHV 7RS$FFHVV 3ODWHV Figure 5-1 GenIV 4160 V Output 200-1100 Hp G

  • Siemens 6SR41 series, Application and Operation 6.8 Drive Tuning Product User Manual 130 Operating Instructions, Version AE 12/2009, A5E01454341C The second stage consists of a scan feature during which a preset level of current of varying frequency is applied to the motor. The control monitors the measured motor flux, and when the motor flux exceeds a programmable flux threshold, the control assumes that the applied frequency is equal to the rotating speed of the motor. Spinning Load should be enabled if any of the following operating modes or features is selected: ● Fast Bypass ● VFD Startup while motor is spinning (forward or reverse)o

  • Siemens 6SR41 series, Glossary Product User Manual 190 Operating Instructions, Version AE 12/2009, A5E01454341C Loss of signal feature The loss of signal feature is a control scheme that gives the operator the ability to select one of three possible actions in the event that the signal from an external sensor, configured to specify the speed demand, is lost. Under this condition, the operator may program the drive (through the system program) to (1) revert to a fixed, pre-programmed speed, (2) maintain the current speed, or (3) perform a controll

  • Product Description 5.2 Cabinet Outlines Product User Manual Operating Instructions, Version AE 12/2009, A5E01454341C 59 H p 1 Voltage Losses (kW) 2 Ventilation 3 Footprint 4 Weight (lbs) 5 1 2 5 0 10000 .32.75 1 5 0 0 10000 39.50 1 7 5 0 10000 45.75 2 0 0 10000 52.50 2 2 5 0 10000 59.00 2 5 0 0 10000 65.50

Related Products and Documents (DC Drives):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Chauvet maverick mk1 spot Operation & user’s manual chauvet/maverick-mk1-spot-W2E.pdf 15 Jul 2023 40
2 WLtoys Q282J spaceship Instruction manual wltoys/q282j-spaceship-JM2.pdf 25 Aug 2023 8
3 AUMA SG 05.1-F05 Operating instructions manual auma/sg-051-f05-DOF.pdf 18 Nov 2022 68
4 Crosley CR6249A Instruction manual crosley/cr6249a-1RS.pdf 10 Dec 2023 30 0.82 Mb
5 Philips HP4885/01 Operation & user’s manual philips/hp4885-01-5D5.pdf 14 Feb 2023 5 1.75 Mb
6 3Com HomeConnect Getting started manual 3com/homeconnect-4H5.pdf 16 Jul 2022 70

Similar Resources:

  • Emerson

    E300 Series

    (490 pages)
    Design GuideE300 Advanced Elevator Drive Model sizes 3 to 7Dedicated Elevator Variable Speed AC drive for induction and permanent magnet motorsPart Number: 0479-0024-01Issue: 1 www.controltechniques.com …
  • Leadshine Technology

    DCS810V2

    (29 pages)
    User’s Manual For DCS810V2 Digital DC Servo Driver Revision 1.0 ©2009 All Rights Reserved Attention: Please read this manual carefully before using the driver! 3/F, Block 2, Nanyou Tianan Industrial Park, Nanshan Dist, Shenzhen, China Tel: (86)755-26434369 Fax: (86)755-26402718 URL: www.leadshine.com E-Mail: [email protected] The content in this man …
  • REED

    5301PDCOMP

    (16 pages)
    11117-553011launaM s’rotarepO evirD rewoP DP1035910-553015301PD Power DriveOPERATOR’S MANUAL REED MANUFACTURING COMPANY1425 West 8th St. P.O. Box 1321, Erie, Pa 16512 USA Phone: 800-666-3691 or 814-452-3691 Fax: 800-456-1697 or 814-455-1697www.reedmfgco.com0416-55301The electric-motor-driven REED 5301PD Power Driv …
  • Allen-Bradley

    Kinetix 5500

    (2 pages)
    Installation InstructionsKinetix 5500 Feedback Connector KitCatalog Number 2198-KITCON-DSLAbout the Feedback Connector KitThis feedback connector kit includes a two-pin connector plug that accepts feedback wires from the 2090-CSxM1DF-xxAAxx single motor cable. You must assemble the bottom half of the connector housing with the connector plug wired and proper …
  • Powtran

    PI9000 series

    (52 pages)
    Service center of POWTRAN technology company My future ,drive and control Quick guide of PI9000 operation 1.The introduction of new generation of PI9000 2. The new generation of PI9000 has following feature . 3. Installation of PI9000 procedure : 4.Connection of peripheral devices. 5.Keyboard operating instruction. 6.Trial operation follow chart 7.Wiring …
  • Canworld

    CDE500 Series

    (284 pages)
    CDE500 Vector Control AC Drive PrefacePrefaceThank you for purchasing CDE500 Vector Control AC Drive developed by Shenzhen CanworldElectrical Technology Co.,Ltd.The CDE500 series AC drive is a general-purpose high-performance vector control AC drive, whichis widely used for simple fan and pump driving, and automatic controlling in specific industryequipment …

Comments, Questions and Opinions: