Siemens FC72x Quick Reference Manual

Siemens FC72x Manual Online:

4.25, 1645 votes
Siemens FC72x User Manual
Siemens FC72x User Guide
Siemens FC72x Online Manual

Text of Siemens FC72x User Guide:

  • Siemens FC72x, Installation C - NET detector line 5 31 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 5.4 C-NET detector line Up to 252 line devices, such as automatic fire detectors, manual call points, transponders, and other C-NET devices can be connected to one C-NET detector line. The C-NET connection is on the periphery board. Depending on the control panel type (2 or 4 loops), 252 or 504 line devices can be operated on a station. Most C-NET line devices, such as fire detectors, are supplied with the operating voltage required directly by the C-NET. An e

  • Siemens FC72x, Commissioning Auto - configuration of control panels 7 50 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 Display for auto-configuration Main menu Exit with <C> Access level 3 Message summary Functions Favorites Topology (1) (2) (3) (4) Element search Event memory Login/logout Settings/administration (5) (6) (7) (8) Function On/Off Function All LED test κ Select 'Topology', continue with <ok> Topology Exit with <C> Access level 3 Detection tree Hardware tree Control tree (1) (2) (3) Function On/Off

  • Siemens FC72x, Comm issioning Changing access authorization PIN 7 55 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 7.6 Changing access authorization PIN After successful commissioning, the 4-digit access authorization (PIN) for the corresponding access level must be changed. Keep the new PIN in a safe place. If the PIN is lost, a system reset must be undertaken to the station's factory setting. The control panel configuration, including all customer data, is cleared in the process. The '0000' PIN set in the factory then applies again after a system reset. 7.6.1 PIN administration You can change an exis

  • Installation Power supply - mains voltage connection 5 21 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 5.2.1 Emergency power supply Should the AC mains voltage fail, the emergency power supply will be provided by the connected batteries with no interruptions. The emergency power bridging time depends on the control panel's quiescent an

  • Siemens FC72x, Commissioning Auto - configuration of control panels 7 48 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 7.2 Auto-configuration of control panels This function requires the control panel, components, and C-NET to have been correctly installed. Once auto-configuration is complete, the control panel is ready for detection with limitations. A fire is recognized by the connected fire detectors and displayed on the control panel. Configuration with the FXS7212 Cerberus Engineering Tool is required in order to assign controls, define individual alarm responses,

  • Siemens FC72x, System overview Station overview 3 14 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 3.1 Station overview FC722 fire control panel (2-loop) FC724 fire control panel (4-loop) FT724 fire terminal Max. C-NET addresses 252 * 504 * ― Without loop extension 2 loops * 4 loops * ― With loop extension 4 loops * 8 loops * ― Supply Power supply 70/150 W 150 W optional (70 W) Batteries (capacity) max. 2x 26 Ah max. 2 x 26 Ah optional (7 Ah) External DC supply 24 V ― ― redundant Operating unit integrated integrated integrated Inputs and outputs RT alarm, relay 1 1 ― RT fault

  • About this document Download center 1 7 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 1.2 Download center You can download various types of documents, such as data sheets, installation instructions, and license texts via the following Internet address: http://siemens.com/bt/download κ Enter the document ID in the 'Find by keyword' inpu

  • Siemens FC72x, Commissioning Displaying C - NET devices 7 52 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 7.3 Displaying C-NET devices After auto-configuration, the individual C-NET detector lines and the associated C- NET devices of each line can be displayed and configured. Depending on the control panel type (2 or 4 loops) and the control panel design, the depiction may vary and several lines may be displayed. You can display the lines and devices as follows. The displays are depicted

  • Siemens FC72x, Legal notice 2 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 Legal notice Technical specifications and availability subject to change without notice. Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved. Issued by: Siemens Switzerland Ltd. Building Technol

  • Siemens FC72x, Installation Hardware components 5 25 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 5.3.3 Monitored outputs for alarm and fault (FT activation) Connection terminals on periphery board (2-loop) of FC722 and/or periphery board (4-loop) of FC724. Permitted cable cross-section: 0.2…1.5 mm 2 . FC722 X6 Designation Description 6 FAU_OUT Output fault 5 VSYS_O Supply output for consumer fault 4 AL_OUT- Alarm output (-) 3 AL_OUT+ Alarm output (+) 2 SOUND1- Output for acoustic signal transmitter (-) 1 SOUND1+ Output for acoustic signal transmitter (+) FC724 X6 Designation Description 4 FAU_OU

  • Siemens FC72x, Installation Hardware components 5 29 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 Example: Principle circuit on I/O 1 (connection 1). I/O 1 as 'input' The input can be triggered with a potential-free, external switching contact. In such cases, the corresponding input is switched to GND. Depending on the programming, a permanent or sensing contact can be connected. The activated input can be used to program one of the station's control functions. I/O 1 as 'output' Configuration as 'output&

  • Siemens FC72x, Installation Power supply - mains voltage connection 5 19 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 5.2 Power supply - mains voltage connection When supplied from the factory, the power supply's internal cabling is already connected. Power units available 24 V DC/2.5 A, power 70 W, max. battery capacity which can be connected 17 Ah 24 V DC/5 A, power 150 W, max. battery capacity which can be connected 45 Ah Figure 4: Mains connection in Standard and Comfort housings 1 EMC-critical zone (no high-voltage power permitted) 4 Cable strain relief for mains supply line 2 Mains connection from below (not perm

  • Siemens FC72x, Indication and operating elements C - WEB network 6 43 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 6 Indication and operating elements Fire control panel FC72x Fire terminal FT724 LED module FTO2008 Floor repeater terminal FT2010 Floor repeater display FT2011 Cerberus Remote Indication Alarm X X X X X X Pre-alarm X X X X X X Fault X X X X X X Isolation X X X X X X Test mode X X X -- -- X Technology X X X -- -- X Activation X X X -- -- X Information (Note) X X X -- -- X Activated remote transmission (RT) X X X X -- X Operation Acknowledge X X -- X -- X Reset X X -- X -- X Scroll in event lists X X -- X X X Deactivate internal buzzer X X -- X

  • Siemens FC72x, Installation Hardware c omponents 5 26 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 The outputs can be used e.g. for monitored activation of remote transmission equipment 'RT' (e.g. phone dialing equipment). The connection lines are switched with a monitoring resistor (termination resistor). The resistance value stated corresponds to monitored normal operation. All resistance values outside this range result in a fault message. Enabling example for transmitting a fault message Termination resistor R = 1.6 kOhm – 2.3 kOhm Enabling example for transmitting an alarm message Monitoring resistor (R + Ri) Rges = 2.3

  • Testing the installation Checking functions 8 59 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 8 Testing the installation The fire detection installation can be switched to 'Test' operation mode to check it is functioning properly. 8.1 Checking functions The table below shows the recommended intervals for checking functions. Na

  • Siemens FC72x, Installation Hardware components 5 24 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 5.3.2 Relay for fault and alarm (RT activation) Assignment of connection terminals on periphery board (identical for FC722 and FC724). Permitted cable cross-section: 0.2…1.5 mm 2 . FC722 and FC724 X7 Designation Description 6 FAU_NC Break contact fault (normally closed) Potential-free directional contact Max. 24 V DC/1 A 5 FAU_COM Center tap fault (common) 4 FAU_NO Make contact fault (normally open) 3 AL_NC Break contact alarm (normally closed) Potential-free directional contact Max. DC 24 V / 1 A 2 AL_

  • Siemens FC72x, Commissioning Restart the station 7 57 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 7.7 Restart the station The configuration of the ↑ ' Station ' remains the same. There are the following ways in which to restart the ↑ 'Station': ● Via the menu on the display ● PMI & mainboard FCM2004 and FCM2027: With the 'S32' button ● ↑ CPU card: With the 'S8' button Via the menu on the display If you are using two ↑ CPU cards, you must perform the following procedure once for each CPU card. 1. Press <MENU>.  The PIN input dialog is displayed. 2.

  • Siemens FC72x, Mounting Mounting instructions 4 16 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 4.1 Mounting instructions The station's equipment pack contains an mounting model with the dimensions needed and details of the mounting points to assist with mounting. The station must be assembled in a dry, clean and well vented room. The station must be assembled at a distance of least one door leaf width from the room's entrance. Select the height of mounting such that the display and optical indi

  • Installation C - WEB network 5 40 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 Figure 14: Wiring example of C-NET detector devices on stub (1) If shielded connection cables are used, the cable shielding must be connected on one side. * The number of connectable C-NET devices and the max. line length depend on the device connection factor. The

  • Siemens FC72x, Installation Position of printed circuit boards / components 5 18 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 5.1 Position of printed circuit boards / components Figure 2: Position of components in housing (Standard) for FC722 Figure 3: Position of components in housing (Comfort) for FC722 or FC724 1 Batteries 6 Mains connection terminals (L1,N,PE) 2 Power supply (70 W) 7 Loop extension option (C-NET) 1 x for FC722, 2 x for FC724 3 Power supply (150 W) 8 Shield connection terminal blocks or cable kit option (communication) 4 Periphery boar

  • Siemens FC72x, System overview Responsibility of the operator 3 12 | 62 Building Technologies A6V10211094_f_en_ -- Fire Safety 2015 - 12 - 15 3 System overview The FC720 Cerberus PRO fire control panels can be operated as standalone panels or networked into a fire detection system. Up to 32 stations (fire control panels, fire terminals) are networked via the C-WEB/SAFEDLINK system bus. The Cerberus PRO fire control panels support operation of the C-NET detector line. 1 FC722 or FC724 fire control pane

Related Products and Documents (Control Panel):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Chamberlain Security + 3850PC Owner's manual chamberlain/security-3850pc-395.pdf 27 Feb 2023 80 7.65 Mb
2 Blaupunkt Lübeck CC 22 Operating instructions manual blaupunkt/lubeck-cc-22-I8V.pdf 09 May 2023 12 0.08 Mb
3 Brother BE-0901E PC Settings manual brother/be-0901e-pc-1E4.pdf 13 Aug 2022 4 0.16 Mb
4 Sagem Internet Phonefax 2390@ Operation & user’s manual sagem/internet-phonefax-2390-Y45.pdf 16 Sep 2022 68 1.21 Mb
5 Apple MB598LL Operation & user’s manual apple/mb598ll-I6A.pdf 05 Nov 2022 80 1.79 Mb
6 Yamaha YZ125(R)/LC Owner's service manual yamaha/yz125-r-lc-PZ3.pdf 27 Mar 2023 568 13.46 Mb

Similar Resources:

  • Assa Abloy

    effeff 1383

    (76 pages)
    ASSA ABLOY, the global leaderin door opening solutionswww.assaabloy.deEscape route technologyD0055805Escape Door Control TerminalTyp 1383/1384/1385/1385TFitting and Installation Instructions …
  • Lumens

    VS-KB30

    (3 pages)
    FW003 - VS-KB30 FW Update Manual 1 VS-KB30 Firmware(FW) Upgrade Please contact Lumens FAE Department through e-mail to get the proper FW and AP before upgrading. 1 Device and Tool Preparation 1.1 Please prepare …
  • Viessmann

    VITOTRONIC 100

    (44 pages)
    Operating instructionsfor the system userVIESMANNHeating system with control unit for operation with a constant boiler watertemperature■Vitotronic 100, type CC1E■Vitotronic 100, type CC1IVITOTRONIC 1005798 582 GB 3/2017Please keep safe. …
  • Lexmark

    Dot Matrix

    (3 pages)
    March 2004Your LexmarkTM Printer DriverTechNote Using your printer driver:creating custom formsThe ability to associate a friendly name with a group of frequently used, personalized document settings can be a welcome timesaver in your printing environment. The Custom forms feature allows administrators to save a uniquely-named collection of document settings …
  • Fischer Panda

    P6+

    (28 pages)
    Panel Generator Control P6+ RE0703_Kunde_eng.R10 10.5.17Generator Control Panel P6+ Manual12 V version - 0000139 24 V special version - 0000527Option automatic adapter - 0000521Option master-slave adapter - 0000133 …
  • VRinsight

    MS Panel

    (24 pages)
    MS (Multi Switch) Panel by VRinsightFEATURESThank you for purchasing Multi Switch panel. Please read through this guide before use and contact [email protected], if you have any problem.This guide consists of four sections : FEATURES, INSTALLATION, CALIBRATION and APPLICATION.AEFHIGuide-MS panel(Sept2010)www.vrinsight.comTel : +82-31-284-7090~91 Fax : +82- …

Comments, Questions and Opinions: