Siemens HiPath 1100 Service Manual
|
Siemens HiPath 1100, Modules A31003-K1160-S100-03-7620 3-33 Service Manual Expansion Modules (EB) 3.5.4 TME1 Module A TME1 module can be configured for operating as a E1 CAS or S2 access. I ● E1 CAS Access A TME1 module with E1 CAS access consists of a Digital Interface Unit (DIU) used for connecting the HiPath 1150/1190/1190R to the PSTN via a E1 trunk. The E1 trunk can carry 30 digital voice channels. However, the HiPath 1150 systems use up to 20 channels, while the HiPath 1190 systems use up to 30 channels with the TME1 module allocated to slot 1 and up to 15
Siemens HiPath 1100, A31003-K1160-S100-03-7620 Service Manual 3-2 Modules Abbreviations 3.2 Abbreviations Table 3-1 Abbreviations 3.3 List of Modules List of Modules/Components - HiPath 1120 BRA Brazil IM International Market RSA South Africa CND Canada ARG Argentina SPA Spain IND India RUS Russia UK United Kingdom AUS Australia Module / Component Reference BOX HiPath 1120 S30817-U857-B401-* (IM) :110V S30817-U857-A401-* (IM) :220V S30817-U857-C401-* (ARG) S30817-U857-A403-* (CND) S30817-U857-A412-* (SPA) S30817-U857-A464-* (IND) S30817-U857-A497-* (RSA) S30817-U857-A408-* (UK) S30817-U857-A400-* (AUS) Motherboard (MB) MB S30817-Q
Siemens HiPath 1100, Figures A31003-K1160-S100-03-7620 0-8 HiPath 1100, Service Manual 4-46 Figure 4-36 Illustration of USB cable connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-48 Figure 4-37 Illustration of USB cable connection on HiPath 1190 . . . . . . . . . . . . . . . . 4-49 Figure 4-38 Diagram of Power Supply Configuration for the HiPath 1150/1190/1190R Sys- tems 4-53 Figure 4-39 Protection and Grounding Connection Diagram. . . . . . . . . . . . . . . . . . . . 4-54 Figure 4-40 Connections for telephone jacks (for Brazil). .
Siemens HiPath 1100, Modules A31003-K1160-S100-03-7620 3-65 Service Manual V.24 Adapter Cable 3.12 V.24 Adapter Cable A V.24 adapter cable (S30122-x5468-x5-*) is used for connecting to a PC, a modem (for programming the system using the HiPath 1100 Manager software, and for enabling CTI features) or a printer (for printing call or configuration data). . Figure 3-41 V.24 Adapter Cable Connection System V.24 adapter cable signals The V.24 serial interface module cannot be used if the system has an ADSL Module installed. Additional electr
Siemens HiPath 1100, A31003-K1160-S100-03-7620 Service Manual 2-5 System Data Limitations to System Expansion 2.5 Limitations to System Expansion Standard Configuration: HiPath 1120 HiPath 1150 HiPath 1190 External Analog Lines 2 0 Analog Extensions 8 10 Fax/DID 8 channels System Telephone Interface (KS) * 4 8 Expansion Modules: EB 010 (10 extensions) 0414 EB 012 (12 extensions) 0 3 11 EB 202 (2 external lines and 2 extensions) 0 4 16 EB 204 (2 external lines and 4 extensions) 2 0 EB 206 (2 external lines and 6 extensions) 0
Siemens HiPath 1100, A31003-K1160-S100-03-7620 Z-2 Service Manual M Main Distribution Frame (MDF) 3-58, 3-59 Modules 3-1 Overview 3-1 Motherboard (MB) 3-8 HiPath 1120 3-8 HiPath 1150 3-14 O Option Module (OM) TME1 module 3-33 Option Modules (OM) 3-45 CD 16 module 3-51 S0 module 3-29 UP0/E Module and CTR UP0/E Module. 3-42 Option modules (OM) ADSL module 3-45 Fax/DID module 3-49 Option Modules(OM) HiPath 1120 Music module 3-52 P Performing a Visual Inspection 4-59 Power Supply Unit (PSU) 3-54 Power Systems 2-1 Powering/Protecting the System 4-52 Profiset 3030 System Te
A31003-K1160-S100-03-7620 Service Manual 6-2 Operation Programming with a Telephone Set 6.1 Programming with a Telephone Set System programming can only be executed using the system’s first extension slot (default extension 11) with an analog extension (MF), a KS-type system telephone or an optiPoint 500 system telephone. Programming cannot be done simultaneously on two e
Siemens HiPath 1100, A31003-K1160-S100-03-7620 Service Manual 4-57 Installation Installing Telephone Terminals Connections Figure 4-40 Connections for telephone jacks (for Brazil) Red wire (R) = voice (extension’s B wire). Green wire (G) = voice (extension’s A wire). Black wire (BK) =CD card’s C wire (positive in relation to D). Yellow wire (Y) =CD card’s D wire (negative in relation to C). Installation Procedures Step Procedure 1. Install telephone jacks at the extensions. 2. Connect each extension jack to the desired a/b slot on the Main Distribution Frame. 3. KS-type system telephones are preset at factory defaul
A31003-K1160-S100-03-7620 Service Manual 7-17 Configuring the system specifically for the client Table of the System’s Programming Codes Table 7-14 Call Detail Recording Call Detail Report for Incoming Calls * 161 1 - Incoming/Outgoing calls 2 - Outgoing calls 3 - Incoming/Outgoing calls + CLIP 4 - Outgoing calls + CLIP Automatic 1 - Incoming/ Outgoing Call Detail Report F
Siemens HiPath 1100, Configuring the system specifically for the client A31003-K1160-S100-03-7620 7-8 Service Manual Table of the System’s Programming Codes Override 144 Extension 0 - Without permission 1 - With permission and beep # instead of extension 0 Silent Monitoring 046 Extension ∗ - To enable # - To disable # instead of extension # - To disable Caller ID for analog extension (CLIP) 010 Analog extension 0 - No Caller ID 1 - DTMF before ringing 2 - DTMF during ringing 3 - FSK before ringing 4 - FSK during ringing 5 = FSK prior to ringing or during a conversation 6 = FSK during ringing or a conversation # instead of extens
Siemens HiPath 1100, Operation A31003-K1160-S100-03-7620 6-25 Service Manual Driver Installation ● In the next window select "EURO-ISDN (DSS1)" and click "Next": Figure 6-21 Windows ME - selection for ISDN ● Enter an available extension number in the "Phone # (MSN)" field (for HiPath 1120/1150 the default extension is 10; for HiPath 1190 the default extension is 100). Click "Next" to confirm. The same window appears again. Click "Next" one more time without entering anything in any field: Figure 6-22 Windows SE - MSN Number
Siemens HiPath 1100, A31003-K1160-S100-03-7620 Service Manual 4-1 Installation HiPath 1100 Installation 4Installation 4.1 HiPath 1100 Installation About this Chapter This chapter contains information on: ● HiPath 1100 System Setup. More information on additional equipment and expansions can be found in the “List of Modules” on page 3-2; ● Configuration (installation of modules). Tools and Equipment Required The following tools are required for installing a HiPath 1100 system: – Cutters and flat nose pliers – Standard screwdriver – Phillips screwdriver – Tool for attaching wires to the Main Distribution Frame �
Siemens HiPath 1100, Configuring the system specifically for the client A31003-K1160-S100-03-7620 7-66 Service Manual Comments about the System’s Programming Codes Symmetric/Asymmetric Call (074) This setting configures the system for symmetric or asymmetric calls. Check with your local carrier to know which operating mode should be configured for your system. No ACK Setup for S 0 Line (075) Check with your local carrier to know which operating mode should be configured for your system. Notify (076) Check with your local carrier to know which operating mode should be configured for your system. Automatic Keypad (077) Your local carrier can inform you which ISDN features can be controlled
Siemens HiPath 1100, A31003-K1160-S100-03-7620 Service Manual 7-37 Configuring the system specifically for the client Comments about the System’s Programming Codes Waiting Message before Signaling a UCD Call (032) This feature allows you to connect a call waiting message for incoming calls before they ring at an extension. Minimum Time for Call Waiting Message in a UCD Queue (033) This setting specifies a minimum length of time until a message is played for calls waiting in a UCD Queue (032). Hunt Groups (HG) (021) This setting allows you to group extensions into a maximum of 10 Hunt Groups (780 to 789). A Hunt Group (HG) is a group of extensions assigned for answering calls made to
Installation A31003-K1160-S100-03-7620 4-50 Service Manual Installing an External Audio Source 4.11 Installing an External Audio Source The HiPath 1100 systems provide connections for audio devices, such as radios, tuners, CD, MD, and others. ● HiPath 1120 The audio source must be connected to a Music Option Module using an RCA connector in slot X1 (see Figure 4-
Siemens HiPath 1100, Operation A31003-K1160-S100-03-7620 6-45 Service Manual Driver Installation Windows XP Proceed as follows: 1. Connect the HiPath 1100 system to the computer 2. The Found New Hardware Wizard window appears so that new drivers can be installed. Choose "Install from a list or specific location (Advanced)." Click "Next" to proceed. Figure 6-45 Windows XP - Driver location 3. A second window opens. Select “Search for the best CAPI in these locations” then select “Include this location in the search”. Unde
Siemens HiPath 1100, Installation A31003-K1160-S100-03-7620 4-58 Service Manual Installing Telephone Terminals For 2-wire analog telephone sets (A, B) there will be no problem in the event of a momentary short-circuit. The maximum distance for installing a KS-type system telephone using a two-pair cable with a 0.4 mm 2 copper wire is 0.3 miles (500 meters). For standard telephones the maximum distance is 1.5 miles (2,500 meters). 4.16.1 Example of an optiPoint Master/Slave Connection ● optiPoint Master/Slave Telephone Connection Important When there are more than four optiPoint 500 telephones (master or slave) in the Hi- Path 1120 syst
Siemens HiPath 1100, Telephones A31003-K1160-S100-03-7620 5-6 Service Manual System Telephones 5.2.5 optiPoint 500 System Telephones optiPoint 500 Advance/Economy/Basic/Standard System Telephones feature a 2-line, 24- character per line alphanumeric display. This system telephone features a 2-line display: ● Line 1 displays time, date, requests, error messages and confirmation messages, as appropriate. ● Line 2 displays the internal number, system name, and available options that can be selected by pressing :. If the ">" appears on the right, it means there are more options
Siemens HiPath 1100, A31003-K1160-S100-03-7620 Service Manual 4-37 Installation Installation of Expansion and Option Modules 4.7.9.3 On the HiPath 1190/1190R Figure 4-31 Installing power supplies on the HiPath 1190/1190R Step Procedure 1. Check network voltage 2. Remove the system’s back cover. 3. If the voltage is within the power supply’s range, insert the power supply into the slots shown in Figure 4-31. 4. Plug the system’s AC cord into the AC input on the power supply (see Figure 3-34). 5. Connect to the backplane.
Siemens HiPath 1100, Installation A31003-K1160-S100-03-7620 4-24 Service Manual Installation of Expansion and Option Modules 4.7.2.3 On the HiPath 1190/1190R Installation Procedures 4.7.3 Installing a TME1 Module 8. Configure the required data (see “Operation” on page 6-1). Step Procedure 1. Turn off the power supply. 2. Remove the system’s front cover. 3. Remove the system’s back cover. 4. Move the module’s latch as shown in Figure 4-12. 5. Insert the module into one of the slots shown in Table 4-2. 6. Move the module’s latch back to secure mo
A31003-K1160-S100-03-7620 Service Manual 6-8 Operation Programming the system using a PC 6.2.1.3 ADSL Module (LAN) With this option an internal network access is used with an ADSL module. In order to do this, HiPath 1100 applications must be installed. After restarting your computer, configure the appropriate settings for the CommServer. Procedure: 1. Insert th
A31003-K1160-S100-03-7620 Service Manual 3-32 Modules Expansion Modules (EB) Table 3-18 S 0 Module connectors for HiPath 1150/1190/1190R S 0 Basic Access Figure 3-15 S 0 Basic Access Connection S 0 Module Connector Figure 3-16 S 0 connector signal distribution Setup and Installation of S 0 Module Connectors Table 3-19 Installing a S 0 Module System Position/Slot HiPath 112
Siemens HiPath 1100, Configuring the system specifically for the client A31003-K1160-S100-03-7620 7-30 Service Manual Comments about the System’s Programming Codes Attendant Console (150) This streamlines the flow of calls to one console equipped with a system telephone with a display. Carrier Dialing Mode Field: LCR or ACS (225) This allows the user to change carrier selection and use the best possible option to originate external calls. Warning Tone for Calls without LCR (092) When the system is configured to use L
Siemens HiPath 1100, A31003-K1160-S100-03-7620 Service Manual 5-5 Telephones System Telephones E821 ST System Telephone Layout Figure 5-3 E821 ST System Telephone Layout 1) Programmable LED keys for status indication 2) Special function keys 3) Handset release key. 3 2 1
Siemens Gigaset C285-2 PBX Operation & user’s manual
Gigaset C285-2 |
Siemens OpenStage 60 SIP PBX Operation & user’s manual
OpenStage 60 SIP |
Siemens Gigaset C59H PBX Operation & user’s manual
Gigaset C59H |
Siemens OpenStage Asterisk PBX Installation and maintenance manual
OpenStage Asterisk |
Siemens Gigaset C385 PBX Operation & user’s manual
Gigaset C385 |
Siemens 3035isdn PBX Operating instructions manual
3035isdn |
Siemens HiPath 8000 PBX Operation & user’s manual
HiPath 8000 |
Siemens SIMATIC NET CP 343-1 PBX Product information
SIMATIC NET CP 343-1 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Exmark | Phazer 4500-461 | Parts manual | exmark/phazer-4500-461-X8F.pdf | 19 Sep 2022 | 20 | 3.52 Mb |
2 | Plantronics | Voyager PRO+ | Operation & user’s manual | plantronics/voyager-pro-82U.pdf | 28 Jan 2024 | 23 | |
3 | Sony | PSP-1010 | Instruction manual | sony/psp-1010-7Z7.pdf | 25 Aug 2023 | 284 | 4.86 Mb |
4 | Moyerdiebel | 501-HT | Technical manual | moyerdiebel/501-ht-96U.pdf | 27 Sep 2023 | 60 | |
5 | Lenovo | ThinkPad L412 | Setup manual | lenovo/thinkpad-l412-41B.pdf | 25 Dec 2023 | 2 | |
6 | Panasonic | AGRT850 - TIME LAPSE VTR | Operating instructions manual | panasonic/agrt850-time-lapse-vtr-I5G.pdf | 28 Sep 2023 | 32 |
Polycom
HOSTED VOICE..........................................................................................................................................................................................GoLightpath.com • 1-877-LightpathUNDERSTANDING POLYCOM® VVX® 500 UNDERSTANDING POLYCOM® VVX® 500TABLE OF CONTENTS:COVER : UNDERSTANDING POLYCOM® VVX® 50 …
Polycom VVX 500(4 pages) |
Northern Telecom
© 1987 Northern TelecomAll rights reserved.NT, Meridian 1, Meridian and SL-1 are trademarks of Northern Telecom.Title to and ownership of SL-1 software shall at all times remain with Northern Telecom. SL-1software shall not be sold outright and the use thereof by the customer shall be subject to theparties entering into agreement as specified by Northern T …
QCA146(75 pages) |
NEC
www.finelinecoms.co.uk Fine Line Communications (EA) Limited, Logic House, Harfreys Road, Harfreys Industrial Estate, Great Yarmouth NR31 0LS Telephone (01493) 441114 Facsimile (01493) 441124 Email: [email protected] Registration No. 4519551 E&OE Page 1 of 6 NEC SL1100 Voicemail User Guide To setup your voicemail: Dial th …
SL1100(6 pages) |
Panasonic
Pure IP-PBXGetting Started for Physical CardsModel No. KX-TDE100KX-TDE200Thank you for purchasing a Panasonic Pure IP-PBX.Please read this manual carefully before using this product and save this manual for future use.KX-TDE100/KX-TDE200: PMMPR Software File Version 2.0000 or later
…
KX-TDE200(30 pages) |
Epygi
‘All in One Box’ SolutionsHow do Users Benefit From the Quadro?A proven, centralised telecoms system that unies all the company’s branches.All the functions of a traditional PBX, plus a host of additional features.Easy to install and easy to use.Compact stand-alone equipment that is com-patible with most IP phone systemsVoice over Internet Protocol …
Quadro Quadro 2x(1 pages) |
Panasonic
Pure IP-PBXOperating ManualThank you for purchasing a Panasonic Pure IP-PBX.Please read this manual carefully before using this product and save this manual for future use.KX-NCP500/KX-NCP1000: PBMPR Software File Version 4.1000 or laterKX-TDE100/KX-TDE200: PMMPR Software File Version 4.1000 or laterKX-TDE600: PGMPR Software File Version 4.1000 or laterDocum …
KX-NCP500(230 pages) |
Whirlpool Ice Maker R-106Whirlpool R-106 Manual (Training manual), @FN6VO8 R-106, 34 |
Clipper Saw C13SPM#OQ9J15 C13SPM: Clipper Saw Owner Documentation C13SPM, 30 |
Rifton Bicycle R120Rifton Bicycle R120 Product manual R120, 16 |
Cooper Lighting Indoor Furnishing FAIL-SAFE VRM332Indoor Furnishing PDF Specification sheet FAIL-SAFE VRM332, 2 |
NETGEAR Modem CG3300DNETGEAR Modem Installation manual (File: netgear-cg3300d-installation-manual-2, Wed 10.2023) CG3300D, 2 |
StarTech.com Switch SV231USBOperation & user’s manual for StarTech.com SV231USB Switch SV231USB, 13 |
Mount-It! Racks & Stands MI-2291Manual: Mount-It! MI-2291 (6482BR, Upd.13th Sep 2023) MI-2291, 7 |
BBK Receiver SMP124 HDT2BBK SMP124 HDT2 User Guide (Doc Type: Receiver Service manual) SMP124 HDT2, 27 |
TV One Switch S2-101AATV One Switch Operation manual (File: tv-one-s2-101aa-switch-68, Thursday 28-12-2023) S2-101AA, 68 |
Olympus Digital Camera STYLUS 300#C396EQ: STYLUS 300 Digital Camera Guía de inicio rápido STYLUS 300, 2 |
Sharp Monitor PN-E421Operation & user’s manual for Sharp PN-E421 Monitor PN-E421, 13 |
Oster Kitchen Appliances JusSimple#69K5FG: JusSimple Kitchen Appliances Operation & user’s manual JusSimple, 32 |