Siemens SIMATRIX NEO V2 Configuration Manual
|
Disposal 10 Disposal All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. If this symbol showing a crossed-out trash can is displayed on a product, that product is subject to the EU Directive 2002/96/EC. The correct
Siemens SIMATRIX NEO V2, Liefermöglichkeiten und technische Änderungen vorbehalten. Data and design subject to change without notice. / Supply subject to availability. © 2013 Copyright by Siemens Building Technologies Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger erkennt diese Rechte an und wird dieses Dokument nicht ohne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder außerhalb des Zweckes verwenden, zu dem es ihm übergeben worden ist. We reserve all rights in this document and in the subject thereof. By acceptan
Siemens SIMATRIX NEO V2, Maintenance 9 Maintenance Danger When in operation, a number of components in this device are electrically live. Inexpert handling or operation of this device could therefore result in death, severe bodily harm or damage to property. The device may only be serviced and maintained by suitably qualified personnel. The device must be isolated from the electrical supply before work starts on it. In the event of breakdown, we recommend you contact your local Siemens branch for service and support. The mains supply voltages and secondary voltages are fused as follows: Electrical supply 11
Siemens SIMATRIX NEO V2, Appendix 11.2 Summary of basic and alarm program features Features Alarm program 1 Alarm program 2 Factory setting Alarm program 4 Alarm program 5 Alarm program 3 Alarm program 6 Devices Cameras1 to 48 1 to 48 1 to 48 1 to 48 1 to 48 1 to 48 Camera head controls 1 to 48 1 to 48 1 to 48 1 to 48 1 to 48 1 to 48 Monitors 1 to 4 1 to 4 1 to 4 1 to 4 1 to 4 1 to 4 Keyboards 1 to 4 1 to 4 1 to 4 1 to 4 1 to 4 1 to 4 IVM-NT operating stations 1 to 3 1 to 3 1 to 3 1 to 3 not recommended for IVM-NT not recommended for IVM- NT TELEMAT not recommended for TELEMAT not recommended for TELEMAT Basic functions (ava
Siemens SIMATRIX NEO V2, System extensions Fig. 22 Bus boards 8.1.2 Extension up to a maximum of 32 video outputs (SIMNEO-OM) 1. Each extra video output module must be inserted into the lowest available slot. 2. Screw the module to the rear cover of the SIMATRIX NEO. 3. Connect the module to the mainboard using a suitable flat cable. Fig. 23 SIMNEO-OM video output module 38 Siemens AB Security Products
Siemens SIMATRIX NEO V2, Total system with full options 5 Total system with full options The SIMATRIX NEO V2 video matrix allows CCTV systems to be constructed in a compact, modular format. SIMATRIX NEO not only allows the connection of video signals using keyboards, it also allows contact-controlled alarm processing and makes it possible to interface to higher-level management systems such as IVM, the hazard alert system TOPSIS, etc. Fig. 1 System configurations with TELEMAT MD/MTD, IVM, SISTORE and detection groups (alarms) 13 Siemens AB Security Products
Siemens SIMATRIX NEO V2, 3 Siemens AB Security Products Contents 1 Safety .......................................................................................................5 1.1 Target readers...........................................................................................5 1.2 Work safety information ............................................................................5 1.2.1 General information...................................................................................5 1.2.2 Transport...................................................................................................5 1.2.3 Set
Siemens SIMATRIX NEO V2, Installation 6.1.5 Pin allocation for the 37-pin Sub-D alarm 1 - 16 and alarm 17 – 32 sockets The Alarm 1 - 16 / TTY out and Alarm 17 - 32 / TTY out sockets each have 16 alarm inputs, rated to +5V using internal pull-up resistors. The TTY outputs are set to a data rate of 2400 Baud and use the SCU protocol. Fig. 11 Alarm 1 - 16 and Alarm 17 – 32 Caution Do not connect –TX to GND, as the negative voltage will short-circuit to GND and place an unnecessary load on the power supply unit. Pin Alarm input function Pin TTY function 1 Alarm input 1 20 –TX TTY 1 2 Alarm input
System extensions 43 Security Products Alarm box / Input Alarm input, operating profile 1 Alarm input, operating profile 2 Alarm input, operating profile 3 Box 2 / Input 1 193 - 224 161 -192 129 - 160 Box 2 / Input 2 225 -240 193 - 224 161 -192 Box 2 / Input 3 not used 225 -240 193 - 224 Box 2 / Input 4 not used not used 225 - 240 Tab. 11 Allocation of pins
Installation 6 Installation The SIMATRIX NEO V2 system is built in modular 19 inch format. The 19 inch component trays have been designed to suit 19 inch frames and cabinets. The side walls of the component trays are perforated to allow good ventilation in the housing (via convection). When installing component tray modules, make sure that: – the ventilat
Siemens SIMATRIX NEO V2, Safety 1.2.3 Setup Damage due to unsuitable mounting location Observe the environmental requirements recommended by the manufacturer. See Section 3: „Technical data“. Do not operate the device close to sources of powerful electromagnetic radiation. Protect the device against moisture. Do not operate the device in excessively dusty places. Make sure that no objects, especially metal objects, can enter the device. Do not expose the device to mechanical vibrations or shocks. Liability claim For reasons of electromagnetic compatibility RS232, USB, audio in/out and power supply cables must not exceed 3 meters length. Damage to the device
Siemens SIMATRIX NEO V2, System extensions 8.3 Alarm box The alarm box extends the SIMATRIX NEO V2 by 128 alarm inputs. It is possible to operate two alarm boxes with a maximum of 240 alarm inputs. The way the alarm inputs are distributed over the basic unit, the extension bay and the alarm boxes is determined by an operating profile that is configured using the programming software. Operating profile Alarm inputs on the basic unit Alarm inputs on the extension bay Alarm inputs on alarm box 1 Alarm inputs on alarm box 2 Device adr. ------ “1” “2” “3” Operating profile 1 1 – 32 33 – 64 65 – 192
Siemens SIMATRIX NEO V2, Installation 6.2 Connecting the video inputs Connect video inputs to the BNC sockets that are labelled Video Input 1 Vss / 75 Ohm. Video sources that are compatible with the SIMATRIX NEO V2 provide a PAL/CCIR video signal at a voltage of 1V SS and an input impedance of 75 . Up to 16 video sources can be connected to the BNC sockets per input unit. Each video input teminates in a 75 feed-through jumper. The plug-in jumpers are located on the PCB next to the appropriate BNC socket. Video signal requirements To ensure problem-free synchronisation and correct text overlay at the video output, the incoming video signal must have a standard level of 1.0 Vpp at 75
Total system with full options 21 Security Products Status display (examples) Meaning 30.11.04 Std Temp Powersuppl: +45°C Power supply temperature The power supply could be overloaded if a temperature higher than 70°C is displayed. If this occurs, a qualified electrician should check all system voltages. Temp Mainboard: +35°C Mainboard/internal tempe
Siemens SIMATRIX NEO V2, Safety 1.3 Meaning of the written warning notices Signal word Type of risk DANGER Risk of death or severe bodily injury Warning Possible danger of death or severe bodily harm CAUTION There is a risk of minor injuries or damage to property IMPORTANT Malfunctioning may result 1.4 Meanings of the hazard symbols Warning Caution - Dangerous area! Warning Caution - Dangerous electrical voltage! 8 Siemens AB Security Products
Siemens SIMATRIX NEO V2, Set-up SIMATRIX NEO V2 to suit individual operating needs and the rest of the system. 10. Make a back-up of the parameter settings and store the back-up close to the system in a safe place. 7.3 Programming the SIMATRIX NEO The SIMATRIX NEO V2 is programmed at the factory to load alarm program 2 as standard. This program allows alarms to be received and processed immediately. The keyboards and the IVM- PCs will switch cameras in and out and control cameras with pan/tilt and lens drives. To load other data o
Appendix 46 Siemens AB 11 Appendix 11.1 Glossary Alarm image switching An alarm image appears on the monitor until it is acknowledged Alarm image sequence All as yet acknowledged alarm images are shown repeatedly in sequence on a monitor Alarm sequence See alarm image sequence Autoreset The alarm image disappears from the monitor, as soon as the alarm signal resets. See als
Siemens SIMATRIX NEO V2, Directives and standards 2 Directives and standards This product complies with the requirements of the European Directives 2004/108/EEC “Directive of Electromagnetic Compatibility” and 2006/95/EEC “Low Voltage Directive”. The EU declaration of conformity is available to the responsible agencies at: Siemens AB Infrastructures & Cities Sector Security Products International Headquarters Englundavägen 7 SE-171 41 SOLNA European Directive 2004/108/EEC "Electromagnetic Compatibility" Compliance with the European Dire
Siemens SIMATRIX NEO V2, Installation 6.1.3 Pin allocation for the 6-pin RJ12 keyboard sockets The SIMATRIX NEO V2 allows the connection of 8 keyboards via CL/TTY interfaces. The factory transfer setting of 2k4, 8E1 can be changed using the programming software. Fig. 8 6-pin RJ12 "Keyboard" sockets Pin Function 1 GND 2 – RX 3 +RX 4 – TX 5 +TX 6 +12V Tab. 2 Pin allocation for the 6-pin RJ12 "Keyboard" sockets A maximum of 8 keyboards can be connected to the keyboard interfaces. Each keyboard may draw a maximum of 200mA from the SIMATRIX NEO. The total current draw must not excee
Siemens SIMATRIX NEO V2, Total system with full options 5.3.2 Alarm program 2 (factory setting) All the alarm programs are described in detail in the programming software manual. An overview of the alarm programs is included in the appendix. When processing alarms using alarm program 2, the following functions are available in addition to basic unit functionality: – A detection group can be connected for each camera. – The 32 alarm inputs are programmed for signal connection in reaction to external contact switching. – Alarm program 2 displays alarm images on monitors 1, 2 and 4. Monitor 3 is
Installation Connecting an external computer to the COM interfaces on the NEO The following illustrations show how to connect a computer to the RS232 interface on the SIMATRIX NEO V2 (COM 2, COM 3, COM 4) using a 9-pin or 25-pin Sub-D connector: Fig. 9 Connecting an external computer to COM 2, COM 3, COM4 on the SIMATRIX NEO V2 using a 25-pin connector Fig. 10 Connectin
Siemens SIMATRIX NEO V2, Total system with full options Interfaces for external communication purposes Interface designation/type Qty. Use programmable Baud rate COM 2, COM 3, COM 4 RS232 3 for programming the SIMATRIX NEO V2 and connecting an external computer. Protocols IVM-NT, TELEMAT MD/MDT, SISTORE NT, log printer, secondary control systems see programming manual standard setting 19.2 kBaud Keyboard 4-wire ,CL-20mA/TTY interface 8 for connecting up to 8 keyboards see programming manual standard setting 9600 kBaud Alarm 1 - 16/ TTY out Alarm 17 - 32/ TTY out CL-20mA-/TTY interfaces I/O 0-15 2 x 8 For connecting telemetry devices see programming manual standard setting 24
Siemens SIMATRIX NEO V2, Ordering information 4 Ordering information Order reference Short designation Product Weight (approx. In kg) 2GF2211-8AA SIMNEO-168 SIMATRIX NEO V2 168, complete, 19" base module, 6 HU, PAL model*, incl. CPU, 16 video inputs, 8 video outputs, 32 alarm inputs *Note: NTSC model available on request 6.5 Extension options 2GF2211-8AB SIMNEO-EXT SIMATRIX NEO V2 19" extension bay, 6 HU, incl. 32 video inputs, 16 video outputs 6.3 2GF2211-8CA SIMNEO-IM Video input module, 16 extra video inputs 0.24 2GF2211-8DA SIMNEO-OM Video output module with text overlay, upgrade for the base module with 8 extra video outputs 0.03 2GF2211-8DB SIMNEO-SOM Video outp
Siemens SIMATRIX NEO V2, System extensions 8.2 Extension bay The BNC cables required for cascade operation are not included in the standard supply! The extension bay must be used with systems where more than 128 video inputs are required. The extension bay allows expansion of the SIMATRIX NEO V2 to up to a total of 224 or 240 video inputs in steps of 16 inputs, and up to a total of 32 video outputs in steps of 8 outputs. Video outputs in the system Available video outputs 1 – 16 240 17 – 32 224 Fig. 24 Rear view of the extension bay The extension ba
Siemens SIMATRIX NEO V2, Total system with full options 5.4 Interfaces The central processor controls and administers the entire SIMATRIX NEO V2 system with all its video inputs and outputs, detector groups, switch outputs and interfaces to keyboards, CDCs or an external computer. The control profile depends on the way system parameters have been set (see the SIMATRIX NEO V2 programming manual). Fig. 4 Interfaces on the back of the device A1 COM4: RS232 communication interfaces; data exchange with external computers or systems B Telemetry ports 1 – 4: RS422
Siemens SIMATRIX NEO V2, Technical data 3 Technical data 3.1.1 Video Video inputs BNC sockets U ss =1V video, 75 , with plug-in jumpers and switchable terminations Video outputs BNC sockets U ss =1V video, 75 Video signal failure recognition Vertical synchronisation pulse monitoring Text overlay Complete IBM character set, internal synchronisation, character display: white background, black frame Field size: 12 text lines of 24 characters each Character height: 18 screen lines Cross-talk attenuation 56 dB at 5 MHz Differential amplification 1% Differential phase 0,6 Frequency response characteri
Siemens SIMATRIX NEO V2, Total system with full options a previously selected monitor and to switch video recorders and save images to image memories. The way detection groups are allocated to cameras, the way alarm images are allocated to individual monitors and the choice between group or individual signal transfer are all freely programmable. 5.3 Settings on the CD-ROM The basic program and 6 alarm programs on the CD-ROM supplied with the device provide a level of set-up that allows the system to be put to immediate use. The programs supplied cover the most common applications. They also make it easier to adjust progr
Bosch PLE-1P120-EU Amplifier Installation and user instructions manual
PLE-1P120-EU |
Green Power GP-120 Amplifier Operating instructions
GP-120 |
Yamaha MCX-CA15 Amplifier Install manual
MCX-CA15 |
Anacon TUBEWONDER Amplifier Operation & user’s manual
TUBEWONDER |
Roland SRA-50 Amplifier Owner's manual
SRA-50 |
Tech 21 Landmark 300 Amplifier Owner's manual
Landmark 300 |
Ayon Vulcan Amplifier Owner's operating manual
Vulcan |
Klipsch ProMedia DD-5.1 Amplifier Operation & user’s manual
ProMedia DD-5.1 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Philips | RS 900 series HX6982/10 | Specifications | philips/rs-900-series-hx698210-T25.pdf | 26 Aug 2022 | 2 | |
2 | Franklin | QC-20 | Operation & user’s manual | franklin/qc-20-8U6.pdf | 14 Oct 2022 | 12 | 0.07 Mb |
3 | Weider | 215 Bench | Manual | weider/215-bench-177.pdf | 02 Sep 2023 | 16 | 0.87 Mb |
4 | Cadillac | 1997 Seville | Owner's manual | cadillac/1997-seville-K9Q.pdf | 15 Apr 2023 | 370 | 20.73 Mb |
5 | Haier | HR-710FD | Operation & user’s manual | haier/hr-710fd-8ZV.pdf | 31 Dec 2023 | 36 | 7.01 Mb |
6 | Reliable Equipment | REL-954RC | Operator's manual | reliable-equipment/rel-954rc-5AN.pdf | 16 Dec 2023 | 12 |
Monacor
ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTSBEDIENUNGSANLEITUNGINSTRUCTION MANUALMODE D’EMPLOIISTRUZIONI PER L’USOMANUAL DE INSTRUCCIONESINSTRUKCJA OBSŁUGIVEILIGHEIDSVOORSCHRIFTENSIKKERHEDSOPLYSNINGERSÄKERHETSFÖRESKRIFTERTURVALLISUUDESTA3-Kanal-PA-Verstärker3-Channel PA Amplifi …
STA-1603CLUB(18 pages) |
Signal
PLITSTR249 REV. C 2/5/07 A Division of Star Headlight & Lantern Co., Inc. INSTALLATION AND OPERATING INSTRUCTIONS SS730 SIREN AMPLIFIER
…
SS730(20 pages) |
RF-Tuote
SMART mini Adjustable amplifier User´s manual RF-Tuote Oy, Telakkatie 25 25570 Teijo FINLAND puh. 02-7366360, fax. 02-7366355 e-mail. [email protected] www.rf-tuote.fi
…
SMART mini(4 pages) |
Crate
BX-220HOKCONTOURCONTOURON/OFFINCREASE GAINDECREASE GAIN– 15dBMASTERLINE OUTLEVELEFFECTSBLENDHEADPHONESLEVELPOST/PRELIMITPOWERPOWER®GAIN01102357984601102357984601102357984601102357984601102357984612379846INPUTHEADPHONESBX-2115INPUTCONTOURGAINCONTOURON/OFF– 15dBMASTERLINE OUTLEVELEFFECTSBLENDHEADPHONESLEVELLIMIT®SPECTRUM� …
BX-220H(8 pages) |
Brinkmann
Manual for brinkmann Preamplifier MARCONI Design : Service :Brinkmann Audio Ing.-Büro R. Klatt-MilsmannIm Himmelreich 13 Deppendorfer Str. 15188147 Achberg DE 33793 Bielefeld DEGermany GermanyTel.: 08380 / 981195 Tel.: 05203 / 883033Fax: 08380 / 981233 Fax: 05203 / 883034www.brinkmann-audio.com [email protected]@brinkmann-audio.comLegal R …
MARCONI(5 pages) |
Pioneer
ORDER NO.PIONEER CORPORATION 4-1, Meguro 1-chome, Meguro-ku, Tokyo 153-8654, JapanPIONEER ELECTRONICS (USA) INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A.PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, BelgiumPIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra Road, #04-01, Singapore 159936PIONEER CORPORATION 2002TypeModelPower Req …
M-EV51(49 pages) |
Kozy-World Indoor Fireplace GLD2460RGLD2460R (Indoor Fireplace ePDF User Guide, #38AUYQ) GLD2460R, 35 |
Philips TV 15HF5234#KUOAAP: 15HF5234 TV Operation & user’s manual 15HF5234, 25 |
Siemens Transmitter SITRANS P DS IIISiemens SITRANS P DS III Manual (Operating instructions manual), @BUTV2W SITRANS P DS III, 266 |
Petsafe Pet Care Product PBC19-11794PBC19-11794 Operating manual - D5AY41 PBC19-11794, 72 |
Caframo Fan 797CA-GBXFan PDF Instructions for use 797CA-GBX, 2 |
Nyrius LED TV NY-LED1980N#O9OI29: NY-LED1980N LED TV Operation & user’s manual NY-LED1980N, 49 |
Black Rotary Hammer KD1001Rotary Hammer #92NZUI KD1001, 74 |
Kenwood Food Processor AT444Kenwood AT444 Food Processor Instructions AT444, 4 |
Zanussi Freezer ZFC623WAPZanussi Freezer ZFC623WAP Operation & user’s manual ZFC623WAP, 60 |
Kenwood Car Amplifier KAC-PS811D#B3U2YJ KAC-PS811D: Kenwood Car Amplifier Owner Documentation KAC-PS811D, 28 |
KT Speakers INTREPID 400Speakers PDF Operation & user’s manual INTREPID 400, 9 |
Baumatic Ice Maker EASYICE 1SLIce Maker Operation & user’s manual (Baumatic EASYICE 1SL) EASYICE 1SL, 16 |