Text of Siemens SIMATIC Ident User Guide:

  • Siemens SIMATIC Ident, System overview 3.3 System configuration SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 33 The entire production order that is saved on the transponder can also be read manually via the WIN-LC terminal located at each workstation. This means that virtually no additional data management is required on the control computer. The production order data can also be read for servicing purposes via the mobile SIMATIC RF350M reader. Figure 3-4 Example of engine block production

  • Siemens SIMATIC Ident, Planning the RF300 system 4.5 Guidelines for electromagnetic compatibility (EMC) SIMATIC RF300 112 System Manual, 07/2016, C79000-G8976-C345-0x Figure 4-19 Connection of shielding bus The shielding bus must be connected to the PE busbar. If shielded cables have to be interrupted, the shield must be continued via the corresponding connector housing. Only suitable connectors may be used for this purpose. Figure 4-20 Interruption of shielded cables If intermediate connectors, which do not have a suitable shield connection

  • Siemens SIMATIC Ident, Planning the RF300 system 4.5 Guidelines for electromagnetic compatibility (EMC) SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 109 4.5.6 Prevention of interference sources A high level of immunity to interference can be achieved by avoiding interference sources. All switched inductances are frequent sources of interference in plants. Suppression of inductance Relays, contactors, etc. generate interference voltages and must therefore be suppressed using one of the circuits below. Even with small relays, interference voltages of up to 800 V occu

  • Siemens SIMATIC Ident, Readers 5.4 SIMATIC RF340R/RF350R SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 141 5.4.1.9 Approvals FCC information Siemens SIMATIC RF340R (MLFB 6GT2801-2AA10); FCC ID NXW-RF340R Siemens SIMATIC RF340R (MLFB 6GT2801-2AB10); FCC ID NXW-RF340R01 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution Any changes or modifications not expressly approved by the party responsible for

  • Planning the RF300 system 4.5 Guidelines for electromagnetic compatibility (EMC) SIMATIC RF300 102 System Manual, 07/2016, C79000-G8976-C345-0x ● Route the signal cables as close as possible to chassis surfaces. ● Twist the feed and return conductors of separately installed cables. ● Routing HF cables: avoid parallel routing of HF cables. �

  • Siemens SIMATIC Ident, Readers 5.3 SIMATIC RF310R - second generation SIMATIC RF300 130 System Manual, 07/2016, C79000-G8976-C345-0x 5.3.3 Pin assignment of the RS-422 interface Table 5- 8 Pin assignment Pin Pin Device end 8-pin M12 Assignment 1 + 24 V 2 - Transmit 3 0 V 4 + Transmit 5 + Receive 6 - Receive 7 Unassigned 8 Earth (shield) 5.3.4 LED operating display The operational statuses of the reader are displayed by two LEDs. The LEDs can adopt the c

  • Readers 5.4 SIMATIC RF340R/RF350R SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 143 5.4.2 SIMATIC RF350R 5.4.2.1 Features SIMATIC RF350R Characteristics Design ① Antenna connection ② RS-422 interface ③ Status display Area of application Identification tasks in assembly lines in harsh industrial environments; for external antennas

  • Siemens SIMATIC Ident, Planning the RF300 system 4.5 Guidelines for electromagnetic compatibility (EMC) SIMATIC RF300 106 System Manual, 07/2016, C79000-G8976-C345-0x 4.5.5 Cabinet configuration The influence of the user in the configuration of an electromagnetically compatible plant encompasses cabinet configuration, cable installation, ground connections and correct shielding of cables. Note For information about electromagnetically compatible cabinet configuration, please cons ult the installation guidelines for SI

  • Siemens SIMATIC Ident, Readers 5.6 SIMATIC RF380R SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 167 Note correct assignment of the pins here: Pin Pin Device end 8-pin M12 Assignment RS-232 RS-422 1 + 24 V + 24 V 2 RXD - Transmit 3 0 V 0 V 4 TXD + Transmit 5 not used + Receive 6 not used - Receive 7 not used not used 8 Ground (shield) Ground (shield) 5.6.4 LED operating display The operational statuses of the reader are displayed by the LEDs. The LED can adopt the colors green, red or yellow and the statuses off , on , flashing : Table 5- 26 LED operating display on the re

  • Siemens SIMATIC Ident, Planning the RF300 system 4.4 Chemical resistance of the transponders SIMATIC RF300 90 System Manual, 07/2016, C79000-G8976-C345-0x 4.4 Chemical resistance of the transponders 4.4.1 Overview of the transponders and their housing materials The following sections describe the resistance to chemicals of the various transponders. Resistance to chemicals depends on the housing materials used to manufacture the transponders. The following table provides an overview of the housing materials of the transponders: Table 4- 55 Overview of the housing materials of the transponders Housing material Transponder Pol

  • Siemens SIMATIC Ident, Planning the RF300 system 4.3 Installation guidelines SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 71 Transponder RF340R reader Without metal On metal Flush-mounted in metal (20 mm all- round) MDS D200 1) Without metal 100 95 90 On metal; distance 20 mm 90 85 80 Flush-mounted in metal; distance all round 20 mm 75 50 65 MDS D261 Without metal 100 100 100 On metal; distance 25 mm 70 95 90 MDS D324 1) Without metal 100 95 80 On metal; distance 15 mm 90 85 75 Flush-mounted in metal; distance all round 25 mm 80 80 60 MDS D339 Without metal 100 95

  • Siemens SIMATIC Ident, Planning the RF300 system 4.2 Field data for transponders, readers and antennas SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 49 Note Possible reader-transponder combinations The tables of the following section show the possible reader -transponder combinations. 4.2.1 Field data of RF300 transponders The limit distances (S g ) and operating distances (S a ) along with the length of the transmission window for each reader-transponder combination are listed in the tables bel

  • Siemens SIMATIC Ident, Planning the RF300 system 4.3 Installation guidelines SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 85 Transponder ANT 30 without metal ANT 30 mounted in met- al (20 mm all-round) MDS D526 1) without metal ?? ?? on metal; distance 25 mm ?? ?? flush-mounted in metal; distance all round 50 mm ?? ?? MDS D528 without metal ?? ?? on metal, distance 0 mm ?? ?? 1) Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal. 2)

  • Siemens SIMATIC Ident, Planning the RF300 system 4.2 Field data for transponders, readers and antennas SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 53 Table 4- 10 Field data RF340R reader Length of the transmission window (L) Operating distance (S a ) Limit distance (S g ) MDS D100 90 5...110 140 MDS D124 60 2...60 75 MDS D126 80 2...85 110 MDS D139 90 5...80 110 MDS D160 50 2...35 60 MDS D165 130 5...100 125 MDS D200 125 5...80 110 MDS D261 95 5...6

  • Siemens SIMATIC Ident, Planning the RF300 system 4.3 Installation guidelines SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 79 Reader RF350R with ANT 12 and with ISO transponders (MDS D) Table 4- 44 Reduction of field data due to metal, range as %: Transponder and RF350R with ANT 12 Transponder ANT 12 without metal ANT 12 mounted in met- al (0 mm all-round) MDS D117 Without metal 100 85 On metal; distance 0 mm 90 85 Flush-mounted in metal; distance all round 0 mm 65 65 MDS D127 Without metal 100 85 On metal; distance 0 mm 95 85 Flush-mounted in metal; distance all round 0 mm 65 65 MDS D160 1) Without metal 1

  • Siemens SIMATIC Ident, Readers 5.7 SIMATIC RF380R with Scanmode SIMATIC RF300 178 System Manual, 07/2016, C79000-G8976-C345-0x RF380R face-to-face D ≥ 800 mm Figure 5-29 Face-to-face distance between two RF380R 5.7.8 Technical specifications Table 5- 31 Technical specifications of the RF380R Scanmode reader 6GT2801-3AB20-0AX1 Product type designation SIMATIC RF380R Scanmode Radio frequencies Operating frequency, rated value 13.56 MHz Electrical data Maximum range 200 mm Maximum data transmission speed reader ↔ transponder RF300 transponder ISO transponder • Read approx. 8000 bytes/s approx. 1500 byt

  • Planning the RF300 system 4.3 Installation guidelines SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 75 Transponder ANT 1 without metal ANT 1 on metal ANT 1 mounted in metal (40 mm all- round) MDS D423 Without metal 100 90 90 On metal; distance 0 mm 115 2) 115 2) 115 2) Flush-mounted in metal; distance all round 0 mm 80

  • Planning the RF300 system 4.3 Installation guidelines SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 63 Table 4- 30 Flush-mounting of transponders and readers Representation Description Problem: Flush-mounting of transponders and readers is possible in principle. However, the size of the transmis- sion window is significantly reduced. The following measures ca

  • Siemens SIMATIC Ident, Readers 5.3 SIMATIC RF310R - second generation SIMATIC RF300 134 System Manual, 07/2016, C79000-G8976-C345-0x 5.3.9 Approvals FCC information Siemens SIMATIC RF310R (MLFB 6GT2801-1BA10); FCC ID NXW-RF310R-03 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution Any

  • Siemens SIMATIC Ident, Planning the RF300 system 4.3 Installation guidelines SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 69 Transponder RF310R reader without metal on metal flush-mounted in metal (20 mm all- round) MDS E624 1) without metal 100 95 80 on metal; distance 15 mm 90 95 85 flush-mounted in metal; distance all round 20 mm 80 75 60 1 ) Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal. 4.3.4.2 RF340R With RF300 transponders Table 4- 35 Reduction of field data due to metal, range a

  • Siemens SIMATIC Ident, Planning the RF300 system 4.4 Chemical resistance of the transponders SIMATIC RF300 92 System Manual, 07/2016, C79000-G8976-C345-0x Substance Test conditions Rating Concentration [%] Temperature [°C] Calcium nitrate, w. c. s. 20 ℃ ○○○○ c. s. 60 ℃ ○○○ Chlorine 20 ℃ - Chrome baths, tech. 20 ℃ - Iron salts, w. c. s. 60 ℃ ○○○○ Acetic acid, w. 50% 20 ℃ - Ethyl alcohol, w., undenaturated 95% 20 ℃ ○○○○ 95% 60 ℃ ○○○ 50% 60 ℃ ○○○○ Formaldehyde, w. 30

Related Products and Documents (Industrial Electrical):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Cambridge Audio AZUR 840A V2 Operation & user’s manual cambridge-audio/azur-840a-v2-ADM.pdf 20 Dec 2023 16 3.55 Mb
2 Pyle P15LCD Operating manual pyle-audio/p15lcd-ZKI.pdf 13 Aug 2022 13
3 Intel bizhub PRO C6500 Specification sheet intel/bizhub-pro-c6500-7XB.pdf 18 Mar 2024 8
4 Philips AZ 6831 Instructions for use philips/az-6831-27W.pdf 24 Feb 2023 1 0.64 Mb
5 Freestyle Focus 815 Instruction manual freestyle/focus-815-87E.pdf 11 May 2023 1 0.67 Mb
6 Marantz SR7500 Specifications marantz/sr7500-D9E.pdf 21 Jun 2023 2

Similar Resources:

  • Fluke

    HYDRA III Series

    (96 pages)
    July 2013 © 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies. 2638A HYDRA Series III Data Acquisition Unit Remote Programmers Guide www.elso.skriešenia na presné meranie …
  • Siemens

    3WN6

    (12 pages)
    13WN6Umrüstung von Festeinbauschaltern in EinschubschalterConverting fixed-mounted circuit-breakers to draw-out circuit-breakersConversion d’un disjoncteur fixe en disjoncteur débrochableConversión de interruptores fijos en interruptores extraíblesTrasformazione dall’esecuzione fissa in esecuzione estraibileOmbyggnad av en fast monterad brytare tillB …
  • Festo

    VABM-L1-***HWS1-***-GR Series

    (2 pages)
    Translation of the original instructions1 Further applicable documentsAll available documents for the product èwww.festo.com/pk.Observe further applicable documents:– Assembly instructions for separator VABD-...-B2 Safety instructions– Only assemble the product on components that are in a condition to be safelyoperated.– Do not interchange outpu …
  • M-system

    KF

    (3 pages)
    5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: [email protected] Rev.2 P. 1 / 3INSTRUCTION MANUALDELAY BUFFERMODELKF/KFSBEFORE USE ....Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.If you have any problems or question …
  • Danfoss

    ECL Comfort 210

    (24 pages)
    1Mounting GuideDanfoss District Energy VI.LG.W5.00 DEN-SMT/DKECL Comfort 210 / 310, A247 / A347 (code no. 087H3808)A247.1, ex. a:PPPPPP …
  • Rockwell Automation

    ArmorBlock MaXum 1792D-CB23

    (16 pages)
    Publication 1792D-IN054B-EN-P - April 2003Installation InstructionsArmorBlock MaXum Robot I/O Cable Base and Kempf Box Plate(Cat. No. 1792D-CB23 and -KPLT)The 23mm ArmorBlock MaXum Robot Ι/Ο Cable Base mates with 4 or 8 point modules, depending on your installation requirements, and optionally the Kempf box plate. No modification is required. Modules …

Comments, Questions and Opinions: