  • Siemens SIMATIC ET 200SP, Product overview 2.2 Properties of the AI Energy Meter 400VAC ST Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) 14 Manual, 10/2017, A5E36061895-AB 2.2 Properties of the AI Energy Meter 400VAC ST Article number 6ES7134-6PA01-0BD0 View of the module ① Module type and name ⑥ LED for supply voltage ② LED for diagnostics ⑦ Function class ③ 2D matrix code ⑧ Color identification label module type ④ Wiring diagram ⑨ Function and firmware version ⑤ LEDs for channel status ⑩ Article number Figure 2-2 View of the module AI Energy Meter

  • Siemens SIMATIC ET 200SP, Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) 54 Manual, 10/2017, A5E36061895-AB Parameters 8 8.1 Parameters Parameters of the AI Energy Meter 400VAC ST (DS 128) As a rule the AI Energy Meter 400VAC ST is already integrated in the hardware catalog of STEP 7 (TIA Portal) or STEP 7 V5.5 or higher. In this case STEP 7 (TIA Portal) or STEP 7 V5.5 or higher checks the parameterized properties for plausibility during designing. However, you can also assign parameters to the module by me

  • Siemens SIMATIC ET 200SP, Measured value data records E.3 Structure for energy counters (DS 143) Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) 106 Manual, 10/2017, A5E36061895-AB E.3 Structure for energy counters (DS 143) Energy meter data record 143 for different actions The energy meter data record 143 includes all energy meters available on the module phase-by-phase. The data record can be used for different actions: ● Reset the energy counter to user-specific value (e.g. "0") �

  • Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) 28 Manual, 10/2017, A5E36061895-AB Quick start 5 Introduction This section shows you how to read and view your first measured values on the Energy Meter 400 VAC ST in a particularly quick and easy way. Requirement You have already connected the Energy Meter to your network with one of the connection

  • Siemens SIMATIC ET 200SP, Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) 80 Manual, 10/2017, A5E36061895-AB Measured variables B Measured variables for data records and user data The following table provides an overview of all measured variables that are used in the data records and user data. Note that the format and unit differ in the evaluation of records and user data. Table B- 1 Measured variables for data records and user data Mea- sured value ID Measured variables Data type Unit Value range Connection type 1P2W 3P4W 1 Voltage UL1-N 1 REAL V 0.0 ... 300.0 ✓ ✓ 2 Voltage UL2-N 1 REAL V 0.0 ...

  • Siemens SIMATIC ET 200SP, Energy counters 7.4 Reset energy counter Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) Manual, 10/2017, A5E36061895-AB 47 2. Create a DB or instance DB and allocate the values of the data record Byte 0 and byte 1: Enter the value 01 H in Byte 0 and the value 00 H to Byte 1. Byte 2 ... byte 7: Control bytes for energy counters In the control bytes for the relevant phases, specify which energy counters you want to reset. The control bytes specify for each phase (L1, L2, L3) separat

  • Siemens SIMATIC ET 200SP, Energy counters 7.4 Reset energy counter Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) Manual, 10/2017, A5E36061895-AB 45 4. Transfer the data record with the WRREC instruction. Figure 7-6 Energy counter control information DS 143 Start values You specify the moment for the application of the start values in Control byte 1 via Bit 7. After the reset the energy counters count with the specified start values (default = 0). You can change the start values for the energy counters via data record DS 143.

  • Siemens SIMATIC ET 200SP, Parameter data records A.2 Structure of the parameter data record 128 for the entire module Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) 74 Manual, 10/2017, A5E36061895-AB Module header information The figure below shows the structure of the header information for a module. Figure A-3 Module header information Module parameter block The figure below shows the structure of the module parameter block. Enable a parameter by setting the corresponding bit to "1".

  • Siemens SIMATIC ET 200SP, Energy counters 7.4 Reset energy counter Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) 44 Manual, 10/2017, A5E36061895-AB Start values After the reset the energy counters count with the specified start values (default = 0). You can change the start values for the energy counters via data record DS 143, see section Structure for energy counters (DS 143) (Page 49). You can also reset the counters on a phase-specific basis by active, reactive and apparent energy using data record 143. 7.4.3 Resetting energy counters via data record DS 143 Introduction At all the module versions you can reset the energy counters via the data record DS 143. Resetting

  • Siemens SIMATIC ET 200SP, Wiring 3.3 Current transformer selection data Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) 20 Manual, 10/2017, A5E36061895-AB 3.3 Current transformer selection data Introduction Connection via a current transformer is always required for the current measurement. Use toroids with an accuracy class of 0.5, 1 or 3. Dimensioning of the current transformer The correct dimensioning of the current transformer is important for the following reasons: ● You achieve correct results

  • Siemens SIMATIC ET 200SP, Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) 92 Manual, 10/2017, A5E36061895-AB User data variants D D.1 User data variants with 32 bytes input data / 12 bytes output data User data 30 bytes are available for transferring the measured values in a cycle at the module version 32 I / 12 Q. This module variant therefore supports dynamic switching between 11 preconfigured user data variants that contain a specific selection of measured values. For more detailed information, refer to "Selecting the module versions (Page 24)". Table D- 1 Overview of the user data variants User data User data variant

  • Measured value data records E.2 Measured value data record for base measurements (DS 142) Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) 104 Manual, 10/2017, A5E36061895-AB E.2 Measured value data record for base measurements (DS 142) Measured variables of the module The following table provides an overview of all the measu

  • Siemens SIMATIC ET 200SP, Parameter data records A.2 Structure of the parameter data record 128 for the entire module Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) Manual, 10/2017, A5E36061895-AB 79 The following table shows the module-specific error codes and their meaning for the parameter data record 128. Error code in STATUS parame- ter (hexadecimal) Meaning Solution Byte 0 Byte 1 Byte 2 Byte 3 DF 80 B0 00 Number of the data record unknown Enter a valid number for the data r

  • Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) 4 Manual, 10/2017, A5E36061895-AB Preface Purpose of the documentation This manual supplements the system manual ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293 ). Functions that generally relate to the system are described in this manual. The information

  • Siemens SIMATIC ET 200SP, Energy counters 7.3 Evaluating energy counters Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) Manual, 10/2017, A5E36061895-AB 41 7.3 Evaluating energy counters Evaluating energy counters The energy counters are evaluated by ● Using the input data of the user data variants for energy – User data variant "Total energy L1 L2 L3" (ID 249 or F9 H ) – User data variant "Energy L1" (ID 248 or F8 H ) – User data variant "Energy L2" (ID 247 or F7 H ) – User data variant "Energy L3" (ID 246 or F6 H ) ● By reading data records –

  • Siemens SIMATIC ET 200SP, Product overview 2.1 Area of application Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) Manual, 10/2017, A5E36061895-AB 13 Measuring with AI Energy Meter 400VAC ST A typical supply network of a production plant is usually divided into three voltage ranges: ● The infeed of the entire plant ● The subdistribution, for example, to individual lines within the plant ● The end consumers such as the machines in the lines. The following figure shows the measurement in an electricity supply network: Figure 2-1 Use of the AI Energy Meter 400VAC ST Advantages of the AI Energy Meter 400VAC ST The AI Energy Meter 400VAC ST ha

  • Siemens SIMATIC ET 200SP, User data variants D.1 User data variants with 32 bytes input data / 12 bytes output data Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) 94 Manual, 10/2017, A5E36061895-AB Active power L1L2L3 (ID 253 or FD H ) Table D- 3 Active power L1L2L3 Byte Allocation Data type Unit Value range Mea- sured value ID 0 User data variant BYTE - 253 (FD H ) - 1 Quality information = QQ 1 I 3 U 3 I 2 U 2 I 1 U 1 BYTE Bit string qq xx xx xx - 2 ... 3 Current L1 UINT 1 mA 0 … 65535 66007 4 ... 5

  • Siemens SIMATIC ET 200SP, Measured variables Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) 84 Manual, 10/2017, A5E36061895-AB Format Table B- 2 Format and its length in bytes Format in STEP 7 (TIA Portal) Format to IEEE Length in bytes Comment BYTE BYTE 1 byte Bit field with 8 bit WORD WORD 2 bytes Bit field with 16 bit USINT INT8 (unsigned) 1 byte Fixed-point number 8 bits without sign INT INT16 (signed) 2 bytes Fixed-point number 16 bits with sign

  • Siemens SIMATIC ET 200SP, Parameter data records A.2 Structure of the parameter data record 128 for the entire module Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) Manual, 10/2017, A5E36061895-AB 73 A.2 Structure of the parameter data record 128 for the entire module Structure of data record 128 Figure A-1 Parameter data record 128 Header information The figure below shows the structure of the header information. Figure A-2 Header information

  • Siemens SIMATIC ET 200SP, Interrupts/diagnostic alarms 9.1 Status and error display Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) 62 Manual, 10/2017, A5E36061895-AB Meaning of the LED displays The following table explains the meaning of the status and error displays. Remedial measures for diagnostic alarms can be found in the section Diagnostic alarms (Page 64). DIAG LED Table 9- 1 Meaning of the DIAG LED DIAG Meaning Off Supply voltage of the ET 200SP not OK Flashes Module not ready for operati

  • Siemens SIMATIC ET 200SP, User data variants D.1 User data variants with 32 bytes input data / 12 bytes output data Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) 100 Manual, 10/2017, A5E36061895-AB Energy L2 (ID 247 or F7 H ) Table D- 9 Energy L2 Byte Allocation Data type Unit Value range Mea- sured value ID 0 User data variant BYTE - 247 (F7 H ) - 1 Quality information = QQ 1 I 3 U 3 I 2 U 2 I 1 U 1 BYTE Bit string qq xx xx xx - 2 ... 3 Current L2 UINT 1 mA 0 … 65535 66008 4 ... 7 Active energy inflow L2 UDINT 1 Wh 0 to 2147483647 62210 8 ... 11 Active energy outflow L2 UDINT 1 Wh 0 to

  • Measured value data records E.3 Structure for energy counters (DS 143) Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0) Manual, 10/2017, A5E36061895-AB 107 Byte Measured variable Data type Unit Value range Mea- sured value ID 16...23 Active energy outflow (initial value) L1 LREAL Wh 61181 24...31 Reactive energy inflow (initial val

Related Products and Documents (I/O Systems):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 AEG KG 74 Opearting instructions aeg/kg-74-N23.pdf 27 May 2023 12 1.12 Mb
2 Sony VPD-MX10 Service manual sony/vpd-mx10-7ZD.pdf 15 Jul 2022 78 7.31 Mb
3 Electrolux ER 8126/1 B Instruction book electrolux/er-8126-1-b-I18.pdf 03 Sep 2022 20 0.58 Mb
4 Harman Kardon HD7525 Instruction manual harman-kardon/hd7525-L98.pdf 10 Jul 2023 12 1.13 Mb
5 Powerware 9120 Technical specifications powerware/9120-1IV.pdf 06 Jul 2023 5
6 Sterling Plumbing WINDHAM 402015 Specifications sterling-plumbing/windham-402015-7JK.pdf 20 Aug 2023 2 0.07 Mb

Similar Resources:

  • National Instruments

    187970E-01

    (12 pages)
    Artisan Technology Group is your source for quality new and certied-used/pre-owned equipment• FAST SHIPPING AND DELIVERY• TENS OF THOUSANDS OF IN-STOCK ITEMS• EQUIPMENT DEMOS• HUNDREDS OF MANUFACTURERS SUPPORTED• LEASING/MONTHLY RENTALS• ITAR CERTIFIED SECURE ASSET SOLUTIONSSERVICE CENTER REPAIRSExperienced engineers and techni …
  • Allen-Bradley

    1756-IB16K

    (10 pages)
    Installation InstructionsOriginal InstructionsControlLogix DC Digital I/O ModulesCatalog Numbers 1756-IB16, 1756-IB16K, 1756-IB16D, 1756-IB16DK, 1756-IB16I, 1756-IB16IK, 1756-IB16IF, 1756-IB16IFK, 1756-IB16ISOE, 1756-IB16ISOEK, 1756-IB32, 1756-IB32K, 1756-IC16, 1756-IG16, 1756-IN16, 1756-IV16, 1756-IV16K, 1756-IV32, 1756-IV32K, 1756-LSC8XIB8I, 1756-LSC8XIB8I …
  • WAGO

    I/O System 750 Series

    (130 pages)
    Modular I/O System DeviceNet 750-346 Manual Technical Description, Installation and Configuration Version 1.0.1 …
  • Automationdirect.com

    Productivity 2000 P2-04AD

    (8 pages)
    1Sales 800-633-0405 www.productivity2000.comTerminal Block sold separately, (see wiring options on page 5).Warranty: Thirty-day money-back guarantee. Two-year limited replacement. (See www.productivity2000.com for details).1–9.453V2 18.233 UNDER4 SPARE2000WARNING: To minimize the risk of potential safety problems, you should follow all applicable local a …
  • Sun Microsystems

    Fire 4810

    (2 pages)
    PleaseRecycleSun Microsystems, Inc., 4150 Network Circle, Santa Clara, CA 95054 U.S.A.650 960-1300, Fax 650 969-9131Sun Fire™ 4810 SystemsPower Supply InstallationGuideCopyright 2001 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. Third-party software, including fonttechnology, is copyrighted and licensed from Sun suppliers. Su …
  • WAGO

    I/O System 750 XTR 750-495/040-010

    (130 pages)
    Pos: 2 /Dokumentation al lgemein/Einband/Ei nband Frontseite - Handbuch; CI 2017; mit DocVar iablen (Standard) @ 28\ mod_1486477502910_0. docx @ 405388 @ @ 1 Manual WAGO I/O System 750 XTR 750-495/040-010 3-Phase POM 20KV 300A XTR 3-Phase Power Measurement; 20 kV AC; 300 A; Extreme (* only in connection with sensors according to section “Measurem …

Comments, Questions and Opinions: