Manualios.com

GE D20MX Operation & User’s Manual

GE D20MX Manual Online:

3.45, 2739 votes
GE D20MX User Manual
GE D20MX User Guide
GE D20MX Online Manual

Text of GE D20MX User Guide:

  • GE D20MX, 96 GENERAL D20MX HARDWARE USER’S MANUAL APPENDIX B: LIST OF ACRONYMS EU European Union FEFI Far End Fault FPGA Field-Programmable Gate Array GE General Electric GOF glass optical fiber HCS Hard Clad Silica HDLC High-level Data Link Control HMI Human Machine Interface (also called Graphical User Interface – GUI) Hz Hertz, unit of measure for frequency I/O Input/Output IEC International Electrotechnical Commission Standards IED Intelligent Electronic Device ILS Instrument Landing System in-lb inch-pound, unit of measure for energy IRIG-B Inter Ran

  • 26 GENERAL D20MX HARDWARE USER’S MANUAL CHAPTER 1: BEFORE YOU START Physical Environmental Software SOE time stamp accuracy Overall height 40.34 mm (1.588 in.) Width 261.87 mm (10.31 in.) Depth 160 mm (6.3 in.) D20MX weight 0.7 kg (1.65 lb) Fiber card weight 0.2 kg (0.35 lb) Battery shipping restrictions The D20MX does not contain a battery and is therefor

  • GE D20MX, CHAPTER 5: CONFIGURING THE SOFTWARE D20MX HARDWARE USER’S MANUAL GENERAL 79 4. Right-click on the D20 device you want to transfer and select Tools > Change. Result: The Change Device window appears. 5. Select type D20 and click OK. 6. Follow the steps in section: “Updating a D20 configuration to use the D20MX firmware definition with ConfigPro” on page 76.

  • APPENDIX A: DEFAULT ROLE-BASED ACCESS CONTROL MODEL D20MX HARDWARE USER’S MANUAL GENERAL 87 Table 25: Modify access flags for D20AC WESMAINT II+ display screens (Application number: 32045) Table 26: Read access flags for D20AC WESMAINT II+ display screens (Application num- ber: 32045) Table 27: Modify access flags for Prologic display (Application number: 36) Table 28: Read

  • GE D20MX, CHAPTER 2: INSTALLING THE D20MX D20MX HARDWARE USER’S MANUAL GENERAL 31 Figure 8: D20 chassis front panel - D20MX with rear fiber optic connectors Installation steps The D20MX can be installed in a non-VME (GE part number 500-0305) or VME (GE part number 500-0280) D20 chassis. If you are retrofitting an existing D20 device, See section: “Retrofitting the D20MX in an existing D20” on page 33. To install the D20MX in a D20 chassis 1. Ensure that you are sufficiently grounded to prevent ESD damage to the D20MX or other components. Se

  • GE D20MX, 30 GENERAL D20MX HARDWARE USER’S MANUAL CHAPTER 2: INSTALLING THE D20MX Figure 6: D20 chassis front panel - D20MX with Ethernet connectors Figure 7: D20 chassis front panel - D20MX with front fiber optic connectors D20 chassis D20 power supply D20MX processor D20MX cover plate D20MX cover plate filler Protective earth terminal D20 chassis D20 power supply D20MX processor D20MX cover plate D20MX cover plate filler Protective earth terminal

  • GE D20MX, D20MX HARDWARE USER’S MANUAL GENERAL 99 D20MX Processor Index A AUTOMATIC ON-LINE STARTUP TEST ............................................55 AUTOMATION APPLICATIONS ............................................................16 C CABLING D.20 Link ....................................................................................................41 Ethernet .....................................................................................................42 fiber optic .................................................................................................43 overview .........

  • GE D20MX, CHAPTER 3: CONNECTING TO DEVICES AND NETWORKS D20MX HARDWARE USER’S MANUAL GENERAL 45 You may override or disable the derived IP address by defining a host with the desired IP address. Use an IP address of 0.0.0.0 to disable the derived IP address. Define the host in the SGConfig tool > D20 Device Wizard > Define the LAN properties for this project screen (see Figure 17 for an example). Figure 17: SGConfig - example of overriding derived IP address by defining a hostname Each host consists of a host name and host address. Construct the host name by replacin

  • GE D20MX, D20MX HARDWARE USER’S MANUAL GENERAL 53 D20MX Processor Chapter 4: Powering-up and Testing Powering- up and Testing Once you have made all field wiring and communication connections and have completed the necessary hardware configuration, the next step is to power-up the D20MX and verify that it is functioning properly. Use this chapter to prepare for and correctly perform the power-up and other tests. This chapter includes: • What is needed to test: WESMAINT II+ facility, SHELL and SGConfig • How to power-up the D20MX and conduct the BOOT Test: Power

  • GE D20MX, 88 GENERAL D20MX HARDWARE USER’S MANUAL APPENDIX A: DEFAULT ROLE-BASED ACCESS CONTROL MODEL Table 29: Modify access flags for DNP DPA configuration display (Application number: 32021) Table 30: Read access flags for DNP DPA configuration display (Application number: 32021) Table 31: Modify access flags for internet statistics display (Application number: 162) Table 32: Read access flags for internet statistics display (Application number: 162) Table 33: Modify access flags for DNP serial data link display (Application number: 32013) Table

  • GE D20MX, CHAPTER 3: CONNECTING TO DEVICES AND NETWORKS D20MX HARDWARE USER’S MANUAL GENERAL 43 Table 14: Ethernet straight-through cable (RJ-45) pin 0ut Fiber optic Ethernet (for 526-3003 and 526-3005LF only) The 100BASE-FX variant of the D20MX (GE part numbers 526-3003 and 526-3005) can connect to one or two networks through two fiber-optic Ethernet connections. The data rate on each port is 100 Mbps. NOTE You must enable Far End Fault Indication (FEFI) or Loss Link Alert (LLA) in connected external devices for proper redundant operation. NOTE External switches must have Span

  • GE D20MX, CHAPTER 3: CONNECTING TO DEVICES AND NETWORKS D20MX HARDWARE USER’S MANUAL GENERAL 51 Figure 22: Redundancy wiring - single RS-232 switch panel 7% 96RXUFH$ 96RXUFH$ 96RXUFH$ 6HW$,Q 6HW$2XW 6HW$ 6HW$ 6WDWXV$ 96RXUFH% 96RXUFH% 96RXUFH% 6HW%,Q 6HW%2XW 6HW% 6HW% 6WDWXV%  6HW 5HVHW 7% 7% 6HW 5HVHW = = 7R'0;$ &RQWURO3RUW 56 7R'0;$ 6\V)DLO7% 3RZHU6XSSO\$ *(SDUWQR

  • GE D20MX, 16 GENERAL D20MX HARDWARE USER’S MANUAL CHAPTER 1: BEFORE YOU START The D20MX can be retrofitted into either a D20 3U single-node VME chassis or D20 3U non- VME chassis. In a single-node VME chassis, this one processor module replaces the previous D20 M, M++, ME, and MEII CPU cards. Due to aging printed circuit board assembly and mechanical constraints, only certain chassis from 2002 and onward can be used with a D20MX. This comprises the following chassis: • D20 VME chassis 500-0280 Release 08 or higher, • D20 Non-VME chassis 500-0305 Release 18 or higher A solid partition between the Main processor bay and accessory bay prevents access to the harness from the fiber card

  • GE D20MX, 50 GENERAL D20MX HARDWARE USER’S MANUAL CHAPTER 3: CONNECTING TO DEVICES AND NETWORKS To set up a redundant system It is recommended that you install and configure one standalone D20 unit to ensure that your configuration is valid and that device communications are operating properly. Once this is done, proceed with the installation of the redundant system. 1. Mount the D20 units in a rack and connect power and ground. 2. Mount the RS-232 switch panel. 3. Plug the connector of watchdog cable A (GE part number 977-0160) to serial connector COM 6 on the first D20 (CCU A). 4. Connect the bare leads of watchdog cable A to TB1 (position 6-8

  • CHAPTER 3: CONNECTING TO DEVICES AND NETWORKS D20MX HARDWARE USER’S MANUAL GENERAL 41 To provide higher EMC immunity and maintain CE Mark radiated emission compliance, the serial cables used for permanent serial and D.20 Link connections must comply with the following requirements: • Cables must be shielded • D-type connector covers must provide EMC shielding (e

  • GE D20MX, CHAPTER 3: CONNECTING TO DEVICES AND NETWORKS D20MX HARDWARE USER’S MANUAL GENERAL 49 Figure 21: RS-232 Switch panel A pair of LEDs marked CCU A and CCU B indicate which of the D20 units is currently active. If the hardware or software of the active unit fails, it is automatically switched offline and serial connections to the field are transferred to the standby unit. A toggle switch on the RS-232 switch panel can be used to switch the D20 devices between active and standby modes. Failover sequence If the active D

  • GE D20MX, 86 GENERAL D20MX HARDWARE USER’S MANUAL APPENDIX A: DEFAULT ROLE-BASED ACCESS CONTROL MODEL Table 23: Modify access flags for WESMAINT (Application number: 14) Table 24: Read access flags for WESMAINT (Application number: 14) Bit Position Description Administrator (2) Engineer (1) Operator (3) Observer (0) 0 Time and Date display Yes Yes Yes No 1 Peripheral Status display Yes Yes Yes No 2 Peripheral Status Detail display Yes Yes No No 3 COS Buffer display Yes Yes Yes No 4 D20 Monitor display Yes Yes Yes No 5 Digital Inputs display Yes Yes No No 6 Digital Inputs Detail display Yes Yes Yes No 7 Digital Outputs display Yes Yes No No 8 Digital Outputs Detail display Yes Yes Yes No

  • GE D20MX, INDEX D20MX HARDWARE USER’S MANUAL GENERAL 101 SOFTWARE PREREQUISITES ...............................................................61 SPECIFICATIONS communications ...................................................................................25 electric .......................................................................................................25 environment ............................................................................................26 physical .....................................................................................................26 product .................................................................

  • APPENDIX A: DEFAULT ROLE-BASED ACCESS CONTROL MODEL D20MX HARDWARE USER’S MANUAL GENERAL 89 Table 36: Read modify access flags for Modbus DCA display (Application number: 59) Table 37: Modify access flags for Modbus DPA display (Application number: 68) Table 38: Read access flags for Modbus DPA display (Application number: 68) Table 39: Modify access flags

  • GE D20MX, 36 GENERAL D20MX HARDWARE USER’S MANUAL CHAPTER 2: INSTALLING THE D20MX Grounding the D20MX Surge and noise suppression components used on the D20MX are designed to prevent nuisance operation and damage to internal components. To ensure correct protective operation, the earth ground wire (14AWG green wire) on the D20 chassis must be connected to a low impedance ground rail of a secondary cabinet or rack. When making ground connections, ensure that all surfaces that are used for grounding are free of dirt, residue and corrosion. Do not power up the D20 before establishing a proper protective earth connection. Unpacking the D20MX Carefully remove the D20MX from it

  • GE D20MX, D20MX HARDWARE USER’S MANUAL GENERAL 103 Modification Record Version Revision Date Author Change Description 1.00 0 October 17, 2012 R. Rees Original release of this document. 1 November 6, 2012 R. Rees Updated D20 applications table and added Firmware/FPGA versions table. 2 November 23, 2012 R. Rees Added sections for: Update to the SAN0001 firmware option, Transfer D20/ D200 configurations to the D20MX, and Updating D20/D200 Configurations to use the D20MX firmware definition with ConfigPro. Added an Appendix for Resetting a read/write user password.

  • GE D20MX, CHAPTER 3: CONNECTING TO DEVICES AND NETWORKS D20MX HARDWARE USER’S MANUAL GENERAL 47 RS-232 The RS-232 port on the D20MX is used to access the WESMAINT II+ facility and to transfer code and configuration data to the D20MX. You can use a VT100-compatible terminal or terminal emulation program to directly access the WESMAINT II+ facility. SGConfig's Terminal Emulator is an example of a suitable terminal emulation program. The RS-232 port is connected to the D20MX front panel and is also routed to

  • GE D20MX, 40 GENERAL D20MX HARDWARE USER’S MANUAL CHAPTER 3: CONNECTING TO DEVICES AND NETWORKS Figure 15: D20MX front panel with front access fiber optic connectors Figure 16: D20MX front panel and fiber optic card with rear access fiber optic connectors General cabling requirements Table 10 lists the cables required to connect to the D20MX: Table 10: Connection cables Fiber Optic Port 1 Fiber Optic Port 2 RS232 Serial Port Operational Status LEDs USB Port (not supported) Port Status LEDs Fiber O

More Instructions:

DOWNLOAD
DOWNLOAD

Related Products and Documents (Processor):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Xerox Phaser 6200N Parts list xerox/phaser-6200n-SAB.pdf 02 Mar 2024 47 1.85 Mb
2 Travis Industries 36DV Owner's manual travis-industries/36dv-KA3.pdf 25 Dec 2023 40 1.16 Mb
3 Martin Audio W8CT Specification sheet martin-audio/w8ct-J54.pdf 25 Jul 2022 1
4 Philips 14G8512 Operating instructions manual philips/14g8512-2EO.pdf 30 Mar 2023 12 0.29 Mb
5 TV One 1T-DA-462 Instruction manual tv-one/1t-da-462-OI3.pdf 22 Nov 2022 6
6 Indesit WIL143UK User manual manual indesit/wil143uk-FET.pdf 16 Jan 2024 16

Similar Resources:

  • IEI Technology

    Rocky-3702EV

    (48 pages)
    October 30, 2003 ©Copyright 2003 by ICP Electronics Inc. All Rights Reserved. ROCKY–3702EV CeleronTM & Pentium III Processor With VGA & Ethernet SBC User Manual Version 6.0 …
  • Avenview

    DVI-SPLITPRO-2X

    (24 pages)
    VIDEO WALLS VIDEO PROCESSORSVIDEO MATRIX SWITCHESEXTENDERS SPLITTERS WIRELESSCABLES & ACCESSORIESControl Your VideoAdvanced Dual Screen Multiviewer© 2015 Avenview Inc. All rights reserved.The contents of this document are provided in connection with Avenview Inc. (“Avenview”) products. Avenview makes no representations or warranties with respect to …
  • HP

    xw4550

    (1 pages)
    Windows Vista downgrade FAQHP Z Workstation and HP xw Workstation seriesThis document provides answers to commonly asked questions about the Microsoft Vista® Businessdowngrade product for HP workstations. The downgrade product enables you to use Microsoft XP™Professional as your operating system.Question AnswerWhere do I get the CD to install the downgrad …
  • HP

    D7171A - NetServer - LPr

    (6 pages)
    HP NetServer LH Plus andHP NetServer LH Pro Seriesdata sheetBest-in-class departmentalserversIf your organizations computingneeds range from file sharing andhigh-speed communications, to database and business-criticalapplications, theres no better sol-ution than HP NetServer LH Plusand LH Pro servers. These best-in-class servers feature an advanced PC …
  • SMART

    MOD IIB

    (15 pages)
    Copyright 1995 by SMART Devices Inc.5945 Peachtree Corners East Norcross, GA 30071-1337Table of ContentsSECTION 1 INTRODUCTION ..............................................................2SECTION 2 FEATURES.......................................................................2SECTION 3 CARD DESCRIPTION...................................................... …
  • Onkyo

    ED-205

    (20 pages)
    AV Surround ProcessorED-205AV SURROUND PROCESSOR STANDBY/ONSTANDBYEFFECT MODEMASTER VOLUMEMULTI CH INPUTLINEVIDEO-1/2ED-205POWEROFFONInstruction ManualThank you for purchasing the ONKYO AV SurroundProcessor.Please read this manual thoroughly before makingconnections and turning on the power.Following the instructions in this manual will enable youto obtain o …

Comments, Questions and Opinions: