Manualios.com

Truma Saphir comfort RC AU Operating Instructions Manual

  • Saphir comfort RC AU Air Conditioner
  • mabHtfpA1T3ow
  • Operating Instructions Manual
  • PDF / Adobe Acrobat Reader
  • 12

Truma Saphir comfort RC AU Manual Online:

3.65, 1240 votes
Truma Saphir comfort RC AU User Manual
Truma Saphir comfort RC AU User Guide
Truma Saphir comfort RC AU Online Manual

Text of Truma Saphir comfort RC AU User Guide:

  • 2 3b 3b 3b 3a 5 4 2b 2a 1 Saphir comfort RC AU Table of contents Symbols used ..................................................................... 2 Safety instructions ............................................................. 3 Notes on using air conditioning systems ....................... 3 Operating instructions Remote control ................................................

  • Truma Saphir comfort RC AU, 3 Safety instructions Repairs may only be carried out by an expert! To avoid transportation damage, the device may only be dispatched if the Truma Service Centre in Germany or the respective authorised service partner has been consulted beforehand. The power supply must be disconnected from the mains (all poles) before opening the housing. The 230 V, T 6.3 A H-type (slow, IEC 127) device fuse can be found on the electronic control unit in the device, and must always be replaced with an identical fuse. The device fuses and connection cables must only be replaced by

  • Truma Saphir comfort RC AU, 4 Always observe the operating instructions and the “Safety instructions” prior to starting! The vehicle owner is responsible for correct operation of the appliance. Remote control The symbols in the display are visible depending on the settings. Sleep function (in cooling mode only) Ultra-quiet fan operation Setup button Tuning the remote control and the IR receiver Mode Operating mode selection button – Cooling – Heating – Automatic – Circulated air Temperature selection buttons 16 – 31 °C In 1 °C steps On / O switch Re

  • Truma Saphir comfort RC AU, 5 IR receiver and manual on / off There is an additional pushbutton on the IR receiver (m), with which the unit can also be switched on and off without the remote control (e.g. with a ballpoint pen). If the unit is switched on using this pushbutton, the system is au- tomatically reset to the factory settings (automatic mode 22 °C). IR receiver / function indicator m LED 1 LED 2 LED 3 Fig. 4 LED 1 blue – illuminated – (cooling mode) LED 1 blue – flashing – (cooling mode, compressor start-up) LED 2 yellow – illuminated – (heating mode) LED 2 yellow – flashing – (heating mode, compressor start-up) LED 3 red – flashing – (data t

  • Truma Saphir comfort RC AU, 6 The time always appears on the display. The time must be reset after changing the batteries or after a daylight saving time change. Timer ON / OFF The On / Off time of the air conditioning system can be set in advance for a minimum of 15minutes to a maximum of 24 hours, starting from the current time, using the integrated timer The device must be switched on using the remote control in order to program it. Set required operating mode and room temperature. Then select TIMER ON or TIMER OFF using

  • Truma Saphir comfort RC AU, 7 Technical data Determined on the basis of EN 14511 or Truma test conditions Designation Saphir comfort RC AU, comfort air conditioning system Number of structural units 1 Dimensions L x W x H 628 x 400 x 290 mm Weight approx. 23.5 kg Power supply 230 V – 240 V ~, 50 Hz Maximum cooling power 2.4 kW Heating power 1.7 kW Effective power consumption 0.98 kW Starting current 20 A (150 ms) Power consumption 4.2 A / 35 °C Protection class IP X5 Energy Efficiency Rate (EER) 2.4 Volume flow (cold air) max. 380 m³/h Refrigerant R 407C Refrigerant content see type plate

  • Truma Saphir comfort RC AU, 8 Installation dimensions The dimensions are in mm. Ø 50 KO Saphir comfort RC LA HW HW LE 620 186 301 400 197.5 74 96 213.5 81 15 122 28 10 Ø 50 KO 488 Fig. 11 Truma warranty policy The warranty is given by Service Australia for 12 months from the date of purchase against any defect arising from faulty materials or workmanship. Repairs will be carried out during normal business hours only by Service Australia, or its duly authorised service agents, and are subject to the warranty conditions and excl

  • Truma Saphir comfort RC AU, 9 The device must only be installed and repaired by an expert. Read the installation instructions carefully before commencing the work, and then com- ply with them! Scope of delivery – 1 Saphir comfort RC AU – 1 Remote control with batteries – 1 IR receiver – 4 Fastening brackets with screws, 1 clamping strap – 2 Condensation traps – 2 Floor grilles – 1 Installation template – 1 set of operating instructions / installation instructions Intended use This device has been designed for installation in motor homes and caravans and is intended for use i

  • 10 Insert connections (11) for condensation drain (KO) from above. Seal connections (11) for condensation drain all round from below using body sealant. When installing the unit, please ensure that the connections (11) of the condensation drain are lo- cated in the recess in the floor of the vehicle. Otherwise there is a risk of water penetrating the interi

  • Truma Saphir comfort RC AU, 11 Installing the IR receiver The receiver (12) should preferably be fitted to the wardrobe in such a way that the remote control can be pointed at it with- out obstructions (length of connector cable 3 m). A 3 m cable extension is available if necessary (part no. 40090-89100). If the receiver cannot be flush-mounted, Truma can sup- ply an on-surface frame (13) – part no. 40000-52600 – as an accessory on request. Drill Ø 55 mm hole. Lead IR receiver cable (17) through hole towards the rear and secure rece

  • Truma Saphir comfort RC AU, 40090-00041 · 00 · 06/2018 · In Australia, always notify the Service Australia if problems are encountered; in other countries the relevant service partners should be contacted (see www.truma.com). Having the equipment model and the serial number ready (see type plate) will speed up processing. Service Australia Telephone: +61 1300 07 2018 E-Mail: [email protected] Leisure-Tec Australia Pty. Ltd. 50 Metrolink Circuit, Campbellfield, VIC 3061 Australia ©

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Genesis GLSDF36A Operator's manual genesis/glsdf36a-55L.pdf 27 Sep 2023 28
2 ISHIDA INS-100 9k Operator's manual ishida/ins-100-9k-G38.pdf 18 Sep 2022 5
3 Samsung RF267ABBP/XAA Manual de usuario samsung/rf267abbp-xaa-S8U.pdf 08 Sep 2022 44 11.11 Mb
4 Fisher & Paykel DD603B Operation & user’s manual fisher-paykel/dd603b-94T.pdf 31 Aug 2022 40 1.94 Mb
5 Craftsman 315.17250 Owner's manual craftsman/31517250-21M.pdf 13 Jun 2023 8
6 Craftsman 917.276813 Operator's manual craftsman/917-276813-OA7.pdf 28 Jan 2024 64 5.69 Mb

Similar Resources:

  • Haier

    HSU18XH7-G - Ductless Split Indoor Wall Mount Unit Heat Pump

    (60 pages)
    SERVICE MANUALOrder No.$&69ON/OFF -SeriesModel No. HSU-18HEK13/R2EKHSU-24HEK13/R2Haier GroupThis service information is designed for experienced repair technicians only and is not designed for use by the general public.It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting t …
  • EINHELL

    MKA 2001M

    (48 pages)
    BedienungsanleitungKlimagerätOperating InstructionsAir ConditionerMode dʼemploiClimatiseurGebruiksaanwijzingKlimatiseringstoestelIstruzioni per lʼusoClimatizzatoreArt.-Nr.: 23.601.15 I.-Nr.: 01016MKA 2001MAnleitung MKA 2001M_SPK1:_ 28.02.2007 14:57 Uhr Seite 1 …
  • Mitsubishi Electric

    MLZ-KP09NA

    (40 pages)
    No. OBH802REVISED EDITION-AModelsMLZ-KP09NA - U1MLZ-KP12NA - U1MLZ-KP18NA - U1INDOOR UNITMLZ-KP09NAMLZ-KP12NAMLZ-KP18NASERVICE MANUALOutdoor unit service manualMXZ-C NA, MXZ-C NAHZ Series (OBH702, OCH573)PARTS CATALOG (OBB802)CONTENTS1. TECHNICAL CHANGES ··································· 22. PART NAMES AND FUNCTI …
  • Daikin

    FTXG20LV1BW

    (404 pages)
    DAIKIN ROOM AIR CONDITIONEROPERATION MANUALMODELSFTXG20LV1BWFTXG25LV1BWFTXG35LV1BWFTXG50LV1BWFTXG20LV1BSFTXG25LV1BSFTXG35LV1BSFTXG50LV1BSEnglishDeutschFrançaisNederlandsEspañolItalianoEλληνικάPortuguêsPyccкийТürkçe00_CV_3P357704-1.indd 100_CV_3P357704-1.indd 1 12/19/2013 1:13:53 PM12/19/2013 1:13:53 PM …
  • Hotpoint

    KCM10

    (8 pages)
    .0—..Howtogetthe bestfromo01AdapterPlug3AirDirection5Air Filter6ApplianceRegistration2CareandCleaning6CondenserCoils“6ControlSettings4,5Electric~Requirements3Energy-SavingTips 2ExtensionCords3GrilleandCabinet 6Grounding3ModelandSerialNumbers2ProblemSolver 7PowerSaver4RepairService 7SafetyInstructions2Warranty BackCoverUseandCareofmodelsKW1OKW1lKW12!... . …
  • Kooltronic

    ACCESS Series

    (15 pages)
    Keep This ManualWith Air ConditionerAIR CONDITIONEROPERATOR'S MANUALCAUTIONBEFORE INSTALLING ANDUSING THIS AIR CONDITIONER,IT IS IMPORTANT THAT THISMANUAL BE READ ANDUNDERSTOOD THOROUGHLYKOOLTRONIC, INC.30 Pennington-Hopewell RoadPennington, NJ 08534609•466-3400FAX: 609•466-1114www.kooltronic.com900-039-105 (5/21)(CDR: 20322)Find additional informat …

Comments, Questions and Opinions: