Text of Resolution RE214T 2GIG User Guide:

  • Resolution RE214T 2GIG, I N S T A L L G U I D E I Smoke Alarm is a fire-protection device that alarms when it detects smoke or temperatures above 135°F (57°C). Features • UL217 and ULC531 listings • Smoke and heat detection • 5 year warranty Quick Start Guide 1. Remove the mounting plate. 2. Pull the battery tab. 3. Restore the mounting plate and twist it fully onto the smoke alarm. Note: Enrollment is possible only if the mounting plate is twisted onto the smoke alarm. 4. Enroll the smoke alarm by placing the panel into wireless enrollment mode and then holding down the smoke’s test button until the smoke alarm beeps. Panel Questions Smoke Selections Sensor Type [09] 24-hour 

  • The Alarm will emit a short beep and flash the Yellow LED when it becomes partially depleted. Check the date when the Alarm should be replaced which is given on the sidewall of the Alarm. When electronic self testing indicates that the battery is becoming low the Alarm will beep and the yellow LED will flash at the same time (about every 48 seconds) t

  • Resolution RE214T 2GIG, benefits that the user is reminded every 10 minutes by two short beeps that the Alarm needs to be replaced and that if the problem clears the Alarm will return to detecting fire). 1.2.3. Faulty smoke chamber In the unlikely event of the smoke sensing chamber becoming defective, the Alarm will give 2 short beeps with 2 yellow LED flashes every 48 seconds. The Alarm must then be replaced. If it is not convenient to replace it immediately, pressing the test button will silence the beeps and stop the yellow LED flashing for 12 hours. This can be repeated as required. 2. Location and Positioning Introduction Congratulations on purchasing a Smoke Alar

  • Resolution RE214T 2GIG, room is the most likely place for a fire to start at night, followed by the kitchen (where a Heat Alarm is recommended) and then the dining room. Consideration should be given to installing Smoke Alarms in any bedrooms where fires might occur, for instance, where there is an electrical appliance such as an electric blanket or heater, or where the occupant is a smoker. In addition, consideration should be also given to installing Smoke Alarms in any rooms where the occupant is unable to respond very well to a fire starting in that room, such as an elderly or sick person or a very young child. Ch

  • Resolution RE214T 2GIG, • Near a decorative object, door, light fitting, window moulding etc., that may prevent smoke from entering the Alarm. • Surfaces that are normally warmer or colder than the rest of the room (e.g. attic hatches). Temperature differences might stop smoke from reaching the Alarm. • Next to or directly above heaters or air conditioning vents, windows, wall vents etc. that can change the direction of airflow. • In very high or awkward areas (e.g. over stairwells) where it may be difficult to reach the Alarm (for testing, hushing or battery replacement). • Locate the Alarm at least 1m (39”) from dimmer contr

  • 3. Get out as fast as you can. Do not stop for packing. Have a prearranged meeting place outside for all family members. Check everybody is there. 4. Call the Fire Brigade from a neighbour’s house or mobile phone. Remember to give your name and address. 5. NEVER re-enter a burning house. 4. Alarm Limitations Limitations of Smoke Alarms While Smoke Alarms are ex

  • Resolution RE214T 2GIG, chimney, in a wall cavity, or if the prevailing air draughts carry the smoke or heat away. Installing Smoke Alarms on both sides of closed doors and installing more than one Alarm as recommended in this leaflet very significantly improve the probability of early detection. • The Smoke Alarms may not be heard. • A Smoke Alarm may not wake a person who has taken drugs or alcohol. • The Alarms may not detect every type of fire to give sufficient early warning. They are particularly ineffective with: fires caused by smoking in bed, escaping gas, violent explosions, poor storage o

  • Resolution RE214T 2GIG, Alarm (see Figure 7b). Figure 7a - How to Tamperproof BREAK OFF SMALL PILLAR Figure 7b - How to Remove PUSH UP CATCH & TWIST ALARM ANTI-CLOCKWISE TO REMOVE If necessary it is possible to further secure the Alarm by using a No.2 or No.4 (2 to 3mm) (1/8”) diameter - not supplied) self tapping screw 6 to 8mm (1/4”) long (see Figure 7d), to firmly lock the Alarm and its mounting plate together (see Figure 7c). Figure 7c TAMPERPROOF SCREW Figure 7d 6 to 8 mm 2 to 3 mm SELF TAPPING SCREW Attach the Alarm

  • Resolution RE214T 2GIG, Replace battery with Panasonic CR123A, use of another battery may present a risk of fire or explosion. 7.4 Cleaning your Alarm Clean your Alarm regularly. Use a soft bristle brush or the brush attachment of your vacuum cleaner to remove dust and cobwebs from the side slots where the smoke enters. To clean the cover, wipe with a damp cloth and dry thoroughly. WARNING: Do not paint your Alarm. Other than the maintenance and cleaning described in this leaflet, no other customer servicing of this product is required. Repairs, when needed, must be performed

  • Resolution RE214T 2GIG, Figure 8b Figure 8c Figure 8d Figure 8e Figure 8f 8.6 Smoke Alarm Automatic Self-Test The smoke chamber in the Smoke Alarms automatically tests itself every 16 seconds. If the chamber is degraded it will beep twice every 48 seconds with 2 yellow LED flashes at the same time. If this happens clean the unit. If the beeping persists and the beep does not coincide with a yellow light flash, return the unit for service (see Section 5 - Getting Your Alarm Serviced). 8.7 Dust and Insect Contamination All Smoke Alarms and particularly the optical (photoelectric) type are prone to dust and insect ingress which can cause false alarms. The latest design, m

  • Resolution RE214T 2GIG, 11 • Press the Test/Silence button on the Smoke Alarm causing the Alarm (this can be identified as the Alarm with the red light flashing rapidly) – this will silence the Smoke Alarm for 10 minutes (and also silence all other interconnected Alarms in the system). The Alarm fails to sound when the Test button is pressed • Check the age of the unit - see the “replace by” label on side of unit. • If necessary replace the battery or batteries with Panasonic CR123A. 9. System Compatibility and Wireless Verification Smoke alarm model RE214T has

  • Resolution RE214T 2GIG, Pro Tip Pressing the test button on the smoke alarm will beep both the panel and smoke alarm. Specications Physical Housing Dimensions Weight with Batteries Mounting Fastener 4.7 x 1.8 inches (12.0 x 4.6 centimeters) 7.36 ounces (210 grams) #6 screws and anchors (provided) Environmental Operating Temperature Maximum Humidity 40°F to 100°F (4.4°C to 37.8°C), Long Term 15% to 95% non-condensing relative humidity Sensor Specications Frequency Replacement Batteries Transmitted Indications Loudness Smoke Sensitivity Heat Sensor 345 MHz Two Panasonic CR123A Low Battery, Supervision 85 dB

Related Products and Documents (Smoke Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Komando 13000:13580 Operation & user’s manual komando/1300013580-51J.pdf 06 Apr 2024 14
2 M2 Antenna Systems 8-30LP9 Assembly manual m2-antenna-systems/8-30lp9-R36.pdf 03 Jun 2023 13
3 COMSOL SP150DP Operation & user’s manual comsol/sp150dp-E3Z.pdf 09 Nov 2023 1
4 Canon imageRUNNER C3100 N Printer Printer manual canon/imagerunner-c3100-n-printer-Z66.pdf 28 Oct 2022 158 10.38 Mb
5 Sansei TS4120 Service manual sansei/ts4120-M62.pdf 09 Mar 2023 26
6 August DTA310 Operation & user’s manual august/dta310-8ES.pdf 05 Oct 2023 4

Similar Resources:

  • Siemens

    DELTA reflex SD9L

    (18 pages)
    251653.41.18 "DS 03 " Seite 1 von 3 Page 1 of 3 Produkt- und Funktionsbeschreibung Product and Applications Description Der DELTA reflex Rauchmelder SD9L ist für den Einsatz im Wohn- und Geschäftsbereich konzipiert, überall dort, wo keine Brandmeldeanlage vorgeschrieben ist. Der Rauchmelder erkennt frühzeitig den bei Bränden …
  • Teletek electronics

    SensoIRIS S130

    (2 pages)
    SensoIRIS S130EnglishEspañolDeutscheБългарскиATTENTION: Read carefully this installation Instructions before installing the device! This manual is subject to change without notice! SensoIRIS S130 is аn addressable optical-smoke detector designed for installing in addressable fire alarm systems supporting TTE communication protocol. The detector i …
  • Bosch

    FAD?420?HS?EN

    (210 pages)
    Duct Smoke DetectorFAD‑420‑HS‑ENInstallation Guidecs českýde deutschel ελληνικάen englishes españolfr françaishu magyarulit italianonl nederlandspl polskipt portuguêsru русскийtr türkçe …
  • Vivanco

    SD 5Y

    (96 pages)
    Page /SeiteD Bedienungsanleitung 2 –6GB Operating instructions 7 – 11F Mode d’emploi 12 – 16E Manual de Instrucciones 17 – 21I Istruzioni per l’uso 22 – 26NL Gebruiksaanwijzing 27 – 31PL Instrukcja obsługi 32–36P Manual de instruções 37 – 41DK Betjeningsvejledning 42 – 46SD 5YPage /SeiteN Bruksanvisning 47 – 51S Bruksanvisning 52 � …
  • Apollo

    51000-600

    (28 pages)
     ͷͳͲͲͲǦ͸ͲͲȀͷͳͲͲͲǦ͸ͲͳǡATTENTION: � …
  • Comelit

    41RML100

    (2 pages)
    Passion.Technology.Design.Addressed multi-criteria smoke/heat detector with isolator; Rivelatore multicriterio fumo/calore indirizzato con isolatore;Multi-criterium detector rook/warmte, met adres met isolator;Detector multicriterio humo/calor direccionado con aislador;Détecteur multicritère fumée/chaleur adressé avec isolateur41RML100 201293DoP No: 049E …

Comments, Questions and Opinions: