Manualios.com

Parker BAC-4015 Operation & User’s Manual

Parker BAC-4015 Manual Online:

3.05, 1909 votes
Parker BAC-4015 User Manual
Parker BAC-4015 User Guide
Parker BAC-4015 Online Manual

Text of Parker BAC-4015 User Guide:

  • Parker BAC-4015, Breathing Air Purifier BAC-4015 Original Language User Guide aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding EN

  • Parker BAC-4015, 1 Table of Contents 1 Safety Information ........................................................................................................................................................................................2 2 Description ....................................................................................................................................................................................................3 2.1 Technical Specification..........................................................................................................................

  • 2 1 Safety Information Do not operate this equipment until the safety information and instructions in this user guide have been read and understood by all personnel concerned. USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and oth

  • Parker BAC-4015, 3 2 Description The Parker domnick hunter BAC-4015 is a fully portable pneumatically controlled air purification system designed to provide breathing quality air to a higher level than specified in EN12021 for oil mist, vapour, odour and particulate removal. The BAC-4015 will also remove carbon monoxide (CO) and reduce carbon dioxide (CO2) to fully meet EN12021 and other international specifications. The BAC-4015 breathing air purifier utilises 5 separate stages of compressed air treatment, combined together in a compact and robust housing. 1st Stage - Grade AA - high efficienc

  • Parker BAC-4015, 4 2.2 Weights and Dimensions 2.3 Receiving and Inspecting the Equipment The equipment is supplied in a sturdy wooden crate designed to be moved using a forklift truck or pallet truck. On delivery of the equipment check the crate and its contents for damage. If there are any signs of damage to the crate, or there are any parts missing please inform the delivery company immediately and contact your local Parker domnick hunter office. 2.3.1 Unpacking the Equipment The panels of the crate are secured using nails. Starting with the top, carefully remove each panel in turn and store them safely for future use. 2.3.2 Lifting and handling Lifting handles have been provided on the equipment, howeve

  • Parker BAC-4015, 5 2.4 Overview of the Equipment Ref Description Ref Description 1 BAC-4015 Lockable door c/w keys 8 G 3/8 Regulator 2 Inlet adaptor 9 Hours Run Meter 3 Outlet manifold 10 Inlet pressure gauge 4 AC Grade filter 11 Outlet pressure gauge 5 HC Grade filter 12 Audible warning device 6 AIR PACK 2000 Dryer 13 Flow limiting orifice 7 AA0003G Filter 10 11 1 2 4 5 8 3 13 12 7 6 9

  • Parker BAC-4015, 6 3 Connecting and Operating the Equipment 3.1 General Installation Requirements Before the BAC-4015 is installed, the piping should be purged with clean dry air to remove any loose debris and/or water from the line. Downstream piping must be of a type approved and specified for breathing air applications. Inlet connection to the BAC-4015 is made by a G1/2 BSPP internally threaded pipe connection to IS0228 (BSPP) for use with parallel or taper fittings. The three outlet connections are G1/4 BSPP internally threaded to IS0228 (BSPP)

  • Parker BAC-4015, 7 3.3 Safety Features The following safety features are incorporated as standard in the BAC-4015 and must not be disconnected, removed, or bypassed in any manner. 3.3.1 Audible warning of system failure If the BAC-4015 is depressurised without the operator's knowledge (e.g. compressor failure or system pressure loss), a warning whistle will sound when the pressure drops to below 4 bar g (58 psi g) (minimum operating pressure). 3.3.2 Flow limiting orifice This device limits the outlet flow rate proportionally to the line pressure thus ensuring that the volumetric air flow rate of

  • Parker BAC-4015, 8 4 Preventative Maintenance Kits 4.1 Service Intervals Key: Description of Service Required Service recommended every: Component Operation Week Monthly 3-month 12-month Complete Assembly Check for air leaks. Filtration Check the pressure gauges during purging for excessive back pressure. Filtration Replace the adsorption filter elements - Activated Carbon (1) Recommended Service (1) Unlike oil aerosol removal filters which are changed annually to guarantee compressed air quality, the lifetime of an oil vapour removal filter can be attributed to various factors and require more frequent changes. Factors affecting

  • Parker BAC-4015, 9 Preventative Maintenance Kits Recommended upon detection of vapour, odour or taste - Maximum of 12 months Recommended every 12 months Recommended every 36 months Description Catalogue Number Contents Kit: Valve Overhaul 608233690 Inlet Valve Kit (Catalogue No.608233671) Outlet Valve Kit (Catalogue No.608233674) Exhaust Valve Kit (Catalogue No.608233677) Control Valve Kit (Catalogue No.608233680) Description Catalogue No. Contents Order Qty 015AC 015AC AC cartridge 1 015HC 015HC HC cartridge 1 Note. One kit is required for each

  • Parker BAC-4015, 10 Desiccant Column Seal Kits Snowstorm Filler Description Catalogue Number Contents Kit: Outlet Valve 608233674 Check valves Valve seats and guides Circlips Associated seals Outlet Valve Kit Description Catalogue Number Contents Kit: Exhaust Valve DM012 - 040 608233677 2/2 Isolator valve Exhaust barrel nipple 90 o elbow 1/8” - 4mm swivel elbow Exhaust Valve Kit Description Catalogue Number Contents Kit: Control Valve DM012 - 080 608233680 Pilot Valves Fixing screws Control Valve Kit Note. Ensure that the dryer is filled using a Snowstorm filler and rep

  • 11 Image shows a coalescing filter with an automatic drain The adsorption fllter is fitted with a manual drain and does not require changing. 1 4 4 1 2 2 3 Replacing the Elements 1 Unscrew the filter bowls (1) and remove the used elements (2). Note. We recommend the use of gloves when touching contaminated elements. 2 Unscrew the automatic drain (3) and fi

  • Parker BAC-4015, 12 ELEMENTS Parker filters are designed to produce clean compressed air, gas and liquid to the highest industry standards. To maintain impeccable results, Elements within the filter must be replaced annually. Choosing the Parker brand means you can be assured that Elements are readily available, affordable and the most energy efficient product of its kind on the market. The elements are also supplied in 100% recyclable packaging. An additional advantage of purchasing Parker Elements is that you will reduce your company’s carbon footprint by 190kg. T

  • Parker BAC-4015, Declaration of Conformity EN Parker Hannifin Manufacturing Limited, domnick hunter Filtration and Separation Dukesway, TVTE, Gateshead, Tyne & Wear, NE11 0PZ. UK Breathing Air Purifier BAC-4015 Directives 97/23/EC Standards used Generally in accordance with ASMEVIII Div 1 : 2004. PED Assessment Route : N/A EC Type-examination Certificate: Notified body for PED: N/A Authorised Representative Derek Bankier Divisional Quality Manager Parker Hannifin Manufacturing Limited, dhFNS Declaration I declare that as the authorised representative, the above information in relation to the supply / manufacture of thi

  • Parker BAC-4015, Parker Hannifin Manufacturing Limited domnick hunter Filtration and Separation Division Dukesway, Team Valley Trading Est Gateshead, Tyne and Wear England NE11 0PZ Tel: +44 (0) 191 402 9000 Fax: +44 (0) 191 482 6296 www.parker.com/dhfns © Parker Hannifin Corporation. All rights reserved. Catalogue: 176480300 11/13 Rev: - AE – UAE, Dubai Tel: +971 4 8127100 [email protected] AR – Argentina, Buenos Aires Tel: +54 3327 44 4129 AT – Austria, Wiener Neustadt Tel: +43 (0)2622 23501-0 [email protected] AT – Eastern Europe, Wiener Neustadt Tel: +43 (0)2622 23501 900 [email protected] AU – Australia, Castle Hill Tel: +61 (0)2-9634 7777 AZ – Azerbaijan, Bak

Related Products and Documents (Air Cleaner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Poulan Pro PP927ESB Owner's manual poulan-pro/pp927esb-RQ1.pdf 10 Apr 2023 32
2 Insignia NSAV511 Manual d'installation rapide insignia/nsav511-942.pdf 16 Jan 2023 2
3 Winegard SK-3003 Installation manual winegard/sk-3003-G3S.pdf 23 Sep 2022 20
4 Memorex MPH6925 Owner's manual memorex/mph6925-AWJ.pdf 10 Oct 2023 24
5 Buffalo WLI-H4-D1300 Operation & user’s manual buffalo/wli-h4-d1300-N5B.pdf 22 Mar 2024 64 1.97 Mb
6 VQ MIG-3 Assembly instructions manual vq/mig-3-SF3.pdf 13 Mar 2023 12

Similar Resources:

  • Surround Air

    Multi-Tech S3000

    (5 pages)
    Multi-Tech S3000 Air PurifierInstruction Manual(Please read before using air purifier)Surround Air DivisionIndoor Purification Systems, Inc.334 Marshall Way, Suite CLayton, Utah 84041Toll Free: 888.812.1516PH: 801.444.0606FX: 801.991.4838Web: www.surroundair.comEmail: [email protected]
  • Toshiba

    CAF-G3I

    (12 pages)
    AIR PURIFIER (TABLE TYPE)OWNER’S MANUALMODELCAF-G3ICAF-G3A•Thank you for purchasing a Toshiba air purifier.•Please read and understand this manual thoroughly inorder to use this product safely.•Please keep this manual at hand for quick reference afteryou have read it. …
  • Air Quality Engineering

    MiracleAir CM-12

    (10 pages)
    C O M M E R C I A L I N D O O R A I R Q U A L I T Y S O L U T I O N SMiracle™High Performance HEPA-TypeAir CleanerMiracleAir Model CM-12 from Air Quality Engineering, Inc., is the ultimatesolution for indoor air pollution capturing both particulate and gaseouscontaminants. Odors, tobacco smoke, pollen, dust, vapors and many otherirritants are remo …
  • Lifebreath

    Lifebreath TFP3000

    (4 pages)
    1 TFP4 mounting brackets4 hanging straps2 Red, 7” collar connections4 8/32” X 3/4” sheet metal screws 8 8/32” X 3/8” sheet metal screws 4 pieces of mounting foam1 set of installation \ operating instructions1 warranty cardThe TFP is equipped with a standard power supply, on a 5’ 5” cable. Lighted ON/OFF switch.Materials SuppliedElectri …
  • Oreck

    AIR94

    (36 pages)
    OptiMaxTMAir Purier Important!Read this manual carefully, and keep for future reference.User’s GuideModel: AIR94 & AIR95The energy eciency of this ENERGY STAR qualied model is measured based on a ratio between the model’s CADR for dust and the electrical energy it consumes, or CADR/Watt.This product earned the ENERGY STAR by meeting stri …
  • MANN+HUMMEL

    TRI-KLEEN 500 UV BR

    (2 pages)
    Distributed by:TRI-DIM FILTER CORPORATION93 Industrial DriveLouisa, VA 23093www.tridim.com1-800-458-9835SCAN MEp/n: 2007-0566-S01TRI-KLEEN 500UVQuick Start GuidePre-Filter CheckOpen compartment lid.Pull out pre-filter.HEPA Filter CheckRemove bottom plate.Check wing nuts and HEPA filter. …

Comments, Questions and Opinions: