KStar UDC9101S One Operation & User’s Manual
|
KStar UDC9101S One, 9 2-4 UPSstartupandturnoff Startupoperation (1)TurnontheUPSinlinemode NOTE Verify that the total equipment ratings do not exceed the UPS capacitytopreventanoverloadalarm. a) Oncemainspowerispluggedin,theUPSwillchargethebattery,atthemoment, theLCDshowsthattheoutputvoltageis220,whichmeanstheUPSautomatically tarttheinverter.Ifitisexpectedtochangetobypass model,youcanPress
KStar UDC9101S One, 13 3. Operations 3-1 Buttonoperation 3-2 LCDdisplay Partone:Rackdisplay Thereare9interfacesavailableintheLCDdisplay. Button Function ON /ENTER Button TurnontheUPS:PressandholdONbuttonfor atleast2secondstoturnontheUPS. Confirmcurrentsettings:WhentheUPSenters thesettingmode,mustpressthisbuttonto confirmthesettingsvaluewhatyouwant,nest pressup/downbuttontochangesettings information Out�
KStar UDC9101S One, 4 When installing the equipment, it should ensure that the sum oftheleakage currentoftheUPSandtheconnecteddevicesdoesnotexceed3.5mA. 1-4 Operation DonotdisconnectthemainscableontheUPSsystemorthebuilding wiring outlet(shockproofsocketoutlet)duringoperationssincethiswouldcancelthe protectiveearthingoftheUPSsystemandofallconnectedloads. The UPS system features its own, internal�
22 Relaycard MinidrycontactcardisusedfoprovidingtheinterfaceforUPSperipheralmonitoring.The contactsignalscanreflectUPSrunningstatus.Thecardisconnectedtoperipheralmonitoring devicesviaterminalboardtofacilitatetheeffectivemonitoringofthereal-tim
KStar UDC9101S One, 3 1. ImportantSafetyWarning Importantsafetyinstructions–Savetheseinstructions Pleasecomplywithallwarnings andoperatinginstructions inthismanual strictly. Save this manual properly and read carefully the following instructions before installing the unit. Do not operate this unit before reading through all safety informationandoperatinginstructionscarefully Thereexistsdangerousvoltageandhigh�
KStar UDC9101S One, 24 Numbers 2 3 2 3 4 6 4 6 6 8 6 8 Backup time Long run unit depends on the capacity of external batteries Typical recharge time(standard modle) 4 hours recover to 90% capacity (Typical) Charging voltage 27.4 VDC ±1% 41.0 VDC ±1% 27.4 VDC ±1% 41.0 VDC ±1% 54.7 VDC ±1% 82.1 VDC ±1% 54.7 VDC ±1% 82.1 VDC ±1% 82.1 VDC ±1% 109.4 VDC ±1% 82.1 VDC ±1% 109. 4 VDC ±1% Charge current 1A or 2A 12A max, can be setting by LCD 1A or 2A 12A max, can be setting by LCD 1A or 2A 12A max, can be setting by LCD SYSTEM FEATURES Overload @35 ℃ Line Mode Battery Mode Ambient Temp.<35 ℃ 105%~110%: UPS transfer to
KStar UDC9101S One, 8 For socket-type outputs, simply connect devices to the outlets. For terminal-type input or outputs, please follow below steps for the wiring configuration: a) Remove the small cover of the terminal block b) Suggest using AWG14 or 2.1mm 2 power cords for 3KVA (200/208/220/230/240VAC models). c) Upon completion of the wiring configuration, please check whether the wires are securely affixed. d) Put the small cover back to the rear panel. Step 3 Communication connection Communication port: To allow for unattended UPS shutdown/start-up and st
KStar UDC9101S One, 11 Function Keys FunctionKey Description ESC/OFF ToexitsettingmodeOrturnofftheups UP TogotopreviousselectionOrturnontheups Down Togotonextselection ENTER/ON Toconfirmtheselectioninsettingmodeorentersettingmode LCD Display Icons Icon Function description InputSourceInformation IndicatestheACinput. Indicate input voltage, input frequency, PV voltage, battery voltageandTemp Configura
KStar UDC9101S One, 19 4. Troubleshooting IftheUPSsystemdoesnotoperatecorrectly,pleasesolvetheproblembyusingthe tablebelowandtheTroubleShootingChart. Symptom Possiblecause Remedy Noindicationandalarmeven thoughthemainsisnormal. TheACinputpoweris notconnectedwell. Checkifinputpowercord firmlyconnectedtothe mains. TheACinputis connectedtotheUPS output. PlugACinputpowercord toACinputcorrectly. Alarmcode
KStar UDC9101S One, 7 2KVA(S)-6batt /3KVA(S): 1. ACinput 2. Network/Fax/ModemSurgeProtection(option) 3. Inputcircuitbreaker 4. EPO(option) 5. USBcommunicationport(option) 6. RS-232communicationport 7. SNMPintelligentslot(option) 8. Outputreceptacles 9. BatteryTerminal 10. OutputTerminal 2-3 SetuptheUPS Step 1: UPS input connection Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords. For 200/208/220/230/240VAC models: The po
18 5 UtilityMode 6 BatteryMode 7 BatterySelf-diagnostics 8 Inverterisstartingup 9 ECOMode 10 EPOMode 11 MaintenanceBypassMode 12 FaultMode 3-5 AlarmorFaultreferencecode Eventlog UPSAlarmWarning Buzzer LED 1 RectifierFault Beepcontinuously FaultL
KStar UDC9101S One, 17 06 Bypassvoltageupperlimitsetting PressEnterbutton tochange thesetting(Thebypassvoltage upperlimitrangeis230-264Vac). PressUPbutton▲toselectthe previoussetting. PressDOWNbutton▼toselect thenextsetting. 07 Bypassvoltagelowerlimitsetting PressEnterbuttontochangethe setting(Thebypassvoltagelower limitrangeis170-220Vac). PressUPbutton toselectthe previou
KStar UDC9101S One, 10 LCD control panel introduction (1)LED(fromright toleft:“alarm”,“bypass”,“battery”,“inverter”); (2)On-LineUPSLCDdisplay;(3)Functionkeys LED Indicator Indicator Description Red OnTheUPShasanactivealarmorfault. Yellow TheUPSisinBypassmode. OnTheUPSisoperatingnormallyonbypass duringHighEfficiencyoperation. Yellow OnTheUPSisinBatterymode. Green OnTheUPSisoperatingnormally
KStar UDC9101S One, 1 Allrightsreserved. Theinformationinthisdocumentissubjecttochangewithoutnotice. Publishstatement ThankyouforpurchasingthisseriesUPS. ThisseriesUPSisanintelligent,singlephaseinsinglephaseout,highfrequency onlineUPSdesignedbyourR&Dteamwhoiswithyearsofdesigningexperienceson UPS.Withexcellentelectricalperformance,perfectintelligentmonitoringand networkfunc
KStar UDC9101S One, 15 06 UPSmodel. 07 FirmwareVersion 08 AlarmCode(Warming Message) Allalarmcodesare presentwhenabnormal behavior(s)occur(s) 3-3 UPSsetting TheUPShassettingfunctions.ThisusersettingscanbedoneunderanykindofUPS workingmode.Thesettingwilltakeeffectundercertaincondition.Belowtable describeshowtosettheUPS. Thesettingfunctioniscontrolledby4buttons(Up,Down,ON/Enter,OFF/ESC): Up▲+OFF/Down
2 TableofContents 1. ImportantSafetyWarning .................................................................................................................. 3 1-1 Transportation ............................................................................................................................ 3 1-2 Preparation ........
KStar UDC9101S One, 14 Item InterfaceDescription ContentDisplayed 01 Inputvoltage&Output voltage 02 Batteryvoltage&Battery capacity 03 Inputfrequency& Outputfrequency 04 Load 05 Environment Temperature
KStar UDC9101S One, 16 Item Settings Contentdisplay 01 Modesetting PressEnterbuttontochangethe setting(ECOorNORorCF). PressUP▲button toselectthe previoussetting. PressDOWN▼button toselect thenextsetting. 02 Outputvoltagesetting PressEnterbuttontochangethe setting(200,208,220,230,240). PressUP▲button toselectthe previoussetting. PressDOWN▼button toselect thenextsetti
Ever POWERLINE 60-33 UPS Operating manual
POWERLINE 60-33 |
Toshiba 1600EP Series UPS Instruction manual
1600EP Series |
KStar 6kVA UPS Operation manual
6kVA |
Tripp Lite OmniSmart INT 300 PNP UPS Quick installation
OmniSmart INT 300 PNP |
IBM 500 UPS Operation & user’s manual
500 |
KStar UDC9101RTS UPS Operation manual
UDC9101RTS |
GE TruVision NVR 40 UPS Operation & user’s manual
TruVision NVR 40 |
KStar GP800 UPS Operation & user’s manual
GP800 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Philips | DVDR3570H | Quick start manual | philips/dvdr3570h-PTU.pdf | 17 Oct 2022 | 2 | |
2 | Oregon Scientific | THGN132ES | Manual | oregon-scientific/thgn132es-4NB.pdf | 14 Apr 2023 | 2 | |
3 | Altec Lansing | FX5051 | Operation & user’s manual | altec-lansing/fx5051-U1C.pdf | 08 Dec 2022 | 27 | 0.74 Mb |
4 | Dymo | LabelManager 360D | Manual d'utilisation | dymo/labelmanager-360d-O42.pdf | 26 Feb 2024 | 30 | 5.06 Mb |
5 | Philips | HSB2313/93 | Operation & user’s manual | philips/hsb2313-93-Z6U.pdf | 16 Feb 2023 | 25 | 2.2 Mb |
6 | NEFF | B45E54N0GB | User manual manual | neff/b45e54n0gb-XD5.pdf | 27 Jul 2023 | 72 |
Rockwell Automation
41063-214-01 (1) 990-2230 11/20041609 Industrial Uninterruptible Power Supply1609 Unterbrechungsfreie Stromversorgung für gewerbliche NutzungOnduleur industriel 1609Sistema de alimentación ininterrumpida industrial 1609Gruppo di continuità industriale 1609No-Break Industrial 1609(1609-U500...)Installation and OperationInstallation und BetriebInstallation …
Allen-Bradley Bulletin 1609(24 pages) |
Adams
1LLIINNEE--IINNTTEERRAACCTTIIVVEELLCCDDUUPPSS650VA to 2000VAUninterruptible Power SystemUSER MANUAL2 IMPORTANT SAFETY INSTRUCTIONSWARNING : (SAVE THESE INSTRUCTIONS) This manualcontains important safety instructions. Please follow up allinstructions carefully during installation. Read this manualthoroughly before attempting to unpack, install or operate. …
650VA(4 pages) |
Xtreme
NXRTi Online UPS1000VA, 2000VA, 3000VA ModelsUser & Installaon Manualwww.xpcc.com | © 2015 Xtreme Power Conversion Corporaon. All rights reserved. (Rev 6/23/15)
…
NXRTi 1000VA(37 pages) |
Tripp Lite
Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: INTERNETOFFICE700Internet Office 700VA Tower Standby 120V UPS with USB port Highlights700VA tower 120V standby UPSMaintains AC output during power failures3 UPS battery supported outlets, 3 surge-only outletsUSB port, TEL/DSL/ethernet protec …
700(5 pages) |
Rittal
Assembly and Operation Instructions UPS System Power Modular Concept PMC 12 4,5 and 6kVA 7857.433 7857.434
…
7857.433(32 pages) |
Tripp Lite
Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: SMART1500RMXL2UASmartPro 1.5kVA 1350W Line Interactive Sine Wave UPS, Extended-run & SNMPWEBCARD options, 2URack/Tower, LCD, USB, RS232,EPO, 120V Highlights1.5kVA / 1500VA / 1350W line interactive 2U rack/tower UPS, Sine Wave120V output, …
SMART1500RMXL2UA(6 pages) |
Agrilight Control Unit Agribox SmallAgribox Small User manual and assembly instructions - Y62VFE Agribox Small, 10 |
Whirlpool Cooktop RF350BXG#738195 RF350BXG: Whirlpool Cooktop Owner Documentation RF350BXG, 20 |
Fujitsu Air Conditioner ABY54FBAGFujitsu ABY54FBAG Air Conditioner Service manual ABY54FBAG, 28 |
SmartLift Lifting Systems SL 608SmartLift Lifting Systems Operation & user’s manual (File: smartlift-sl-608-operation-user-s-manual-34, 23/10/2023) SL 608, 34 |
Yada Dash Cameras YD-V43Dash Cameras PDF Operation & user’s manual YD-V43, 26 |
Focus Processor CS-HDCS-HD (Processor ePDF User Manual, #71425S) CS-HD, 30 |
LG Air Conditioner LA090HVPUser Manual: LG LA090HVP (W56844, Upd.Mon 10.2023) LA090HVP, 62 |
LTS Scale Kitchen Appliances DR2100ALTS Scale Kitchen Appliances Technical manual (File: lts-scale-dr2100a-technical-manual-30, 28th Oct 2023) DR2100A, 30 |
sauter Test Equipment TI-A0#7VZN28: TI-A0 Test Equipment Instruction manual TI-A0, 4 |
Heatline Boiler SARGON 18S#A94UHE SARGON 18S: Heatline Boiler Owner Documentation SARGON 18S, 54 |
DeDietrich Boiler ECODENS DTG 1300-24 Eco / V130DeDietrich ECODENS DTG 1300-24 Eco / V130 Boiler Operation & user’s manual ECODENS DTG 1300-24 Eco / V130, 20 |
Oceanic Diving Instrument ATOM 2.0User Manual: Oceanic ATOM 2.0 (TEJF53, Upd.11.01.2024) ATOM 2.0, 180 |