Text of Kramer SL-280 User Guide:

  • Kramer Electronics Ltd. SL-280 – Protocol 3000 32 FACTORY Functions Permission Transparency Set: FACTORY End User Public Get: - - - Description Syntax Set: Reset device to factory default configuration #FACTORYCR Get: - - Response ~nn@FACTORYSPOKCR LF Parameters Response Triggers Notes This command deletes all user d

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Defining the SL-280 Master / Room Controller Kramer Control Brain 4 Defining the SL-280 Master / Room Controller Kramer Control Brain This section defines SL-280. Figure 1: SL-280 Master / Room Controller Kramer Control Brain Front Panel # Feature Function POWER LED Lights green when powered on. SERVICE Micro USB Connector Connect to a PC to send P3K commands and perform a firmware upgrade. IR Receiver and LED Detects IR signals for IR learning. Lights

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Remote Operation via the Web Pages 14 Configuring the Serial Ports SL-280 web pages enable you to configure each of the serial ports . To configure a serial port: 1. Click Serial Ports Setting on the left side of the web page (Figure 5 ). The Serial Ports Setting page appears. Figure 9: Serial Ports Setting Page 2. In the Port area, click a port number (1–8). 3. In the Settings area, click UDP or TCP. 4. Enter the IP Port number. 5. Enter a TCP Keepalive value between 0 and 3600 seconds. T

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Protocol 3000 34 MODEL Functions Permission Transparency Set: - - - Get: MODEL? End User Public Description Syntax Set: - - Get: Get device model #MODEL?CR Response ~nn@MODELSPmodel_nameCR LF Parameters model_name – String of up to 19 printable ASCII chars Response Triggers Notes Example #MODEL?<CR> NAME Functions Permission Transparency Set: NAME Administrator Public Get: NAME? End User Public Description Syntax Set:

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Protocol 3000 51 GPIO-VOLT Functions Permission Transparency Set: - - - Get: GPIO-VOLT? End User Public Description Syntax Set: Get: Get active voltage levels of HW GPIO #GPIO-VOLT?␠HwGpioNumber␍ Response ~nn @GPIO-VOLT␠ HwGpioNumber,Voltage ␍␊ Parameters HwGpioNum – hardware GPIO number: 1–8 Voltage – voltage 0 to 30000 millivolts Response Triggers Notes This command is not available in digital out mode Example Get HW GPIO #1 active voltage level: #GPIO-VOLT?

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Protocol 3000 35 NAME-RST Functions Permission Transparency Set: NAME-RST Administrator Public Get: - - - Description Syntax Set: Reset machine (DNS) name to factory default #NAME-RSTCR Get: - - Response ~nn@NAME-RSTSPOKCR LF Parameters Response Triggers Notes Factory default of machine (DNS) name is “SL-280-XXXXXXX”, where XXXXXXX = the last 7 digits of the serial number. Example Reset the DNS name of the device to the factory default: #NAME-RST<CR> PROT-VER Functions Permission Transparency Set: - - - Get:

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Remote Operation via the Web Pages 24 About Us Page Click About on the left side of the web page (Figure 5).to display the web page version and Kramer company information. Figure 21: About Us Page

  • Kramer Electronics Ltd. SL-280 – Protocol 3000 33 LOG-TAIL Function Permission Transparency Set: – – – Get: LOG-TAIL? End User Public Description Syntax Set: – – Get: Get the last lines of message logs #LOG-TAIL?␠line_num␍␊ Response Multi-line: ~nn@LOG-TAIL?␍␊ Line #1 content ␍␊ Line #2 content ␍␊ Etc

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Remote Operation via the Web Pages 9 Remote Operation via the Web Pages SL-280 embedded webpages enable you to define device settings, configure communication parameters, configure port settings, define security parameters, and view activity logs. The specific parameter values shown in screenshots of this manual are merely representative. To access the web pages: 1. Enter the IP address of the device (see Default Communication Parameters on page 27 ) in the address bar of your browser. The Loading page appears followed shortly by the General Info page. Figure 5: Embedded Web Pages – General Info Page The General Info page

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Protocol 3000 42 NET-GATE Functions Permission Transparency Set: NET-GATE Administrator Public Get: NET-GATE? End User Public Description Syntax Set: Set gateway IP #NET-GATESP ip_address CR Get: Get gateway IP #NET-GATE?CR Response ~nn@NET-GATESPip_addressCR LF Parameters ip_address – gateway IP address, in the following format: xxx.xxx.xxx.xxx Response Triggers Notes A network gateway connects the device via an

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Remote Operation via the Web Pages 15 Configuring I/O Ports SL-280 web pages enable you to configure each of the I/O ports . The I/O ports control devices such as sensors, door locks, audio volume and lighting control devices. To configure an I/O port: 1. Click GPIO Ports Settings on the left side of the web page (Figure 5 ). The GPIO Ports Settings page appears. Figure 10: GPIO Ports Settings Page – Digital IN Trigger Type 2. In the Port area, click the number (1–8) of the port to be configured. 3. In the Settings area, select one of the following from the Trigger type option box:

  • Kramer Electronics Ltd. SL-280 – Technical Specifications 26 Technical Specifications Inputs 1 IR Built-in sensor (for learning) Outputs 8 IR On 2-pin terminal block connectors 8 Relays Ports 8 RS-232 Serial On 3-pin terminal blocks 8 GPI/O On 2-pin terminal blocks 1 Ethernet On an RJ-45 connector 1 P3K Serial Port On a micro-USB connector Proc

  • Kramer Electronics Ltd. SL-280 – Protocol 3000 41 NET-DHCP Functions Permission Transparency Set: NET-DHCP Administrator Public Get: NET-DHCP? End User Public Description Syntax Set: Set DHCP mode #NET-DHCPSPmodeCR Get: Get DHCP mode #NET-DHCP?CR Response ~nn@NET-DHCPSPmodeCR LF Parameters mode – 0 (do not use D

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Protocol 3000 47 COM-ROUTE-ADD Functions Permission Transparency Set: COM-ROUTE-ADD Administrator Internal Get: - - - Description Syntax Set: Add a communication route tunnel connection #COM-ROUTE-ADD␠ ComNum,PortType,EthPort,EthRepEn,Timeout ␍ Get: - - Response ~nn @COM-ROUTE-ADD␠ ComNum,PortType,EthPort,EthRepEn,TCP_keep_alive_timing ␍␊ Parameters COM_Num – SERIAL port number: 1–8 portType – 1 (UDP), 2 (TCP) ETHPort – TCP/UDP port number: default = 5001–5008 ETH_rep_en – 1 (COM port

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Introduction 2 Safety Instructions Caution: There are no operator serviceable parts inside the unit . Warning: Use only the power cord that is supplied with the unit. Warning: Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only. Warning: Disconnect the power and unplug the unit from the wall before installing . Recycling Kramer Products The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC aims to reduce

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Remote Operation via the Web Pages 11 Viewing Connected Clients Information SL-280 web pages enable you to view information for client devices that are connected to SL-280 via Ethernet. To view connected clients information: 1. Click Connected Clients on the left side of the web page (Figure 5 ). The Connected Clients page appears. Figure 6: Connected Clients Page 2. View the following connected clients information: • IP – IP address • To – The RS-232

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Protocol 3000 44 TIME-SRV Functions Permission Transparency Set: TIME-SRV Administrator Public Get: TIME-SRV? End User Public Description Syntax Set: Set time server #TIME-SRV␠ mode,time_server,time_server_sync_hour ␍ Get: Get time server #TIME-SRV?␍ Response ~nn @TIME-SRV␠ mode,time_server,time_server_sync_hour,server_status ␍␊ Parameters mode – 0 (OFF), 1 (ON) time_server – time server IP address or h

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Remote Operation via the Web Pages 19 Changing the State of a Relay Port SL-280 web pages enable you to change the state of each of the relay ports . The SL-280 relay ports have the following characteristics: • Default state of relays 2–4 and 6–8 is NO (normally open) • Default state of relays 1 and 5 can be NO or NC (normally closed), depending on how they are connected to the device (see Connecting the Relay Ports on page 8 ) • Rated at 30V DC and 1A • A non-latching relay function – the contact is left in its default state when unpowered or in power up state. This means that if a rel

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Remote Operation via the Web Pages 16 Configuring a Digital Input Trigger Type Digital Input trigger mode reads the digital input of an external sensor device that is connected to the GPIO port, and detects High (upon passing Max threshold from Low state) or Low (upon passing Min threshold from High state) port states according to the user defined voltage threshold levels. To configure a digital input trigger type: 1. On the GPIO Ports Settings page, select Digital IN from the Trigger type option box (Figure 10 ). T

  • Kramer SL-280, Kramer Electronics Ltd. SL-280 – Protocol 3000 40 ETH-PORT Functions Permission Transparency Set: ETH-PORT Administrator Public Get: ETH-PORT? End User Public Description Syntax Set: Set Ethernet port protocol #ETH-PORTSPportType,ETHPortCR Get: Get Ethernet port protocol #ETH-PORT?SPportTypeCR Response ~nn@ETH-PORTSPportType,ETHPortCR LF Parameters portType – string of 3 letters indicating the port type: TCP, UDP ETHPort – TCP / UDP port number: 0–65535 Response Triggers Notes

  • Kramer SL-280, The warranty obligations of Kramer Electronics Inc. (“Kramer Electronics”) for this product are limited to the terms set forth below: What is Covered This limited warranty covers defects in materials and workmanship in this product. What is Not Covered This limited warranty does not cover any damage, deterioration or malfunction resulting from any alteration, modification, improper or unreasonable use or maintenance, misuse, abuse, accident, neglect, exposure to excess moisture, fire, improper packing and shipping (such claims must be presented to the c

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Samsung DJ68-00368Q Operating instructions manual samsung/dj68-00368q-X19.pdf 23 May 2023 16 2.77 Mb
2 Uniden BT112 Operation & user’s manual uniden/bt112-82D.pdf 10 Feb 2023 22 0.48 Mb
3 Fujitsu MHV2100AH Product manual fujitsu/mhv2100ah-61O.pdf 22 Jan 2023 280 1.77 Mb
4 Crestron CNLDAB-4A Datasheet crestron/cnldab-4a-179.pdf 08 Jan 2023 2 0.16 Mb
5 Whirlpool ADG 9190 Quick reference manual whirlpool/adg-9190-88X.pdf 24 Dec 2022 4 0.22 Mb
6 White Rodgers UNIVERSAL INTEGRATED FURANCE CONTROL 50A65-843 Installation instructions manual white-rodgers/universal-integrated-furance-control-50a65-843-5LW.pdf 25 Mar 2024 8 0.06 Mb

Similar Resources:

  • Canon

    imagePRESS C800 Series

    (312 pages)
    Quick GuideRead this guide rst.Please read this guide before operating this product. After you finish reading the guide, store it in a safe place for future reference.Guide rapideVeuillez d'abord lire ce guide.Lisez ce guide avant d'utiliser ce produit. Après avoir pris connaissance de son contenu, conservez-le dans un endroit sûr pour pouvoi …
  • Belimo

    NKQB24-1

    (6 pages)
    800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA161 M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.NKQB24-1, NKQX24-1On/Off, Fail-Safe, Operation, Direct Coupled, 24VTechnical Data NKQB24-1, NKQX24-1Power supply24VAC ±20% 50/60Hz24VDC ±10%Power consumption11W (3W)Transformer sizing22VA (class 2 power source)Electrical c …
  • Burkert

    1094 EV

    (82 pages)
    Operating InstructionsBedienungsanleitung Manuel d‘utilisation Electronic controller for vapor recoveryElektronische Steuerung zur GasrückführungCommande électronique pour la recirculation des gaz …
  • ASL INTERCOM

    TS 99

    (8 pages)
    THEATER SERIES USER MANUAL FOR THE TS 120 / TS 10 / TS 99 CUE LIGHT MASTER STATION CUE LIGHT RECEIVER CUE LIGHT PRESET CONTROL CONTENTS 1.0 GENERAL DESCRIPTION ..........................................3 2.0 UNPACKING ...............................................................3 3.0 …
  • Raychem

    FrostGuard-ECO

    (34 pages)
    FrostGuard-ECOInstallation manualMontageanleitungManuel d’installationInstallatie instructieFörläggningsinstruktionMonteringsanvisningMontagevejledningAsennusohjeNávod k instalaciNávod na inštaláciuSzerelési utasításManual de instal …
  • Overland Storage

    NEO 2000E

    (8 pages)
    10400198-004 03/2011 ©2010-11 Overland Storage, Inc. Page 1 of 8NEO® 2000e/4000e Tape LibraryThis document describes how to unpack and install an Overland Storage NEO 2000e or NEO 4000e tape library into a four-post, 32-inch depth, EIA-310 rack.WARNING: To reduce the risk of electric shock or damage to equipment, always remove any power cords while workin …