Manualios.com

Omron NE-C30-E Instruction Manual

Omron NE-C30-E Manual Online:

3.6, 732 votes
Omron NE-C30-E User Manual
Omron NE-C30-E User Guide
Omron NE-C30-E Online Manual

Text of Omron NE-C30-E User Guide:

  • Omron NE-C30-E, 4 Important safety instructions Read all the information in the instruction manual and any other literature included in the box before using the device. When using an electrical product, especially when children are present, basic safety precautions should always be followed including the following: Warning: Indicates a potentially hazardous situation which, if not avoided, could result in serious injury. (Usage) •For type, dose, and regime of medication follow the instructions of your doctor or respiratory therapist. •Do not use only water in the nebuliser, for nebu

  • 6 Important safety instructions •Do not leave the unit unattended with infants or persons who cannot express their consent. •Do not subject the device or the parts to any strong shocks such as dropping the device on the floor. •Do not distort the vaporiser head, or jab the nozzle of the medication tank with a pin etc. •Do not cover the compressor, optional rechargeable battery and ch

  • 23 EN 7.Changing the air filter On average, the air filter should be changed every 60 days or so, or when the filter has changed colour from white. 1. Pull the air filter cover off the compressor. 2. Change the air filter. Remove the old air filter with a sharp object, such as a toothpick, and insert the new air filter. 3. Put the air filter cover back in place. Notes: •Use only OMRON air fi

  • Omron NE-C30-E, 32 11.Using optional accessories 11.1Using the optional rechargeable battery Use the rechargeable battery as shown in the chart below. For details, refer to the following pages. Using the battery for the first time. When the battery has not been used for a while. Fully charge the battery. Attach the battery to the main unit and use the device. Attach the battery to the main unit. Charge indicator lights? Operate the device until the charge indicator lights. Charge the battery before using it next time. Yes No Notes: •Li

  • 35 11. Using optional accessories EN When battery power is low The charge indicator on the main unit will light when battery power is low. Please note the following points about using the device after the charge indicator lights: •Stop using the device when the charge indicator comes on. •Battery power is low and the device will cease to operate shortly after the charge indi

  • Omron NE-C30-E, 5 Important safety instructions EN •Do not use the main unit, AC adapter, optional rechargeable battery, or optional battery charger while they are wet, or connect them to a power outlet or other devices with wet hands. •The compressor, AC adapter, and optional rechargeable battery and charger are not waterproof. Do not spill water, or other liquids, on these parts. If liquid does spill on these parts, immediately unplug the power cord and wipe off the liquid with gauze or other absorbent material. •Do not immerse the main unit in water or other liquid. •Do not use or store the devi

  • 25 8. Troubleshooting EN Notes: •If the suggested remedy does not solve the problem, do not try to repair the device - no parts of the unit are user serviceable. Return the unit to an authorized OMRON retail outlet or distributor. •The device should be serviced once a year by an approved OMRON service centre. The device is very hot. The compressor is covered by a clo

  • Omron NE-C30-E, 28 9. Technical data Notes: •Do not use the device where it may be exposed to flammable gas. •This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Directive).  = Class ll = Warning: read the instruction manual carefully Important information regarding Electro Magnetic Compatibility (EMC) With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagneti

  • Omron NE-C30-E, Compressor Nebuliser Model NE-C30-E • Instruction Manual • Mode d’emploi • Gebrauchsanweisung • Manuale di istruzioni • Manual de instrucciones • Gebruiksaanwijzing • !"#$%$&'(%$ )$ *#')+",(,-.. ÌÓ IM-NE-C30-E-02-11/06 EN FR DE IT ES NL AR RU

  • Omron NE-C30-E, 9 1. Know your unit EN Accessories Material of attachment •Also applicable Section 10. Optional parts and accessories. F.Spare Air Filters x 5 G.AC Adapter G1.Power Connector G2.Power Cord H.Carrying Bag I.Instruction Manual J.Warranty Card Nebuliser Kit, Mouthpiece, Nosepiece, Adapter for Child Mask (SEBS): Polypropylene Adult Mask (PVC), Child Mask (PVC): PVC Adult Mask (SEBS), Child Mask (SEBS): SEBS Air Tube: PVC and Polypropylene Air Filter: Polyester Air Filter Cover: ABS       

  • Omron NE-C30-E, 18 4. Taking medication 4. When treatment is complete, turn the power off. Check that there is no condensation or moisture in the air tube and unplug the device from the power outlet. Warning: Condensation may occur in the air tube. Do not store the air tube while it contains condensation or moisture. This could result in infection via bacteria. If there is moisture or liquid remaining in the air tube, be sure to follow the procedure below to remove any moisture from within the air tube. 1)Make sure that the air tube is still connected to the air connector on the compressor. 2)Unplug the air tube from the nebuliser kit. 3)Turn on the compressor and pump air through the air

  • Omron NE-C30-E, 20 5. Cleaning and daily disinfecting 6. After cleaning and disinfecting the parts, rinse them thoroughly with clean water and allow the parts to air dry in a clean environment. 7. If the compressor is dirty, wipe it clean with a soft cloth moistened with water or mild detergent. Caution: The compressor is not waterproof. 8. If the outside of the air tube is dirty, wipe it clean with a soft cloth moistened with water or mild detergent. 9. Reassemble the nebuliser kit. Put the parts in a dry, sealed bag and place in the storage pocket of

  • Omron NE-C30-E, 12 3. Preparing the nebuliser for use 3.2Adding medication and assembling the parts 1. Remove the mouthpiece and cap from the nebuliser kit. 2. Remove the inhalation top from the medication tank. 1) Rotate the inhalation top anti-clockwise. 2) Lift the inhalation top out of the medication tank. 3. Remove the vaporiser head from the medication tank. 4. Add the correct amount of prescribed medication to the medication tank. Caution: The capacity of the medication tank is 2 to 7 ml. Note: Scales on the nebuliser kit are for refere

  • Omron NE-C30-E, 17 4. Taking medication EN 3. Inhale medication according to your doctor’s and/or health care adviser’s instructions. Using the mouthpiece Prepare your mouthpiece according to Section3.2.7. Insert the mouthpiece into your mouth and inhale the medication breathing normally. Exhale as normal through the mouthpiece. Using the nosepiece Prepare your nosepiece according to Section3.2.7. Inhale the medication through the nosepiece, as shown and exhale through the mouth. Using the adult mask (PVC) Attach the mask so that it covers your nose and mou

  • Omron NE-C30-E, 21 5. Cleaning and daily disinfecting EN Handling the Vaporiser Head The vaporiser head is an important part that is used to vaporise medication. Be sure to observe the following precautions when handling it. Caution: •Always wash the vaporiser head after each use. Failure to do so could cause blockages and a deterioration in your condition due to a failure to vaporise medication effectively. •Do not use a brush or pin etc., to clean the parts. This could damage the baffle and cause a deterioration in your condition due to a fail- ure to vaporise medication effectively. •When disinfectin

  • Omron NE-C30-E, 24 8.Troubleshooting Check the following if your unit should fail during operation. You can also refer to the pages of this manual for complete instructions. SymptomCauseRemedy Nothing happens when the power switch is pressed. (The power indicator does not light.) Is the AC adapter connected correctly to the an electrical outlet and the compressor? Check that the plug is inserted in an electrical outlet. Unplug then reinsert the plug if necessary. Is the optional rechargeable battery connected correctly? Make sure that the battery is correctly attached. Is the optional rechargeable battery charged sufficientl

  • Omron NE-C30-E, 13 3. Preparing the nebuliser for use EN 5. Reattach the vaporiser head to the medication tank. 6. Put the inhalation top back inside the medication tank. 1) Align the protrusion on the inhalation top with the indent on the medication tank, as shown. 2) Rotate the inhalation top clockwise and align with the medication tank until they click in place. 7. Attach the desired inhalation attachment, as described below. Attaching the mouthpiece Make sure you also attach the cap, when using the mouthpiece. 1) Attach the cap to the inhalat

  • Omron NE-C30-E, 30 10.Optional parts and accessories OMRON V.V.T. Nebuliser Kit Set Order No. 9956268-9 Air Tube (PVC, 207cm) Order No. 9956270-0 Mouthpiece Order No. 9956273-5 Air Tube (Silicon, 100cm) Order No. 9956269-7 Nosepiece Order No. 9956274-3 Child Mask (SEBS) Set Order No. 9956281-6 Adult Mask (SEBS) Order No. 9956312-0 Adult Mask (PVC) Order No. 9956275-1 Child Mask (PVC) Order No. 9956276-0 Air Filters (x 5) Order No. 9956636-6 Nebuliser Kit Mouthpiece Child Mask (SEBS) Adapter for ChildMask (SEBS)

  • 15 3. Preparing the nebuliser for use EN 8. Attach the air tube. 1) Attach the air tube to the air connector on the compressor. 2) Attach the other end of the air tube to the air tube connector on the medication tank. Notes: •Make sure that the air tube is securely attached to the compressor (main unit) and nebuliser kit, and does not come loose. Twist the ai

  • Omron NE-C30-E, 11 EN Operating instructions 3.Preparing the nebuliser for use Warning: Clean and disinfect the nebuliser kit, mouthpiece and optional nosepiece or masks before using them for the first time after purchase, if the device has not been used for a long period of time, or if more than one person uses the same device. For directions on cleaning and disinfecting the parts of the device refer to Section 5 in this instruction manual. Note: Make sure that the air filter is changed regularly. (See “7.

  • Omron NE-C30-E, 14 3. Preparing the nebuliser for use Attaching the child mask (PVC) Attach the mask to the inhalation top. 1) Attach the cap to the inhalation air inlet. 2) Attach the child mask to the inhalation top. Attaching the nosepiece Attach the cap when using the nosepiece. 1) Attach the cap to the inhalation air inlet. 2) Attach the nosepiece to the inhalation top.    

  • Omron NE-C30-E, 22 6.Maintenance and storage To keep your device in the best condition and protect the device from damage follow these directions: Caution: •Do not leave the unit unattended with infants or persons who cannot express their consent. •Do not subject the device or the parts to any strong shocks such as dropping the device on the floor. Notes: •Do not store the device in extreme hot or cold temperatures, high humidity or under direct sunlight. •Do not crease or fold the air tube. •Dispose of the device and any used accessories or optional parts according to applicable local regulations. •Never clean with benzene, th

  • Omron NE-C30-E, 31 10. Optional parts and accessories EN Filter Cover Order No.9956638-2 Instruction Manual Order No.9956633-1 Carrying Bag Order No.9956631-5 Battery Set Includes the rechargeable battery, battery charger. Order No.9986453-7 Rechargeable Battery Order No.9986457-0 Battery Charger Order No.9986461-8 AC Adapter Order No.9956628-5

  • Omron NE-C30-E, 2 Before using the unit Contents Before using the unit Introduction...................................................................................................3 Important safety instructions.......................................................................4 1.Know your unit........................................................................................8 2.Guide to using the Comp Air Elite.......................................................10 Operating instructions 3.Preparing the nebuliser for use...........................................................11 3.1Connecting the AC adapter.........................................................

  • Omron NE-C30-E, 29 9. Technical data EN Subsidiary OMRON HEALTHCARE UK LTD. Opal Drive Fox Milne, Milton Keynes MK15 0DG, United Kingdom Subsidiary OMRON Medizintechnik Handelsgesellschaft m.b.H. Windeckstraße 81a, D-68163 Mannheim, Germany www.omron-medizintechnik.de Subsidiary OMRON SANTÉ FRANCE SAS 14, rue de Lisbonne, F-93561 Rosny-sous-Bois Cedex, France Manufacturer OMRON HEALTHCARE CO., LTD. 24, Yamanouchi Yamanoshita-cho, Ukyo-ku, Kyoto, 615-0084 Japan EU-representative OMRON HEALTHCARE EUROPE BV Kruisweg 577, 2132 NA Hoofddorp, The Netherlands www.omron-healthcare.com

More Instructions:

DOWNLOAD

Related Products and Documents (Air Compressor):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Rotel RB-1090 Owner's manual rotel/rb-1090-OUL.pdf 11 Sep 2022 36 0.46 Mb
2 Zenith DSV-110 Operating manual zenith/dsv-110-118.pdf 21 Oct 2023 17 0.35 Mb
3 Kipor IG2000 Shop manual kipor/ig2000-CHO.pdf 08 Aug 2023 90
4 Renesas TM V.3.20A Operation & user’s manual renesas/tm-v-3-20a-5BT.pdf 18 Jan 2023 92 0.77 Mb
5 Aastra Clearspan 6757i Quick reference manual aastra/clearspan-6757i-Z2H.pdf 10 Dec 2022 2
6 DURKOPP ADLER 884 Instruction manual durkopp-adler/884-3V6.pdf 14 Jan 2024 72

Similar Resources:

  • Craftsman

    919.727360

    (60 pages)
    SAFETY GUIDELINESASSEMBLYOPERATIONMAINTENANCETROUBLESHOOTINGREPAIR PARTSIMPORTANT:Read the Safety Guidelinesand All Instructions CarefullyBefore OperatingSold by Sears Canada, Inc., Toronto, Ont. M5B 2B8Model No.919.727360Record in the spaces provided.(1) The Model Number can be found on themaintenance label on top of the motorshroud or on the bar code label …
  • GEA

    HA22P/125-4

    (26 pages)
    D GB F E I Ru109636-12.2014-DGbFEIRuengineering for a better world GEA Refrigeration TechnologiesGEA Bock Compressor HA22PAssembly instructionsHA22P/125-4 HAX22P/125-4 HA22P/160-4 HAX22P/160-4 HA22P/190-4 HAX22P/190-412345678910111213 …
  • Scheppach

    HC104DC

    (116 pages)
    HC104DCArt.Nr.5906133901AusgabeNr.5906133850Rev.Nr.05/11/2020DEKompressorOriginalbetriebsanleitung4GBCompressorTranslation of original instruction manual15FRCompresseurTraduction des instructions d’origine25ITCompressoreTraduzione delle istruzioni originali36SKKompresorPreklad originálu návodu na obsluhu47CZKompresor� …
  • Gude

    232/08/24

    (64 pages)
    -------------DE Originalbetriebsanleitung-------------EN Translation of the original instructions-------------FR Traduction du mode d’emploi d’origine-------------IT Traduzione del Manuale d’Uso originale-------------NL Vertaling van de originele gebruiksaanwijzing-------------CZ Překlad originálního návodu k provozu-------------SK Prekl …
  • L&W Compressors

    LW 200 B MC

    (140 pages)
    C H A P T E R O V E R V I E W Operating Instructions .............................................................................................................. ECC - Electronic Compressor Control (if equipped)......................................................... Spare Parts Lists .......................................................... …
  • Xstream

    AC5060B

    (38 pages)
    operation manualAC5060BAIR COMPRESSORCAUTION READ THIS MANUAL CAREFULLY before operating or servicing this air compressor, to familiarize yourself with the proper safety, operation, and standard operating procedures of this unit. FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS MANUAL COULD RESULT IN THE VOIDING OF YOUR WARRANTY, AND PERSONAL INJURY, AND/OR PROPE …

Comments, Questions and Opinions: