Text of Omega CTXL-TRH-W-W9 User Guide:

  • Omega CTXL-TRH-W-W9, 2.10 Open/Out of Range Input If the input to the recorder is open or out of range, the chart motor continues to run but the recorder handles the situation as follows: 1. Temperature/Humidity Model: When the sensor probe is disconnected, the pens go to the home position and the display shows “Prb Err”. When the probe is out of range, the display flashes. 2. Dual Thermocouple Model: When any of the two thermocouple inputs open up, the pens go to the home position, and the display shows “Prb Err”. When the input is out of range, the display

  • 7-1 Troubleshooting the Recorder 7 Table 7-1 contains a brief troubleshooting guide. Table 7-1. Troubleshooting Guide If this occurs Perform these steps ? Recorder appears not to function at all. Make sure POWER switch is pressed. Make sure the ac adapter is securely plugged into the wall and into the power jack on the recorder. If using fresh batteries, make sur

  • Omega CTXL-TRH-W-W9, 2-1 Setting Up the Recorder 2 2.1 Placing the Recorder on the Bench Top Figure 2-1 shows the removal of the decorative foot cover. 1. Place the recorder on its back (so it is face up). 2. Remove the clip-on foot cover by lifting up on the cover and releasing it from the stabilizing arm at the bottom of the recorder. This exposes the rubber feet and stabilizing arm. The rubber feet protect the bench top surface. CAUTION DO NOT ATTEMPT TO SET THE RECORDER UPRIGHT ON THE BENCH WHEN THE CLIP-ON FOOT COVER IS IN PLACE. T

  • Omega CTXL-TRH-W-W9, PC Interface Software 3 3-9 Figure 3-3. Settings Menu - Strip Chart Tab Screen In the Setting menu (Strip Chart Tab) • You can select the Screen Chart Speed from 1 hour up to 32 days. • You can select the Pen (trace) colors for the two channels on the screen. • You can select the scaling of the two channels, either auto, manual, or logarithmic. In order to perform manual scaling, uncheck the “Auto Scale” and enter your desired upper and lower values for temperature and relative humidity.

  • Omega CTXL-TRH-W-W9, 1-1 Introduction 1 This advanced Universal Circular Chart SUPERECORDER™ monitors and records data on a 1, 7, or 32 Days chart. The microprocessor based portable recorder provides many powerful and practical features as follows: • Four models are offered: Temperature/Relative Humidity –TRH [-17 to 49ºC (2 to 120ºF) & 2 to 98% RH] Dual Thermocouple Input –DTC [ J , K , or T type TC ] Dual Process Input –DPR [ (0-1, 0-5, 0-10) VDC, (0-20, 4-20) mA ] pH and RTD Input - pH • 203 mm (8") Chart paper for 1, 7, or 32 Day recording • C

  • Omega CTXL-TRH-W-W9, Wireless Temperature/Humidity Chart Recorder 8 8-5 8.2 Configuration The wireless transmitter and receiver have the following factory default configuration: Transmission time interval: 2 seconds Channel Frequency: 915 MHz (US & Canada) or 868 MHz (Europe) Unit ID: 00 (Both transmitter & receiver) The user does not have to do any configuration to the transmitter or the receiver if the factory configuration is satisfactory. However, if the user wants to change the configuration, then you need to run the configuration software that comes with the unit. Through the configuration software, the use

  • Omega CTXL-TRH-W-W9, Below is a typical data file saved after stopping the data logging process from the main menu. Please note that each pair of data is date & time stamped. Figure 3-13. Typical Data File Screen PC Interface Software 3 3-21

  • Omega CTXL-TRH-W-W9, I Index I A ac Adapter ............................................ 2-5 ac Power Failure .................................. 2-5 Alarms Deadband .............................. 4-3, 4 Enable/Disable ................ 2-10, 11 High ................................... 2-10, 11 Low .................................... 2-10, 11 Relay Outputs ........................ 2-11 Setting the Alarm ................... 2-10 B Batteries Compartment ....................... 1-3, 4 Installation/replacement ........ 2-4 Lif

  • Omega CTXL-TRH-W-W9, 2.4 Installing and Changing Chart Paper Make sure the Sensor probe is plugged into the Recorder when power is on. The Factory set up is for 7 Day Chart Speed & °F Chart Scale for CTXL-TRH. To install or change the same Chart paper: • Open the Recorder door & remove the magnetic hub that holds the paper. • Place the new Chart paper. • Rotate the paper, until the present time lines up with the Time reference arrow as shown in Fig 2.8. • Place the magnetic hub over the paper & close the recorder door. This can be done with or without power turned on. 2.4.1 Changing Chart Speed & Scale You can change t

  • Omega CTXL-TRH-W-W9, Troubleshooting the Recorder 7 7-2 Make sure the pens are fresh. Remove a pen and test it on a piece of chart p aper. Insert new pens if necessary. Bulbs don’t light. Bulbs are blown. Replace them with new bulbs. Make sure pen caps are removed (and secured in a safe location). Check that the pens are locked firmly in position in their holders. ? ? The pens do not appear to be leaving traces on the paper. ? The pens do not appear to be leaving traces on t

  • Omega CTXL-TRH-W-W9, ii CTXL High Performance Universal Portable Circular Chart Recorder TABLE OF FIGURES Figure Description Page 1-1 Front and Side Views of the Recorder - Temperature/Humidity Model ................................................ 1-2 1-2 Wiring Diagram, Dual Process Input Model, CTXL-DPR .... 1-4 1-3 Rear and Side Views ................................................................... 1-5 1-4 Front and Side Views of the Recor

  • NOTE: ROTATE CHART PAPER UNTIL PRESENT TIME LINES UP WITH ARROW. H 35 T 2 1 2 °C °F SCALE CLOCK SPEED SET LIGHT NO DISPLAY POWER CHART ALARM CONFIGYES MODE °F RH % 7D 1D M4098-F2-8.eps 7 PM 8 PM 9 PM 6 PM 5 P Figure 2-8. Changing Chart Paper and Setting the Time 2.5 Installing and Removing Pens The recorder already comes with the two pens installed. While the unit is

  • Omega CTXL-TRH-W-W9, 2.6 Setting Alarms and Time Clock The following flow chart shows how to set the alarms and the time clock in a Temperature/Humidity model recorder. Setting Up the Recorder 2 2-10 RH °F % 7D 1 °F 7D 1 °F 7D Press or keys to set high alarm Press key to enable/disable alarm 7D RH% 2 High Alarm - Channel 1 (Temperature) Real Time Mode Low Alarm - Channel 1 (Temperature) Press or keys to set low alarm Press key to enable/disable alarm High Alarm - Channel 2 (Humidity) Press or keys to set high alarm Press key to enable/disable alarm 2 RH% 7D Press ke

  • Omega CTXL-TRH-W-W9, °C °F SCALE CLOCK SPEED SET LIGHT NO DISPLAY POWER CHART ALARM CONFIG YES MODE °F 7D °C °F SCALE CLOCK SPEED SET LIGHT NO DISPLAY POWER CHART ALARM CONFIG YES MODE % % 7D °F 19 9V 1A SEE WIRING DIAGRAM ON FIG. 1-2 VOLTAGE CURRENT SENSOR/ PROCESS INPUT SENSOR/ PROCESS INPUT – + 20 23 24 25 26 15 16 18 10 1 17 17 H 35 T 2 CHAN 1 CHAN 2 INPUT TC REAR AND SIDE VIEWS Foot Cover Removed FRONT AND SIDE VIEW OF RECORDER - DUAL THERMOCOUPLE MODEL FRONT VIEW OF RECORDER - DUAL PROCESS INPUT MODEL M4098-F1-2.eps SEE PAGE 1-3

  • Omega CTXL-TRH-W-W9, In order to calibrate the input channels, you need to enter the password “calph”. Then you can calibrate each input channel. At every calibration point, you need to simulate either the pH millivolt signal equivalent or RTD resistance equivalent. pH Calibration: Simulate 4 pH = +177.5 mV , then Press ‘Set Low’ Simulate 7 pH = 0 mV , then press ‘Set High’ RTD Temp Calibration: Simulate 100 ohms RTD @ 20 ºC = 107.8 ohms , then press ‘Set Low’ Simulate 100 ohms RTD @ 80 ºC = 130.9 ohms , then press ‘Set High’ Then press ‘Save’ t

  • Omega CTXL-TRH-W-W9, • No co-location with other radio transmitters is allowed. By definition, co-location is when another radio device or it’s antenna is located within 20 cm of your wireless device and can transmit simultaneously. • Do not install two wireless CTXL transmitters within 20 cm of each other. • Do not operate your wireless transmitter closer than 20 cm to nearby persons. PRE-CAUTIONS - Battery Operation Your wireless transmitter is supplied with one AA size 3.6V Lithium battery (Omega p/n OM-NOMAD-BATT). This battery

  • Omega CTXL-TRH-W-W9, PC Interface Software 3 3-15 Figure 3-8. Settings Menu - Re-scale/Calibrate/Memory Tab Screen The above pictures show a dual process input recorder (4 to 20 mA) set for the following: • Process Value Range of 0 to 5000 corresponding to 0 to 100% of the recorder. • Engineering unit of GPM (Gallons per minute). • Process Y axis set for 0 to 5000 (You can select any other range within 0 to 5000). • Screen chart time base of 1 Hour.

  • 1.1 Parts of the Recorder M4098-F1-1.eps H 35 T 2 T E M P E R A T U R E H U M I D I T Y 1 11 5 11 2 21 22 4 9 2 8 13 10 7 6 9V 1A 12 14 13 °C °F SCALE CLOCK SPEED SET LIGHT NO DISPLAY POWER CHART ALARM CONFIG YES MODE °C °F SCALE CLOCK SPEED SET LIGHT NO DISPLAY POWER CHART ALARM CONFIG YES MODE PRIN

  • Omega CTXL-TRH-W-W9, OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a trademark of OMEGA ENGINEERING, INC. © Copyright 2018 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC. FOR WARRANTY RETURNS

  • Omega CTXL-TRH-W-W9, 2.9 Using the Sensor Clip An extra sensor clip is provided in the shipping box, so you can hang the sensor in a remote location. Two self-tapping screws are provided for mounting to wood, sheet rock or plastic surfaces. When mounting to wood or sheet rock surfaces, drill two 1 ⁄16" (1.5 mm) diameter holes. When mounting to plastic, drill two 5 ⁄64" (1.9 mm) diameter holes. Appropriate hardware must be selected when mounting to metal surfaces. Refer to Figure 2-17. M4098-F2-17.eps T E M P E R A T U R E H U M I D I

  • The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. omega.com [email protected] Servicing North America: U.S.A. Omega Engineering, Inc. Headquarters: Toll-Free: 1-800-826-6342 (USA & Canada only) Customer Service: 1-800-

  • Omega CTXL-TRH-W-W9, M4098/0218 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE MU Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies MU Wire: Thermocouple, RTD & Thermistor MU Calibrators & Ice Point References MU Recorders, Controllers & Process Monitors MU Infrared Pyrometers PRESSURE, STRAIN AND FORCE MU Transducers & Strain Gages MU Load Cells & Pressure Gages MU Displacement Transducers MU Instrumentation & Accessories FLOW/LEVEL MU Rotameters, Gas Mass

  • Index I M Maintenance ......................................... 5-1 Memory ......................................... 3-2, 4-2 MODE Key .................................. 1-5, 2-12 Mounting Holes (Key Holes) ... 1-3, 4, 2-3 O On/Off Power Switch ................. 1-5, 2-5 P PC Commands ................................. 3-1, 2 PC Communication .......

  • Omega CTXL-TRH-W-W9, e-mail: [email protected] For latest product manuals: www.omegamanual.info TM Shop online at omega.com User’s Guide RoHS 2 Compliant CTXL High Performance Universal Portable Circular Chart Superecorder TM

  • Omega CTXL-TRH-W-W9, 3-1 PC Interface Software 3 3 PC Communication You can communicate with the CTXL recorder thru RS232 port from a PC. There are a number of PC commands that allows the user to do the following functions: • Get the data (Like Temperature & Relative Humidity) in real time. This is the same data displayed on the LCD. • Download the stored chart data from the recorder to the PC. It will save the data into a data file. It can then be imported into the Excel spread sheet program for further review and analysis. • Re

Related Products and Documents (Voice Recorder):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sony KV-13FS100 - 13" Fd Trinitron Wega Tv Operating instructions manual sony/kv-13fs100-13-fd-trinitron-wega-tv-63C.pdf 18 Sep 2023 48 0.82 Mb
2 BALAY 3KFE3082 User manual manual balay/3kfe3082-9YR.pdf 12 Sep 2022 64 1.15 Mb
3 Summer 07260 Installation manual summer/07260-439.pdf 16 Aug 2022 1 0.23 Mb
4 Keys Fitness ROMAN CHAIR KPS-RC Features keys-fitness/roman-chair-kps-rc-753.pdf 30 May 2023 1
5 NEC XP21 - MultiSync - 21" CRT Display Operation & user’s manual nec/xp21-multisync-21-crt-display-J5P.pdf 04 Feb 2023 161
6 3Com WL-542 Operation & user’s manual 3com/wl-542-46T.pdf 15 Aug 2022 124 5.1 Mb

Similar Resources:

  • forus

    VRF4GB

    (4 pages)
    FORUS TELEPHONE VOICE RECORDER SKU: VRF4GB THANK YOU FOR PURCHASING THE FORUS TELEPHONE VOICE RECORDER Please read this manual before operating the VRF4GB and keep it handy. The Forus Telephone Voice Recorder is a feature-rich device adaptable to almost any situation. This recorder plugs into a wall jack or runs on batte …
  • Panasonic

    WJRT416 - 16CH DIGITAL RECORDER

    (80 pages)
    ERRORSEQUENCESETUPESCSEARCHCOPYSTOPPLAYPAUSERECREC STOPSETHDD12312345678910/0111213141516456ALARMMULTISCREENTIMERALARMRESETOPERATEREVFWDSKIPDigital Disk Recorder WJ-RT416Digital Disk RecorderInstallation GuideModel Nos. WJ-RT416WJ-RT416VWJ-RT416 is shown above.Before attempting to connect or operate this product, please read these instructions carefully and …
  • Olympus

    308-805

    (2 pages)
    U1-BZ8099-02-INST-E1 2005.4.15s You can switch the time indication between the 12-hour system and the 24-hour system by pressing theFOLDER/MENU button while you are setting the hour or minute.s You can change the order of the date indication by pressing the FOLDER/MENU button while you aresetting the year, month, or day.(Example: February 14, 2005)- 2 - - 4 …
  • Tascam

    DR-100

    (100 pages)
    DR-100)#Linear PCM RecorderD01292000BENGLISHFRANÇAISESPAÑOLDEUTSCHITALIANO日本語OWNER'S MANUALMODE D’EMPLOIMANUAL DEL USUARIOBEDIENUNGSANLEITUNGMANUALE DI ISTRUZIONI取扱説明書https://tascam.jp/jp/〒206-8530 東京都多摩市落合1-47TEAC AMERICA, INC.http://tascam.com/Phone: +1-323-726-03031834 Gage Road, Montebello, California 90640 US …
  • Olympus

    DS-2

    (120 pages)
    DIGITAL VOICERECORDERDS-2ONLINEINSTRUCTIONSThank you for purchasing an OlympusDigital Voice Recorder.Please read these instructions for informationabout using the product correctly and safely.Keep the instructions handy for future reference.To ensure successful recordings, werecommend that you test the record functionand volume before use.EN …
  • DigiTech

    XC-0383

    (6 pages)
    User Manual 4GB Digital Voice Recorder XC-0383 Contents Product Appearance………………………………………………..…2 Features…………………………………………………………....……3 Battery Indicator/Charging Times………… …

Comments, Questions and Opinions: