Manualios.com

NewMar SPM-200 Installation & Operation Manual

NewMar SPM-200 Manual Online:

4.7, 709 votes
NewMar SPM-200 User Manual
NewMar SPM-200 User Guide
NewMar SPM-200 Online Manual

Text of NewMar SPM-200 User Guide:

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 22 www.newmartelecom.com FIGURE 20: Networking Section of the Config Webpage Enter the appropriate IP address, Subnet Mask and Gateway address. CAUTION: once you click “Save”, the SPM will IMMEDIATELY switch to the IP address you just entered. It will NOT respond at 192.168.1.123 anymore. See 8.0 Appendix A: Troubleshooting #13 which describes the “Reset” button to function and use. If you are sure you have the correct settings, go ahead and click the “Save Changes” button. Now you will have to disconnect the SPM from the PC an

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 1 www.newmartelecom.com 1.0 Quick Reference Guide Firmware Update Access: Check www.newmartelecom.com/Site_Power_Monitor/Rev_C_Firmware_Update/Firmware.html for fi rmware updates. See page 19 for details. Link LED, Pg. 8 Ethernet/Cross-Over Cable /Data Logging Connection, Pg. 5 Static IP Address Reset Button, Pg. 28 & 30 Link Activity LED, Pg. 5 Earth Ground Stud, Pg.

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 19 www.newmartelecom.com 5.3.7 Admin Information FIGURE 16: Admin Information This is where you enter the information that will be printed at the bottom of every web page. Enter the information that is appropriate for your installation. Again, don’t forget to click the “Save” button. 5.3.8 Firmware Download & Upload FIGURE 17: Upload System Firmware From time to time Newmar may issue new fi rmware for the SPM-200. This will usually come as a “zip” fi le.

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] www.newmartelecom.com Section/Figure Topic Page 1.0 Quick Reference Guide.......................................................................................... 1 2.0 Overview................................................................................................................ 2 2.1 General Description.............................................

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 14 www.newmartelecom.com 5.1 Setting Low & High Alarm Trips The Alarms web page is where you configure the alarms for the unit. FIGURE 9: Alarms Page The user selects which data item each alarm covers. In the example above, Alarm #01 is set to trip if the (“Volts DC 1” input goes above 30.0V). We know it will trip if the value goes above the set point because “High Trip” has been selected. Note Alarm #02 is set to trip if the (same input goes b

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 20 www.newmartelecom.com Should you run into any trouble while updating, please DO NOT reset your SPM and contact us at: Phone: 800-354-3906 • Email: [email protected] This next section is fairly self-explanatory: 5.3.9 Test SNMP Trap & Email FIGURE 18: Test Buttons Clicking on these buttons allows you to test if you have set up your email and SNMP traps properly. 5.4 Setting Account Names & Passwords FIGURE 19: Account Settings

  • 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 23 www.newmartelecom.com 6.0 Specifications Inputs Power Source Voltage: 11 - 60 negative / positive ground* *CAUTION: If you intend to power -48 VDC AND monitor -48 VDC, input power must come from an isolated DC converter. If you

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 5 www.newmartelecom.com 3.2.2 DC Voltage Monitor Ports There are three ports total that monitor DC voltage. Two are rated for 0-40 VDC input, (terminals 15-16 and 17-18) and a third, (terminals 7-8) with inverse ground reference rated for 30-60 VDC input, intended primarily for neg. 48 volt telecom system use. Note all DC sense voltage ties to the SPM must share a comm

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 4 www.newmartelecom.com 3.0 Installation 3.1 Mechanical There are 3 methods of mounting: Wall, DIN-rail, and Rack. Regardless of method, please observe the following: free air flow (away from other equipments’ hot air exhaust so that the temperature sensor reads accurately). Indoor installation only! No exposure to rain, spray, or moisture. Plan your wire routing when considering location. Option A: Wall, Panel, or Inside Enclosure Mounting The SPM can be

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 15 www.newmartelecom.com FIGURE 10: Logging Page If for some reason you want to delete all the data that is in memory, click on the “Reset Logs”. Caution, there is no way to recover the data after the reset button is checked. The check boxes sensors (Sensors page) only control what data is being graphed, not what is being logged. The SPM-200 always logs the data from all the inputs. The data can be downloaded to a PC or a similar machine in Comma Separated Value (CSV) format

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 18 www.newmartelecom.com SNMP (“System Network Management Protocol”) is an Internet Standard way to monitor the elements in a network. The SPM-200 software includes what is called an SNMP “Agent”. SNMP agents send information to an “SNMP Management System”, which is running somewhere on the network. Management Systems can poll Agents, or an Agent can send information to the Manageme

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 9 www.newmartelecom.com 4.1.2 NIC Setup The following instructions describe the process in Windows XP. Earlier versions of Windows and Windows 7 follow a similar procedure. If you are using some other operating system please consult your users’ manual for instructions on how to set up the network interface card. 1. Click on the Start button. 2. Select the Control Panel. If the control panel is not an option you may need to choose Settings Control Panel. 3. Click on the Network Connection

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 17 www.newmartelecom.com The SPM-200 can be configured to send emails when alarms are raised. Emails can be sent to any combination of five addresses. Clicking a checkbox next to the right of an email address will send a notification to this receipent in the event of a power interruption. Refer back to FIGURE 9 – there we determined which alarms will cause emails to go to which of the five addresses. Here is where we set those addresses. The SPM-200 uses the standard SMTP em

  • 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 30 www.newmartelecom.com 12.0 Appendix B3: Typical System Wiring: Positive Ground, Common Returns

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 12 www.newmartelecom.com 5.0 SPM-200 Web Page Overview The Sensors Page shows the current value of all the inputs to the SPM. A Sensors Page from an SPM that has been running a while is shown on the following page, see FIGURE 8: FIGURE 7: SPM-200 Sensors (Unconfi gured Unit) This page allows the user to select data inputs and graph them over a chosen time period. The graph can show data over ranges in time from the last 10 minutes to the

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 16 www.newmartelecom.com The most important thing to do on this page is to set the name of this SPM-200, and more meaningful names for all of the inputs. As always, remember to select “Save” or your changes will not take effect. 5.3 Confi guration Page FIGURE 12: Top of Confi guration Page 5.3.1 Reset All to Default Values The fi rst entry allows you to

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 26 www.newmartelecom.com grayed out logging frequency/delete logs checkbox. 4. Select Save Changes to delete the log history. In a few seconds the graphs should go blank. Depending on the logging frequency, the graphing should begin in a few minutes. 8) I cannot get email from the unit • Below are some common solutions to email problems. 1. Make

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 6 www.newmartelecom.com Terminal# Board ID Function/Description Default Webpage ID 1 AC-LINE Measure AC utility power, 90 to 264 VAC. This input is isolated from all other inputs. Line Voltage 2 AC-NEU 3 INVIN Measures a fl oating AC sources like an inverter, 90 to 135 VAC. INV IN (GND) is common to all GND and RTN and -PWR IN. Inverter Voltage 4 INVIN(GND)* 5 Is 2 Measures DC

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 27 www.newmartelecom.com 13) How do you reset the SPM-200? • The IP Reset Button, located under the RJ45 connector, has two functions: 1) If you hold it down while you power up the unit, all of the user-configurable parameters are reset to the factory defaults. 2) If you hold it down for 20 seconds while the power is on, it resets the IP address to 192.168.1.123 and the subnet mask to 255.255.255.0, and clears out any user IDs and Passwords that you have set. This is useful if you have forgotten th

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 2 www.newmartelecom.com 2.0 Overview 2.1 General Description Your NEWMAR Site Power Monitor, model SPM-200, web-enables and integrates intelligence to any site’s AC and DC power system for 24/7 monitoring, alarm condition notification, and data logging of vital electrical functions. All sensor inputs are programmable, accessible, and managed via the Internet: T

  • 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 8 www.newmartelecom.com 4.0 SET-UP MONITORING & DATA LOGGING The SPM-200 Power Monitor does the following: • Displays the current values of the temperature, 3 DC voltages and 2 AC voltages, 1 DC current value and 3 contact

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] www.newmartelecom.com Section/Figure Topic Page 5.3.3 Configuring Email Settings..................................................................................... 16 Figure 13 Web Page: Email Settings....................................................................................... 16 5.3.4 Sending Text Messages..............................

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 25 www.newmartelecom.com 9.0 Appendix A: Troubleshooting 1) Nothing happens when I power up the SPM - Neither the Power Indicator nor the Status Indicator light up. • Check to make sure that DC power is connected. Pin 19 is ground and Pin 20 is +6 to +60 VDC. 2) The Power and Status Indicators light up, but I do not see any lights on the Ethernet Connector • Check to make sure that the SPM is connected either to an Ethernet switch o

  • NewMar SPM-200, 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] www.newmartelecom.com Site Power Monitor Installation/Operation Manual Model: SPM-200 M-SPM-200CONNRC As of 042018

  • 15272 Newsboy Circle Huntington Beach California 92649 Phone: 714-751-0488 Fax: 714-896-9679 E-Mail: [email protected] 29 www.newmartelecom.com 11.0 Appendix B2: Typical System Wiring: Negative Ground, Common Returns

More Instructions:

DOWNLOAD

Related Products and Documents (Microphone):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Listen Technologies LR-4200 Operation & user’s manual listentech/lr-4200-7S5.pdf 15 Dec 2022 21
2 Powermate PMC435003 Owner's manual powermate/pmc435003-16V.pdf 12 Mar 2024 12
3 Omega KEYCOUNTER KEY-3 Owner's manual omega/keycounter-key-3-NH2.pdf 23 Aug 2023 6
4 One for All URC-9800 Operation & user’s manual one-for-all/urc-9800-7QY.pdf 14 Jan 2023 35
5 Furuno ETR-30N Operator's manual furuno/etr-30n-5DL.pdf 03 Dec 2022 48 0.68 Mb
6 Oricom M5200 Series Operation & user’s manual oricom/m5200-series-3S4.pdf 23 Oct 2023 44

Similar Resources:

  • Shure

    WCM16 ISOMAX

    (2 pages)
    MODEL WCM16 ISOMAX* HEAD-WORN CONDENSER MICROPHONEGENERALThe Shure Model WCM16 head-worn electret condens-er microphone is intended for wireless use by performers,lecturers, and others who require the highest quality voicepickup with maximum mo bility. Its wide frequency re-sponse, low RF susceptibility and reliable operation at tem-perature and humidity ex …
  • Nady Systems

    PCM-100

    (2 pages)
    USER GUIDETo take full advantage of the superb features of the PCM-100/200, and toenjoy long and trouble-free use, please read this User’s Guide carefully.NADY PCM SERIESYour PCM-100/200 microphones was carefully packed at thefactory in a carrying case designed to protect the unit duringshipping. Please retain this container for subsequent transportand in …
  • Azden

    SGM-X

    (1 pages)
    28SEPTEMBER 2003videosystems.comSHOOTREVIEWBOTTOM LINECompany: AzdenFranklin Square, N.Y.; (516) 328-7500www.azdencorp.comProduct: SGM-X shotgun micAssets: Low noise; simple mini-jack I/O;windscreen for breezy conditions; shoemount for easy attachment to camera.Caveats: Use the windscreen only inwindy situations to avoid muffling thesound.Demographic: MiniDV …
  • Crown

    35246

    (11 pages)
    126676-1 7/00Crown International, IncP.O. Box 1000, Elkhart, Indiana 46515-1000(219) 294-8200 Fax (219) 294-8329www.crownaudio.com© 2000 Crown International, All rightsreserved PZM® , PCC®, SASS® andDIFFEROID®, are registered trademarks ofCrown International, Inc. Also exportedas Amcron® …
  • Avlex

    HS-38

    (2 pages)
    HS-38 Single Ear Headworn Microphone AVLEX CORPORATION www.avlex.com 6655 Troost Avenue Kansas City, MO 64131 Fax (816) 581-9104 Toll Free: 877-447-9216 Element Back electret condenser, 3.5mm diameter Polar Pattern Omni-directional Frequency Response 20Hz-20KHz Sensitivity -45±3dB 1V/Pa @ 1KHz Output Impedance 2000 Ohms±30% SPL max 140dB (155dB …
  • Shure

    BLX4R

    (64 pages)
    ©2013 Shure Incorporated27A21197 (Rev. 3)Printed in U.S.A.BLX4R Wireless ReceiverBLX4Rワイヤレス受信機BLX4R 무선 수신기Receiver Nirkabel BLX4BLX4R 无线接收机BLX4R 無線接收機 …

Comments, Questions and Opinions: