Manualios.com

Haier DW-25L92 Service Manual

Haier DW-25L92 Manual Online:

4.9, 1281 votes
Haier DW-25L92 User Manual
Haier DW-25L92 User Guide
Haier DW-25L92 Online Manual

Text of Haier DW-25L92 User Guide:

  • Haier DW-25L92, 3 / 33 Content 【Designation】 .......................................................................................................................................................... 4 【Safe Caution】......................................................................................................................................................... 5 【Product appearance】 ......................................................................................................................

  • Haier DW-25L92, 21 / 33 【Inspection and Maintenance Process for Typical Error】 Problem points Reason analysis Maintenance measures 1. the press can not start 1. The fuse is burned out. Change the fuse 2. Connecting parts of cabinet is damaged. Change socket connector. 3. The connecting line for electric cabinet is not in right position. Install correctly after inspection. 4. The temperature controller is in error. Adjust parameters. If the temperature controller is d

  • Haier DW-25L92, 33 / 33 Inspired living Haier Medical & Laboratory Products Co., Ltd. Room 403D, Brand Building, Haier Industrial Park, No.1 Haier Road Qingdao China Website: www.haiermedical.com

  • Haier DW-25L92, 30 / 33 0075010051 Compressor SC12CL(220-240V/50Hz) DW-40L 0274000190 Compressor SC12CLX.2(220-240V/50Hz/60Hz) 1 DW-40L 0074091173 Compressor SC12CLX.2(115/60Hz) 1 DW-40L 14 0070701909 DW-40L262 drier filter 1 15 0070401698 Compressor wire 1 16 0072040045 Wire connection box 1 17 0077050051 Screw 4 18 0070107165 Cover of cabin 1 19 0073150003 ROHS-sealing tube(black)490MM 4 20 0077050051 Screw 8 21 0067412381 built-in fitting parts PP 4 22 0060502027 C

  • 26 / 33 【Refrigerant perfusion Details】 Type DW-40L92 DW-40L188 DW-40L262 (220-240V/50 Hz /60Hz) DW-40L262 (115V/60Hz) DW-25L92 DW-25L300 R404a 150 210 220 200 R600a 52 90 [Note] refrigerant type and weight of the nameplate subject shall not misuse of refrigerant.

  • Haier DW-25L92, 15 / 33  The following is details for connection of computer board and ports;  Mark “1” in the above figure is connecting port for power line to connect power line; mark “2” in the above figure is sensor port to connect sensor line. 3. Installation steps for control board  Installation shall be according to 2-4 disassembly steps oppositively.

  • Haier DW-25L92, 17 / 33 8 Temperature adjustment principle and alignment This machine adopts microcomputer controlled temperature control system to control on-off of the press. In electrified condition, the screen may display current temperature. If you want to change the set temperature, for example, change from -30℃ to -35℃, please operate as following: Press both “∧” and “∨” for 3 seconds, the set temperature starts flickering. Press “∧” once, the temperature will decrease by 1℃ until it reaches -40℃, and then press back to

  • Haier DW-25L92, 2 / 33 Effective models This service manual is effective for following models Model name Product code Voltage(V) Frequency(Hz) Plug-type DW-25L92 BE02M9E0N 220-240 50 English Standard 英式三扁(flat) DW-40L92 BE02M8E0N 220-240 50 EU Standard 欧式两圆一孔 BE02M7E0N English Standard 英式三扁(flat) DW-40L188 BE02P1E1T 220-240 50 EU Standard 欧式两圆一孔 BE02P2E1T English Standard 英式三扁(flat) DW-25L300 BE02QDE0N 220-240 50 English Standard 英式三圆(round) DW-40L262 BE02Q4E1T 220-240 50 EU Standard

  • Haier DW-25L92, 12 / 33 【Components and Function Modules】 1. Temperature control It is controlled by microcomputer with digital display for temperature while the inner temperature can be adjusted from -10℃~-25/-40℃; there is parameter setting for super low temperature alarming and break down memory. 2. Safety system 2 error alarming (high/low temperature alarming, sensor error alarming 2 alarming methods (sound buzzing alarming, red light alarming) Starting up delay protection function 3. Refrigerating system Imported famous brand SECOP/DANFOSS compressor is adopted Environment protection free

  • Haier DW-25L92, Service Manual Deep Freezer-upright DW-25L92•DW-40L92•DW-40L188•DW-25L300•DW-40L262 Haier Medical & Laboratory Products Co., Ltd. DW-40L92 DW-40L188 DW-40L262 FILE No: HMRSM-02-002

  • Haier DW-25L92, 31 / 33 DW-25/40L92exploded view DW-25L92spare part list No. Code Name Qty 1 0060802007 Screw 15M6*16 3 2 00609380634 Seat of lower hinge 1 3 0064240002 Washer 65Mn 1 4 0067113077 Rotation shaft 15 2 5 0067744009 Washer of hinge 2 6 0270700332 Evaporator 1 7 0060809635 Foaming cabinet 1 8 0070104306 Fix board of compressor 1 9 0072130028 clips 2 10 0060611001 Power cable cn 1 0070400325D Euro power cable 1 0270400113 British 3-pinpower cable 1 11 0060700668

  • 14 / 33 .【Disassemble Steps】 1. Install the Handle ① .Align the handle to the screw hole on the door; ② .Use screw to fix the handle. 2. Disassemble steps for control board  Unscrew the following screws mark ed 1 and 2 in following figure, the control board can be fetched.  Attention: there are wires connecti

  • Haier DW-25L92, 32 / 33 14 0070401698 DW-40L188 compressor wire RVV3 ×0.75 1 15 0072040045 Wire connect box 1 16 0077050051 Screw 4 17 0070107165 Cover of cabin 1 18 0060801078 Screw 15B3.5*9.5 8 19 0067412381 Built-in fitting of condenser PP 4 20 00605020261 Condenser 1 21 0067266077 Inner pipe suit PVC 2 22 0060211012 Seal of power cable 1 23 0060106846 Support board 1 24 0060812716 Upper hinge

  • Haier DW-25L92, 18 / 33 【Control System Principle】 1 Working principle for press on and off When inner temperature reaches set temperature, induct the temperature by sensor and change into electrical signal which is sent to control chip of computer board. By pre-set procedure, the chip then sends out stop order to compressor to shut it down. When the inner temperature is returned 1℃ higher than set temperature, the chip sends out stop order via the same procedure to shut the compressor down. (If temperature return in the refrigerator is too fast, less than 5 minutes, then take it as 5 minut

  • Haier DW-25L92, 4 / 33 【Designation】 Regulations for type naming: Note: rated volume can be the gross volume or effective volume; the manufacturer can decide it by him according to the actual situation. The effective volume value must be marked on the nameplate whether effective volume or gross volume is marked in the product name. Examples: DW-40L262 means that the Deep temperature storage refrigerator with the temperature at characteristic temperature -40℃, horizontal and rated effective volume 262L. DW XX X XXX X A Design No. is ex

Related Products and Documents (Freezer):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Kidde 0913 Datasheet kidde/0913-139.pdf 22 Nov 2022 2
2 OPTI-UPS EL3000-AL Specification sheet opti-ups/el3000-al-JN6.pdf 26 Sep 2022 1
3 Grindmaster B-6 Brochure & specs grindmaster/b-6-4U9.pdf 24 Mar 2024 6 2.01 Mb
4 Zanussi ZA52 Instructions for installation and use manual zanussi/za52-53N.pdf 20 Nov 2022 11 2.73 Mb
5 Verona CTG212FD Operating instructions manual verona/ctg212fd-E8S.pdf 06 May 2023 20 0.83 Mb
6 Philips MCM108D/98 Operation & user’s manual philips/mcm108d-98-1YN.pdf 12 Feb 2024 19 0.99 Mb

Similar Resources:

  • Indesit

    GSF 4200 W

    (56 pages)
    CongelatoreInstallazione e usoFreezerInstallation and useCongélateurInstallation et emploiEinbautiefkühlgeräteInstallation und GebrauchVriekastPlaatsing en gebruikCongeladorInstalación y usoCongeladorInstalação e usoGSF 4200 W …
  • Whirlpool

    UPRIGHT FREEZER

    (28 pages)
    UPRIGHT FREEZERUse & Care GuideFor questions about features, operation/performance parts, accessories or service, call: 1-800-253-1301.In Canada, for assistance, installation or service call: 1-800-807-6777or visit our website at...www.whirlpool.com or www.whirlpool.caCONGÉLATEUR VERTICAL Guide d’utilisation et d’entretienAu Canada, pour assistance, …
  • Hussmann

    IMPACT Elite E1

    (6 pages)
    B(OptionalLights)EDCT'Stat BulbLocationAP/N 0453530_BNote: Changed items have been underlined.E1Technical Data Sheet P/N 0453530_BNSF®CertifiedJuly 2007Item Part # Description Wiring Item #FAN ASSEMBLIES AND THERMOSTATSA. 4W Standard Fan Assembly (1)0392457 Fan Motor, Evaporator(MO.4410101)0409513 Fan Blade, (FB.0409513)embossing toward motor4W Energ …
  • Vinotemp

    WM-2500SSRWC

    (29 pages)
    wwwwww..wwiinneemmaattee..ccoomm Rack Split Cooling System Installation, Operation & Care Manual WM-2500SSRWC WM-4500SSRWC WM-6500SSRWC wwwwww..vviinnootteemmpp..ccoomm RReeaadd aanndd ssaavvee tthheessee iinnssttrruuccttiioonnss …
  • Frigidaire

    242321500

    (2 pages)
    SERVICE DATA SHEET242321500ICE & WATER - AUTOMATIC DEFROSTBOTTOM FREEZER - R134a CAUTIONAll electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner.PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37 …
  • Electrolux

    304 AISI

    (5 pages)
    Electrolux Benefit CabinetsDigital freezers - 1300 ltThe range consists of 4 fan assisted models of 1300 litres refrigeration cabinets that offer excellent standards in terms of performance and efficiency. These models come in freezer version with a choice of materials (304 AISI, 430 AISI or white painted steel) and are available with full doors.727129• In …

Comments, Questions and Opinions: