  • Cisco MDS 9396T, Figure 12: SFP+ Transceiver with Mylar Tab Latch Figure 13: SFP+ Transceiver with Bale-Clasp Latch Installing an SFP+ Transceiver To install an SFP+ transceiver, follow these steps: Step 1 Attach an ESD-preventive wrist strap and follow its instructions for use. Step 2 Remove the dust plug from the switch port cage. Step 3 Insert the transceiver into the port: • If the transceiver has a mylar tab latch, orient the transceiver with the tab on the bottom, and then gently insert the transceiver into the po

  • Cisco MDS 9396T, Figure 8: Handling the Chassis Unpacking and Inspecting the Switch When handling switch components, wear an ESD strap and handle modules by the carrier edges only. An ESD socket is provided on the chassis. For the ESD socket to be effective, the chassis must be grounded through the power cable, the chassis ground, or the metal-to-metal contact with a grounded rack. Caution Keep the shipping container in case the chassis requires shipping in the future. Tip Cisco MDS 9396T Multilayer Fabric Switch Hardware Installation Guide 24 Installing the Cisco MDS 9396T Switch Unpacking and Inspecting the Switch

  • Cisco MDS 9396T, • The distance between the outside face of the front mounting rail and the outside face of the back mounting rail should be 23.5 to 34.0 in. (59.7 to 86.4 cm) to allow for installation with the Cisco rack mounting kit. • There should be a minimum of 2.5 in. (6.4 cm) of clear space between the side edge of the chassis and the side wall of the cabinet. No sizable flow obstructions should be immediately in the way of the chassis air intake or exhaust vents. • The distance between the rear of the chassis

  • Cisco MDS 9396T, Power Supply Requirements Specifications The following table provides a sample calculation of power for the Cisco MDS 9396T switch AC power supply. Table 3: Power Dissipation for AC Power Supply Power at 220V/50HZ (Watts) Power at 110V/60HZ (Watts) Fan Trays LEMOptics Number Optics Speed VoltageTemperatureTraffic Rate PSUPower Mode 330338204832G-SWNominal25°C50%2Typical 555570396 595610239632G-SWNominal 25°C100%2Max 61862732G-LW 65567332G-SW 756 79832G-LW55°C 806858Nominal + 5% To prevent a loss of input power, ensure that the total maximum load on each circuit supplying the power supply is within the current ratings of the wiring and break

  • Cisco MDS 9396T, DateTimeVerified ByPlanning ActivityTask No. Environmental evaluation: • Ambient temperature • Humidity • Altitude • Atmospheric contamination • Air flow 2 Power Evaluation: • Input power type • Power receptacles 1 • Receptacle proximity to the equipment • Dedicated circuit for power supply • Dedicated (separate) circuits for redundant power supplies • UPS 2 for power failures 3 Grounding evaluation: • Circuit breaker size • CO ground (AC- powered systems) 4 Cable and interface equipment evaluation: • Cable type • Connector type • Cable

  • Before you begin • A fan slot must be open and ready for the new fan module to be installed. • You must have a new fan module on hand and ready to install within one minute of removing the original fan module if the switch is operating. • The new fan module must have the same airflow direction as the other fan and power supply modules installed in the switch. All of

  • Cisco MDS 9396T, Console DeviceRJ-45 to DB-25 Terminal Adapter RJ-45 to RJ-45 Rollover CableConsole Port GND754GND GND745GND TxD236RxD DTR2027DSR RTS418CTS Connecting the Console Port to a Computer Using the DB-9 Adapter You can use the RJ-45 to RJ-45 rollover cable and RJ-45 to DB-9 female DTE adapter (labeled “Terminal”) to connect the console port to a computer running terminal emulation software. The following table lists the pinouts for the console port, the RJ-45 to RJ-45 rollover cable, and the RJ-45 to DB-

  • StateStatusColorFunctionLocationIndicator Either of the following conditions exists: • The system is not receiving sufficient power from the PSUs. • The operating system is not running. OffOffChassis power/Health Front panel of chassis Power LED Both PSUs are installed and operating Solid OnGreen Either of the following conditions exists: • A PSU has failed. • A PSU has been removed. Solid

  • StateStatusColorFunctionLocationIndicator All diagnostics have passed, Cisco NX-OS is running and the system is operational. Solid OnGreen System Status Front panel of chassis Status LED Any of the following conditions exists: • The system is running bootup diagnostics. • The system is booting. • A minor temperature threshold is currently exceeded. Solid OnOrange Mismatched airflow directio

  • Cisco MDS 9396T, THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS. THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOF

  • Cisco MDS 9396T, APPENDIX A Cable and Port Specifications This appendix includes the cables and connectors used with the Cisco MDS 9396T Multilayer Fabric Switch. We strongly recommend that power cable runs and other potential noise sources be located as far away as practical from network cabling that terminates on Cisco equipment. In situations where long parallel cable runs exist but cannot be separated by at least 3.3 ft. (1 m), we recommend that you shield these potential noise sources. To avoid interference, the source should be shielded by housing

  • Cisco MDS 9396T, Figure 4: Cisco MDS 9396T Fan Module The Cisco MDS 9396T switch has internal temperature sensors that can shut down the system if the temperature at different points within the chassis exceeds certain safety thresholds. Temperature control within the chassis is dependant on airflow created by the fan modules; therefore, in the event a fan module is removed from the chassis, the Cisco MDS 9396T switch will shut down after five minutes to prevent potentially undetectable overheating. However, the switch will shut down sooner if a higher-level temperature threshold is exceeded. For normal operation, the Cisco MDS 9396T switch requires two fans. Fan module status is indicated on a fron

  • Cisco MDS 9396T, CHAPTER 5 Connecting the Cisco MDS 9396T Switch The Cisco MDS 9396T switch provides the following types of ports: • Console port—An RS-232 port that you can use to create a local management connection. • MGMT 10/100/1000 Ethernet ports—Two Ethernet ports that you can use to access and manage the switch by IP address, such as through the CLI or Fabric Manager. One of the Ethernet ports can also be used to export analytic data. • Fibre Channel ports—Fibre Channel ports that you can use to connect to the SAN, or for in-band management. • USB port—USB port that you can use for configuration file backups, and capturing logs to file. This chapter describes how t

  • Cisco MDS 9396T, 3. Insert a dust plug into the connector on the cable. 4. Insert a dust plug into the cable end of the transceiver. If the transceiver does not remove easily in the next step, push the transceiver all the way back in and then ensure that the latch is in the correct position before continuing. Tip Step 3 Remove the transceiver from the port: • If the transceiver has a mylar tab latch, gently pull the tab straight out (do not twist), and then pull the transceiver out of the port. • If the transceiver has a bale-clasp latch, open the clasp by pressing it downwards, and then pull the transceiver o

  • Cisco MDS 9396T, CHAPTER 2 Product Overview The Cisco MDS 9396T 32 Gbps 96 Port two rack unit Fibre Channel switch provides high speed Fibre Channel connectivity in the SAN. This switch offers analytics and telemetry capability built into its Application-Specific Integrated Circuit (ASIC) platform. The Non-Volatile Memory express (NVMe)-ready switch allows seamless transition to Fibre Channel Non-Volatile Memory Express (FC-NVMe) workloads whenever available without any hardware upgrade in the SAN. This high density, highly reliable and scalable, enterprise class semi-modular switch is ideal for medium t

  • Cisco MDS 9396T, Installing a Cable into an SFP+ Transceiver 44 Removing a Cable from an SFP Transceiver 45 Maintaining SFP Transceivers and Fiber-Optic Cables 45 Powering Up the Switch 46 Technical Specifications 49 CHAPTER 6 Switch Specifications 49 Power Specifications 50 General Power Supply Specifications 50 Power Supply Requirements Specifications 51 Connection Guidelines for AC-Powered Systems 51 Cable and Port Specifications 53 APPENDIX A Cables and Adapters 53 Console Port 54 Console Port Pinouts 54 Con

  • Cisco MDS 9396T, • If the modules have burgundy coloring, position the port end of the chassis in the cold aisle. • If the modules have blue coloring, position the fan trays and power supply end of the chassis in the cold aisle. • Make sure that two front-mount brackets are securely fastened to the sides of the chassis at the port end. • Make sure that you have two customer-supplied rack-mount screws (M6 x 10 mm or appropriate screw for the vertical mounting rails on the rack). Step 1 Slide the power sup

More Instructions:

DOWNLOAD
DOWNLOAD

Related Products and Documents (Switch):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Jenn-Air ICE MAKER Use & care manual jenn-air/ice-maker-ZD5.pdf 11 Dec 2023 44
2 Panasonic HDC-SD600 Operating instructions manual panasonic/hdc-sd600-8I1.pdf 19 Jun 2022 140 6.09 Mb
3 Sony XS-L1036 Installation/connections sony/xs-l1036-46R.pdf 09 Sep 2022 2 0.14 Mb
4 Asus RS720Q-E6 RS12 Operation & user’s manual asus/rs720q-e6-rs12-AM5.pdf 24 Oct 2023 166 12.7 Mb
5 LG IPS225T-BN Owner's manual lg/ips225t-bn-2V6.pdf 21 Apr 2023 26
6 Polaris Sportsman 500 X2 Owner's manual polaris/sportsman-500-x2-73R.pdf 14 Jan 2024 136

Similar Resources:

  • Intellinet

    561587

    (16 pages)
    Scan to register yourproduct warrantyImportant: Read before use. • Importante: Leer antes de usar.For additional benets:or go to: register.intellinet-network.com/r/56158748-Port Gigabit Ethernet PoE+ Layer2+ Managed Switch with Four 10G SFP+ Uplinks InstructionsModel 561587 (IPS-52GM04-10G-400W) …
  • Painless Performance

    50340

    (8 pages)
    Off-Road Switch Panel Installation Instructions 50340: 6 Switch Extreme Off-Road Switch Panel w/ Push Button Start Painless Performance Products recommends you, the installer, read this installation manual from front to back before installing this harness. …
  • HP

    ProCurve 3500yl-48G-PWR

    (15 pages)
    ProCurve Switch 3500yl-48G-PWRThe ProCurve 3500yl-48G-PWR is an advanced Layer 3 stackable in 1U height. Ithas 44 10/100/1000Base-T ports, 4 dual-personality ports, integrated PoE on all10/100/1000Base-T interfaces, and an expansion slot for an optional 4-port10-GbE module. The foundation for this switch is a purpose-built, programmableProVision ASIC that al …
  • CAMDEN

    CM-9800

    (5 pages)
    Page 1 of 5CM-9800 Touch Button SwitchINSTALLATION INSTRUCTIONSDoor Activation Devices SL NO Component Name Quantity1 Wall plug 6mm 32 Wall xing screw 4 x 30mm 33 3 x 6 Security Screw 14 IN4007 diode 15 470nf Capacitor 16 10K Res 1/2w 17 Security screw driver 18 6-32 x 1" Machine screw 29 Mounting Template 11. GENERAL DESCRIPTIONCM-9800 is a request- …
  • D-Link

    Air DWL-120

    (2 pages)
    DW L - 1 2 0C re ate a Netwo rk and ShareI n t e rnet Access without Wi re sUSB Wireless A d a p t e rThe DWL-120 is a high-performance Wireless USB Netwo r kA d a p t e r. It Delivers 11Mbps (Megabits per second), making theDWL-120 the fastest Wireless Network Adapter on the marke tt o d a y. The USB interface makes the DWL-120 easy to install a …
  • JVC

    KM-H2500E

    (56 pages)
    For Customer Use:Enter the Model and Serial number of your unit.Retain this information for future reference.Model:Serial:MULTI FORMAT DIGITAL PRODUCTION SWITCHERKM-H2500E/UKM-H3000E/UINSTRUCTIONSThank you for purchasing this JVC product. Before operating thisdevice, please read the instructions carefully to ensure the bestpossible performance.This illustrat …

Comments, Questions and Opinions: