Manualios.com

Fujitsu UTB-YDB Installation Instruction

Fujitsu UTB-YDB Manual Online:

4.65, 1778 votes
Fujitsu UTB-YDB User Manual
Fujitsu UTB-YDB User Guide
Fujitsu UTB-YDB Online Manual

Text of Fujitsu UTB-YDB User Guide:

  • Fujitsu UTB-YDB, En-1 English SAFETY PRECAUTIONS ● Before using the appliance, read these “SAFETY PRECAUTIONS” thoroughly and operate in the correct way. ● The instructions in this section all relate to safety; be sure to maintain safe operating conditions. SAFETY PRECAUTIONS ............................................... 1 STANDARD PARTS ........................................................ 2 FLOW OF INSTALLATION .............................................. 2 INSTALLATION ............................................................... 3 SETTING......................................................................... 5 • EXPLANATION OF TERMS ...............................

  • Fujitsu UTB-YDB, En-2 STANDARD PARTS The following installation parts are supplied. Use them as required. Q’ty 1 4 Application Use for air conditioner operation Use this for writing the names of the indoor units that have been regis- tered. Name and Shape Group remote controller Label Q’ty 2 1 Application For installing the remote controller For remote controller and remote controller cord binding Name and Shape Tapping screw (M4 × 16 mm) Binder * Use of this product requires a special convertor and connection cable. These are provided as service parts, so please contact authorized service personnel. FLOW OF INSTALLATION The following is the flow of the installation of Group remote controller. • INSTA

  • Fujitsu UTB-YDB, En-3 INSTALLATION 1. SPECIFICATION 83.5 (3-9/32) 15.3 (5/8) 63.5 (2-1/2) Hole 45.3 (1-25/32) 4.5 (3/16) 8 (11/32) 12.5 (1/2) Hole × 2 Hole × 3 4.5 (3/16) 4.5 (3/16) 6 (1/4) 30 (1-3/16) 33.5 (1-5/16) 23 (29/32) 120 (4-3/4) 120 (4-3/4) 17 (11/16) When connecting the Group remote controller and Convertor, use the following wiring. Use Remote controller cord Size 0.33 mm 2 (AWG22) Wire type Shield cable Remarks Polar 3-core * We recommend that you purchase our service parts for the remote controller cord. Contact service personnel to purchase this. Unit: mm (in.) 2. WIRING • Total remote controller cord length: MAX. 100 m (328 ft.) (1) When c

  • Fujitsu UTB-YDB, En-4 Open the operation panel on the front of the remote controller, remove the two screws indicated in the right figure and then, re- move the front case of the remote controller. NOTES When installing the remote controller, remove the connector from the front case. The wires may break if the connector is not removed and the front case hangs down. When installing the front case, connect the connector to the front case. ● When remote controller cord exposed 1) Make two horizontal or two vertical holes in the mounting surface (wall, etc.) to install the remote controller. (Fig. 2) 2) Use a too

  • Fujitsu UTB-YDB, En-5 SETTING EXPLANATION OF TERMS Indoor unit System Refrigerant system Refrigerant pipe Convertor Outdoor unit Group remote controller Transmission line Controller line Wireless remote controller Wired remote controller Remote controller group Controller related items ● System: This is all of the indoor units, outdoor units and controller units connected by the same transmission line. ● Refrigerant system: [Not for J-series*] This is a system composed of indoor and outdoor units connected by the same refrigerant pipe. ● Remote Controller group: [N

  • En-6 ● With cover closed Indoor Unit Name Labels ● With cover open Setting Display Day Display Timer and Clock Display Timer Mode Display Timer Mode (DELETE) Button DAY Button Set Time Button PROGRAM (CLOCK ADJUST) Button ENTER Button Transmission Display Operation Lock Display ON/OFF Display Fan Speed Display Temperature Display Operation Mode Display Start/Stop Button Select Button F

  • En-7 TURN ON THE POWER Turn on the power Once the installation and wiring has been completed, use the following procedure to turn on the power. 1. Turn on the power for all connected indoor units. 2. Turn on the power for all connected outdoor units. 3. Turn on the power for all connected convertor of group remote controllers. For J-series 1. Turn on the power f

  • En-8 REMOTE CONTROLLER SETTINGS Remote Controller Settings Initial Screen Remote Controller Settings ● To select the setting DAY Press the DAY button to select the item to be set. Settings : Setting the Group remote controller address → Page 8 , : Forbidden → Page 9 : Time Display Settings → Page 9 : Timer Operation Settings → Page 9 : Temperature Range Settings → Page 10 : Temperat

  • Fujitsu UTB-YDB, En-9 , Forbidden To move to the following settings ● Forbidden Press the DAY button to move to “ Time Display Settings. ” ● Forbidden Press the DAY button to move to “ Setting the Group remote controller address. ” Time Display Settings (This switches the time display.) To switch the time display 1 Decrement Increment Press the Set Time buttons to set the time display. Check that it is . Time Display Setting or : 24 Hour Clock Display : 12 Hour Clock Display 1 : 12 Hour Clock Display 2 2 Press the ENTER button. Check that and flash

  • Fujitsu UTB-YDB, En-10 Temperature Range Settings (This changes the temperature range.) To set the temperature range Press the Set Time buttons to set the temperature range. Check that it is . Temperature range setting 2 Press the ENTER button. Check that and flash for two seconds. 3 Press the DAY button to move to “ Temperature Display Settings.” 1 Decrement Increment ● The temperature range set for heating operation is different. DAY Temperature Display Settings (This switches the display between Celsius and Fahrenheit.) To switch the temperature display Press the Set Time buttons to set the temperature display. Check that it is . Temperature di

  • Fujitsu UTB-YDB, En-11 INDOOR UNIT REGISTRATION ● A maximum of 8 remote controller groups can be registered for a Group remote controller. ● Remote controller groups in 2 different refrigerant systems that are connected to a single convertor can be registered. ● The remote controller groups registered can be monitored and controlled. ● When registering indoor units to each of the buttons, consult the customer. Indoor unit registration screen 1 2 3 4 Refrigerant circuit address (Not shown with J-series) Registration position Indoor unit address Remote controller address (Not shown with J-series) Indoor Unit Registration Methods ● Manual registration ● Automat

  • Fujitsu UTB-YDB, En-12 4 When a remote controller group made up of multiple indoor units is registered, the remote controller address and the indoor unit address are selected. Decrement Increment ● Remote controller address selection Indoor unit address ex.: Refrigerant circuit address “ ”, remote control- ler address “ ” * The refrigerant circuit address is the same as the address for the indoor unit set first (remote controller address “ ”) and cannot be changed. 1. Press the PROGRAM (CLOCK ADJUST) button to select the remote controller address of the indoor unit being registered.

  • Fujitsu UTB-YDB, En-13 Moving to “ REMOTE CONTROLLER SETTINGS” To set the remote controller Press the Set Temperature button seven times or press the Set Temperature button once to move to remote controller settings. Completing All of the Settings To complete Settings ● When the remote controller settings and indoor unit settings are complete Hold down again the Set Time buttons and simultaneously for two seconds or more to complete Settings. FINAL STEP To apply the label Write the name of the indoor unit or the room where it is installed o

  • Fujitsu UTB-YDB, En-14 00 No error No error No error 01 –– – 02 Model information abnormal Model information abnormal – 03 Microcomputer communication error Microcomputer communication error Microcomputer communication error 04 Power supply frequency abnormal Power supply frequency abnormal – 05 –– Parallel communication error 06 EEPROM access error EEPROM access error EEPROM access error 07 EEPROM deletion error EEPROM deletion error – 08 –– – 09 Compressor 1 error Room temperature thermistor error – 0A Compressor 2 error Heat exchanger thermistor (middle) error – 0b Compressor 3 error Heat exchanger thermistor (inlet) error – 0C – Heat exchanger

Related Products and Documents (Remote Control):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 GE 23-11-2129N-002 Owner's manual and installation instructions ge/23-11-2129n-002-8NH.pdf 05 Feb 2024 16 0.99 Mb
2 Sony PFV-L10 Operation manual sony/pfv-l10-YA6.pdf 20 Jul 2022 20 0.24 Mb
3 Kawai SX-240 Owner's manual kawai/sx-240-9A1.pdf 24 Mar 2023 22
4 ADC Advantage 6021N Directions for use manual adc/advantage-6021n-9ND.pdf 04 Sep 2023 18
5 Digital Monitoring Products 9000 series Installation manual digital-monitoring-products/9000-series-UQ5.pdf 21 Mar 2024 8
6 Rockford Fosgate Punch 100 Installation & operation manual rockford-fosgate/punch-100-B51.pdf 18 Jul 2023 40 2.59 Mb

Similar Resources:

  • ANATEL

    OKA-876T

    (2 pages)
    User's manual (provisionally) / OKA-876T, OKA-877T ◎ REMOTE TRANSMITTER You can lock and unlock your vehicle with the remote transmitter. LOCK When you push the button, all the doors will lock. You cannot lock any of the doors with the remote transmitter if any door is open or the key is the ignition switch. UNLOCK When you push the button, all the do …
  • Yamaha

    Outboards 703

    (20 pages)
    Marine Outboards 703 REMOTE CONTROL BOX OPERATION MANUAL MODE D'EMPLOI DE BOITIER DE COMMANDE A DISTANCE "T YAMAHA MOTOR CO., LTD. 703-28199-33 • http://motorka.org …
  • Mitsubishi Electric

    MHK2

    (17 pages)
    RedLINK™ Wireless Remote Controller Kit Installation Manual MHK2:MRCH2 Controller, MIFH2 Receiver, and MRC2 CableDISCONNECT POWER BEFORE BEGINNING INSTALLATION. Can cause electrical shock or equipment damage.Must be installed by a trained, experienced technician. Read these instructions carefully. Failure to follow these instructions can damage the produ …
  • Fusion

    MS-NRX300

    (16 pages)
    ®FUSION® MS-NRX300 Installation Instructions ......................................................................................................................... 2Instructions d'installation du FUSION® MS-NRX300 ................................................................................................................. 4FUSION® MS-NRX300 I …
  • Kopp

    8071.0202.3

    (8 pages)
    Vor Inbetriebnahme die Bedienungsanleitung sorgfältig durchlesen!Eine zuverlässige Funktionsweise der Funkzeitschaltuhr ist nurgegeben, wenn diese Funkzeitschaltuhr in Einklang mit denAnweisungen verwendet wird.EinleitungMit Free-control schalten Sie einfach, komfortabel und bequem IhreElektrogeräte. Ein funktionsfähiges Funksystem besteht in derMinimala …
  • Maytech Electronic

    MTSKR1712

    (5 pages)
    Maytech MTSKR1712 Remote control Users Manual V2.1 Maytech Electronics Co.,Ltd第1页 共5页 User Manual of Electric Skateboard Remote Controller MTSKR1712 V2.1 19/June/2017  …

Comments, Questions and Opinions: