GE MultiNet Instruction Manual

GE MultiNet Manual Online:

4.9, 2135 votes
GE MultiNet User Manual
GE MultiNet User Guide
GE MultiNet Online Manual

Text of GE MultiNet User Guide:

  • GE MultiNet, Copyright © 2017 GE Multilin Inc. All rights reserved. The contents of this manual are the property of GE Multilin Inc. This documentation is furnished on license and may not be reproduced in whole or in part without the permission of GE Multilin. The content of this manual is for informational use only and is subject to change without notice. Part number: 1601-0117-A4 (July 2017) For product support, contact the information and call center as follows: GE Grid Solutions 650 Markland Street Markham, Ontario Canada L6C 0M1 Worldwide telephone: +1 905 927 7070 Europe/Middle East/Africa telephone:

  • GE MultiNet, TOC TABLE OF CONTENTS MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL TOC–I Table of Contents FEATURES ..............................................................................................................................................1 DESCRIPTION .......................................................................................................................................2 RS485 SERIAL PORT .............................................................................................

  • MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL 1 MultiNet Serial to Ethernet Converter Instruction Manual GE Grid Solutions Instruction Manual 1. Features • Converts Modbus ® RTU over RS485 into Modbus ® TCP/IP over Ethernet. • Supports both 10BaseT Ethernet and 10BaseF fiber connections. • Connect up to 32 RS485 serial devices to an Ethernet

  • GE MultiNet, 2 MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL INSTRUCTION MANUAL 2. Description The MultiNet Serial-to-Ethernet converter is a communications module that provides GE Multilin serial Modbus IEDs with Modbus TCP/IP communications over Ethernet. MultiNet has the capability to connect up to 32 serial Modbus devices, eliminating complex wiring and additional communications converters, as well as providing a streamlined and economical Ethernet hub. Unlike most communications converters designed for commercial use, MultiNet is environmentally hardened to withstand severe utility and industrial conditions. MultiNet can be used to co

  • GE MultiNet, INSTRUCTION MANUAL MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL 3 3. RS485 Serial Port RS485 data transmission and reception is accomplished over a single twisted pair with transmit and receive data alternating over the same two wires. Using this port, continuous monitoring and control to a PLC, protection relay or any serial Modbus IED is possible. Connect the “+”, “–“ and common terminal of MultiNet to the “+”, “–“ and common terminals of all the IEDs. Correct

  • GE MultiNet, 4 MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL INSTRUCTION MANUAL 4. 10BASE-F Fiber Optic Port The fiber optic communications port allows for fast and efficient communications with Modbus TCP/IP at 10 Mbps. Fiber optic transmissions provide an ideal solution for areas where RS485 communications or Ethernet via a twisted pair have traditionally caused problems. Fiber is immune to electrical interference and provides complete isolation. Optical fibers may be connected to the MultiNet supporti

  • GE MultiNet, INSTRUCTION MANUAL MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL 5 5. Input Power Terminals The input power terminals are located on the left side of the green terminal block. MultiNet may be connected to either 90 to 265 V AC at 50/60 Hz or 90 to 300 V DC supply power. The terminals are labeled "+" and "–" for DC positive and negative input power and "L" and "N" are for AC line and neutral input power. The GND terminal must be connected to ground to ensure adequate protection against transients. CAUTION Control power supplied t

  • 6 MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL INSTRUCTION MANUAL 6. Mounting MultiNet is DIN rail mountable and ships with two DIN rail clips attached on the rear of the unit. The DIN rail clips can attach the unit onto a standard 35 mm DIN rail. Place the top hooks of the clip against the DIN rail and apply a downward force until an audible click is heard. I

  • GE MultiNet, INSTRUCTION MANUAL MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL 7 7. Getting Started With EnerVista to Setup Multinet The MultiNet setup software is provided to edit settings and configure the unit. The setup software connects to the unit through either the 10BaseT (RJ45*) port or the 10BaseF (fiber) port. NOTE Note * Use a shielded RJ45 cable The following requirements must be met to ensure correct operation of the MultiNet setup software: • Pentium class or higher processor (Pentium II 300 MHz or higher recommended) • Windows 95, 98, 98SE, ME, NT 4.0 (Service Pack 4 or higher), 2000, XP • 64 MB of RAM (256 MB recommended) • 40 MB of available

  • GE MultiNet, 8 MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL INSTRUCTION MANUAL . 2. Setup the MultiNet Software: i On the main enerVista page, select “IED SetUp” from the LaunchPad window. ii Click on the “Install Software” button at the top of the screen. iii Select MultiNet from the product list. Indicate whether you are installing the software from CD or the Web, then click “Check Now”. iv Check off the MultiNet Setup program from the Downloads screen and click “Download Now”. v Once the download is complete, the MutiNet installation file will be shown on screen. Double-click this file to run the installation program. vi Run the installation progr

  • GE MultiNet, 10 MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL INSTRUCTION MANUAL 8. Configuration Before starting, verify that the Ethernet network cable is properly connected to the Ethernet port on MultiNet. To connect MultiNet directly to the Ethernet port of a PC or laptop, use a crossover cable; to connect MultiNet directly to an Ethernet network, use a regular pass-through RJ-45 cable. To setup MultiNet for Ethernet communications use the following procedure: 1. Install and start the latest version of the MultiNet S

  • GE MultiNet, INSTRUCTION MANUAL MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL 11 5. The MAC address is used to identify and configure the unit. Fill in the MAC address field with the address found on the back of MultiNet (for example, 00-20-4A-62-AE-66). FIGURE –4: Device Setup Screen 6. Under network settings, enter the IP address, Subnet and Gateway of the MultiNet network interface. If these values are not known, consult your network administrator. 7. Under port settings, enter the Baud Rate and Parit

  • GE MultiNet, 12 MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL INSTRUCTION MANUAL 8.1 EXAMPLE: Connecting MultiNet to a PQM The following steps detail how to use MultiNet in order to connect a PQM to an Ethernet network. 1. Wire COM1 on the back of the PQM to the RS485 terminals on MultiNet. The wiring is detailed in Figure 2: Typical Configuration. Since for this example short cable runs are used, terminators are not necessary. 2. Check the settings within the PQM, noting the Baud rate, Parity Bit and Slave Address. For the sake of this example the values of 19200, none (or N), and 254 will be used for the

  • GE MultiNet, INSTRUCTION MANUAL MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL 13 FIGURE –5: Device Setup Screen within Viewpoint 8. On the left is the device list showing the “Quick Connect” default site. Click on the plus sign next to the “Quick Connect” site to reveal the “Quick Connect” default device. Selecting this device allows parameters to be entered in the right pane. 9. For this example, we are going to configure the “Quick Connect” device as our PQM. Select Ethernet as the interface and fill in the IP address and slave address of the PQM. 10. Click Read Order Code. Viewpoint will

  • 14 MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL INSTRUCTION MANUAL FIGURE –6: Dialog Box for Creating “plug and play” Screens 12. When finished, the plug and play menu will appear, showing our PQM labeled as Quick Connect. Click the Dashboard button below the PQM icon to view the device information. We have now successfully accessed our PQM through MultiNet. FIGU

  • GE MultiNet, INSTRUCTION MANUAL MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL 15 8.2 EXAMPLE: Configuring a Laptop to Communicate to MultiNet over Crossover Cable. This procedure details how to configure MultiNet for use with a crossover cable. Using a crossover cable allows for a direct local connection to a MultiNet device, bypassing the network. The following procedure is based upon the Windows 2000 operating system; variations of this procedure will work other windows operating systems, as they are all fairly similar. NOTE Note This example uses sample values for IP address, subnet and gateway. Please substitute these values with your own 1. Connect a CAT5 crossover Ethern

  • GE MultiNet, 16 MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL INSTRUCTION MANUAL FIGURE –8: Setting the IP Address on a Laptop. 8. Open the MultiNet setup program and follow the procedure detailed within the CONFIGURATION section. For this example use the IP address of 192.168.1.2, subnet of 255.255.255.0 and a gateway of 192.168.1.1. 9. Once the configuration of the MultiNet device is complete, return the laptop to its previous settings using the recorded values from step 5. If the MultiNet device was configured properly, communications may be tested on the connected network using EnerVista, as shown in the first example.

  • 18 MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL INSTRUCTION MANUAL 10. Order Code Multinet * Modbus RTU to Modbus TCP/IP converter with RS485 communications FE 10BaseT Ethernet Port, and 10BaseF fiber optic port

  • GE MultiNet, INSTRUCTION MANUAL MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL 19 11. Specifications ETHERNET Version 2.0/IEEE 802.3 10BaseT: ....................................................................................................RJ45 connection* 10BaseF: .....................................................................................................820 nm, multi-mode, fiber optic with ST connector Modbus ® TCP/IP NOTE Note * Use a shielded RJ45 cable. RS485 PORT RS485 2-wire, half duplex, isolated Baud Rate: ................................................................................................300 bps to 115.2 Kbps Protocol: ...........

  • GE MultiNet, 20 MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL INSTRUCTION MANUAL APPROVALS ENVIRONMENTAL Ingress Protection IEC60529 IP10 Front , IP40 remaining sides Applicable Council Directive: According to: CE compliance Low voltage directive EN60255-27 EMC Directive EN61000-6-2 EN61000-6-4 UL508 North America cULus e83849 - vol 1 section 10 (AC power only, DC sources pending) C22.2.No 14 ISO Manufactured under a ISO 9001 registered program Ambient temperatures Operating range: -20°C to 70°C Altitude: 2000m (max) Insulation Class: 1 Pollution Degree: II Overvoltage Category: II Ingress protection: IP10 Front IP40 top,b

  • GE MultiNet, INSTRUCTION MANUAL MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL 21 12. Warranty For products shipped as of 1 October 2013, GE warrants most of its GE manufactured products for 10 years. For warranty details including any limitations and disclaimers, see the Terms and Conditions at https://www.gegridsolutions.com/multilin/warranty.htm For products shipped before 1 October 2013, the standard 24-month warranty applies.

More Instructions:

DOWNLOAD

Related Products and Documents (Media Converter):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Carrier ASPAX1CCA015 Installation and owner's manual carrier/aspax1cca015-NE5.pdf 27 Jan 2023 44 6.49 Mb
2 Premier Two-Rock Jet 22 Owner's manual premier/two-rock-jet-22-WC4.pdf 11 Apr 2023 9
3 Clarke Focus Operator's manual clarke/focus-CG7.pdf 22 Mar 2023 68 1.94 Mb
4 Samsung S19C200BR Manual del usuario samsung/s19c200br-9BO.pdf 15 Mar 2024 112
5 Briggs & Stratton 58033139 Operator's manual briggs-stratton/58033139-57E.pdf 03 Aug 2022 48 8.36 Mb
6 Southern Enterprises FA9031A0TX Assembly instructions manual southern-enterprises/fa9031a0tx-962.pdf 30 Oct 2022 11

Similar Resources:

  • HP

    8511A

    (69 pages)
    Errata Title & Document Type: Manual Part Number: Revision Date: HP References in this Manual This manual may contain references to HP or Hewlett-Packard. Please note that Hewlett-Packard's former test and measurement, semiconductor products and chemical analysis businesses are now part of Agilent Technologies. We have made no changes to thi …
  • NDS

    POWERSERVICE PLUS 25

    (48 pages)
    - 1POWERSERVICEUser ManualENGLISHVALID FOR THE FOLLOWING MODELS PLUS 25 PLUS 30 PLUS 40 PLUS 12-24/20 PLUS 24-24/20GOLD 25-M GOLD 30-M GOLD 40-M GOLD 12-24-M GOLD 24-24-M …
  • Jaycar

    AC1617

    (5 pages)
    USER MANUAL Table of Contents 1.0 Introduction……………………………………………….....1 2.0 Features………………………………………………………1 3.0 Specifications…………………………………………..……1 4.0 Package Contents…………………………………………..2 5.0 Panel Descript …
  • Televes

    TOX Series

    (12 pages)
    MUX DVBS2 - QAM/COFDM CI TwinMUX DVBS2 - QAM/COFDM CI TwinMUX DVBS2 - QAM/COFDM CI TwinMUX DVBS2 - QAM/COFDM CI TwinESENDERefs. 564301, 564401U3Q2C-S2-CI, U3Q2QA-S2-CI Guía rápidaQuick guideKurzanleitungКраткое руководствоwww.televes.comPYC …
  • Altera

    Arria 10 Avalon-ST Interface

    (20 pages)
    ©2016 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, HARDCOPY, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as trademarks or service marks are the property of their respective …
  • Mitsubishi Electric

    CMS-MNF

    (2 pages)
    Air Conditioning For Building ApplicationMN Converter CMS-MNFInstallation Manual - AnnexingThis unit can be connected to a modem and operated via a telephone line. The connection method is explained below.Recommended modem: U.S. Robotics 56K FAXMODEMThe basic layout for connecting this unit to a modem is shown in Fig.1 below.* Refer to the operat …

Comments, Questions and Opinions: