  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 62 • Clean the drain water filter basket. Remove residues deposited during various washing cycles. • Remove and clean any deposits and incrustations from the washing chamber drain. • Replace the clean filter on the washing chamber drain. • Put the cover for the drain water filter back in place. Lock it in position with the threaded pin. • Put the drain water filter group back in the wash chamber. CLEANING OF WASHING CHAMBER THERMOSTAT PROBE M2 Worker: Is Frequency of Intervention: 6 months METHOD OF INTERVENTION: cle

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 3 CONTENTS 1. GENERAL RULES ......................................................................................................................................6 1.1 L IMITS OF MANUFACTURER ' S LIABILITY ....................................................................................................................... 6 1.2 M ANUAL VALIDITY , CONTENTS AND CONSERVATION .................................................................................................... 6 1.3 R EGULATIONS ................................

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 69 8. Replace the membrane pipe into dispensing pump, manually operating the rotor. 9. Replace the protective mask of the rotor. ATTENTION: the rotor of dispensing pump turns ONLY clockwise !!! CLEANING OF DISPENSING PUMP FOR CHEMICAL PRODUCTS M6 Worker: Is Frequency of Intervention: from 3 to 6 months METHOD OF INTERVENTION: clean the pump for the dispensing of chemical products as described below: • Remove the closure panel of the machine by removing the screws. • Access the chemical

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 65 18.4 Procedure for special maintenance work All special maintenance work is to be performed only by qualified, skilled personnel. A table is shown below which includes possible special maintenance work that may be required. If your machine should require special maintenance, please contact your retailer/distributor. 18.5 Table of special maintenance tasks See scheduled maintenance form table. CLEANING OF COLD EATER INLET FILTERS M4 Worker: Is Frequency of Intervention: 6 months or when necessary METHOD OF INTERVENTION: clean (or replace) the filter on th

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 64 CLEANING AND CHECKING WASH CHAMBER INSTRUMENTATION Worker: Ac Frequency of Intervention: Once a week or when it is necessary METHOD OF INTERVENTION: Carry out an empty washing cycle with a basket present so as to carry out the disinfection process inside the washing chamber. This will guarantee a complete disinfection of the washing chamber, the basket and the hydraulic circuits. In case it is not possible to carry out an emp

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 30 Initially, while the machine is in the stand-by status, it displays the type of program selected, the temperatures, date and time. By pressing one of the programme switch (P1, P2 or P3), the display shows the program selected at the top and at the bottom in red: "press start" or "door open" or any other warnings. By pressing the switch P+ it is possible to scroll all the programs available. LED The keys of thee glass display are touch-sensitive and backlit. BUZZER The buzzer sounds each time a key is pressed and intermittently

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 51 12.2.2 Check After the calibration it is necessary to control the calibration efficacy by the CHECK procedure. Enter the menu: SETTINGS → → → → FLOWMETERS → → → → Insert 2 nd level password → → → → CHECK Select the chemical flowmeter to check and press START to begin the calibration verification. Once finished the dosing, the level of product in the ml-graduated cylinder should be the same of that one shown in the display. Chemical product Whet

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 23 ATTENTION • Drain must be done following International rules. • The manufacturer cannot be held responsible if an inaccurate use of machine causes pollution. • If the discharge pipe is clogged take great care when processing the water and avoid contact with hands, eyes, etc. In the case of contact rinse the parts concerned with plenty of water. • When the machine is connected to an exhaust ventilation system, the drain pipe should be positioned externally of the buildin

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 2 Manufacturer: STEELCO S.p.A. Via Balegante, 27 31039 Riese Pio X (TV) ITALIA Distributor: EURONDA S.p.A. Via dell'Artigianato 7 Montecchio Precalcino (VI) Italy tel. +39 0445 329811 fax +39 0445 865246 [email protected] www.euronda.com

  • REV.0.02_COD.500201_A4 PAG. 38 MAIN MENU SELECT PROGRAM Show the list of basic cycles that are not changeable, but that can be show or copy BASIC PROGRAMS LIST OF PROGRAM PHASES Allow to copy a single phase SHOW PARAMETERS COPY PHASE COPY SHOW PASSWORD CUSTOMER PROGRAMS PROGRAM

  • REV.0.02_COD.500201_A4 PAG. 72 20. DECOMMISSIONING 20.1 Instructions for disassembly of the machine For demolition and subsequent disposal of your machine, proceed as follows: • Disconnect the machine from the electrical power and water supply, and from the drain. With the machine disconnected, check that t

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 35 8. MACHINE STATUS When there is a voltage drop in the line and the tension is restored, the machine memorises the status that was present at the time of the voltage drop. When the tension is restored the machine normally returns to "wait" mode. 8.1 Wait The machine is ready to start a cycle. The diagnostics are active. If necessary the display indicates that the door is open or gives warning messages: no detergent, no limescale remover, memory full (historic data) or high temperature inside chamber. 8.2 Cycle Cycle mode is entered by pressing the Start key, this comm

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 45 Sw version 7.04 CATEGORY SECTION PARAMETER DESCRIPTION MIN MAX UDM CHAMBER 7 33 Temperature difference respect the set-point ,for de- activating the chamber heating when set-point is over 90°C P7.34 3 NUM CHAMBER 7 34 Temperature difference respect the set-point ,for re- activating the chamber heating when set-point is over 90°C 0,1 P7.33 NUM ÉQUIVALENCE CHEMICALS 8 5 Chemical product for dosing pump 1: i

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 9 2.2 Important warnings and suggestions For proper use of the machine, and in order to safeguard employed staff, carefully comply with the following general and specific standards. THE OPERATOR MUST: • Carefully adhere to the provisions and instructions provided by the employer, managers and supervisors for individual and group safety. • Use safety devices appropriately and with care, as well as group and individual safety gear provided by the employer. • Immediately inform the employer, the manager and the supervisor of deficiencies in the aforementioned

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 28 WARNING • Do never emptying any solid waste into the machine (excrement, toilet paper etc.). This will block the outlet system with pump and destroy the machine. • The treatment cycle has to be activated only if the basket is present into the machine or if it is used a basket equipped with an injection system. • Non observance, even in part, of the rule here indicated, can cause dangerous leakage of water from the door. 5.5 Treatment of turbines and straight and angular hand pieces (opposed-angles) Your

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 15 2.8 Indication of sound level The value shown refers to the measurement obtained on a machine of the same type as that covered herein and measured with an instrument at a height of 1.5 m at a distance of 1 m from the machine. AVERAGE SOUND PRESSURE LEVEL: < 70 dB (A) 2.9 Transport and storage Environment conditions: • Temperature range -5 ... +50 °C; • Relative Humidity range 20…90% without condensation; • Ventilation: Air exchange not required (required only if chemical tanks ar

  • REV.0.02_COD.500201_A4 PAG. 42 Sw version 7.04 CATEGORY SECTION PARAMETER DESCRIPTION MIN MAX UDM CYCLE 1 16 Enable warning for full historical cycle: (0= no warning, 1= warning without cycle start block, 2= warning and block the cycle start). The warning will be reset if the historical cycle will be printe

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 11 2.4.1 Inlet water quality The quality of the water used in all stages of cleaning is important for good results. The water used in each stage must be compatible with: • The material of which the washer disinfector is made. • The chemicals used in the process. • Process requirements for the various stages of the process. The main factors for good inlet water quality in relation to the washing efficacy are: HARDNESS The high hardness of the water generates a detergent inactivation, reducing its efficacy. It also causes limescale deposits in the machine, jeopardizing the cle

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 33 7. WASHING PROGRAMMES The machine has three main washing programs in according to the necessity: RAPID PROGRAMME P1 Suitable for lightly soiled items. STANDARD PROGRAMME P2 Suitable for moderately soiled items. INTENSIVE PROGRAMME P3 Suitable for heavily soiled items. The machine has several washing programmes. To enable programmes, follow the procedure: Enter the menu: Program selection → →→

  • REV.0.02_COD.500201_A4 PAG. 31 PIC. 5 At the end of the cycle, a special window appears as shown in Pic.5. PIC. 6 In case of stop of the cycle, a window appears with a message that warns of the disinfection lack (Pic.6). 6.1.1 Keys BUTTON DESCRIPTION START After having selected the programme to be run pre

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 52 13. CLOCK • The card has a real-time clock. • Time readings are also used when recording historical data. 14. HISTORICAL DATA During the working cycle, the machine memorizes on a card all the working data of the wash cycles that have been performed. • The card is able to record the fields described below for up to a max. of 200 cycles in the permanent memory. The fields given in the example below are recorded for each cycle: DATE START TIME PROGRAMME MAX °C HOLD>85°C FAULTS 12/12/2012 12.00 Short

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 16 3. INSTALLATION (FOR THE INSTALLER ONLY) 3.1 Activity prior to installation PREPARATION OF INSTALLATION SITE: Arrangements for connections to the electrical and plumbing systems must be provided by the client prior to machine installation. Connections must be compliant with current directives in the country of installation and they must comply with the instructions contained in the documentation (provided on request) prior to machine installation. Environment conditio

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 49 Chemical product Calculate the value of calibration as the ratio between the time measured by the stopwatch and the amount of chemical product dosed in the cylinder (Ex. 45 sec / 100 ml = 0.45). Insert the previously calculated value in the relative parameter relative of the doser on the section “EQUIVALENCE”. 12.1.2 Check After the calibration it is necessary to control the calibration efficacy by the check procedure: • Activate manually the dosing device and the stopwatch to start measuring the time. • When the stopwatch reaches the dosing time measured in the

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 43 Sw version 7.04 CATEGORY SECTION PARAMETER DESCRIPTION MIN MAX UDM PT1000 3 33 Drying probe presence 0 1 YES_NO EQUIPMENT 3 35 Enable power reduction 0 1 YES_NO WATER 3 37 Absence of demineralised water (1: load cold water in its place) 0 1 YES_NO CYCLE 3 51 Number of automatic cycle repetition for washing test (0: none) 0 100 NUM PROBE PT 1000 PT1000 4 1 Offset calibration chamber probe1 at a 0�

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 67 CLEANING OF DRYING HEPA FILTER (IF PRESENT) M5 Worker: Is Frequency of Intervention: 300 hours METHOD OF INTERVENTION: clean (or replace) the drying system filter as described below: • Remove the two screws from the drying system filter protective front panel and remove it from the machine. • Extract the pre-filter and than the HEPA filter: replace it with another filter of the same type. • Carefully put the pre-filter back in place. Use the screws to fasten the previously removed protective fr

  • REV.0.02_COD.500201_A4 PAG. 53 15. ALARMS and EVENTS LIST 15.1 Logical description of alarm interventions During machine operation, the operator is aided by ALARMS or WARNING which make use of visual signals on the operator display panel to advise him of possible anomalies in progress and machine alarms which have int

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 27 5.3 Switching on Turn on the machine following the procedure: • Push the ON-OFF button on the control panel of machine. • The control panel starts automatically. • Check that there are no alarm message. In negative case remove it. 5.4 Preparation WARNING: Prior to placing instruments in the washer disinfector, remove materials like composite, cement and amalgam following proper protocol an waste management. • Place the items to be washed inside the machine and position them carefully on the holder and in the

  • Euronda Eurosafe 60, REV.0.02_COD.500201_A4 PAG. 56 17. USB PORT On the control panel board there is an USB port that allows the machine programming and data saving. 17.1.1 Programming It is sufficient to insert the USB key on the port and switch OFF and switch ON the control panel board using the ON/OFF button. The display will ask about the new files installation allowing the selection between APPEND (add only the new parts) and OVERWRITE (dele

Related Products and Documents (Washer):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Panasonic DMC-GF3KPP Service manual panasonic/dmc-gf3kpp-F87.pdf 28 Jun 2023 77
2 Samsung ATIV Smart PC Pro 5 Operation & user’s manual samsung/ativ-smart-pc-pro-5-8WX.pdf 31 Aug 2022 84 16.34 Mb
3 HP Laserjet,Color Laserjet 4550 Quick reference manual hp/laserjet-color-laserjet-4550-9Q4.pdf 11 Mar 2024 16 1.65 Mb
4 Compaq t1000 - Terminal Thin Client PC Network installation manual compaq/t1000-terminal-thin-client-pc-PQ6.pdf 25 Oct 2023 74
5 Kyocera KM-3650W Quick reference kyocera/km-3650w-7B1.pdf 07 Jan 2023 28
6 KitchenAid KRFC300ESS User instructions kitchenaid/krfc300ess-974.pdf 06 Dec 2022 60

Similar Resources:

  • Midea

    MFL80-DU1403B/C14E-EU

    (37 pages)
    Service ManualWashing Machine Model:MFL80-DU1403B/C14E-EU(NE)Note:Before service the unit, please read this manual first.Contact with your service center if meet problem …
  • Indesit

    PWSE 61070 W

    (60 pages)
    1GBEnglish, 1GBWASHING MACHINEContentsInstallation, 2-3Unpacking and levellingConnecting the electricity and water suppliesThe first wash cycleTechnical dataDescription of the washing machine, 4-5Control panelDisplayRunning a wash cycle, 6Wash cycles and options, 7Table of programmes and wash cyclesWash optionsDetergents and laundry, 8Detergent dispenser dra …
  • GE

    MTW200

    (74 pages)
    Washers29-6074 Safety Instructions .... . . . . . . 2, 3Operating InstructionsCare and Cleaning of the Washer .... . . . . ... . . ....... 13Features . . . . ..... ... . ....... . . . . . . 12Loading and Using the Washer . . . . ....... . . .... . . ... 11Operating instructions .... .... .4–10Installation Instructions . 14–18Troubleshooting Tips .... …
  • Miele

    NOVOTRONIC W 1903

    (44 pages)
    Instruction manualfor washing machineW 1903It is essential to read these operating instructions before ]installing or using the machine to avoidthe risk of accident, or damage to the machine. M-Nr. 05 226 190 …
  • Haier

    HBF855TVE

    (18 pages)
    Automatic DrumWashing MachineHBF1055TVE HBF855TVETable of ContentsBefore usingNames of Parts---------------------------------inside front coverMatters Needing Attention-------------------------------------1-3Installation---------------------------------------------------------4-5Control Panel--------------------------------------------------------6Operationa …
  • GE

    WNCD2050

    (16 pages)
    GEAppliancesSafety h_formation ............Operating InstructionsControl Panel .................. 4Control Settings ................ 5I.oading and U singthe Washer .................. 7, 8Washer Features ................ 6Troubleshootil_g Tips ...... 9-12Customer ServiceProduct Registration ..... 2, 13, 14Se,s'ice TelephoneNumbers ........... 2, Back Cov …

Comments, Questions and Opinions: