  • GE Multilin D30 Line Distance Protection System B-55 APPENDIX B B.4 MEMORY MAPPING B B21A ...Repeated for Received Analog 6 B21C ...Repeated for Received Analog 7 B21E ...Repeated for Received Analog 8 B220 ...Repeated for Received Analog 9 B222 ...Repeated for Received Analog 10 B224 ...Repeated for Received Analog 11 B226 ...Repeated for Received Analog 1

  • GE D30 series, 6-24 D30 Line Distance Protection System GE Multilin 6.4 RECORDS 6 ACTUAL VALUES 6 6.4RECORDS 6.4.1 FAULT REPORTS PATH: ACTUAL VALUES  RECORDS  FAULT REPORTS  FAULT REPORT 1(15) The latest 15 fault reports can be stored. The most recent fault location calculation (when applicable) is displayed in this menu, along with the date and time stamp of the event which triggered the calculation. See the SETTINGS  PRODUCT SETUP  FAULT REPORTS menu for assigning the source and trigger for

  • GE D30 series, 2-10 D30 Line Distance Protection System GE Multilin 2.2 ORDER CODES 2 PRODUCT DESCRIPTION 2 The order codes for the reduced size vertical mount units are shown below. Table 2–5: D30 ORDER CODES (REDUCED SIZE VERTICAL UNITS) D30 - * ** - * * * - F ** - H ** - M ** - P/R ** Reduced Size Vertical Mount (see note regarding P/R slot below) BASE UNIT D30 | | | | | | | | | Base Unit CPU T | | | | | | | | RS485 and Three Multi-mode fiber 100Base-FX (SFP with LC) U | | | | | | | | RS485 and Two Multi-mode fiber 100Base-FX (SFP with LC), One 10/100Base-T (SFP with RJ45) V | | | | | | | | RS485 and Three 10/100Base-T (SFP with RJ45) SOFTWARE 00 | | | | | | | No Software

  • GE D30 series, GE Multilin D30 Line Distance Protection System 5-29 5 SETTINGS 5.2 PRODUCT SETUP 5 Multiple LANS, No Redundancy The following topology provides local configuration/monitoring through EnerVista software on LAN1, to which port 1 (P1) is connected, access to the public network on LAN2, to which port 2 (P2) is connected and communications with SCADA on LAN3, to which port 3 (P3) is connected. There is no redundancy. Figure 5–6: MULTIPLE LANS, NO REDUNDANCY d) NETWORK As outlined in the previous section, when using more than one Ethernet port

  • GE D30 series, GE Multilin D30 Line Distance Protection System 5-121 5 SETTINGS 5.5 FLEXLOGIC 5 ELEMENT: Ground time overcurrent GROUND TOC1 PKP GROUND TOC1 OP GROUND TOC1 DPO Ground time overcurrent 1 has picked up Ground time overcurrent 1 has operated Ground time overcurrent 1 has dropped out GROUND TOC2 Same set of operands as shown for GROUND TOC1 ELEMENT Non-volatile latches LATCH 1 ON LATCH 1 OFF Non-volatile latch 1 is ON (Logic = 1) Non-volatile latch 1 is OFF (Logic = 0) LATCH 2 to 16 Same set of operands as shown for LATCH 1 ELEMENT: Line pickup LINE PICKUP OP LINE PICKUP PKP LINE PICKUP DPO LINE PICKUP I<A LINE PICKUP I<B LINE PICKU

  • GE Multilin D30 Line Distance Protection System 4-5 4 HUMAN INTERFACES 4.2 EXTENDED ENERVISTA UR SETUP FEATURES 4 By default, all settings are specified as locked and displayed against a grey background. The icon on the upper right of the settings window also indicates that the EnerVista software is in EDIT mode. The following example shows the phase time overcurrent settings window in edit

  • GE D30 series, C-6 D30 Line Distance Protection System GE Multilin C.3 SERVER FEATURES AND CONFIGURATION APPENDIX C C C.3SERVER FEATURES AND CONFIGURATION C.3.1 BUFFERED/UNBUFFERED REPORTING IEC 61850 buffered and unbuffered reporting is provided in the GGIO1 logical nodes (for binary status values) and MMXU1 to MMXU6 (for analog measured values). Report settings can be configured using the EnerVista UR Setup software, sub- station configurator software, or via an IEC 61850 client. The following items can be configured: • TrgOps: Trigger options. The following

  • GE D30 series, 5-120 D30 Line Distance Protection System GE Multilin 5.5 FLEXLOGIC 5 SETTINGS 5 ELEMENT: Breaker control BREAKER 1 OFF CMD BREAKER 1 ON CMD BREAKER 1 ΦA BAD ST BREAKER 1 ΦA INTERM BREAKER 1 ΦA CLSD BREAKER 1 ΦA OPEN BREAKER 1 ΦB BAD ST BREAKER 1 ΦB INTERM BREAKER 1 ΦB CLSD BREAKER 1 ΦB OPEN BREAKER 1 ΦC BAD ST BREAKER 1 ΦC INTERM BREAKER 1 ΦC CLSD BREAKER 1 ΦC OPEN BREAKER 1 BAD STATUS BREAKER 1 CLOSED BREAKER 1 OPEN BREAKER 1 DISCREP BREAKER 1 TROUBLE BREAKER 1 MNL CLS BREAKER 1 TRIP A BREAKER 1 TRIP B BREAKER 1 TRIP C BREAKER 1 ANY P OPEN BREAKER 1 ONE P OPEN BREAKER 1 OOS Breaker 1 open command initiated B

  • 5-170 D30 Line Distance Protection System GE Multilin 5.6 GROUPED ELEMENTS 5 SETTINGS 5 Figure 5–77: LOAD ENCROACHMENT APPLIED TO DISTANCE ELEMENT • LOAD ENCROACHMENT MIN VOLT: This setting specifies the minimum positive-sequence voltage required for oper- ation of the element. If the voltage is below this threshold a blocking signal will not be asserted by the element. When selecting this set

  • GE D30 series, GE Multilin D30 Line Distance Protection System 4-3 4 HUMAN INTERFACES 4.1 ENERVISTA UR SETUP SOFTWARE INTERFACE 4 Modbus addresses assigned to firmware modules, features, settings, and corresponding data items (that is, default values, minimum/maximum values, data type, and item size) can change slightly from version to version of firm- ware. The addresses are rearranged when new features are added or existing features are enhanced or modified. The EEPROM DATA ERROR message displayed after upgrading/downgrading the firmware is a resettable, self-test message intend

  • GE D30 series, GE Multilin D30 Line Distance Protection System 5-43 5 SETTINGS 5.2 PRODUCT SETUP 5 The fixed GOOSE settings are shown below: PATH: SETTINGS  PRODUCT SETUP  COMMUNICATIONS  IEC 61850 PROTOCOL  GSSE/GOOSE CONFIGURATION  TRANSMISSION  FIXED GOOSE These settings are applicable to fixed (DNA/UserSt) GOOSE only. The GOOSE ID setting represents the IEC 61850 GOOSE application ID (GoID) name string sent as part of each GOOSE message. This string identifies the GOOSE message to the receiving devi

  • GE D30 series, GE Multilin D30 Line Distance Protection System 5-249 5 SETTINGS 5.8 INPUTS AND OUTPUTS 5 b) LOCAL DEVICES: ID OF DEVICE FOR TRANSMITTING GSSE MESSAGES In a D30 relay, the device ID that represents the IEC 61850 GOOSE application ID (GoID) name string sent as part of each GOOSE message is programmed in the SETTINGS  PRODUCT SETUP  COMMUNICATIONS  IEC 61850 PROTOCOL  GSSE/GOOSE CONFIGURATION  TRANSMISSION  FIXED GOOSE  GOOSE ID setting. Likewise, the device ID that represents the IEC 61850 GSSE application ID name string sent as part of each GSSE mes- sage is programmed in the

  • 1-18 D30 Line Distance Protection System GE Multilin 1.5 USING THE RELAY 1 GETTING STARTED 1 1.5.4 RELAY ACTIVATION The relay is in the default “Not Programmed” state when it leaves the factory. When powered up successfully, the Trouble LED is on and the In Service LED off. The relay in the “Not Programmed” state blocks signaling of any output relay. These co

  • GE D30 series, GE Multilin D30 Line Distance Protection System 6-23 6 ACTUAL VALUES 6.3 METERING 6 Loop impedance is defined as Z##=|Z##| Angle=R##+jX##, in secondary ohms and ## is the loop indication (AB, BC, CA, AG, BG, and CG respectively). They are calculated as per the following equations. Where VA, VB, VC are phase voltage phasors in secondary volts; IA, IB, IC are current phasors in secondary amps, I0 is the zero sequence current phasors in secondary amps; and IG is the ground current from the parallel line scaled to the source phase CT in secondary amps. Z0/Z1 is the zero sequence impedance to positive sequence impedance ratio, and Z0M/Z1 is mutual zero sequence imped- ance

  • GE D30 series, 10-4 D30 Line Distance Protection System GE Multilin 10.2 BATTERIES 10 MAINTENANCE 10 b) REPLACE BATTERY FOR SH/SL POWER SUPPLY The power supply module contains the battery. To avoid injury, ensure that the unit has been powered off for a minimum of three minutes before replacing the battery. Risk of fire if battery is replaced with incorrect type or polarity. To replace the battery: 13. Turn off the power to the unit. 14. Wait a minimum of three minutes to ensure that there is no power to the battery. 15. As outlined in the previous section, open the unit by sliding up the plastic latch on the right side of the front panel (stan- dard front panel) or unscrewing the panel (enhanced

  • GE D30 series, GE Multilin D30 Line Distance Protection System 6-7 6 ACTUAL VALUES 6.2 STATUS 6 6.2.12 FLEX STATES PATH: ACTUAL VALUES  STATUS  FLEX STATES There are 256 FlexState TM bits available. The second line value indicates the state of the given FlexState bit. 6.2.13 ETHERNET PATH: ACTUAL VALUES  STATUS  ETHERNET These values indicate the status of the first, second, and third Ethernet links. 6.2.14 REAL TIME CLOCK SYNCHRONIZING PATH: ACTUAL VALUES  STATUS  REAL TIME CLOCK SYNCHRONIZING The RTC Sync Source actual value is the time synchronizing source the relay is using at present. Possible sources are: Port 1 PTP Clock, Port 2 PTP Clock, Port 3 PTP Cl

  • GE D30 series, GE Multilin D30 Line Distance Protection System 5-173 5 SETTINGS 5.6 GROUPED ELEMENTS 5 IEC CURVES For European applications, the relay offers three standard curves defined in IEC 255-4 and British standard BS142. These are defined as IEC Curve A, IEC Curve B, and IEC Curve C. The formulae for these curves are: , (EQ 5.8) where: T = operate time (in seconds), TDM = Multiplier setting, I = input current, I pickup = Pickup Current setting, K, E = constants, t r = characteristic constant, and T RESET = reset time in seconds (assuming energy capacity is 100% and RESET is “Timed”) Table 5–21: IEC (BS) INVERSE TIME CURVE CONSTANTS IEC (B

  • GE D30 series, C-30 D30 Line Distance Protection System GE Multilin C.7 LOGICAL NODES APPENDIX C C TPOS: Position indicator --- TPRS: Pressure sensor --- TRTN: Rotation transmitter --- TSND: Sound pressure sensor --- TTMP: Temperature sensor --- TTNS: Mechanical tension --- TVBR: Vibration sensor --- TVTR: Voltage transformer --- TWPH: Water acidity --- X: LOGICAL NODES FOR SWITCHGEAR XCBR: Circuit breaker Yes XSWI: Circuit switch Yes Y: LOGICAL NODES FOR POWER TRANSFORMERS YEFN: Earth fault neutralizer (Petersen coil) --- YLTC: Tap changer --- YPSH: Power sh

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Lenovo 3000 N100 0689 Hardware maintenance manual lenovo/3000-n100-0689-Q24.pdf 19 Aug 2022 120
2 Hunter 33116 Manual del propietario hunter/33116-X2N.pdf 31 Aug 2023 10
3 Insignia NS-42E859A11 Specifications insignia/ns-42e859a11-762.pdf 10 Feb 2024 2
4 Morphy Richards ECO PRIUS Instruction manual morphy-richards/eco-prius-K47.pdf 09 Sep 2023 6
5 PowerFlex POWER VENTED GAS Models Installation and operating manual powerflex/power-vented-gas-models-CJU.pdf 19 Apr 2023 60
6 Pro-Ject Audio Systems Pro-Ject 6 PerspeX User manual manual pro-ject-audio-systems/pro-ject-6-perspex-L6E.pdf 31 Jul 2023 8

Similar Resources:

  • Eaton

    Crouse-hinds series

    (20 pages)
    Explosionsgeschützte Steckvorrichtungen, 16A 7-polig, GHG 511 .7.. / GHG 592, 10A 21-polig, GHG 511 .9../ GHG 591Explosion-protected plugs and sockets, 16A 7-pole, GHG 511 .7.. / GHG 592, 10A 21-pole, GHG 511 .9../ GHG 591Fiches et prises à 16A 7 pôles, GHG 511 .7../ GHG 592, à 10A 21 pôles, GHG 511 .9.. / GHG 591, pour atmosphères …
  • Eaton

    Bussmann Series

    (12 pages)
    Installation manual 3A3718 Rev EEffective February 2019Supersedes January 2019CCP2-H4X-_ pistol handles for use with 12 mm shaftsThese instructions cover the installation procedures specific to the catalog numbers shown above. Please review the switch and switch handle applications table on page 2 to ensure the handle in this kit can be installed on your sp …
  • StarTech.com

    RKPW081915

    (2 pages)
    Instruction ManualDE: Bedienungsanleitung - de.startech.comFR: Guide de l'utilisateur - fr.startech.comES: Guía del usuario - es.startech.comIT: Guida per l'uso - it.startech.comNL: Gebruiksaanwijzing - nl.startech.comPT: Guia do usuário - pt.startech.comManual Revision: 11/09/2011For the most up-to-date information, please visit: www.startech.co …
  • H+H

    SE Series

    (33 pages)
    Höcherl & Hackl GmbH  +49 (0) 9963 94301 0 Bedienungsanleitung / User Manual Industriestr. 13  +49 (0) 9963 94301 84 Dokument / Document: SE 11 19 - 09A 94357 Konzell [email protected] Ausgabedatum / Date of Issue: 20.11.2019 GERMANY www.hoecherl-hackl.com Bedienungsanleitung 19“ Stromverteilung Serie SE User Manual 19 …
  • Eaton

    Crouse-hinds series

    (36 pages)
    Explosionsgeschützte Notleuchten Serie: eLLK(M)(S)92 LED 400(800) NEExplosion protected emergency light fittings Series: eLLK(M)(S)92 LED 400(800) NELuminaires de sécurité pour atmosphères explosives Série: eLLK(M)(S)92 LED 400(800) NEBetriebsanleitungOperating instructionsMode d’emploiCROUSE-HINDSSERIES300 8000 1462 D/GB/F (-) …
  • Sonnen

    sonnenProtect 2500

    (28 pages)
    Installation instructions | for electricianssonnenProtect 2500for sonnenBatterie hybrid 9.53KD-535 • Part no. 1000050 • Version 02 [email protected] • sonnen.de …

Comments, Questions and Opinions: