Manualios.com

GE PACSystems* RX3i Operation & User’s Manual

  • PACSystems* RX3i Controller
  • ma3f6y4E2zLeA
  • Operation & User’s Manual
  • PDF / Adobe Acrobat Reader
  • 95

GE PACSystems* RX3i Manual Online:

3.95, 1585 votes
GE PACSystems* RX3i User Manual
GE PACSystems* RX3i User Guide
GE PACSystems* RX3i Online Manual

Text of GE PACSystems* RX3i User Guide:

  • GE PACSystems* RX3i, Contact Information If you purchased this product through an Authorized Channel Partner, please contact the seller directly. General Contact Information Online technical support and GlobalCare http://support.ge-ip.com Additional information http://www.ge-ip.com/ Solution Provider [email protected] Technical Support If you have technical problems that cannot be resolved with the information in this manual, please contact us by telephone or email, or on the web at http://support.ge-ip.com Americas Online Technical Support http://support.ge-ip.com Phone 1-800-433-2682

  • GE PACSystems* RX3i, Chapter 6. Configuration of IEC 104 Server Parameters Using COMMREQ GFK-2949C July 2017 39 6.3.3 Configuration Examples for Address Translation Case 1: Configuring Translation Memory Tables with two Different Offset Values and CPO with a Non-Zero Value Figure 15: COMMREQ Parameters & Corresponding Read/Write Permissives (Case 1) • Points > = CPO are configured for Read / Write operations. • Points < CPO are Configured for Read only. Figure 16: Red/Write Interact

  • GE PACSystems* RX3i, GE Intelligent Platforms Programmable Control Products PACSystems* RX3i IEC 104 Server Module IC695EIS001 User Manual GFK-2949C July 2017 g

  • GE PACSystems* RX3i, Chapter 6. Configuration of IEC 104 Server Parameters Using COMMREQ GFK-2949C July 2017 55 6.5 Point Push Interface Definition Point Push is an IEC 104 Server feature used to manually enter IEC 104 point data, date and time, and/or flags information into the internal database of the EIS001 module. This feature is available in either SOE mode, or NON-SOE Mode. It can be used to interface a Controller to an SOE or record- based system (local or remote) so that records containing information from the source can be transferred to the EIS001. Point Push works by specifying a CPU memory interface region for the EIS00

  • GE PACSystems* RX3i, Chapter 2. Installation GFK-2949C July 2017 17 2.4 Module Installation 2.4.1 Mounting the EIS001 The EIS001 mounts in any suitable main rack I/O slot of the RX3i backplane. Refer to PACSystems RX3i System Manual, GFK-2314 Chapters 2 and 3 for details on how to mount/dismount RX3i modules and slot choices available. The EIS001 may be installed while the rack is under power. Refer to PACSystems RX3i System Manual, GFK-2314 Chapter 2 for hot-swap details. At least 75 mm (3”) must remain clear above and below the module to allow for convection cooling. Power Connection Once the module has been mounted in the

  • Chapter 6. Configuration of IEC 104 Server Parameters Using COMMREQ 40 PACSystems RX3i Ethernet 104 Server Module User Manual GFK-2949C Case 2: Configuring Translation Memory Offset with Zero and CPO with Non-Zero Value Figure 17: COMMREQ Parameters & Corresponding Read/Write Permissives (Case 2) • Translation memory offsets are disabled when both the Read and Command offset values

  • GE PACSystems* RX3i, Appendix D. Device Profile 76 PACSystems RX3i Ethernet 104 Server Module User Manual GFK-2949C Type identifier and cause of transmission assignments (station-specific parameters) Shaded boxes are not required. Black boxes are not permitted in this companion standard Blank: functions or ASDU not used. Mark Type Identification/Cause of transmission combinations: ‘X’ if only used in the standard direction ‘R’ if only used in the reverse direction ‘B’ if used in both directions T

  • GE PACSystems* RX3i, Chapter 3. Configuration 22 PACSystems RX3i Ethernet 104 Server Module User Manual GFK-2949C 3.4 LAN Interface Status Bits There are 80 LAN Status bits; the EIS001 module will typically use two of the LSI bits to control parameterization, as follows: i. The EIS001 will signal that it is ready to accept parameterization by asserting Bit 11. and ii. The CPU should typically not communicate with the EIS001 until such time as Bit 13 has been asserted. Note: Should there be a failure of the EIS001 during parameterization, these bits may remain in a 1 or 0 state. Figure 8: EIS001 LAN Status Bits (Bits 11 & 13)

  • GE PACSystems* RX3i, Chapter 6. Configuration of IEC 104 Server Parameters Using COMMREQ GFK-2949C July 2017 57 6.5.3 Interface Collection Mechanism Based on the Record Format in section 6.5.2, the following is the process for pushing points into the EIS001: • IF words [000] and [002] are non-zero, a point push is in operation is processing, or has ended in an error. • IF words [000] and [002] are both 0 a point push can start. 1. Fill the IEC 104 records into the table 2. In word [002] place the number of records to be

  • GE PACSystems* RX3i, Chapter 1. Introduction 2 PACSystems RX3i Ethernet 104 Server Module User Manual GFK-2949C 1.2 IEC 104 Overview IEC 104 is a client/server communications protocol originally developed for use in the electric utility sector for power transmission and distribution systems. It has migrated to other vertical markets, and is now a general market protocol based on a 3-layer protocol scheme. IEC 104 is a generational protocol coming from a foundation of the IEC 60870-5-101 protocol. Figure 1: IEC 104 Basic System Architecture Fig

  • Appendix D. Device Profile GFK-2949C July 2017 77 Type identification Cause of transmission periodic, cyclic background scan spontaneous initialized request or requested activation activation confirmation deactivation deactivation confirmation activation termination return info caused by a remote cmd return info caused by a local cmd file trans

  • GE PACSystems* RX3i, Chapter 1. Introduction 8 PACSystems RX3i Ethernet 104 Server Module User Manual GFK-2949C M_ME_TE_1 35 Measured value, scaled value with time tag CP56Time2a M_ME_TF_1 36 Measured value, scaled value with time tag CP56Time2a M_EP_TE_1 39 Packed start events of protection equipment with time tag CP56Time2a M_EP_TF_1 40 Packed output circuit information of protection equipment with time tag CP56Time2a 1.7.4 ADSU Supported Commands ADS

  • GE PACSystems* RX3i, Appendix D. Device Profile 84 PACSystems RX3i Ethernet 104 Server Module User Manual GFK-2949C Definition of time outs Parameter Default value Remarks Selected value t 0 30s Time-out of connection establishment Fixed t 1 15s Time-out of send or test APDUs Fixed t 2 10s Time-out for acknowledges in case of no data messages t 2 < t 1 Fixed t 3 20s Time-out for sending test frames in case of a long idle state Fixed Maximum range of values for all time outs: 1 to 255 s, accuracy 1 s Maximum number of outstanding I format APDUs k and latest acknowledge APDUs (w) Parameter Default valu

  • GE PACSystems* RX3i, Chapter 6. Configuration of IEC 104 Server Parameters Using COMMREQ GFK-2949C July 2017 59 6.8 IEC 104 Communications Start-up The EIS001 module will power up and signal the user program through LIS bit 11 that it is ready to receive the configuration parameters as defined in the ST block. LIS bit 11 and LIS bit 13 (LAN OK) are used together in the user program to execute the one-shot signal to configure the module with its parameters. LAN Interface Status (LIS) bits 10, 11, and 12 are reserved

  • GE PACSystems* RX3i, Appendix D. Device Profile 80 PACSystems RX3i Ethernet 104 Server Module User Manual GFK-2949C D-3.6 Basic Application Functions Station initialization (station-specific parameter, mark ‘X’ if function is used) Cyclic data transmission (station-specific parameter, mark ‘X’ if function is only used in the standard direction, ‘R’ if only used in the reverse direction, and ‘B’ if used in both directions) Read procedure (station-specific parameter, mark ‘X’ if function is only used in the standard direction, ‘R’ if only used in t

  • Contents GFK-2949C July 2017 iii APPENDIX D DEVICE PROFILE ............................................................................................................................ 66 D-1 REVISION HISTORY .............................................................................................................................................................. 67 D-2 INTRO

  • Chapter 6. Configuration of IEC 104 Server Parameters Using COMMREQ GFK-2949C July 2017 45 6.4.3 Parameters for Server Status Space The Server Status Space is a 100-word data table that contains the current operational status of the Client station-Server connection. Set appropriate values for the constituent parameters as required by the application. The Controller

  • GE PACSystems* RX3i, Chapter 1. Introduction 4 PACSystems RX3i Ethernet 104 Server Module User Manual GFK-2949C 1.4 Product Overview The PACSystems RX3i Ethernet IEC 60870-5-104 Server Module, catalog number IC695EIS001 implements the IEC communications protocol. It permits a PACSystems RX3i controller to be connected to an Ethernet network using a standard TCP/IP connection scheme, allowing an IEC 104 Client to poll data from the Server, as well generate unsolicited communications from the Server back to the Client. Two auto-sensing 10BaseT/100BaseTX RJ-45 shielded twisted-pair Ethernet ports permit direct connecti

  • GE PACSystems* RX3i, GFK-2949C July 2017 1 Chapter 1 Introduction This manual describes the RX3i IEC 60870-5-104 Option Parameters Ethernet Server Module, IC695EIS001 (or EIS001 for short). By installing this module in the backplane of an RX3i controller, the controller may be set up as an IEC 104 Server on an IEC 104 Network. This permits RX3i data to be exchanged with the IEC 104 Clients on that network. Introductory material may be found in this chapter. Chapter 2 provides installation and set-up information. Chapter 3 provides configuration instructio

  • GE PACSystems* RX3i, GE Intelligent Platforms Information Centers Headquarters: 1-800-433-2682 or 1-434-978-5100 Global regional phone numbers are available on our web site www.ge-ip.com ©2014-2017 General Electric Company. All Rights Reserved * Indicates a trademark of General Electric Company and/or its subsidiaries. All other trademarks are the property of their respective owners. Additional Resources For more information, please visit the GE Intelligent Platforms web site: www.geautomation.com GFK-2949C g

  • GE PACSystems* RX3i, Chapter 6. Configuration of IEC 104 Server Parameters Using COMMREQ GFK-2949C July 2017 47 MSP Configuration M_SP ADSU COMMREQ Configuration Parameter Value Description mComreq_Setup[18] m-type value Memory Type for SP Objects Value: 70-%I, 72-%Q, 76-%M, 74-%T, 68-%G, 0-unused mComreq_Setup[19] address value Memory Address for ADSU object Value: 1 to maximum (based on memory type) mComreq_Setup[20] Length Number of ADSU Objects mComreq_Setup[21] CPO Refer to Control Point Offset Configuration discussion in Section 6.4.4. MDP Configuration M_DP ADSU COMMREQ Configuration Parameter Value Description mComreq_Setup[22] m-type value

Related Products and Documents (Controller):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 RuggedCom RuggedMC RMC40 Installation manual ruggedcom/ruggedmc-rmc40-I84.pdf 19 Oct 2022 16 0.38 Mb
2 pro.point 8344558 Operation & user’s manual pro-point/8344558-51M.pdf 22 Aug 2022 32
3 Enviro 1200-V Insert Owner's manual enviro/1200-v-insert-835.pdf 02 Jul 2023 32 3.31 Mb
4 Samsung LN-R238W Owner's instructions manual samsung/ln-r238w-9GA.pdf 23 Nov 2023 88 11.7 Mb
5 Alcatel 2000 User instructions alcatel/2000-6BI.pdf 14 Apr 2024 3
6 Fisher-Price Kid Tough Video Camera Operation & user’s manual fisher-price/kid-tough-video-camera-G64.pdf 16 Aug 2022 24 0.98 Mb

Similar Resources:

  • National Instruments

    SMD-7610

    (30 pages)
    USER MANUALNI SMD-7610This manual describes the NI SMD-7610 stepper motor drive. It describes electrical and mechanical characteristics of the device, as well as I/O functionality.ContentsSafety Information.................................................................................................................... 2Block Diagram....................... …
  • Estun

    E21

    (38 pages)
    Page 1 of 38 E21 Press Brake Numerical Control Device Installation Manual V1.01 ESTUN AUTOMATION CO.,LTD Address :No.155 Jiangjun Road, Jiangning Development Zone Nanjing P.R.C 211106 Postal code:211106 TEL:025-52785569 FAX:025-52785966 WEB:www.estun.com E-mail:[email protected]
  • PS Automation

    PSL201

    (12 pages)
    Version 2018/06/27 Art.No.: 8034359 © 2017 PS Automation GmbH D Kurz-Betriebsanleitung PSL GB Short Operating Instructions PSL E Manual de operación resumido PSL …
  • JORDAN CONTROLS

    SM-1715

    (24 pages)
    1Instruction ManualSM-1700 Series Rotary ActuatorTable of ContentsGeneral Information .............................................. 2-3Introduction ....................................................... 2Cautions ............................................................. 2Receiving/Inspection .......................................... 2Storage ......... …
  • Collcomm

    NCS-C150

    (12 pages)
    NCS-C150 INSTRUCTION MANUAL Rev A Collcomm Inc. d.b.a. NCS Shipping Address 2310 Pendley Road Cumming, Georgia 30041 Mailing Address 1595 Peachtree Parkway Suite 204-123 Cumming, Georgia 30041 Toll Free Tel. & Fax : 888- 883-5788 Email : [email protected] Web Site: www.ncsradio.com collcomm inc …
  • Prolon

    NC2000

    (15 pages)
    HARDWARE GUIDENetwork Controller - NC2000Specifications and Operational GuideREV. 6.1.6PL-HRDW-NC2000-C/F-ENwww.proloncontrols.com | [email protected] 510, rue Charles, Suite 100, Mirabel, QC, J7J 1X9 …

Comments, Questions and Opinions: